Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011042502003Oxygen Mask · leakingCAPTAIN'S O2 MASK HEADBAND HAS A LEAK. DATA REPLACED CAPTAIN'S MASK PER MM, OPS CHECKED & LEAK CHECKED GOOD.SDR UALA2011042502002Bottle · low pressureFOUND 1 RT DOOR SLIDE BOTTLE PRESSURE IN RED. REPLACED IR DOOR SLIDE PER MM OPS CHECK NORMAL. 1R MED SLIDE PERFORMED RII INSPECTION OF SLIDE INSTALLATION ASSY. NO DEFECTS FOUND.SDR UALA2011042501985Sliding Window · scratchedF/O SLIDING WINDOW IS HEAVILY SCRATCHED IMPAIRING VISION. REPLACED F/O OPENABLE WINDOW PER MM.SDR UALA2011042501973Structure · dirtyCANNOT ARM DOOR 2R. CLEANED LOWER DOOR AREA DISARM AND ARM DOOR, OPS CHECKED NORMAL.SDR UALA2011042501998Channel · corrodedHAT CHANNEL ON AFT CABIN PRESSURE DECK CORRODED BETWEEN STA 1688 - 1706 ON RT FLANGE. MAJOR REPAIR ACCOMPLISHED: INSTALLED 4 FREEZE PLUGS IN DISCREPANT LOCATIONS PER PEMCO PWI 809UA178, FABBED AND INSTALLED HAT CHANNEL PER SRM.SDR UALA2011042501995Intercostal · corrodedCORROSION ON MAIN CABIN FLOOR INTERCOSTAL AT STA 1650. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED INTERCOSTAL PER SRM.SDR UALA2011042502014Feeder Cable · defectiveEEL LIGHTING INOP, INTERMITTENT BETWEEN MID LAV AND OVERWING EXIT. REPLACED EEL LIGHT FEEDER CABLE AT OVERWING AREA. OPS TESTED NORMAL.SDR UALA2011042501997Tee Fitting · corrodedCORROSION ON T-FITTING STA 1720, RBL 53 IN THE MAIN CABIN. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED T-FITTING PER SRM.SDR UALA2011042501996Gusset · corrodedCORROSION AT ATTACH GUSSET STA 1681, RBL 33, MAIN CABIN. REMOVED AND REPLACED GUSSET PER SRM.SDR UALA2011042501993Light · inoperativeFLOOR EMERGENCY LIGHTS INOP, ALL FIRST CLASS. REPLACED SHORTED EMERGENCY LIGHT AT MID CABIN FLOOR, OPS CHECKED OKAY.SDR UALA2011042201959Circuit Card · faultyFWD CARGO DET 2 STATUS MSG AFTER FIRE TEST. NO TIME TO T/S. REPLACED CIRCUIT CARD M10427 PER MM. OPS NORMAL.SDR UALA2011042201958Circuit Board · faultyAFT 1 FWD 2 CARGO DET EICAS REMAIN ON AFTER FIRE TEST. NO TIME. AFT CARGO DET 1 WILL BE DEFERRED ON THIS ITEM. SEPARATE WRITE-UP WILL BE MADE FOR FWD CARGO DET 2. REPLACED CIRCUIT BOARD M10 427PER MM.SDR UALA2011042201955Light · inoperativeEMERGENCY FLOOR PATH LIGHTING HAS SECTION INOP JUST AFT OF ROW 6 TO MID LAV APPROX 27 INCHES INOP. JUST AFT OF ROW 6 TO MID LAV APPROX 27 INCHES INOP. REPLACED EEL LIGHT ASSY, OPS CHK NORMAL.SDR UALA2011042502008Wire Harness · disconnectedAT 16ABC EMERGENCY EXIT LIGHTS DETACHED. FOUND LOOSE CONNECTION IN EMERGENCY LIGHT WIRE HARNESS, RECONNECTED AND ALL OPS CHECKED NORMAL.SDR UALA2011042201962Plate · misalignedMAIN CABIN, DOOR R1 DOOR EMERGENCY POWER BOTTLE SERRATED PLATE NOT ALIGNED WITH CABLE TERMINAL SERRATIONS. ALIGNED MAIN CABIN DOOR R-1 EMERGENCY POWER BOTTLE SERRATED PLATE WITH CABLE TERMINAL SERRATIONS PER MM ON NON ROUTINE.SDR UALA2011042201961Spacer · missingMAIN CABIN, DOOR 2R DOOR EMERGENCY POWER BOTTLE LINKS ATTACH BOLT TO SPRING CYLINDER SHANKED OUT. *SUPPLEMENTAL DATA UPDATE* GAP BETWEEN LINK AND SPRING CYLINDER. INSTALLED SPACER BETWEEN LOWER LINKAGE AND SPRING CYLINDER AT MAIN CABIN R-2 DOOR EMERGENCY PSDR UALA2011042201960Spacer · missingMAIN CABIN, DOOR 4R DOOR EMERGENCY POWER BOTTLE LINKS HAVE INSUFFICIENT CLEARANCE WITH TRIGGER LEVER ATTACH RIVET, SPACERS MISSING. INSTALLED SPACERS AT UPPER AND LOWER LINKS ON MAIN CABIN, R-4 DOOR EMERGENCY POWER BOTTLE RESERVOIR PER MM ON NON ROUTINE.SDR UALA2011042201964Filter · faultyFLT DECK NOISE. DUE TO CHRONIC FLT DECK NOISE ISSUES WITH REPORTS OF BLOCKAGE IN THE CABIN OVERHEAD DISTRIBUTION DUCTS AND THE CABIN SIDEWALL OUTLETS NEED TO ACP THE FOLLOWING: CLEAN THE CABIN OVERHEAD DUCTS. CLEAN THE CABIN SIDEWALL OUTLETS, VALIDATE SIDEWALSDR UALA2011042201956Light · inoperativeEEL LIGHT INOP AT SEATS 14C, 10C AND MID LAV. REPLACED TWO EEL LIGHTS P/N 36262-4, AND ONE STRIP P/N 6025-2. OPS CHECK OKAY.SDR UALA2011042101948Reservoir · low pressureDOOR 1R SLIDE PRESS GAUGE NOT IN GREEN BAND. REPLACED EMERGENCY POWER RESERVOIR PER MM. PRESSURE IS OKAY.SDR UALA2011042101928Valve · out of toleranceINTERMITTENT THUMPING NOISE IN COCKPIT WHEN EITHER LEFT OR RIGHT PACK TURNED ON OR OFF. RECIRC OFF DOESN'T HELP. LEFT A-C PACK FLOW CONTROL VALVE, UPPER SUPPORT ROD ASSY FOUND TO BE WORN OUT. SUSPECT CAUSE OF HUMMING SOUND WHEN PACK IS TURNED ON. REPLACED SDR UALA2011042201951Floorbeam · corrodedCORROSION AT STA 1640 ON MAIN CABIN FLOORBEAM FROM RBL 54 - RBL 45. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION, FABRICATED AND INSTALLED T-CHORD AND 2 ANGLES PER SRM.SDR UALA2011042101946Light · faultyBEFORE CABIN CREW MOD STARTED, FOUND EMERGENCY LIGHT STRIP IN FRONT OF THE MID LAV AT STATION 740 IS NOT WORKING. REPAIRED EMERGENCY LIGHT STRIP.SDR UALA2011042001920Structure · damagedRT FWD NLG DOOR HAS 3 EA HOLES FROM LIGHTNING. REMOVED RT AFT NOSE GEAR DOOR FOR ACCESS TO LIGHTNING STRIKE DAMAGE. ACCOMPLISHED REPAIR PER SRM AND GNMM.SDR UALA2011042201957Control Valve · faultyFLT DECK NOISE EXCESSIVE. ACP'D CALLOUT. REPLACED RT FLOW CONTROL VLV PER MM. OPERATIONAL AND LEAK CHECK GOOD. FLIGHT DECK NOISE LEVELS DECREASED SIGNIFICANTLY.SDR UALA2011042001919Skin · dentedEXT FUSE SKIN IS DENTED AND BULGED AT FRAME STA 600, AND 640 STR 17L AND 18L. OK TO ARC REF SRM 53-00-01 FIG 101 DETAIL III AND SRM 51-70-01, HFEC NO CRACKS. REPLACED SHEAR TIE ON WU"S D4028X, D4030X.SDR UALA2011042001916Slide · unserviceableNR 4 RT MED SLIDE COVER AFT UPPER PIN LACING IS BROKEN. REPLACED 4R MED SLIDE PER MM.SDR UALA2011042001915Control Valve · defectiveCOCKPIT AIR NOISE EXCESSIVE. DUCT CLEAN UP IS DONE, PREP TO ACP ENG RUN TO CHECK DUCT PRESS AND DECIBLE READINGS. COMPLETED NOISE CHECK WITH METER WITH ENGINE RUNNING. DUCT PRESSURE WAS AT 12 PSI. 76 DECIBELS WITH RIGHT RECIRCULATION FAN OFF, 79 DECIBELS WISDR UALA2011042101927Fan · faultyUNCOMFORTABLE, AFFECT PILOTS-ATC COMMUNICATIONS TURNING R RECIRC FAN OFF PROVEN LITTLE HELP. RECIRC FAN IS OLD STYLE WITHOUT BAFFLE. PER SERVICE TIP OK TO DEFER FOR FAN REPLACEMENT. NEED FAN PCN 564-0211. REPLACED RIGHT RECIRC FAN, OPS CHECK GOOD.SDR UALA2011042101938Cable · defectiveBEFORE CABIN CREW PERFORMED CABIN MOD CHECK, FOUND EEL LIGHT STRIP NOT WORKING IN FRONT OF THE FWD AFT LAVATORY DOOR. DEFERRED PER MEL. NEED LIGHTING CABLE ASSY. (560-0812). NO PARTS SMF. REPAIRED EEL LIGHTS IN FRONT OF FWD AFT LAV. OPS CHKS GOOD.SDR UALA2011042101939Socket · dirtyALL 3 GEAR UNSAFE LIGHTS ARE INOP FROM RESPECTIVE TEST SWITCHES. REPLACED NOSE AND RT WW LAMPS, OPS GOOD. LT SOCKET WAS FULL OF CORROSION, CLEANED OUT SOCKET AS MUCH AS POSSIBLE AND CLEANED. WITH CONTACT CLEANED AND REPLACED LAMP, NO HELP. NEED TO REPLACE SDR UALA2011042101942Light · disconnectedFOUND EEL LIGHT STRIP NOT WORKING IN FRONT OF THE FWD AFT LAV DOOR. REPLUG EEL LIGHT TO STRIP. OPS CHECK LIGHTING EEL LIGHT WORKS FINE.SDR UALA2011042101937Heat Shield · damagedHEAT SHIELD HAS DAMAGE. REPLACED HEAT SHIELD PER MM.SDR UALA2011042101921Floorbeam · corrodedAFT CABIN FLOORBEAM CORRODED AT STA 1660, RBL 3 TO RBL 5. REPLACED FLOORBEAMS FROM RBL 3 TO RBL 24 PER SRM. ACP ON PEMCO NR 2537N00118, BY MECH AND INSPECTOR.SDR UALA2011042001918Structure · crackedFLOORBEAM STA 700 CRACKED AT LBL 45. RPRD PER SRM 53-00-51, RPR. 3 AND UA EVA 80770, ON SMB W-U F6397E.SDR UALA2011042001917Mechanism · dirtyCANNOT ARM DOOR 3R. CLEANED AND LUBED SLIDE ARM MECHANISM AT AFT RT DOOR.SDR UALA2011041901897Axle · chippedRT NOSE TIRE OUTER AXLE BEARING SURFACE IS CHIPPED 1-16 WIDE BY 3-8 LONG. REPLACED NLG AXLE. REPLACED NR 1 AFT BRAKE ASSY. FOUND RT NOSE TIRE WITH BROKEN TREAD CORD. REPLACED NR 1 AFT MLG TIRE. REPLACED BOTH NOSE TIRES PER MM.SDR UALA2011042001911Oxygen Mask · inoperativeCREW REPORT: CAPTS OXYGEN MASK HAS NO OXYGEN FLOW. SWAPPED WITH OBSERVERS MASK. OBVS SEAT INOP. RPLCD OBVS. MASK AND OP CHECK ON SMB W-U X0407H.SDR UALA2011042101936Pump · failedL ENG HYD PUMP OVHT, FLIGHT DIVERTED. REPLACED THE LEFT ENGINE DRIVEN HYD PUMP DUE TO PUMP FAILURE. PUMP FAILURE ALSO CAUSE OF FLUID LEAK.SDR UALA2011042101929Oxygen Mask · damagedF/O O2 MASK COMM CHORD WIRES EXPOSED. REPLACED MASK.SDR UALA2011042001903Window · defectiveHIGH PITCH SQUEAL WINDOW 1L STARTED ABOUT 20 MINUTES AFTER LEVEL AT CRUISE. WINDOW FOUND DEFECTIVE. REPLACED WINDOW.SDR UALA2011041801847Cover · damagedFOUND EEL TRACK COVER BROKEN LAST 4-5 ROW SEATING. ACP INTERIM REPAIR WITH TAPE 912-0889 TO SECURE EEL TRACK. EEL LIGHT OPERATION IS NOT OBSTRUCTED. WILL NEED 1EA 560-0801 EEL TRACK (ISSUE AS 24FT) REPLACED AT NEXT MAINT OPPORTUNITIY. WILL NEED 560-0801 EESDR UALA2011042001902Charger · faultyMAIN BATTERY CHARGER STATUS MSG. INOP APU SWAP APU BATTERY CHARGER WITH MAIN BATTERY CHARGER. MR24321 OFF 61 ON 312. REPLACED MAIN BATTERY CHARGER. OP CHECKS GOOD, MESSAGE CLEARED.SDR UALA2011041901901Panel · damagedUPPER INBOARD WING LEADING EDGE BULLNOSE HAS DAMAGE. IN REFERENCE TO SMC002, NEED TO REMOVE THE LT WING FIXED L/E PANEL UNDER NR 6 SLAT THAT HAS 7 CRACKS AND A COUPLE OF DELAM AREAS AND REMOVED AND REPLACED TO SHOP. 90% OF FASTENERS ARE REMOVED, NEED TO CONTISDR UALA2011041801878Unknown · malfunctionedAUTOPILOT DISCREPANCY, RTFL.SDR UALA2011041801875Switch · shortedFWD AFT LAV DOOR SWITCH SHORTED CAUSING SMOKE IN AFT CABIN PRIOR TO DEPARTURE. REPLACED LAV DOOR SWITCH ASSY WIRES WERE NOT DAMAGED. ONLY THE MICRO SWITCH WAS DAMAGED. OPS TESTED AFTER RE-ASSEMBLY WITH NEW SWITCH. CHECKED GOOD AFTER MULTIPLE CYCLES (SWITCHSDR UALA2011041801891Valve · faultyWITH APU BLEED SW ON, ONLY SHOWING 10 PSI. APU BLEED VALVE MANUALLY CLOSED, BREAKERS Q22 & P11 OPEN. CHECKED OPERATION OF BLEED VLV PER MM. OPERATION GOOD NEVER HUNG UP RE-INSTALLED CONN D3576. HOOKED TESTER UP FOUND SV TM VOLT OUT OF TOL. REPLACED SURGE VSDR UALA2011041801855Bearing · faultyLT INBD MAIN FLAP TRACK FWD ATTACH POINT BEARING PUSHED OUT OF TRACK WITH INBOARD LOAD FROM FLAP HOLDING TRACK AGAINST MOUNTING BRACKET. BEARING IS CAPTURED BY SUPPORT BRACKETS AND CANNOT MOVE FURTHER. REMOVED FITTING REPLACED. REPLACED BEARING PER GNMM. LSDR UALA2011041801868Feeder Cable · defectiveCABIN FLOOR EEL LIGHTS INOP BTWN SEAT ROW 17 AND SEAT ROW 27. REPLACED FLOOR EEL LIGHTS POWER FEEDER. EEL LIGHTS OP CHECK OKAY.SDR UALA2011041801859Probe · inoperativeTAT PROBE INOP, FLIGHT DIVERTED. REPLACED TAT PROBE, OPS CHECKED NORMAL.
Back to Boeing 757-222