Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009072702236Shutoff Valve · faultyRT PACK RIGHT DUCT PRESS 5 PSI LEFT 16 PSI. REPLACED HIGH STAGE PILOT AND HIGH PRESSURE SHUTOFF VALVE. OPS CHECKED NORMAL WITH ENG RUN.SDR UALA2009072402204Lamp · inoperativeDOOR 2L EMERGENCY LIGHT INOPERATIVE. RELAMPED AND OPS CHECKS GOOD.SDR UALA2009072402203Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK M732 INOP. INSTALLED NEW M732 BATTERY PACK AND OPS CHECKS GOOD.SDR UALA2009072302198Idg · faultyLEFT GENERATOR DRIVE LIGHT IS INOP. REPLACED NR 1 IDG, OPS CHECK OKAY.SDR UALA2009072302176Light · inoperativeSEAT MOUNTED EMERGENCY LIGHT INOP AT SEAT ROW 18ABC. REPLACED LIGHT ASSY, OP CHECK OKAY.SDR UALA2009072202165Panel · corrodedAFT CARGO PIT FLOOR PANEL DAMAGED AND CORROSION ON UNDERLYING STRUCTURE. MAJOR REPAIR ACCOMPLISHED. FLOOR PANEL REMOVAL. CORROSION WAS NOTED AT THE SILL PLATE HAT CHANNEL EXTENDING THE WIDTH OF THE CARGO PIT ENTRY WAY. REMOVED AFT PIT UPPER SCUFF PLATE. OSDR UALA2009072302199Bleed Valve · faultyLEFT BLEED AIR PRESS FLUCTUATING FROM 20 TO 40 PSI DURING DESCENT. TROUBLESHOT PER MM. UNABLE TO DETECT ANY FAILURE MODES. REPLACED PRSOV AS A PRECAUTION.SDR UALA2009072002148Shutoff Valve · failedLEFT ENG BLEED ANNUNCIATOR CYCLED ON OFF THREE TIMES. REPLACED PRSOV AND PRSOV REGULATOR. OP CHECK OKAY.SDR UALA2009072002128Light · inoperativeDOOR 2L EXTERIOR EVACUATION LIGHT INOP. RELAMPED EXTERIOR EVACUATION LIGHT.SDR UALA2009072002119Retainer · dirtyUNABLE TO DISARM R AFT DOOR. CLEANED DEBRIS OUT OF DOOR SLIDE RETAINER AND LUBED, DOOR ARM, DISARM OPS CHECKED NORMAL.SDR UALA2009072002137Oven · odorELEC ODOR COMING FROM EQUIP DOOR ABOVE MID GALLEY. DOOR WAS OPENED, NO ASSOCIATED SMOKE. ACCMP'D CHECK OF WIRING BEHIND GALLEY G2 OVERHEAD LIGHT. NO NOTED BURNS OR SMOKE DAMAGE. ALL GALLEY FUNCTIONS OPERATE NORMAL. ALL CIRCUIT BREAKERS STILL CLOSED.SDR UALA2009071702113Wire · burnedFOUND 8 BURNT WIRES IN BUNDLE ABOVE E4-1, MARKED WIRE BUNDLE WITH TAPE, BURNT WIRE ARE ABOUT 2 INCHES INBOARD OF TAPE. THE SUSPECT ROOT CAUSE FOR THE WIRE DAMAGE WAS THAT THE WIRES BUNDLES WERE NOT TIED DOWN. SECURED PROPERLY. AS SUCH THE TWO WIRE BUNDLES SDR UALA2009071702108Slide · tornRT OVERWING SLIDE INSIDE PACK IS TORN, PACK COMING LOOSE. REPLACE SLIDE ON WU R7806N.SDR UALA2009071502085Light · inoperativeEEL STRIP ON SEAT 15C IS NOT WORKING. REPLACED EEL STRIP AT SEAT 15C. CHECKS GOOD.SDR UALA2009071502084Connector · brokenEEL STRIP ON SEAT 26C IS NOT WORKING. REPLACED BROKEN CONNECTOR UNDER SEAT 26B. CHECKS GOOD.SDR UALA2009071502083Light · inoperativeLEFT DOOR NR 1 EXTERIOR EMERGENCY LIGHT INOPERATIVE. RELAMPED EMERGENCY LIGHT.SDR UALA2009071502093Ring · out of positionTHE 'D' RING AT DOOR 2L ON WRONG SIDE OF DOOR. SECURED 'D' RING ON CORRECT LOCATION.SDR UALA2009071402082Start Valve · faultyLT STARTER CUTOUT EICAS AND START VALVE LIGHT ON. REPLACED NR 1 ENGINE START VALVE. CHECKED AND SHOOK WIRING TO START VALVE. NO FAULTS FOUND. RAN ENGINE, ALL NORMAL. OPS CHECKED GOOD.SDR UALA2009071302059Indicator · obstructedRIGHT FUEL QUANTITY INDICATOR HAS AIR BUBBLES THAT OBSCURE THE MAIN TANK AND TOTALIZER VALUE. REPLACED FUEL QUANTITY INDICATOR, INDICATION TEST GOOD NO MESSAGES NOTED.SDR UALA2009071302061Oxygen Mask · inoperativeCAPTAIN'S O2 MASK MIKE IS NOT WORKING. REPLACED CAPTS AUDIO SELECT PANEL. SYSTEM CHECKS NORMAL AT THE GATE. ALSO CHANGED CAPTAIN'S O2 MASK ASSY. SYSTEM CHECKS NORMAL AT THE GATE.SDR UALA2009071302044Heat Exchanger · leakingFUEL OIL HEAT EXCHANGER LEAKING. AFTER REPLACEMENT OF NR 2 FUEL OIL HEAT EXCHANGER RAN NR 2 ENG LEAKING 24 DROPS A MIN. BAD FROM STOCK. REPLACED FUEL OIL HEAT EXCHANGER. LEAK CHECKS GOOD.SDR UALA2009071302043Idg · leakingRIGHT GEN 'FIELD OFF' LIGHT ILLUM WITH FIELD OFF SW PRESSED. REPLACED NR 2 ENG IDG, OPS CHECKED ALL INDICATIONS NORMAL, NO LEAKS NOTED.SDR UALA2009071302058Shutoff Valve · stuckEICAS MSG 'APU BLEED VAL' DISPLAYED. APU BLEED AIR VALVE LIGHT ON. DUCT PRESSURE WAS ZERO. APU BLEED AIR VALVE LOCKED IN THE CLOSED POSITION. REPLACED APU SHUT-OFF VALVE. OPS CHECKED VALVE BY CYCLE OPEN AND CLOSE A COUPLE OF TIMES AND DRY MOTOR AN ENGINE.SDR UALA2009071302034Connector · not seatedEEL FLOOR LIGHT AT SEAT ROWS 9 THROUGH 12 INOP. RESEATED CONNECTION AT FEEDER FOR EEL FLOOR LIGHTS, ROW 9-12. OPS CHECK GOOD.SDR UALA2009071302033Light · faultyEEL LIGHT AT 'S' LAV PARTIALLY LIT. REPLACED 'S' LAV LIGHT AND OPS CHECK GOOD.SDR UALA2009071302023Pin · damagedFIRE EXTINGUISHER IN LAST ROW OF FIRST CLASS HAS A DAMAGED PIN. REPLACED EXTINGUISHER.SDR UALA2009071002015Contact · dirtyEXTERIOR EMERGENCY LIGHT OUT FOR DOOR 4R. CLEANED CONTACT, CHECK OKAY.SDR UALA2009070801968Feeder Cable · inoperativeEMERGENCY LIGHT INOP ON SEAT 19A. REPLACED SEAT CABLE. CHECKS GOOD.SDR UALA2009070801967Contact · dirtyEXTERIOR EMERGENCY LIGHT OUT FOR DOOR 1R. CLEANED CONTACT. CHECKED OK.SDR UALA09070801966ALamp · inoperativeAFT CARGO DOOR EXTERIOR EMERGENCY ESCAPE PATH LIGHT INOP. REPLACED LAMP, OPS GOOD.SDR UALA2009070801972Engine · failedDIVERTED ON AMBER ALERT WITH NR 2 ENG SHUTDOWN. ACCOMPLISHED NR 2 ENGINE BORESCOPE INSP OF LPC, HPC, COMBUSTION CHAMBER INNER AND OUTER LINER, NGVS AND INJECTORS, HPT 1 AND 2 BLADES AND LPT 3 BLADES. NO LIMITING DISTRESS. ALL PLUGS INSTALLED. TROUBLESHOOT SDR UALA2009070901976Bearing · damagedDOOR 4R DIFFICULT TO DISARM. REMOVED DOOR 4R ESCAPE SLIDE TO ACCESS DOOR ARM-DISARM LEVER MECHANISM. FOUND BEARINGS MIGRATING AND RUSTED AT UPPER TORQUE SHAFT FROM ARMING HANDLE TO DOOR ASSIST MECHANISM. CLEANED AND LUBED BEARINGS, BEARINGS WERE NOT MIGRATESDR UALA2009070701957Oxygen Mask · faultyCAPTAIN'S OXYGEN MASK DEFECTIVE. CREW COMMENTS: ELASTIC ANCHOR BAND IS STRETCHED AND LOOSE. SWAPPED CAPTS AND OBSERVERS SEAT O2 MASK AND THEN INOP OBSERVERS SEAT. REPLACED OBS MASK ASSY.SDR UALA2009070701953Slide · unserviceableUNABLE TO ARM DOOR 2R. REPLACED SLIDE PACK FOR DOOR 2R.SDR UALA2009070601933Light · inoperativeDOOR 4R EXTERIOR SLIDE LIGHT INOPERATIVE. RELAMPED DOOR 4R EXTERIOR SLIDE LIGHT.SDR UALA2009070601928Eec · faultySTATUS MSG R ENG SEC CONT. ON EPCS PAGE HAD SFCU-ECC AND 350-20 MESSAGE. RANG OUT WIRES FROM EEC SECONDARY TO FCU SECONDARY, NO FAULTS FOUND. RANG OUT FCU PER EPCS MESSAGE INDEX FIGURE 115 PG 8. ALL VALUES CHECKED GOOD EXCEPT PINS 14-15. SHOWED OPEN ON BOSDR UALA2009070701959Skin · delaminatedNR 2 ENGINE OUTBOARD RT REVERSER COWL UPPER BIFURCATION PANEL INNER SKIN IS DELAMINATED BETWEEN APPROX 290 TO 310 SQ IN. REPLACED NR 2 ENG O/B REV HALF.SDR UALA2009070701958Combust Chamber · crackedNR 2 ENGINE COMBUSTION CHAMBER INNER LINER AT APPROX 150 DEGREE HAS IN LINE AXIAL CRACKING THROUGH FOUR FULL LOUVERS AND 80 PERCENT OF FIFTH LOUVER WITH 2 LOUVERS HAVING SEPARATION GREATER THAN .060 AND SOME MISMATCH OUT OF LIMITS. REPLACED NR 2 ENGINE. ACP'SDR UALA2009070601915Flashlight · inoperativeDOOR 3L FLASHLIGHT INOP. REPLACED FLASHLIGHT ASSY.SDR UALA2009070201908Skin · delaminatedRIGHT INBOARD FLAP OUTBOARD AFT FAIRING IS DELAMINATED. FLAP REMOVED & SENT TO SHOP 273 FOR REPAIR. REPLACED RT TRAILING EDGE FLAP. CREW COMMENTS: GOOD TEST FLIGHT FOR FLAP REPLACEMENT.SDR UALA2009070101892Bottle · reads lowDOOR 1L SLIDE PSI LOW. EVACUATION SLIDE BOTTLE PRESS (LOW, ZERO) AT DOOR 1. REPLACED DOOR MOUNTED SLIDE RAFT REF MM 25-66-01.SDR UALA2009070101894Lamp · inoperativeTHE 2L MED EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED LAMP P/N 767 AND OPS GOOD.SDR UALA2009070101884Fuel Control · faultyAPU FAILED TO START. FAULT LIGHT ILLUM AND EICAS MSG. APU FAULT DISPLAYED. NO MSG ON BOX. ONE AUTO EVENT 35 PERCENT 770 DEG. HOOKED TESTER UP COULD NOT GET TO FAULT. DOOR CIRCUIT NEVER FAILED. CHECKED INLET FOR BLOCKAGE OKAY. NO SPIKE VOLT FROM CHARGERSDR UALA2009070101893Pushrod · out of adjustMAIN CABIN DOOR 4L SLIDE ARM-DISARM HANDLE STIFF. CHECKED DOOR, ADJUSTED PUSHROD-D. OPS CHECKS GOOD.SDR UALA2009070101890Lamp · inoperativeEMERGENCY EXIT FLOOD LIGHT MOUNTED ON STOW BIN ABOVE SEAT 7C IS INOP. RELAMPED EMERGENCY LIGHT, OPS CHECKS GOOD.SDR UALA2009070101888Light · inoperativeAFT FWD LAV JUST FWD OF DOOR EMERGENCY LIGHT INOP. REPLACED EMERGENCY LIGHT STRIP.SDR UALA2009070101887Light · inoperativeMID LAV JUST FWD OF DOOR EMERGENCY LIGHT INOP. REPLACED EMERGENCY LIGHT STRIP.SDR UALA2009070101885Actuator · failedAILERON TRIM INOPERATIVE. REPLACED AILERON RUDDER TRIM PANEL RUDDER TRIM SYSTEM, OP CHECK OK, AILERON SYSTEM NO HELP. NEED AILERON TRIM ACTUATOR. AILERON TRIM ACTUATOR, OPS CHECKS GOOD.SDR UALA2009063001878Light · brokenEMERGENCY LIGHTING ON FLOOR NEAR 9B IS BROKEN. RESECURED LIGHT ASSY AND OP CHECKED EMERGENCY LIGHTS.SDR UALA2009062901861Unknown · malfunctionedTWO F/A'S AND ONE PASSENGER REPORT WHAT FEELS LIKE AN "ELECTRICAL SHOCK" FROM CART WHILE USING IT AT ROW 28-29 LT OF ACFT. CARPET IN AREA WET WITH UNKNOWN MOISTURE. CRACKLING NOISE HEARD BY 2 F/A'S. FAN DRIED CARPET. CHECKED LAVS, GALLEYS & RAN CHILLERS.
Back to Boeing 757-222