Boeing 747-451
Service difficulty reports · 2,469
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1219116302Door Frame · crackedDURING HFEC OPEN HOLE INSP ON AFT CARGO DOOR CUTOUT UPPER FORWARD CORNER, HOLES NR 2 AND NR 4 FOUND WITH CRACK INDICATION. AFT CARGO DOOR CUTOUT UPPER FORWARD CORNER WORK CARRIED OUT AS PER PRI 500187-14D REV 0, 1, 2 AND 3 DATED 12 MAR12 TIME 1100HRS. COMPLISDR DALA1219106302Door Frame · crackedDURING HFEC SURFACE INSP ON AFT CARGO DOOR CUTOUT UPPER FORWARD CORNER CRACK FOUND PROPAGATE FROM HOLE NR 2 TO THE EDGE APPROXIMATELY 3/4" AS MARKED. AFT CARGO DOOR CUTOUT UPPER FORWARD CORNER WORK CARRIED OUT AS PER PRI 500187-14AD REV 0, 1, 2 AND 3. REFERSDR DALA1224876304Structure · crackedDURING HFEC SURFACE INSPECTION ON AFT CARGO DOOR CUTOUT UPPER FORWARD CORNER, CRACK FOUND PROPAGATE FROM HOLE NR 2 TO THE EDGE APPROX 3/4" AS MARKED. WORK CARRIED OUT AS PER PRI 501579-14 REV 0 AND PRI 501579-14 REV 1 AND ER/A 501579-14, REPAIR CARRIED OUT RESDR DALA1219476302Sill · corrodedDURING HCK, CORROSION WAS NOTED ON THE LT UPPER DECK EMERGENCY EXIT DOOR SILL, STA 685, STR 13L. ER/A 500558-14 SECTION I WAS COMPLETED AT THAT TIME. FOLLOW ON ACTION IS REQUIRED FOR THIRD STAGE APPROVAL.SDR DALA1217886304Skin · crackedDURING HFEC SURFACE AND OPEN HOLE INSPECTION AT LT NR 3 DOOR UPPER AFT CORNER FOUND CRACK ON SKIN SURFACE AND ONE HOLE CRACK INDICATION. INDICATE CRACK CLASSIFICATION AS SMALL AND MEDIUM. REPAIRED PER PRI 501583-14.SDR DALA1217866304Skin · crackedDURING HFEC SURFACE AND OPEN HOLE INSPECTION AT RT NR 3 DOOR UPPER AFT CORNER FOUND CRACK ON SKIN SURFACE, INDICATE CRACK CLASSIFICATION AS SMALL. REPAIRED PER PRI 501578-14.SDR DALA1218626302Seat Track · corrodedFLATBED MODIFICATION, DURING FLOORBOARD REMOVAL, CORROSION FOUND ON LBL 98.59 SEAT TRACK, BS 520 & STA 540. INTERCOSTAL REMOVED AND REPAIRED AT LBL 98.59 BS 520 & BS 540 PER ER/A 500561-14 REV.SDR DALA1219486304Floorbeam · crackedAFT CARGO DOOR SILL AREA, ONE FLOORBEAM UPPER CHORD FOUND CRACK AT BS 1840 RBL 58. REMOVED DAMAGED BEAM, FABRICATED NEW FLOORBEAM PER DRAWING 65B07267 REV D. INSTALLED NEW FLOORBEAM PER SRM 51-40-02.SDR DALA1217696304Stringer · crackedNR 3 PYLON INBOARD SIDE STRINGER AT NACELLE STA 346.402 FOUND CRACKED AT AROUND FASTENER HOLE AREA. ENTERED AND DEFERRED FOR SDR REPORTING. REPAIRED PER PRI 501588-14.SDR DALA1217676304Skin · crackedDURING HFEC SURFACE INSPECTION ON RT NR 3 DOOR CUTOUT UPPER AFT CORNER, CRACK INDICATION FOUND ON FUSELAGE SKIN AREA AS MARKED. REPAIRED PER PRI 501578-14.SDR DALA1217656304Skin · crackedDURING HFEC SURFACE INSPECTION ON LT NR 3 DOOR CUTOUT UPPER AFT CORNER, CRACK INDICATION FOUND ON FUSELAGE SKIN AREA AS MARKED. REPAIRED PER PRI 501583-14. (LP 0443605)
SDR DALA1217686304Skin · crackedINSPECTION FOUND HOLE CRACK 1 EA ON SKIN AT STA 982 STR-38R UNDER LWR DRAG SPLICE FITTING (NR 6 HOLE FROM STA 990 (EDGE OF SKIN) AS MARKED. SKIN REPAIR AND INSTALLATION CARRIED OUT AS PER B747-400 SRM 53-20-01 FIG 201 AND PRI 501602-14AD REV 0. PRI 501-602-14SDR DALA1219076304Bulkhead · out of limitsFOUND GAPS IN HOLES NR 9, 11, & 12 OF BULKHEAD. REPAIR CARRIED OUT AS PER SB747-53A2390 R1 FIG 28 AND PRI 1501571-14 REV 1.SDR UALA2012032201818Wire · damagedAPU SHUT DOWN. FOUND WIRE FROM PIN A12 CONNECTOR DM7847CA TO CONNECTOR D95004 PIN E SHORT TO SHIELD. ALSO SEVERAL WIRES IN SAME HARNESS FOUND DAMAGED. RPL'D APU BAY HARNESS W7242 AND CLAMPS WDM AND MM. APU START, RUN, AND SHUTDOWN NORMAL.SDR DALA1217336304Seat Track · corrodedMAIN DECK CABIN SEAT TRACK AT BS 460 & LBL 68 FOUND CORROSION AS MARKED. ENTERED AND DEFERRED FOR SDR REPORTING. CORRODED SEAT TRACK AT CABIN BS460 LBL 68 AREA REMOVED AS PER B747-400 SRM 51-40-02. NEW SEAT TRACK FABRICATED AS PER BOEING 140U5286 REV A. NEWSDR DALA1217326304Seat Track · corrodedMAIN DECK CABIN SEAT TRACK AT BS 460 & LBL 91 FOUND CORROSION AS MARKED. ENTERED AND DEFERRED FOR SDR REPORTING. CORRODED SEAT TRACK AT CABIN BS460 LBL 91 AREA REMOVED AS PER B747-400 SRM 51-40-02. NEW SEAT FABRICATED AS PER BOEING DWG140US5286 REV A. NEW SESDR DALA1217316304Seat Track · corrodedMAIN DECK CABIN SEAT TRACK CROWN AT STA 580 & 91.67 FOUND CORROSION AS MARKED. ENTERED AND DEFERRED FOR SDR REPORTING. NEW SEAT TRACK FABRICATED AS PER BOEING DWG65B28626 REV NEW. NEW SEAT TRACK AT CABIN STA 580 LBL 91.67 AREA INSTALLED AS PER B747-400 SRM 5SDR DALA1217306304Frame · crackedSTA 1160, S-9R FOUND FRAME CRACK AFTER REMOVE FRAME DOUBLER FOR NRC 240-050. ENTERED AND DEFERRED FOR SDR REPORTING. STA 1160 S-9R FRAME CRACKED AREA REPAIRED AS PER B747-400 SRM 53-40-07 REPAIR 3 FIG 201.SDR DALA1217366306Light · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY DOOR EXIT LIGHT AT DOOR 4R WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE LIGHT ASSEMBLY TO BE DEFECTIVE AND REPLACED IT. SYSTEM OPERATION WAS NORMAL AFTER THE LIGHT ASSEMBLY WAS REPLACED.SDR DALA1221516304Frame · crackedFRAME STA 1255, BETWEEN S-4L TO S-5L FOUND ONE WEB CRACK AS MARKED. CRACKED FRAME WEB AT STA 1255 BETWEEN S-4L TO S-5L AREA REMOVED AS PER SRM 51-40-02. NEW WEB FABRICATED AS PER DWG 65B04913 REV E. NEW FRAME WEB AT STA 1255 BETWEEN S-4L TO S-5L AREA INSTALSDR UALA2012032201828Apu · shutdownAPU AUTO SHUTDOWN. NEED MORE TIME FOR T-S.SDR DALA1217386316Connector · disconnectedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHT AT SEAT 22H WAS FOUND TO BE INOPERATIVE. MAINTENANCE CONNECTED THE ELECTRICAL CONNECTOR OF THE FLOOR PROXIMITY LIGHT. SYSTEM OPERATION WAS NORMAL AFTER THE CONNECTOR WAS SECURED.SDR DALA1216386304Door Frame · crackedDURING HFEC OPEN HOLE INSP ON AFT CARGO DOOR CUTOUT UPPER FWD CORNER, HOLES NR 2 AND NR 4 FOUND WITH CRACK INDICATION.
WORK CARRIED OUT AS PER PRI 501579-14 REV 0 AND PRI 501579-14 REV 1 FOUND IN COMPLIANCE WITH ER/A 501579-14, JOB COMPLETED.
SDR DALA1217006308Battery · dischargedDURING A MAINTENANCE VISIT, THE UPPER DECK EMERGENCY FLASH LIGHT INDICATOR WAS NOT ILLUMINATED. MAINTENANCE REPLACED THE FLASHLIGHT BATTERY AND INSTALLED THE SEAL. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY WAS REPLACED.SDR DALA1216136304Seat Track · corrodedMAIN DECK CABIN SEAT TRACK AT BS 2310 & LBL 11 FOUND CORROSION. REMOVED AS PER B747-400 SRM 51-40-02. NEW SEAT TRACK FABRICATED AS PER BOEING DWG146US5295 REV AND INSTALLED AS PER B747-400 SRM 51-40-02.SDR DALA1216116304Seat Track · corrodedMAIN DECK CABIN SEAT TRACK AT STA 2190-2270 & RBL 11. FOUND CORROSION AS MARKED. REPAIRED AS PER PRI 501573-14.SDR DALA1216096304Floor Support · corrodedMAIN DECK CABIN FLOOR SUPPORT STRUCTURE UPPER & LWR SURFACE AT BS 575-50 & LBL 98 FOUND CORROSION. REPAIRED PER PRI 501574-14.SDR DALA1216126304Seat Track · corrodedMAIN DECK CABIN SEAT TRACK AT STA 2160-2240 AND LBL 11 FOUND CORROSION AS MARKED. REPAIRED AS PER PRI 501573-14 REV 0.SDR DALA1216106304Seat Track · corrodedMAIN DECK CABIN SEAT TRACK AT STA 2190-2270 & RBL 33 FOUND CORROSION AS MARKED. CORRODED SEAT TRACK SECTION FROM STA 2190 TO 2270 RBL 33 REPAIRED AS PER PRI 501573-14 REV 0.SDR DALA1216146304Seat Track · corrodedMAIN DECK CABIN SEAT TRACK AT BS 2310 & RBL 11 FOUND CORROSION. REMOVED AS PER B747-400 SRM 51-40-02. NEW SEAT TRACK FABRICATED AS PER BOEING DWG146US5295 REV. AT MAIN DECK CABIN BS 2310 RBL 11 AREA INSTALLED AS PER B747-400 SRM 51-40-02.SDR DALA1215526305Battery Pack · dischargedDURING A MAINTENANCE VISIT, THE UPPER DECK FLOOR AND CEILING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND PACK M7919 AT DOOR 3L CAUSING THE FAULT. MAINTENANCE REPLACED THE BATTERY PACK AT 3L DOOR. SYSTEM OPERATION WAS NORMAL AFTER THE POSDR DALA1215396305Battery Pack · dischargedDURING A MAINTENANCE VISIT, THE CEILING EMERGENCY LIGHTS ON THE LEFT AND RIGHT SIDE FROM ROWS 22 TO 31 WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND PACK M7919 AT DOOR 3L CAUSING THE FAULT. MAINTENANCE REPLACED THE POWER PACK AT 3L DOOR. SYSTEM OPERATION SDR DALA1215376305Power Supply · inoperativeDURING A MAINTENANCE VISIT, THE 3R DOOR EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY AT 3R DOOR. SYSTEM OPERATION WAS NORMAL AFTER THE POWER SUPPLY WAS REPLACED.SDR DALA1214966313Wire · looseDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHTS FROM ROWS 22 THROUGH 31 ON THE RIGHT SIDE WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE WIRE LOOSE AT SEAT 24H AND SECURED IT. SYSTEM OPERATION WAS NORMAL AFTER THE WIRE WAS SECURED.SDR DALA1214956312Connector · looseDURING A MAINTENANCE VISIT, THE EMERGENCY ESCAPE PATH LIGHT BY LAVATORY DOOR 4L WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE WIRE CONNECTOR LOOSE BY SEAT 43C AND RECONNECTED IT. SYSTEM OPERATION WAS NORMAL AFTER THE CONNECTOR WAS RECONNECTED.SDR DALA1213666302Intercostal · crackedFLATBED MOD, MAIN DECK ZONE B, STA 760 TO 740, LBL 65, EDGE CRACK FOUND ON INTERCOSTAL DURING OPENING OF FLOORBOARD. CRACKED INTERCOSTAL AT MAIN DECK ZONE B STA 740 TO 760 LBL 65 AREA REMOVED AS PER B747-400 SRM 51-40-02 NEW INTERCOSTAL FABRICATED AS PER BOSDR DALA1213646312Fuse · openDURING A MAINTENANCE VISIT, THE OVERWING EMERGENCY LIGHT ON THE RIGHT SIDE WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE POWER SUPPLY FUSE OPEN AND REPLACED IT. SYSTEM OPERATION WAS NORMAL AFTER THE FUSE WAS REPLACED.SDR DALA1213406302Sill · corrodedUPPER DECK LEFT DOOR CUTOUT SILL UPPER FACE FOUND WITH CORROSION AS INDICATED. UPPER DECK LT DOOR CUTOUT LOWER SILL UPPER FACE CORROSION REMOVED AS PER B747-400 SRM 51-10-02. CORRODED AREA REPAIRED AS PER PRI 500558-14 REV 0, REV 1, REV 2 AND REV 3 DATED 21MASDR DALA1212826302Intercostal · crackedMAIN DECK CABIN, STA 1220, RBL 100 TO RBL 127, OVERWING INTERCOSTAL WEB, CRACK OF APPROXIMATELY 4" IN LENGTH FOUND FROM LOWER CHORD. MAIN DECK CABIN STA 1220 RBL 100 TO RBL 127 OVERWING INTERCOSTAL WEB CRACK AREA REPAIRED. REFER TO WORKCARD 5313-01014-02H (JSDR DALA1212816303Seat Track · damagedCABIN - STA 1770 TO STA 1870 RBL 98.58 REPAIR AS PER BOEING SRM 53-00-52 REPAIR 9, FIG 201 STEP 11, REPAIR SEAT TRACK TO CARRY OUT ANODIZE ON CROWN INNER FLANGES. ALTERNATE FINISHING PER PRI 500198-14AD REV DATED 27FEB2012. PRI 500198-14AD REV 0 COMPARED W/ERSDR DALA1212786305Battery · dischargedDURING A MAINTENANCE VISIT, THE EMERGENCY LIGHT AT FIRST/SECOND OF THE OVERWING ESCAPE SLIDE WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY CHARGER. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY WAS REPLACED. (2012-00101)SDR DALA1212096302Bulkhead · damagedCABIN ZONE A -STA 140 FWD BULKHEAD WEB BETWEEN STR 22R-23R FOUND WITH SHORT EDGE MARGIN. REPAIRED AS PER PRI 500565-14 REV 0 DATED 05MAR12.SDR DALA1218636302Web · crackedLT BLG W/W- STA 1480 O/B WEB FOUND CRACK AT ABOUT STR 34L. LT BLG W/W STA 1480 O/B WEB REPAIRED AS PER B747-400 SRM 53-40-08 REPAIR FIGURE 1.SDR DALA1212086309Fuse · blownDURING A MAINTENANCE VISIT, THE EMERGENCY EXIT SIGN AT DOOR R3 LOWER WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY FUSE. SYSTEM OPERATION WAS NORMAL AFTER THE FUSE WAS REPLACED.SDR DALA1211726301Fuse · defectiveDURING A MAINTENANCE VISIT, THE 2 LOWER EMERGENCY LIGHTS AT THE WING TRAILING EDGE WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE 3 FUSES DEFECTIVE IN THE POWER SUPPLY AND REPLACED THEM. SYSTEM OPERATION WAS NORMAL AFTER THE FUSES WERE REPLACED.SDR DALA1211716301Wire · disconnectedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHTS AT ROWS 10-12 ON THE RIGHT WERE FOUND TO BE INOPERATIVE. MAINTENANCE RECONNECTED THE WIRES AT ROW 10. SYSTEM OPERATION WAS NORMAL AFTER THE WIRES WERE RECONNECTED.SDR DALA1211706301Wire · disconnectedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHT AT DOOR 3L WAS FOUND TO BE INOPERATIVE. MAINTENANCE RECONNECTED THE WIRES. SYSTEM OPERATION WAS NORMAL AFTER THE WIRES WERE RECONNECTED.SDR UALA2012022701165Light · inoperativeEMERGENCY LIGHT INOP CROSS AISLE DOOR 2R AND 2L. RELAMPED EMERGENCY LIGHT.SDR DALA1211776313Bracket · damagedAT STA 700 LBL 19 IN FWD CARGO PDU DISCONNECT BRACKETS FOR STA 930 AND 830 ARE DAMAGED. INSTALLED NEW BRACKETS, REF ERA 500713-14.SDR UALA2012022701166Light · inoperativeEMERGENCY LIGHT INOP FWD SILL DOOR 2 LEFT. RELAMPED EMERGENCY LIGHT.
Back to Boeing 747-451