What was found
REPEAT WINDOW 2R HEAT FAULTS, MANEUVER WIRING AT S761 & S1028 ENSURE VOLTAGE READING DOES NOT FLUCT AND GND REMAINS STEADY. IF 115VAC NOT AT "B" CHK S1028 & S761 FOR OPEN. IF GND NOT AVAIL AT "A" SUSPECT R7338 DEFECTIVE. IF PWR & GND OK OPEN CB C69, DISC WIRING AT "A&B" ON WDO & CHK RESISTANCE OF WDO 2R PER FIM 30-40 FAULT TREE BOX 5. IF NO FAULT FOUND. REPLACE S761 & S1028. SEE HIST FOR PREV ACTIONS. COMPLETED ALL CHECKS AND MEASURMENTS ALL OK, REPLACED S761 AND S1028 OF WINDOW 2R.