Boeing 747-451
Service difficulty reports · 2,469
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA12000466315Light · inoperativeDURING INSPECTION FOUND FLOOR PROXIMITY EMERGENCY LIGHTS IN FRONT OF LAVATORY 4R INOPERATIVE. MAINTENANCE RECONNECTED LIGHTS AND OPS CHECKED OK PER AMM 33-51.SDR DALA12000456315Light · inoperativeDURING INSPECTION FOUND FOUR FLOOR PROXIMITY EMERGENCY LIGHTS INOPERATIVE AROUND DOOR 3R FLIGHT ATTENDANT SEAT. MAINTENANCE REPLACED LIGHT ASSEMBLY PER AMM 33-5. OPS CHECKED OK.SDR DALA12000426305Frame · crackedDURING INSPECTION, FOUND CABIN UPPER LOBE TENSION TIES AREA BS 1160 STINGER-9L FRAME WEB AT STRINGER CUTOUT CRACKED. MAINTENANCE REMOVED AND REPLACED CRACKED FRAME WEB WITH NEW WEB AS PER SRM 53-40-07 REPAIR 3 FIG 201 AND 51-40-02.SDR DALA12000416305Stringer · crackedDURING INSPECTION FOUND CRACK AT FUSELAGE STRINGER S-10L AT BS 460. MAINTENANCE REPAIRED STRINGER CRACK PER CARD NO: 5314-01048-02G FOR WORK DETAIL.SDR DALA12000406305Angle · crackedDURING INSPECTION FOUND CRACK ON ANGLE AT RIGHT BS 800 FRAME AT STRINGER 17. MAINTANENCE REPAIR CARRIED OUT AS PER PRI ER/A503096-14AD.SDR DALA12000396305Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON LAVATORY FLOOR SUPPORT AT BS 1655 AND LBL 117. MAINTENANCE REMOVED AND REPLACED DAMAGED FLOOR SUPPORT AS PER SRM 51-40-02.SDR DALA12000566305Frame · crackedDURING INSPECTION FOUND CABIN UPPER LOBE TENSION TIES AREA BS 1140 STRINGER-10L. FOUND FRAME WEB AT STRINGER CUTOUT CRACKED. MAINTENANCE REPAIR CARRIED OUT AS PER SRM 53-40-07 REPAIR 2 FIG 20.SDR DALA12000536305Frame · crackedDURING INSPECTION FOUND CRACK AT LEFT SIDE TENSION TIE AT BS 1180 ON TOP FASTENER ROW, 5TH FASTENER HOLE FROM OUTBOARD LOOKING FORWARD. MAINTENANCE REPAIRED AS PER SRM 53-40-30 REPAIR 1 FIG 201.SDR DALA12000386305Frame · crackedDURING INSPECTION, FOUND CABIN UPPER LOBE TENSION TIES AREA BS 1200 STRINGER-9L FRAME WEB AT STRINGER CUTOUT CRACKED. MAINTENANCE REMOVED AND REPLACED CRACKED DOUBLER FRAME AT CABIN UPPER LOBE TENSION TIES AREA BS 1200 STRINGER-9L WITH NEW DOUBLER FRAME AS PSDR DALA12000376305Frame · crackedDURING INSPECTION FOUND CABIN UPPER LOBE TENSION TIES AREA BS 1120 STRINGER-11R FRAME WEB AT STRINGER CUTOUT CRACKED. MAINTENANCE REPAIRED FRAME PER SRM 53-40-07 REPAIR 1 FIG 201.SDR DALA12000366305Tension Tie · crackedDURING INSPECTION, FOUND CRACK AT RIGHT SIDE TENSION TIE AT BS 1200 ON TOP FASTENER ROW, 5TH FASTENER HOLE FROM OUTBOARD LOOKING FORWARD. MAINTENANCE REPAIRED CRACK PER SRM 53-40-03 REPAIR 1 FIG 201.SDR DALA12000356305Tension Tie · crackedDURING INSPECTION FOUND CRACK AT LEFT SIDE TENSION TIE AT BS 1120 ON TOP FASTENER ROW, 4TH FASTENER HOLE FROM OUTBOARD LOOKING FORWARD. MAINTENANCE REPAIRED CRACK PER PER SRM 53-40-30 REPAIR 1 FIG 201.SDR DALA12000346305Frame · crackedDURING INSPECTION, FOUND CABIN UPPER LOBE TENSION TIES AREA BS 1180 STRINGER-9L, FOUND FRAME WEB AT STRINGER CUTOUT CRACKED. MAINTENANCE REMOVED CRACKED FRAME DOUBLER AND FABRICATED NEW DOUBLER PER P/N: 65B26275-3 AS PER DWG65B26275. REFER TO SMALL CONTROLSDR DALA12000586305Shear Tie · crackedDURING INSPECTION FOUND CABIN UPPER LOBE TENSION TIES AREA BS 1200. FOUND SHEAR TIE NEAR STRINGER CUTOUT CRACKED. MAINTENANCE FABRICATED NEW SHEAR TIE AS PER DWG 65B01735. CRACKED SHEAR TIE REMOVED AND NEW FABRICATED SHEAR TIE INSTALLED AS PER SRM 51-40-02.SDR DALA12000446309Connector · damagedDURING INSPECTION FOUND POSITION DOOR 2R FLOOR PROXIMITY LIGHT NOT ILLUMINATED. MAINTENANCE REPAIRED BAD CONNECTOR AND RELAMPED. OPS CHECKED OK.SDR DALA12000436312Connector · dirtyDURING INSPECTION, FOUND SEVERAL FLOOR PROXIMITY EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE CLEANED CONNECTIONS AND REPLACED LAMPS.SDR UALA2012052702944Heat Shield · missingNR 1 ENGINE OIL TANK HEAT SHIELD MISSING UP TO THE FIRST CLAMP. LESS THEN 40 PERCENT. REMOVED DAMAGED HEATSHIELD. INSTALLED REPLACEMENT HEAT SHIELD.SDR DALA12000546305Frame · crackedDURING INSPECTION CRACK WAS FOUND AT RIGHT TENSION TIE BS 1120 ON TOP FASTENER ROW, 8TH FASTENER HOLE FROM OUTBOARD LOOKING FORWARD. MAINTENANCE REPAIRED PER SRM 53-40-30, REPAIR 1 FIG 201.SDR DALA12000526305Frame · crackedDURING INSPECTION FOUND CABIN UPPER LOBE TENSION TIES AREA BS 1140 STRINGER-10R. FOUND FRAME WEB AT STRINGER CUTOUT CRACKED. MAINTENANCE REPAIR CARRIED OUT AS PER SRM 53-40-07 REPAIR 2 FIG 201.SDR DALA1233376312Fuse · inoperativeDURING INSPECTION FOUND RIGHT OVERWING EMERGENCY LIGHT AT MOST FORWARD WON'T TURN ON. MAINTENANCE REPLACED FUSE ON M7919 POWER SUPPLY AND PERFORMED OPERATIONAL CHECKED OK AS PER AMM 33-51.SDR DALA1233216306Splice · corrodedDURING INSPECTION, FOUND CORROSION ON DRAG SPLICE FITTINGS AT BS 960-990, S38L. MAINTENANCE REMOVED CORRODED DRAG SPLICE FITTING. INSTALLED NEW FITTING PER PRI 502620-14AD REV 4.SDR DALA1233146306Skin · damagedDURING INSPECTION FOUND ONE HOLE DAMAGED AT BS 990 STRINGER 39L END FITTING. MAINTENANCE REPAIRED.SDR DALA1233136306Skin · damagedDURING INSPECTION FOUND DOUBLE HOLE (01EA) ON LOWER SKIN AT BS 996 STR-39L. MAINTENANCE REPAIRED.SDR DALA1233366306Skin · crackedDURING INSPECTION, A CRACK WAS FOUND ON BS 980 SKIN. MAINTENANCE REPAIRED PER ERA 502620-14AD.SDR DALA1233356306Frame · crackedDURING INSPECTION, FOUND CRACKS ON FRAME AT BS 800. MAINTENANCE REPAIRED PER ERA 502637-14AD.SDR DALA1233106309Connector · damagedDURING INSPECTION FOUND EMERGENCY LIGHTS INOPERATIVE AT ROW 20-30 LEFT. MAINTENANCE RECONNECTED MODULE PIN AT ROW 20. OPERATIONAL CHECK OK.SDR DALA1232776306Skin · crackedDURING INSPECTION, FOUND A CRACK AT THE NR 5 RIGHT MED CUTOUT, UPPER AFT CORNER, BS 2285. ER/A 502022-14 SECTION I WAS ACCOMPLISHED.SDR DALA1232766301Structure · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE NR 3 RIGHT MAIN ENTRY DOOR, UPPER AFT CORNER, ER/A 502641-14AD SECTION I WAS ACCOMPLISHED.SDR DALA12001276305Skin · crackedDURING INSPECTION FOUND CRACK ON 01 HOLE ON SKIN AT STA 984 STRINGER 38R UNDER LOWER DRAG SPLICE FITTING. MAINTENANCE REPAIRED AS PER PRI 503072-14AD REV 0 TO REV 3 DATED 26 MAY 2012. PRI 503072-14AD REV 0 TO REV 3 FOUND IN COMPLIANCE WITH ER/A 503072-14ADSDR DALA12001226305Bulkhead · crackedDURING INSPECTION, FOUND HORIZONTAL STABILIZER COMPT BS 2598 BULKHEAD LEFT LOWER AFT INNER CHORD CRACKED. MAINTENANCE REPAIRED HORIZONTAL STABILIZER COMPT BS 2598 BULKHEAD LT LOWER AFT INNER CHORD AS PER PRI 503068-14AD REV 0 DATED 23 MAY 2012 16 00 HRS. PRI SDR DALA1232506306Web · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE WEB. MAINTENANCE ACCOMPLISHED ERA 502611-14 SECTION 1 REPAIR.SDR DALA1232276311Light · inoperativeDURING INSPECTION, FOUND FLOOR PATH LIGHT OUT. MAINTENANCE REPLACED EMERGENCY LIGHT POWER SUPPLY PER AMM 33-51. OPS CHECKED OK.SDR DALA1232256311Light · missingDURING INSPECTION, FOUND 66H FLOOR PATH LIGHT ASSY MISSING. MAINTENANCE INSTALLED FLOOR PROXIMITY PATH LIGHTING PER AMM 25-27. OPS TESTED OK.SDR DALA1230936306Floor Support · corrodedDURING INSPECTION, FOUND CORRISION ON MAIN DECK FLOOR STRUCTURE AT APPROX. BS 860 RBL 116. MAINTENANCE REMOVED CORRODED FLOOR SUPPORT AND INSTALLED NEW EWM FLOOR SUPPORT.SDR DALA1230906306Skin · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE NR 3 CABIN WINDOW CUTOUT, LOWER AFT CORNER. A REPAIR WAS INSTALLED PER ER/A 502618-14 SECTION I.SDR DALA1230886306Frame · crackedDURING INSPECTION, FOUND A CRACK ON BS 140 BULKHEAD OUTER RING CHORD. ER/A 503069-14 SECTION I WAS ACCOMPLISHED.SDR DALA1229636305Floorbeam · corrodedDURING INSPECTION FOUND AFT CARGO DOOR SILL AREA, ONE FLOORBEAM UPPER TEE WITH CORROSION. NEW TEE FABRICATED PER DWG 65B04331 REV F. INSTALLED TEE PER SRM 51-40-02.SDR DALA1230456306Web · crackedDURING INSPECTION FOUND CRACK AT THE WEB BETWEEN BS 1240 AND 1260 STR 6 TO 7R. MAINTENANCE REMOVED AREA PER SRM 51-40-02. NEW WEB FABRICATED AS PER DWG 69B04913 REV E. NEW WEB AT MAIN DECK CABIN BETWEEN BS 1240 AND 1260 STR 6 TO 7R AREA INSTALLED AS PER SRM 5SDR DALA1230036306Doubler · crackedDURING INSPECTION FOUND CRACK AT THE TENSION TIE STATION STA1200 RT FRAME DOUBLER. MAINTENANCE REMOVED DOUBLER AND INSTALLED WITH NEW FRAME DOUBLER AS PER B747-400 SRM 51-40-02.SDR DALA1230026306Doubler · crackedDURING INSPECTION FOUND CABIN ZONE C LT STA 1200 TENSION TIE FRAME DOUBLER FOUND CRACKED. MAINTENANCE REMOVED DOUBLER AND INSTALLED NEW FRAME DOUBLER AS PER B747-400 SRM 51-40-02.SDR DALA1229646305Structure · crackedDURING INSPECTION FOUND NR 2 SPOILER CRACKED. NR 2 SPOILER REPLACED PER AMM 27-61-02.SDR DALA1229606315Socket · dirtyDURING INSPECTION FOUND LEFT OVERWING NR 2 POSITION FWD SIDE EMERGENCY LIGHT INOPERATIVE. CLEANED BULB SOCKET AND RELAMPED, OPERATIONAL CHECK OK.SDR DALA1230366305Structure · crackedDURING INSPECTION FOUND NR 6 SPOILER CRACKED. NR 6 SPOILER REPLACED PER AMM 27-62-01.SDR DALA1235556305Floorbeam · corrodedAFT CARGO DOOR SILL FLOORBEAM UPPER CHORD CORRODED OUT OF LIMITS STATION 1840 RBL 56.SDR DALA1229686306Shear Tie · crackedDURING INSPECTION FOUND CABIN ZONE C BS 1180 TENSION TIE FRAME SHEAR TIE CRACKED. MAINTENANCE REMOVED AREA PER SRM 51-40-02. NEW SHEAR TIE CLIP FABRICATED AS PER BOEING DWG 65B01752 REV A. NEW SHEAR TIE CLIP INSTALLED AT CABIN ZONE C STA 1180 TENSION TIE FRSDR DALA1229676306Channel · crackedDURING INSPECTION FOUND CRACK 01 ON TENSION TIE FORWARD CHANNEL AT BS 1200 LT. MAINTENANCE REPLACED AREA AS PER SRM 53-40-30 REPAIR 1 F.SDR DALA1229666306Floor Support · crackedDURING INSPECTION FOUND CRACK AT THE FLOOR SUPPORT WEB UPPER CHORD AT STA 500 TO STATION 520, RBL7.0 AREA REMOVED AS PER SRM 51-40-02. NEW UPPER CHORD ANGLE FABRICATED AS PER DWG 69B1965. INSTALLED NEW UPPER CHORD ANGLE AT CABIN STA 500 TO STA 520 RBL 7.0 ARSDR DALA1229656306Frame · crackedDURING INSPECTION FOUND CRACK AT THE TENSION TIE BS 1220 RIGHT FRAME DOUBLER. MAINTENANCE REMOVED CRACKED DOUBLER AND INSTALLED WITH NEW FRAME DOUBLER AS PER B747-400 SRM 51-40-02.SDR DALA1228916315Light · inoperativeDURING INSPECTION FOUND RIGHT OVERWING NR 3 POSITION FORWARD SIDE EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED OVERWING EMERGENCY LIGHT ASSEMBLY PER AMM 33-51. OPERATIONAL CHECKED OK.SDR DALA1228836306Floor Support · crackedDURING INSPECTION CRACK FOUND AT THE FLOOR SUPPORT WEB UPPER CHORD AT BS 500 TO 520 LBL 67.0 ON FLOOR SUPPORT WEB AREA, REMOVED AS PER SRM 51-40-02. NEW UPPER CHORD ANGLE FABRICATED AS PER DWG 69B19165. NEW UPPER CHORD INSTALLED AS PER SRM 51-40-02.
Back to Boeing 747-451