Boeing 747-428F
Service difficulty reports · 284
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747428F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747428F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA1B66670Floor Panel · damagedHOLE IN FLOOR, STA 460. REPAIRED IAW 53-00-50.SDR IPXA11B65474Battery Pack · inoperativeFLIGHT DECK EMERGENCY FWD CEILING LIGHTS DID NOT ILLUMINATE DURING TEST. REPLACED FWD EMERGENCY LIGHT BATTERY PACK IAW 33-51-04-2-1. OPS CHECKS GOOD.SDR IPXA11B65168Floorboard · damagedFLOORBOARD DAMAGED STA 1930. REPAIRED IAW SRM 53-00-50.SDR IPXA1B64821Battery Pack · failedAFT 2EA EMERGENCY LIGHTS DO NOT ILLUMINATE DURING TEST. R & R AFT BATTERY PACK IAW AMM 33-51-04-11. OPS NORMAL.SDR IPXA1B64730Floor Panel · damagedFLOOR PANEL DAMAGED, POS 8L. FABRICATED NEW FLOOR PANEL IAW EO B747-5320-41448-A.SDR IPXA11B64477Intercostal · crackedMAIN CARGO DECK AT POS 'N 5L BELOW CREW STAIRS HAS CRACKED INTERCOSTAL UPPER CHORD. REMOVED INTERCOSTAL UPPER CHORD IAW SRM 51-40-02. THIS ITEM IS CLASSIFIED AS A MAJOR REPAIR AND TRANSFERRED TO NRC 337603. REPLACED UPPER CHORD.SDR IPXA0B63616Handle · inoperativeOVERHEAD HATCH WILL NOT OPEN IN THE UNLOCK POSITION. ADJUSTED OVERHEAD LATCH HANDLE OPS CHK GOOD. REF AMM 52-21-01-4.SDR IPXA10B62722Wedge · delaminatedINSPECTION TYPE:C RH WING INBD FORE FLAP T/E WEDGE UPPER SURFACE DELAMINATION. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07 PAR 5A(1) FIG 5, REV 57.SDR IPXA10B62679Fairing · delaminatedINSPECTION TYPE:C, RT WING INBD MID FLAP L/E FAIRING DELAMINATION. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07 PAR 5A(1) FIG 5 REV 57.SDR IPXA10B63040Skin · damagedINSPECTION TYPE:C, EO B747-2320-37798-A FUSELAGE AT BS 2120-2140 & STR 1L-1R PERFORMED SKIN REPAIR AFTER ELT DOUBLER WAS REMOVED FROM ACFT. FUSELAGE AT BETWEEN BS 2120 TO BS 2140 AND STR 1L-1R AREA DOUBLER INSTALLED IAW EO B747-5330-39508-C (REF DWG DG215-220SDR IPXA10B62800Fairing · dentedINSPECTION TYPE:C, LT WING - NR 6 VC FLAP BULLNOSE FAIRING DENTED 4" X 6" AT MID SECTION. LT WING NR 6 VC FLAP BULLNOSE FAIRING BTN ILES1060 & ILES1082.5 AREA SKIN REPAIRED IAW HX RS R57-44-36823 & EO B747-5750-39749. THIS REPAIR IS CLASSIFIED AS MAJOR REPAIRSDR IPXA10B62723Wedge · damagedINSPECTION TYPE:C, RT WING INBD AFT FLAP T/E WEDGE LWR SURFACE HOLED. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5A(1), FIG 5, REV 57.SDR IPXA10B62670Wedge · misrepairedINSPECTION TYPE:C, LT WING INBD AFT FLAP T/E WEDGE LWR SURFACE EXISTING REPAIR (REDO) NON-STANDARD REPAIR. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5C, FIG 2, REV 57.SDR IPXA10B62658Fairing · misrepairedINSPECTION TYPE:C, RT WING OTBD FORE FLAP L/E FAIRING EXISTING REPAIR (REDO) NON STANDARD REPAIR. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07 PAR. 5A(1) FIG 5, REV 57.SDR IPXA10B62657Wedge · misrepairedINSPECTION TYPE:C, RT WING OTBD FORE FLAP T/E WEDGE LWR SURFACE EXISTING REPAIR (REDO) NON STANDARD REPAIR. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR. 5C FIG 2, REV 57.SDR IPXA10B62652Wedge · misrepairedINSPECTION TYPE:C, RT WING OTBD FORE FLAP T/E WEDGE LWR SURFACE EXISTING REPAIR (REDO) NON-STANDARD REPAIR. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM51-70-07 PAR 5A(1) FIG 5, REV 57.SDR IPXA10B62543Wedge · delaminatedINSPECTION TYPE:C, LT WING INBD FORE FLAP T/E WEDGE LWR SURFACE DELAMINATION. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07 PAR 5A(1), FIG 5, REV. 57.SDR IPXA10B62553Fairing · delaminatedINSPECTION TYPE:C, LT WING OTBD FORE FLAP L/E FAIRING DELAMINATION. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07 PAR 5A(1), FIG 5, REV 57.SDR IPXA10B62720Fairing · delaminatedINSPECTION TYPE:C, RT WING INBD MID FLAP L/E FAIRING DELAMINATION. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5A(1), FIG 5, REV 57.SDR IPXA10B62626Fairing · crackedINSPECTION TYPE:C, RT WING OTBD MID FLAP L/E FAIRING CRACKED. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5G, FIG 9, REV 57.SDR IPXA10B62831Skin · unknownINSPECTION TYPE:C, SURVEY SEQ NR 580-F1-10 FUSELAGE BETWEEN BS 737 TO 756 & S33-38R EXISTED REPAIR TO BE REMOVED & ACCOMPLISHED THE NEW REPAIR. SKIN REPAIR IAW SRM 53-00-01, REPAIR 16, DETAIL II, REV 57. FINAL CUTOUT IS 16.25"X2.875" AT OVERLAPPING & 27.25"X1SDR IPXA10B62799Skin · misrepairedINSPECTION TYPE:C, SURVEY SEQUENCE NR 580-F1-07 FUSELAGE AT BETWEEN BS 532 TO 560 AND S36-39R EXISTING REPAIR DOES NOT CORRELATE TO A SRM. SURVEY SEQ 580-F1-07 FX AT BTN BS 532-560 & S36-39R EXISTING REPAIR R&I IAW HX RS R53-00-36811 REV A & EO B747-5330-3976SDR IPXA10B63027Skin · misrepairedINSPECTION TYPE:C, SURVEY SEQ NR580-F1-11, FUSELAGE SKIN AT BETWEEN BS1697 TO BS 1723 AND STR 44R-47R EXISTING REPAIR DOES NOT CORRELATE TO EFN 58020071001. SKIN REPAIRED IAW RS R53-00-36836 & EO B747-5330-4005-A. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR. SDR IPXA10B63007Skin · misrepairedINSPECTION TYPE:C, SURVEY SEQUENCE NO 580-F1-15 FUSELAGE AT BETWEEN BS2650 TO BS2661 & STR 11R - 13R AREA EXISTING REPAIR DOES NOT CORRELATE TO SRM. SURVEY SEQ 580-F1-15 FUSELAGE AT BETWEEN BS2650-BS2661 & STR 11R-13R AREA SKIN REPAIRED IAW HXRS R53-81-36813 SDR IPXA10B62920Panel · misinstalledINSPECTION TYPE:C, RT OF VERT STAB FIN STA 245 TO STA 220 2FT AFT FROM FIN L/E 2 ROWS OF REPAIRED BLIND RIVETS WAS FOUND. RT VERT STAB FIN STA 220-245 2FT AFT FROM FIN L/E 2 ROWS OF REPAIRED BLIND RIVETS REPLACED WITH RIVET (BACR15FP6E3R) IAW HXRS R55-00-3681SDR IPXA10B62919Panel · misinstalledINSPECTION TYPE:C, LT OF VERT STAB FIN STA 169 TO STA 195 2 ROWS OF REPAIRED BLIND RIVETS. LT VERT STAB FIN STA 169-195 2 ROWS OF REPAIRED BLIND RIVETS REPLACED WITH RIVET (BACR15FP6E3R) IAW HX RS R55-00-36819, REV A & EO B747-5530-39812-A, TOTAL 125EA REPLACSDR IPXA10B62733Panel · misrepairedINSPECTION TYPE:C, RT WING OTBD FORE FLAP LOWER SURFACE OTBD AREA EXISTING REPAIR (REDO) NON STANDARD REPAIR. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R REPAIR 4, FIG 202, SHEET 2, REV 57.SDR IPXA10B62678Panel · misrepairedINSPECTION TYPE:C, RT WING OTBD FORE FLAP LOWER SURFACE MID AREA EXISTING REPAIR NON STANDARD REPAIR. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 202, SHEET 2, REV 57.SDR IPXA10B62668Panel · misrepairedINSPECTION TYPE:C, RT WING OTBD FORE FLAP UPPER PANEL EXISTING REPAIR NON STANDARD REPAIR. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 202, SHEET 2, REV 57.SDR IPXA10B62667Panel · misrepairedINSPECTION TYPE:C, RT WING OTBD FORE FLAP UPPER SURFACE EXISTING REPAIR (REDO) NON-STANDARD REPAIR. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 202, REV 57.SDR IPXA10B62607Fairing · delaminatedINSPECTION TYPE:C, LT WING OTBD FORE FLAP L/E FAIRING FOUND DELAMINATION. FIBERGLASS PREPREG LAY UP REPAIR IAW SRM 51-70-07 PAR 5A(1) FIG 5, REV 57.SDR IPXA10B62605Wedge · delaminatedINSPECTION TYPE:C, LT WING INBD FORE FLAP T/E WEDGE LWR SURFACE FOUND DELAMINATION. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07 PAR 5A(1) FIG 5, REV 57.SDR IPXA10B62732Panel · crackedINSPECTION TYPE:C, LT WING LG INBD STRUT DOOR LOWER FAIRING FWD CUTUT PANEL FOUND CRACKED. LT WING LANDING GEAR W/W FWD CUTOUT FAIRING PNL SKIN REPAIRED IAW HX RS NR R-53-27-36808, REV A & EO B747-5320-39567-A. THIS REPAIR IS CLASSIFIED AS MINOR REPAIR. 3" SKSDR IPXA10B62625Fairing · delaminatedINSPECTION TYPE:C, RT WING OTBD MID FLAP L/E FAIRING PUNCTURE. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07 PAR 5C, FIG 2, REV 57.
Back to Boeing 747-428F