Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012080704238Contact · dirtyENGINE BOTTLE 1 DISCHARGE LIGHT INOPERATIVE. TROUBLESHOT PANEL LIGHT SWITCH BY SWAPPING WITH RIGHT SWITCH NEEDS NEW ENGINE FIRE PANEL. CLEANED CONTACTS AND HOUSING ASSY FOR ENGINE BOTTLE 1 DISCHARGE SWITCH LIGHT. OP'S CHECKED GOOD.SDR UALA2012080704237Floorbeam · damagedBS 1620 FLOORBEAM, RBL 44 DAMAGED. REMOVED DAMAGED UPPER TEE, ACCOMPLISHED HFEC. FABRICATED AND INSTALLED REPAIR PARTS PER ECRA 5310-05536. MAJOR REPAIR.SDR UALA2012080704236Pressure Deck · corrodedCORROSION FOUND ON AFT CABIN PRESSURE DECK FLOOR AT STA 1681, LBL 8 TO RBL 62. REMOVED DAMAGED AREAS, FABRICATED REPAIR PARTS, INSTALLED REPAIR PER ECRA 5330-04259. MAJOR REPAIR.SDR UALA2012080704258Module · faultedSTABILIZER TRIM EICAS ILLUMINATED ON SHORT FINAL WENT OUT ON TAXI IN WITH CENTER STABILIZER SWITCH IN CUTOUT. MOVING THE STABILIZER USING THE RIGHT HYDRAULIC SYSTEM STABILIZER TRIM LIGHT ILLUMINATES. PERFORMED FIM 27-09-00 FIG 103. NO MSG PER SHEET 8 BLOCK SDR UALA2012081304461Door Frame · corrodedBS 1681 R4 DOOR FRAME HAS CORROSION OUT OF SRM LIMITS. INSTALLED INTERIM REPAIR IN REF TO ECRA 5310-05554.SDR UALA2012080704249Unknown · odorINTERMITTENT STRONG ELECTRICAL ODOR EMANATING FROM AREA FROM 2L TO MID CABIN. FLIGHT ATTENDANT DETECTED AN ELECTRICAL OR RUBBER ODOR, NO SMOKE, LOCALIZED AT DOOR 2L AND MID LAV, ODOR INTERMITTENT LIGHTS WERE OFF. INSPECTED LAVATORY AND SIDEWALL BALLAST AND GSDR UALA2012080604221Wire · crimpedNR 1 AUDIO SELECTOR PANEL LIGHTING FAULTY (VOLUME CONTROL, ETC). (01=CAPT, 02=FO, 03=OBS). SUPPLEMENTAL DATA UPDATE, TROUBLESHOT SYSTEM. FOUND FAULTY CRIMP ON WIRE NR W2297-001-16, RETERMINATED WIRE AT TB159. CAPTAIN AUDIO SELECT PANEL TESTED OK.SDR UALA2012080604190Pressure Panel · corrodedBS 1681 RBL 33 AFT PRESSURE DECK WEB HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED PRESSURE DECK REPAIR IAW ECRA 5330-04259.SDR UALA2012080604189Floorbeam · corrodedBS 1600 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED FLOORBEAM UPPER TEE REPAIR BETWEEN BL 0 AND RBL 11 IAW ECRA 5310-05556.SDR UALA2012080604188Floorbeam · corrodedBS 1661 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED FLOORBEAM UPPER TEE REPLACEMENT IAW ECRA 5310-05536 REPAIR 4.SDR UALA2012080604186Floorbeam · corrodedBS 1681 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED FLOORBEAM UPPER TEE REPLACEMENT IAW ECRA 5310-05557.SDR UALA2012080604184Skin · damagedCARGO DOOR HAS PREVIOUS BLEND AREA ON EXTERIOR SKIN 12 INCHES FROM BOTTOM AND 10 INCHES FROM TRAILING EDGE. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 52-30-01 REPAIR 4.SDR UALA2012080604183Skin · damagedCARGO DOOR EXTERIOR SKIN HAS TWO DRILL MARKS 24 INCHES FROM BOTTOM, AND 1 INCH FROM TRAILING EDGE. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 52-30-01 REPAIR 4.SDR UALA2012080604181Frame · corrodedBS 1681 FRAME LOWER SECTION HAS CORROSION OUT OF SRM LIMITS IAW SCAL LP 9974494. INSTALLED PERMANENT REPAIR.SDR UALA2012080604177Light · inoperativeFOUND AFT EMEGENCY LIGHT NOT WORKING. REPLACED EMERGENCY LIGHT.SDR UALA2012080604187Floorbeam · corrodedBS 1640 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED UPPER TEE REPLACEMENT IAW ECRA 5310-05536 REPAIR 5.SDR UALA2012080704243Module · faultyCREW REPORTS STAB TRIM EICAS MSG. REPLACED RT STAB TRIM POSITION MODULE PER MM, OP CHECKED OK. PERFORMED MCDP GND TEST 65 STAB TRIM OP CHECKED OK. PERFORMED MCDP GND TEST 30 PER MM 22-00-03 FIG 117, OP CHECKED OKAY.SDR UALA2012080604175Skin · corrodedRT HORIZONTAL STAB SKIN AT HSBL 229 ABOVE THE REAR SPAR HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED A PERMANENT REPAIR.SDR UALA2012080604173Frame · corrodedAFT CARGO FRAME HAS CORROSION ON UPPER CAP STA 1480 JUST OUTBOARD OF RT TRANS PANEL. INSTALLED PERMANENT REPAIR.SDR UALA2012080604171Frame · corrodedAFT CARGO LWR LOBE FRAME STA 1460 HAS CORROSION ON FWD SIDE AT LWR ATTACH POINT FOR THE SHEAR CLIP BTWN BL- 0 AND RBL-4. INSTALLED PERMANENT REPAIR.SDR UALA2012080604168Idg · failedLEFT GENERATOR DRIVE DISCREPANCY, RETURNED TO FIELD. LEFT ENGINE FUEL-OIL HEAT EXCHANGER REMOVED PER MM THRU PAGE 410 PARA 8. INSTALLED LT FUEL-OIL HEAT EXCHANGER PER MM. CHECKED DPI AND FILTER FOUND DPI NOT EXTENDED OR CONTAMINATION IN FILTER OR OIL. INSTSDR UALA2012080604159Relay · malfunctionedSTATUS MESSAGE POWER TRANSFEER UNIT. TROUBLESHOT PER FIM 29-22-00 FIG 1 04. REPLACED RELAY RAN BOTH ENGINES AND NO EICAS MESSAGE.SDR UALA2012080304151Fan · odorSMOKE IN FWD GALLEY OVEN, FLIGHT DIVERTED. FOUND OVEN NR 107 UPPER FAN WITH BURNT ELECTRICAL SMELL. REMOVED OVEN AND CHECKED PINS FOR ANY DAMAGE, FOUND NONE. CHECKED GALLEY CIRCUIT BREAKERS IN COCKPIT AND IN E/E COMPARTMENT, NONE WERE TRIPPED. OPERATED REMSDR UALA2012080604220Circuit Card · wrong partGENERATOR DRIVE DISCONNECT LIGHTS ON OVERHEAD PANEL ARE ILLUMINATED DIMLY, BUT GENS WORK NORMALLY. FOUND WRONG CIRCUIT CARDS INSTALLED ON DRIVE LIGHT SWITCHES (S1 AND S2). INSTALLED CORRECT (LED) CIRCUIT CARDS. DIM LIGHT WITH ENGINES RUNNING PROBLEM IS CORRSDR UALA2012080804313Circuit Card · wrong partGEN DRIVE DISC LIGHTS ON OVERHEAD PANEL ARE ILLUMINATED DIMLY, BUT GENS WORK NORMALLY. FOUND WRONG CIRCUIT CARDS INSTALLED ON DRIVE LIGHT SWITCHES (S1&S2). INSTALLED CORRECT (LED) CIRCUIT CARDS. DIM LIGHT WITH ENGINES RUNNING PROBLEM IS CORRECTED.SDR UALA2012080304150Detector · faultedFWD CARGO DET 1 AND 2 BOTH LOOPS SHOW FAULT, CYC BREAKERS. NO MESSAGE .SDR UALA2012080604213Generator · faultedLEFT GENERATOR OFF CHRONIC PROBLEM RESET OKAYSDR UALA2012080604214Liner · damagedNR 2 ENGINE FAN SOUND ABSORBING LINER HAS A HOLE IN IT AT THE 4 O'CLOCK POSITION IT IS .750 INCH BY .750 INCH, THE HOLE IS ALSO .825 INCH DEEP. SUPPLEMENTAL DATA UPDATE, LARGE AMOUNT OF SOFT AND HARD POTTING MATERIAL IN HOLE FROM EARLIER ATTEMPS TO REPAIR. WSDR UALA2012080604215Skin · delaminatedNR 5 SLAT TRAILING EDGE WEDGE HAS DELAMINATION ON INBOARD AFT END, SIZE IS 8 INCH-8 INCH. REMOVED NR 5 SLAT P/N 114N30 02-79A SN A1-0291. WAITING ON INSPECTION OF TRACKS AND AREA CLEARANCE TO INSTALL NEW FLAP. INSTALLED SLAT. COMPLETED INSTALL AND RIG PESDR UALA2012080104129Light · looseEMERGENCY LIGHT STRIP IN FRONT OF LAV AT DOOR 2L IS PULLED LOOSE. CHECKED EMERGENCY ESCAPE LIGHTING IN FRONT OF MID LAV DOOR. FOUND STRIP SECURE AND OPERATIONAL.SDR C8GA20120731009Slat · delaminatedDURING SERVICE CHECK FOUND LEFT INBOARD SLAT DELAMINATED. REMOVED AND REPLACED NR 5 SLAT IAW B-757 AMM 27-81-01, OP'S CK GOOD. INSTALLED P/N 114N3002-101, S/N A10091.SDR UALA2012073004116Exciter · inoperativeAPU HAD SHUTDOWN, FAULT LIGHT ILLUMINATED AND EICAS MESSAGE. APU FAULT DISPLAYED. THREE FAILED START ATTEMPTS ALL HUNG AT 25 PCT RPM BEFORE AUTO ABORT. FOUND NO SPARK ON APU ENGINE START, REPLACED EXCITER BOX AND LEAD, OPS CHECKED GOOD.SDR UALA2012073104123Floor Panel · puncturedTWO PUNCTURES IN AFT CARGO BAY FLOOR PANEL AT STA 1402. FIRST HOLE 4X5 AND SECOND HOLE 2.5 X .5. REPAIRED DAMAGED FLOOR PANEL PER MM 53-30-98 REPAIR 4.DSDR UALA2012080804268Seal · leakingPRESSURE LEAK R10DOOR FROM TOP L AFT TO TOP MID DOOR. SECURED SEAL AND PRESSURIZE AIRCRAFT. FOUND NO LEAK AT 4.TO 5.SDR UALA2012080804270Cover · missingAT DEPARTURE, CAPTAIN REPORTED SLIDING WINDOW UNDERNEATH THE LOCK HANDLE TRACK COVER MISSING. REPLACED MISSING LOCK HANDLE TRACK COVER.SDR UALA2012080804267Control Head · failedACARS CONTROL HEAD ON PEDESTAL FAILS TO DIM BRIGHT CORRECTLY. REPLACED CONTROL HEAD PER AMM. OPS CHECKED GOOD.SDR UALA2012080804266Light · brokenEMERGENCY LIGHTS INOPERATIVE FROM ROW 3 TO DOOR 2L. REPAIRED BROKEN EMERGENCY LIGHT AT DOOR 2L TO ROW 3. OPS CHECKED NORMAL.SDR UALA2012080804265Light · looseEMERGENCY LIGHT LOOSE SEATS 11C AND 12C. SECURED LOOSE LIGHT.SDR UALA2012073004108Light · faultyR1 DOOR SLIDE LIGHT DOES NOT ILLUMINATE WHEN DOOR IS ARMED. REPLACED LIGHT ASSY. SYSTEM OPS, CHECKED NORMAL.SDR UALA2012080804269Lamp · inoperativeR1 AND R2 DOOR SLIDE ARM LIGHTS NOT ON WHEN DOOR ARMED. RELAMPED , CHECKED OKAY.SDR UALA2012073004097Control Rod · out of adjustDURING CONTROL CHECK, ELEVATORS SPLIT AND NOT NEUTRAL. FOUND RT ELEVATOR RIG PIN ES T9 UNABLE TO FREELY PUT IN MIDDLE PCA AND RT ELEVATOR TRAILING EDGE .25 INCH FROM LOCATING HOLE ON INDEX PLATE. ADJUSTED RT ELEVATOR PCA INPUT CONTROL ROD AND POWER CONTROL ASDR UALA2012073004092Pressure Switch · inoperativeRT HYD PUMP PRESSURE SWITCH NOT FUNCTIONING. REPLACED RT PRESSURE SWITCH, OPS CHECKED GOOD.SDR UALA2012073004098Frame · corrodedAFT CARGO BAY LOWER BILGE STRUCTURE, FWD FACE OF FRAME EXFOLIATED BS 1400, BL 0 - RBL 24. REPAIRED BS 1400 FRAME WEB, BETWEEN S27R-S30 IAW REO-G15110 REV C & ECRA 5362-01022.SDR UALA2012073004117Battery · faultySTATUS MESSAGE MAIN BATTERY CHARGER DISPLAYED IN FLT. REPLACED "MAIN BATTERY" PER AMM.SDR UALA2012073004111Frame · damagedAFT CARGO COMPARTMENT LOWER BILGE STRUCTURE, FWD FACE OF FRAME EXFOLIATED BS 1400, RBL 0-RBL 24. ACCOMPLISHED INTERIM REPAIR PER TIMCO REO-G15110 REV C AND ECRA 5362-01022. REPAIR BS 1400 FRAME WEB, BTWN S27R-S30 MUST RECEIVE NEW ACCOMPLISHED ON NR 40369. PSDR UALA2012072704070Warning Light · false activationAFTER TAKEOFF, RECEIVED STATUS MESSAGE RT ENGINE SEC CONT. MESSAGE CLEARED WHILE ACCOMPLISHING PRE-FLIGHT, AND HAS NOT RETURNED. OK TO CONTINUE.SDR UALA2012073004107Light · inoperativeSLIDE ARMED LIGHT AT 4R DOES NOT ILLUMINATE WITH SLIDE POSITIONED TO ARM. FOUND FWD GIRT BAR SLIDER DETACHED. REATTACHED FWD FOOT AND OPERATED SEVERAL TIMES. LIGHT STILL DOES NOT ILLUMINATE. REMOVED INSTALLED PINS FOR TROUBLESHOOTING. FOUND SLIDE LIGHTS SDR UALA2012073004101Floorbeam · corrodedAFT CABIN FLOORBEAM HAS CORROSION BS 1680 BL 0 - RBL 30. REPAIRED FLOORBEAM PER REO-G15097 REVC AND ECRA 5365-01067.SDR UALA2012073004100Skin · corrodedFUSELAGE SKIN CORRODED AT BS 1393, BETWEEN S29 - 30L, ACCOMPLISHED SKIN REPAIR BS 1393-1401 STR 28L AND 29R PER REO-G15092 REV A AND UA ECRA 5360-01214.SDR UALA2012072704068Structure · damagedLEFT WING INBOARD FLAP, OUTBOARD AFT FAIRING, FWD INBOARD MOUNT BRACKET HAS PULLED RIVETS AND ELONGATED HOLE. REPAIRED.
Back to Boeing 757-222