Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011102405754Actuator · defectiveON LANDING AUTOSPEED BRAKES ONLY DEPLOYED PARTIALLY 50 PERCENT. NO TIME. REPLACED AUTOSPEED BRAKE ACTUATOR & K217 & K218 RELAYS. OPS CHECKS NORMAL.SDR UALA2011102405711Floorboard · buckledCABIN CARPET BUCKLE DOOR-2R MID-CABIN FWD GALLEY. CREW COMMENTS: GALLEY FLOOR HAS LARGE DENT NEAR DOOR 2R. TEMP REPAIR FOR FLOORBOARD 4357211-123 PG 801, STAINLESS STEEL SHEET USED WITH SEALANT. SHOULD RPLC FLOORBOARD AT NEXT C CHECK. REMOVED AND REPLACEDSDR UALA2011102105699Light · inoperativeEMERGENCY LIGHT AT SEAT 18C AND 21C INOPERATIVE. REPLACED EMERGENCY LIGHT. OPS CHECKED OKAY.SDR UALA2011102105694Shutoff Valve · malfunctionedDURING DESCENT LEFT DUCT PRESSURE OSCILLATED BETWEEN 5PSI & 30PSI. RIGHT PRESSURE WAS STEADY. REPLACED HIGH STAGE PILOT VALVE AND PRSOV REGULATOR VALVE. RAN ENGINE AT IDLE, NO FLUCTUATION VISIBLE.SDR UALA2011102105707Leg Assy · dislodgedSEATS 32 ABC LOOSE FROM FLOOR REINSTALLED INBD LEG. CHECKED LOCK, SECURE ON OTBD LEG.SDR UALA2011102105695Turbine Case · crackedNR 2 ENGINE 3RD STAGE LPT HAS L/E CRACK THAT IS LESS THAN .125 IN LENGTH. REPLACED ENGINE.SDR UALA2011102005678Door Frame · leakingLOUD PRESSURIZATION LEAK 4R. FOUND REN AND SEALANT MISSING FROM LOWER DOOR FRAME AREA. REPAIRED AREA PER GNMM. ACCOMPLISHED PRESSURIZATION TEST. NO LEAKS FOUND.SDR UALA2011101905667Filter · odorBAD ODOR OVER ENTIRE CABIN AND COCKPIT, DURING FLT AND ON GROUND. REPLACED RECIRCULATION FILTER IAW AMM.SDR UALA2011102005684Connector · damagedLEFT SLIDE BOTTLE PRESS WILL NOT TEST. BOTTLE PRESSURE VERIFIED. READS 2725. FOUND PRESSURE SWITCH ON BOTTLE TO BE OPEN. CONDUCTED TROUBLESHOOTING OF LEFT INFLATION BOTTLE PRESSURE TEST LIGHT. FOUND CONNECTOR D5530 LEFT SLIDE BOTTLE PRESSURE, INTERMITTENT, SDR UALA2011102105706Link · wornL2 DOOR UPPER HINGE LINK WORN. REMOVED AND REPLACED L2 DOOR UPPER HINGE LINK PER MM.SDR UALA2011101905669Structure · damagedLOWER FUSELAGE AT BS 512 BETWEEN STR 28R AND STR 29R IS DENTED AND GOUGED. DENT IS WITHIN LIMITS IAW B757 SRM 53-00-01. GOUGE WAS REMOVED BY DRILLING A .187 DIAMETER HOLE IAW B757 SRM 53-00-01. HFEC INSPECTION REVEALED NO DAMAGE IAW B757 NDTM PART 6 51-00-1SDR UALA2011101905659Line · leakingFLUID LEAK FROM LEFT ENGINE PYLON DRAIN TUBE. LOCATED ON LOWER AFT CORNER OF ENGINE PYLON. MAINT TEXT: FOUND LARGE HYD LINE DRIPPING INSIDE AFT SIDE OF PYLON. UNION AND 'B' NUT VISIBLY DRIPPING. IT APPEARS THAT AFT PYL ON TRAILING EDGE PANEL NEEDS TO BE REMSDR UALA2011101905645Stop Pin · out of adjustDOOR 1L HANDLE MOVES IN FLT. ADJUSTED DOOR STOP PINS PER MM. PRESSURIZED ACFT TO 4 PSI, DOOR 1L HANDLE STILL MOVES SLIGHTLY.SDR UALA2011101805636Switch · faultySLIDE ARM ON WITH SLIDE DISARMED AT 3L. *SUPPLEMENTAL DATA UPDATE* CYCLED DOOR FOUND PROX SWITCHES CLEAN, BUT LIGHT STAYS ON. REPLACED SWITCH S10223 AND TESTED OKAY.SDR UALA2011101905649Probe · faultyFUEL QTY TOTALIZER AND CENTER TANK INDICATORS ARE BLANK. FUEL QTY PROCESSOR FAULTING CTR TANK DENSITOMETER. FOUND FQPU FAULT CODE 76 CTR TANK PROBE 6. REPLACED PROBE #6. AFTER REPLACEMENT NO FAULT CODES NOTED.SDR UALA2011101705634Line · leakingDIRTY SOCK SMELL AFTER TAKEOFF. REPEAT WRITEUP. ACP'D NR 1 ENGINE CHARGE. FLUID LEAK FROM LEFT ENGINE PYLON DRAIN TUBE. LOCATED ON LOWER AFT CORNER OF ENGINE PYLON. FOUND LARGE HYD LINE DRIPPING INSIDE AFT SIDE OF PYLON. UNION AND B-NUT VISIBLY DRIPPING. SDR UALA2011101705632Audio Panel · failedCAPTAIN'S MICROPHONE FROM O2 MASK NOT COMING THRU SPEAKER. REPLACED AUDIO CONTROL PANEL, OPS OKAY.SDR UALA2011101705633Lens · missingSLIDE LIGHT MISSING FROM DOOR 4R. REPLACED MISSING SLIDE ARMED LENS CAP TO DOOR 4R.SDR UALA2011101705601Actuator · faultyRUDDER FAILED TO TRIM IN EITHER DIRECTION. REPLACED RUDDER TRIM ACTUATOR PER MM.SDR UALA2011101705585Oil System · lowAPU FAULT AND SHUTDOWN TWICE AFTER LANDING. BITE CHECK ECU FAULTS GEN FILTER CLEANED PRESS SW, NO HELP. GEN FILTER DPI IS NOT POPPED. SEE HISTORY. FOUND OIL ONE QT LOW. ECU BITE HAD NO FAULTS RECORDED. START AND RUN FOUR TIMES FOR TOTAL OF ONE HOUR. APUSDR UALA2011101705597Girt Bar · dirty4R DOOR DISARMED, BUT SLIDE LIGHT REMAINED ON. CLEANED GIRT BAR AREA AND DEBRIS FROM SWITCHES. ARMED AND DISARMED DOOR SEVERAL TIMES AND SLIDE LIGHT WORKS NORMAL.SDR UALA2011101705623Circuit Breaker · faultedFUEL CROSSFEED LIGHT REMAINED ON WHEN OPEN-CLOSE SELECTED. RESET BREAKER AND RECONNECTED CONNECTOR TO AFT FUEL CROSSFEED ACTUATOR, AFT FUEL CROSSFEED CHECKED OKAY PER MM.SDR UALA2011101705586Skin · nickedBELLY HAS SMALL NICKS OVER THAT ENTIRE AREA OF SKIN. REPAIRED IAW EVA-81393.SDR UALA2011101405580Light · obstructedAFT LAVATORY EMERGENCY LIGHT COVERED BY CARPET. TRIMMED BACK CARPET, OPS CHECKED OK.SDR UALA2011101705616Battery Pack · inoperativeEMERGENCY EXIT SIGN INOPERATIVE. REPLACED BATTERY PACKS IAW MM, OPS CHECKED NORMAL.SDR UALA2011101705607Floorbeam · crackedFWD CARGO BAY, BS 700 FLOORBEAM UPPER TEE CRACKED LBL 24 INCHES. REPAIRED IAW EVA 81356.SDR UALA2011101305561Rib · missingSPLICE ASSY AT UPPER END OF VERTICAL STABILIZER LEADING EDGE PANEL 321BL MISSING INTERNAL RIB.SDR UALA2011101305559Compressor Blade · bentINGESTED RED TAIL HAWK IN RT ENGINE. DURING INSPECTION BIRD STRIKE OF RT ENG FOUND ONE FAN BLADE TIP BENT OUT OF LIMITS. REMOVED DAMAGED BLADE AND 2 OTHERS TO FACILITATE REPAIR TO ACOUSTIC LINING BEHIND FAN BLADES. REPLACED DAMAGED BLADE AND OPPOSITE AND RESDR UALA2011101305558Unknown · faultyLEFT EMERGENCY ESCAPE NO TEST TEST2. PER MEL OVERWING EMERGENCY ESCAPE BOTLLES WERE VISUALLY VERIFIED TO BE PROPERLY CHARGED IAW AMM. RDF-T :TRIED M32 TEST PANEL FROM ANOTHER A-C NO HELP, TRIED RELAY K10486 (WDM 25-65-11) NO HELP, FOUND HIGH RES. ON WIRE W35SDR UALA2011101305557Circuit Breaker · malfunctionedAPU FLAMED OUT WHEN PACKS TURNED OFF FOR ENGINE START. RERACKED CIRCUIT BREAKER. RAN NR 1 ENGINE WITH APU, NO FAULTS WITH APU. OKAY.SDR UALA2011101205552Ecu · unknownAPU NO START. NO MESSAGES FOUND ON BOX. STARTED FIRST TIME AND SEVERAL MORE TIMES, COULD NO DUPLICATE ON GROUND. FOUND NO FAULTS ON ECU & FIRST ATTEMPT FAILED, REPLACED ECU PER MM.SDR UALA2011101105516Pan · gougedEXTERNAL DOOR HANDLE PAN ASSY IS GOUGED BEYOND LIMITS AT THE R4 DOOR. REMOVED & REPLACED HANDLE PAN ASSY PER SRM AND REINSTALLED HANDLE BOX PER SM-50-52-11-06-JD.SDR UALA2011101105515Collar · wornL1 DOOR HOLD-OPEN LOCK WORN. REMOVED & REPLACED L1 DOOR HOLD OPEN LOCK COLLAR PER MM.SDR UALA2011101105514Link · wornL1 DOOR UPPER HINGE LINK WORN. REMOVED & REPLACED L1 DOOR UPPER HINGE LINK PER MM.SDR UALA2011101105513Bearing · seizedL2 DOOR EMERGENCY POWER ASSIST QUADRANT BEARINGS SEIZED. REMOVED QUADRANT & QUADRANT BEARING, CLEANED, REINSTALLED & LUBED BEARING. REINSTALLED QUADRANT PER MM AND GNMM 4-0-3-010 AND FOUND THE ACTUATION LEVER AND CAM ASSEMBLY TURNED FREELY PER MM.SDR UALA2011101105525Gcu · faultyL GEN DRIVE LIGHT IS NOT ILLUMINATED WHEN IT SHOULD BE LIGHT TESTS OKAY. COMPLIED WITH MEL 2411E. REPLACED LEFT GEN CNTRL UNIT, OPS NORMAL.SDR UALA2011101105517Circuit Card · defectiveEICAS MSG - L ENG FIRE LP 2. CREW COMMENTS: INTERMITTENT STATUS MSG. PROG TEXT: ACCOMPLISH CHRONIC REVIEW. NO TIME TO T/S. REPLACED FIRE DETECTION CARD M682, SYS GRND CHECKS GOOD.SDR UALA2011101105499Control Unit · malfunctionedNO AFT GALLEY POWER. REPLACED ELCU M227 PER MM, OPS CHECKS NORMAL.SDR UALA2011101005482Actuator · failedAT GATE, APU FAILED WITH FAULT LIGHT. TRIED RESTART 3 TIMES, FAILED ALL 3 TIMES. REMOVED AND REPLACED APU INTAKE DOOR ACTUATOR IAW AMM. OPS CHECKED NORMAL.SDR UALA2011101005445Cap · brokenARM CAPS BROKEN AT SEATS 16C, 17C, 18C. REPLACED ARM CAPS.SDR UALA2011101005459Shoulder Belt · frayedCAPTAIN'S RT SHOULDER HARNESS BEGINNING TO FRAY. REPLACED CAPTAIN'S SEAT INERTIA REEL.SDR UALA2011101005489Squib · missingSQUIB LT ASSY MISSING FOR L EMER ESCAPE SLIDE. REPLACED CAP ASSY FOR LEFT EMERGENCY ESCAPE SLIDE, TESTS OK.SDR UALA2011101005485Tape · missingBOARDING MUSIC BOX HOT AND NOISY. PROG TEXT: - ITEM ROLLED FORWARD. PULLED AND COLLARED 3 AMP. TAPE RPDRS. C-B IN P-37 PANEL PER WD. REPLACED MISSING AUDIO CASSETTE, OPS CHECK OKAY.SDR UALA2011101005469Life Vest · missingOBSERVER LIFE VEST IS MISSING. SEAT TO BE RENDERED INOP UNTIL LIFE VEST REPLACED. DEFERRED PER SAMC. REPLACED OBSERVER LIFE VEST.SDR UALA2011101005458Cap · missingEMERGENCY ESCAPE FLOOR LIGHT STRIP END CAPS MISSING 6B, 8C,1B AND 1L CLOSET AREA. REPLACED 3 END CAPS. CHECKS OKAY.SDR UALA2011101005448Unknown · odorSTRONG ELECTRICAL SMELL AROUND ROW 12 ON APPROACH. ACP'D OPENED UP CEILING PANELS, PCU PANELS, FROM ROWS 10 THRU 20. NO EVIDENCE OF ANYTHING RAN BOTH ENGS, CYCLED PACKS AND RECIRC FANS. NO EVIDENCE OF ELECTRICAL ODOR. ACFT POWERED UP FOR SEVERAL HOURS, NO SDR UALA2011101105500Door · corrodedMID LAV SERVICE PANEL DOOR HAS 1.5 INCH CORROSION BLISTER ON BOTTOM EDGE. DOOR IS INTACT AND CLOSED PROPERLY AND LATCHED. PANEL HAS EXTENSIVE CORROSION. REPLACED DOOR ASSY AND INSTALLED 143N3417-2 BRACKET AND PLACARDS.SDR UALA2011101005470Skin · puncturedFUSELAGE PUNCTURED, APPROX 12 INCH TEAR APPROX STATION 620 AT STRINGER 14, 15. LEFT SIDE AIRCRAFT FORWARD OF DOOR 2L.SDR UALA2011101005442Fmc · malfunctionedFMC SPONTANEOUSLY DUMPED ROUTE AND ALTITUDE DATA WHEN A DESCENT ALTITUDE WAS ENTERED. TALKED WITH CREW AND TOMC UNABLE TO DUPLICATE BY CREW. ALL DATA ENTERED AGAIN NO MESSAGE OR STATUS. NO PAST HISTORY. CYCLED CBS AND FMC IS NORMAL.SDR UALA2011101005440Floor Support · corrodedSTA 1662 FLOOR SUPPORT ABOVE WATER TANK IS CORRODED BETWEEN FLOORBEAMS. REMOVED AFT GALLEY FLOOR MAT FOR ACCESS, BAGGED AND STOWED IN LOB.
Back to Boeing 757-222