Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009012000216Shutoff Valve · failedLEFT ENG BLEED VLV WILL NOT COMPLETELY CLOSE WHEN SW IS PLACED IN THE OFF POSITION. HISTORY. REPLACED PRSOV VALVE. LEAK CHECKED. RAN 5 MINUTES AND BLEED OPEN AND CLOSED NORMAL.SDR UALA2009011900208Frame · crackedCRACKS ON FRAMES BS 680 AT STR 12 AND STR 11 RT. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED P/N 143N8334-28 FRAME INTERCOSTAL. PERFORMED GIRT BAR PROX SENSOR, OPS CHECK GOOD.SDR UALA2009011900207Frame · crackedCRACK ON FRAME AT BS 680 AND STRINGER 12L. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED P/N 143N8334-27 FRAME INTERCOSTAL. ACCOMPLISHED GIRT BAR PROX SWITCH, OPS CHECKED GOOD.SDR UALA2009011900206Light · disconnectedEMERGENCY LIGHTS BAR CAME UNGLUED FROM FLOOR AT 2L. LOCATION IS NEXT TO FIRST CLASS CLOSET. SECURED WITH TAPE. SECURED EMERGENCY LIGHT NEXT TO FIRST CLASS CLOSET.SDR UALA2009011900204Pin · brokenEEL ESCAPE LIGHTING ON FLOOR AT FWD AFT LAV IS INOP. LIGHT STRIP CONNECTOR PINS BROKEN. REPLACED EEL FLOOR LIGHTING STRIP AT AFT FWD LAV P/N 6024-3, OPS CHECKED GOOD.SDR UALA2009011900199Fitting · corrodedRT MLG WHEEL WELL AFT INBOARD BULKHEAD AREA KEEL BEAM BATHTUB FITTING IS CORRODED STA 1180, RBL 2. FABRICATED & INSTALLED NEW FITTING.SDR UALA2009011900198Cable · out of adjustR-1 DOOR EMERGENCY POWER ACTUATION CABLE FAILED PULL CHECK. ADJUSTED CABLE TRIGGER, ONE TURN COUNTER CLOCK WISE, INSTALLED SPRING CLIP LOCK. OPS CHECKS GOOD.SDR UALA2009011900196Connector · defectiveSEVERAL EMERGENCY EXIT LIGHTS ARE INOP. REPLACED AFT EEL FLOOR LIGHTING PLUG IN STRIP. CLEANED SOCKETS BULLNOSE LIGHTS. CHECKS OK.SDR UALA2009011900192Pressure Switch · failedNR 2 ENGINE FUEL FILTER BYPASS MESSAGE ON EICAS. DIVERTING TO SLC. ACP WIRING CHECK, AND REPLACED NR 2 FUEL DIFFERENTIAL PRESSURE SWITCH. ACCMP'D DRY MOTOR AND CHECKED FOR LEAKS. ACCMP MOTOR AND LEAK CHECK. NO LEAKS NOTED.SDR UALA2009031000183Light · unsecureEMERGENCY LIGHT COVER STRIP IN FRONT OF CLOSET 340 IS DETACHED FROM FLOOR. SECURED EMERGENCY LIGHT STRIP LENS.SDR UALA2009031000173Lamp · inoperativeDOOR 1R EMERGENCY EXTERIOR LIGHT INOP. RELAMPED, CHECKS GOOD.SDR UALA2009031000172Lamp · unsecureDOOR 1L EMERGENCY EXTERIOR LIGHT INOP. SECURED LAMP. CKS GOOD.SDR UALA2009011500165Frame · dentedAFT PIT FRAME STA 1420, DENT IN FRAME LT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME & INSTALLED DOUBLER REPAIR.SDR UALA2009011500164Frame · dentedAFT PIT FRAME STA 1360, DENT IN FRAME, LT SIDE SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2009011500163Frame · dentedAFT PIT FRAME STA 1440, DENT IN FRAME LT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME & INSTALLED DOUBLER REPAIR.SDR UALA2009011500162Frame · dentedAFT PIT FRAME STA 1460, DENT IN FRAME LT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2009011400157Annunciator · failedLEFT ENG BOTTLE DISCHARGE ANNUNCIATOR ON P8 PNL FAILED TO ILLUMINATE DURING BOTTLE DISCHARGE TEST. INSTALLED NEW LT ENG BOTTLE DISCHARGE ANNUNCIATOR ON P8 PNL, OPS CHECKS GOOD.SDR UALA2009011400156Frame · dentedAFT PIT FRAME STA 1340, DENT IN FRAME RT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2009011300136Light · missingSEAT 16C EMERGENCY LIGHT MISSING. REPLACED EMERGENCY LIGHT STRIP. OPS CHECKED OK.SDR UALA2009011300135Light · brokenSEAT 10B EMERGENCY LIGHT BROKEN. NEW EMERGENCY LIGHT INSTALLED.SDR UALA2009011200124Unknown · smokeCREW REPORTS ELEC SMELL IN CABIN WHILE BEING DEICED ( NOT DEICING FLUID SMELL). CAPT REPORTS A HEAVY BLACK SMOKE MOST PRONOUNCED BETWEEN DOOR 2 AND THE FIRST OW HATCH. CKD AND OPERATED ALL INTERIOR CABIN ITEMS, REMOVED CEILING PANELS, CKD WIRING AND DUCTS. SDR UALA2009011300134Idg · faultyAFTER RT ENG SHUTDOWN, HAD COMPLETE ELEC FAILURE. LT BUS ISLN LIGHT ON+LT GEN DROPPED OFF. REPLACED NR1 ENGINE IDG. OPS CHECK OKAY.SDR UALA2009011200113Frame · dentedAFT PIT FRAME STA 1480, DENT IN FRAME LT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGE AND INSTALLED DOUBLER REPAIR BETWEEN STR 25 AND 27L.SDR UALA2009011200112Switch · stuckFLOOR EMERGENCY EXIT EEL LIGHTS FROM ROW 28 TO REAR OF ACFT, AFT MOST CTR LINE EMERGENCY EXIT SIGN AND EMERGENCY EXIT SIGN ABOVE AFT LT EXIT DOOR ARE ILLUMINATED ALL THE TIME. FOUND TEST SWITCH OVER LT AFT DOOR TO BE STUCK IN, REPAIRED, SYS CHECKS GOOD.SDR UALA2009011200111Battery · dischargedCOVE EMERGENCY LIGHTING INOP FROM ROW 27 RT SIDE TO REAR AND EMERGENCY EXIT SIGN ABOVE AFT RT EXIT DOOR. REPLACED BATTERY, SYS CHECKS GOOD.SDR UALA2009011200110Battery · dischargedFLOOR EEL LIGHTS INOP FROM ROW 23 TO REAR OF ACFT. REPLACED EEL BATTERY, SYS CHECKS GOOD.SDR UALA2009011200109Frame · dentedAFT PIT FRAME STA 1400, DENT IN LT SIDE FRAME IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2009011200108Skin · damagedAFT CARGO DOOR, LWR AFT CORNER HAS 3-8TH INCH CRACK, HAS STOP DRILL, BUT HOLE DOES NOT GO THROUGH ENTIRE THICKNESS OF SKIN. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGE AND INSTALLED DOUBLER REPAIR.SDR UALA2009011200131Slide · low pressurePRESSURE LOW. UNKNOWN. GAUGE READS WITHIN LIMITS. NO ACTION TAKEN.SDR UALA2009011200130Gauge · leakingSLIDE PRESSURE LOW. LEAKING AROUND GAUGE FACE. REMOVED AND REPLACED GAUGE.SDR UALA2009011200107Collar · brokenL2 MED BODY TORQUE TUBE LOCKING COLLAR BROKEN. INSTALLED NEW HOLD-OPEN COLLAR.SDR UALA200901090099Bpcu · failedJUST PRIOR TO REACHING CRUISE, BOTH UTILITY BUSSES TRIPPED. SINGLE RESET OF BOTH UTILITY BUSES NO HELP. UTILITY BUSSES RESET 4 TIMES, NO HELP. REPLACED BPCU. SYS OPS NORMAL, ALL BUSSES RESET AND FUNCTION NORMALLY.SDR UALA20090109001ALens · dislodgedEXIT SIGN OVER 2L CAME OFF AT THE GATE AND 1 CLEAR LENS POPPED OUT. REPLACED LIGHT LENS.SDR UALA2009010900098Flap · malfunctionedFLAPS FAILED TO MOVE. T/E LIGHT ILLUMIN EICAS MESSAGE 'T/E FLAP DISAGREE' DISPLAYED. FLAPS OPERATE NORMALLY ALTERNATE SYS. REPLACED NR 2 FSEU WITH DIGITAL MODEL. ALL ADJUSTMENTS CHECK GOOD. REPLACED NR 8 FLAP TRANSMISSION AND INSTALLED NEW JACKSCREW. OPS CSDR UALA2009010900090Start Valve · faultyLT START VALVE WON'T ENGAGE CIRCUIT BREAKER POPPED. RPL NR1 ENG START VALVE. MOTORED ENGINE, START CONTROL CB STAYED IN AND START VALVE OPS AND LEAK CHECKED GOOD.SDR UALA2009010900100Control Unit · faultyLT GEN DRIVE LIGHT INOP. REPLACED LT GCU AND REPLACE BPCU. RAN NR1 ENG, OPS CK GOOD .SDR UALA2009031000064Wire · disconnectedEMERG EXIT LT PWR STRIP DISCONNECTED AT 6B. POWER LEAD DAMAGED, REQUIRES REPLACEMENT. NO EXPOSED WIRING. REPLACED EMERGENCY LIGHT STRIPS.SDR UALA2009031000061O-Ring · leakingLOW BOTTLE. LEAKING AT BALL SHAFT O-RING. REMOVED AND REPLACED O-RING.SDR UALA2009010600064Feeder Cable · disconnectedEMERGENCY EXIT LIGHT POWER STRIP DISCONNECTED AT 6B. POWER LEAD DAMAGED, REQUIRES REPLACEMENT. NO EXPOSED WIRING. REPLACED EMERGENCY LIGHT STRIPS.SDR UALA2009010600061O-Ring · leakingLOW BOTTLE. LEAKING AT BALL SHAFT O-RING. REMOVED AND REPLACED O-RING.SDR UALA2009010600075Pressure Switch · malfunctionedFUEL FILTER BYPASS MSG. FLIGHT DIVERTED. REPLACED FUEL PUMP FILTER DIFFERENTIAL PRESSURE SWITCH, LEAK CK AND OPS OK. REPLACED FUEL FILTER BYPASS CONNECTOR D5004 AND ACCOMPLISHED ENG RUN. SYSTEM OPS CHECKS SATISFACTORY.SDR UALA2009010600072Coupling · brokenR BLEED DUCT LEAK. RTFL. FOUND BROKEN FUSED COUPLING ON DUCT IN WING LEADING EDGE JUST ABOVE PYLON. REPLACED COUPLING AND DUCT SEAL. LEAK CHECKED GOOD.SDR UALA2009010600067Actuator · faultyUPON GEAR EXTENSION, *GEAR DISAGREE* DISPLAYED, NO NOSE GREEN LIGHT, CYCLED GEAR TWICE, NO HELP, USED ALT GEAR EXTEND, GEAR INDICATION NORMAL. GEAR DOORS LIGHT AFTER ALT EXTENSION. R&R NLG LOCK ACT ASSY PER MM, CKS OK. BORROWED PART FROM AA, PN 273N1005-1, SNSDR UALA2009010500049Feeder Cable · faultyEMERGENCY PATH LIGHTS INOP BETWEEN SEATS 16 AND 22. REPLACED PWR FEEDER IN TRACK AND DRIED OUT WET TRACK. OPERATES NORMALLY.SDR UALA2009010500040Slide · out of positionSLIDE PACK FELL OUT DOOR 2L. REPLACED SLIDE ASSY.SDR UALA2009010500051Lanyard · out of positionDOOR 1R SLIDE WILL NOT ARM. SECURED LANYARD IN PROPER POSITION. ARMED DOOR SEVERAL TIMES, CKS GOOD.SDR UALA2009010200011Light · inoperativeDOOR NR 1 LT EMERGENCY EXIT LIGHT INOP (EXT). RELAMPED, CHECKS GOOD.SDR UALA2008123107063Light · inoperativeNR 3 RT MED EXTERIOR EMERGENCY LIGHT INOP. RELAMPED. OPS CHECKED OKSDR UALA2008123107062Light · inoperativeNR 1 RT FWD DOOR EXTERIOR EMERGENCY LIGHT INOP. RELAMPED, OPS CHECK OK.SDR UALA2008123107061Light · inoperativeRT FWD OVER WING SLIDE EMERGENCY EXIT LIGHT INOP. RELAMPED, OPS CK GOOD.
Back to Boeing 757-222