SDR CALA2017081102629Wire · looseEMERGENCY LIGHT SIGN INOPERATIVE ABOVE R1 DOOR. TROUBLESHOT AND TERMINATED A WIRE AT CONNECTOR D4528. OP TESTED GOOD IAW SWPM 20-00-12 AND AMM 33- 51-01.SDR CALA2017081102628Panel · out of adjustDOOR 2R SLIDE ARMED PLACARD STICKS IN INTERMITTANTLY WHEN DOOR IS ARMED. ADJUSTED DOOR 2R PANEL OPS CHECK GOOD.SDR CALA2017081102606Connector · brokenEMERGENCY LIGHT INOPERATIVE AT SEAT 5B, TROUBLESHOT AND FOUND CONNECTOR P1 UNDER SEAT 5B BROKEN IN HALF. REPLACED THE CONNECTOR IAW SWPM 20-61-28. OP CHECK PASSED IAW AMM 33-51-00SDR CALA2017081102604Control Switch · burnedSTRONG ELECTRICAL ACRID ODOR THROUGHOUT CABIN. REPLACED A BURNED APU CONTROL SWITCH IAW WDM 24-27-41. OPS CHECKED GOOD.SDR CALA2017081102591Angle · damagedR1 DOOR, INTERIOR ANGLE IS DAMAGED, JUST BELOW UPPER HINGE AND FWD OF DOOR MOUNTED TORQUE TUBE. REMOVED R1 DOOR IAW AMM 52-11-01. REMOVED AND REPLACED THE INTERIOR ANGLE IAW SRM 51-40-0 2. INSTALLED THE R1 DOOR IAW AMM 52-11 -01.SDR CALA2017081102589Strap · crackedFLOOR BEAM STABILIZATION STRAP IS CRACKED AT BS 345, BL0. ACCOMPLISHED A REPAIR IAW SRM 53-00-51, FIG 201, REPAIR 13.SDR CALA2017081102582Support Strap · crackedMEC BS 369, LBL 25 FLOORBEAM LWR SUPPORT STRAP HAS A CRACK AT A PREVIOUS REPAIR. ACCOMPLISHED A REPAIR BS 365 - 377, LBL 25 IAW SRM 53-00-51, FIG 201, REPAIR 12 AND 13.SDR CALA2017080802578Oven · smokeF/A REPORTED AFT GALLEY MIDDLE OVEN SMOKING REMOVED CONTENTS AND SECURED OVEN COMPLIED WITH A FUNCTIONAL TEST OF THE AFT GALLEY MIDDLE OVEN BOTH WITH CONTENTS IN THE OVEN AND NO CONTENTS IN THE OVEN. RAN THE OVEN FOR APPROXIMATELY FIVE MINUTES EACH TIME AND NOSDR CALA2017080802516Hook · missingL1 DOOR SLIDE ARMED WINDOW INDICATOR BANNER STOWAGE CLIP MISSING. SECURED DOOR SLIDE BANNER CLIP.SDR CALA2017080802495Connector · brokenFOUND THE EMERGENCY LIGHT INOPERATIVE AT ROW 5AB. TROUBLESHOT AND FOUND THE CONNECTOR P1 UNDER SEAT 5B BROKEN IN HALF. REPLACED THE CONNECTOR IAW SWPM 20-61-28. OP CHECK PASSED IAW AMM 33-51-00.SDR CALA2017080802494Fuse · failedFOUND THE EMERGENCY LIGHT INOPERATIVE AT THE L2 DOOR. TROUBLESHOT AND FOUND A BAD FUSE IN POWER SUPPLY M10567. REPLACED THE FUSE IAW AMM 33-51-07. OPS CHECK PASSED.SDR CALA2017080802493Fuse · failedFOUND EMERGENCY LIGHT INOPERATIVE AT ROW 4AB BULLNOSE. TROUBLESHOT AND FOUND A BAD FUSE IN THE POWER SUPPLY M10567. REPLACED THE FUSE IAW AMM 53-51-07. OP CHECK PASSED.SDR CALA2017080802484Intercostal · corrodedCORROSION ON AFT CARGO BAY INTERCOSTAL BS 1480-1500 BETWEEN STRINGERS 26R-27R. REMOVED & REPLACED THE INTERCOSTAL IAW SRM 51-40-02, PAR 4(B).SDR CALA2017080802483Frame Splice · crackedAFT CARGO BAY FRAME SPLICE AT BS 1480, STRINGER 22L IS CRACKED. LOCATED AND DRILLED A NEW FRAME SPLACE IAW SRM 51-40-05, DETAIL I,SDR CALA2017080802482Frame · corrodedCORROSION ON FRAME IN AFT CARGO BS 1480 RBL 17-18. REMOVED REPLACED THE FRAME IAW SRM 51-40-02, PAR 4 AND 7.SDR FDEA201708022094Rail · damagedNR 1 PYLON STRUT LT FAN COWL SUPPORT RAIL REQUIRES A SPLICE REPAIR NEAR NAC STA 93. COMPLIED WITH EA F-5400-T0334590 PART 1 , REMOVE DAMAGED SECTION. FABRICATED A REPLACEMENT SECTION, REPAIR ANGLE & TAPERED REPAIR STRAP & INSTALLED SPLICE REPAIR.SDR FDEA201708012086Actuator · failedAFTER TAKE OFF, RECEIVED AN AMBER GEAR LIGHT AND A GEAR DISAGREE MESSAGE ON EICAS. RAN CHECKLIST, PROBLEM DID NOT RESOLVE ITSELF. PUT GEAR DOWN AND RECEIVED A NORMAL THREE GREEN INDICATION. RETURNED TO DEPARTURE. THE NOSE LANDING GEAR LOCK ACTUATOR REMOVESDR FDEA201707292082Module · malfunctionedAT LEVEL FL360, RECEIVED A CONFIGURATION RED DISCRETE LIGHT AND GEAR NOT DOWN. RED EICAS MESSAGE RECEIVED AURAL ALERT AND INTERMITTENT EICAS MESSAGE DURING APPROACH. PERFORMED OPS CHECK OF LANDING CONFIGURATION WARNING MODULE. OPS CHECK FAILED. REMOVED ANDSDR CALA2017072902437Attach Bracket · crackedRT AFT UPPER WING TO BODY FAIRINGS NR 196ER AND NR 196DR SUPPORT STRUCTURE LOWER ATTACH BRACKET HAS A CRACK AT RADIUS ABOUT 1" LONG UPPER SIDE. REMOVED, LOCATED, DRILLED AND INSTALLED NEW RT AFT UPPER WTB FAIRINGS 196ER AND 196DR SUPPORT STRUCTURE LWR ATTACH BSDR CALA2017072902434Light · inoperativeEMERGENCY LIGHT ON SEAT 7B INOP. RELAMPED EMERGENCY LIGHT AT 7B, OPS CHECK GOOD.SDR CALA2017072802426Light · inoperativeSLIDE ARM LIGHT ABOVE DOOR 4L IS BURNT OUT. RELAMPED SLIDE ARMED LIGHT SLIDE OPS CHECK NORMAL.SDR FDEA201707262049Hinge Fitting · crackedLOWER HINGE FITTING AT BS 1640 LT SIDE IS CRACKED. REMOVED AND REPLACED THE HINGE FITTING IAW SRM 51-40-02.SDR CALA2017072802392Skin · crackedCROWN EDDY CURRENT FOUND A 1 INCH CRACK AT STRINGER 4L, BS 412. CONFIRMED CRACK IAW HFEC AND CONFIRMED CRACK IS AS STATED THRU EXT SKIN. REPAIR ACCOMPLISHED IAW ECRA5310-07165SDR FDEA201707242027Skin · dentedLEFT FUSELAGE SKIN, BETWEEN BS 395 AND 418, STRINGER 17L AND 18L. HAS A DENT THAT IS OUT OF LIMITS. CUT OUT DAMAGED AREA, FABRICATED & INSTALLED A REPAIR DOUBLER IAW SRM 53-00-01-2R, REPAIR 16.SDR CALA2017072402372Unknown · unknownEMERGENCY EXIT SLIDE LIGHT WILL NOT COME ON. CYCLED THE DOOR ARMING LEVER SEVERAL TIMES. OPS CHECKED GOOD.SDR FDEA201707222018Battery Pack · inoperativeDURING SERVICE CHECK, FOUND THE L1 DOOR SLIDE LIGHT AND FLIGHT COMPARTMENT EMERGENCY LIGHT INOPERATIVE DURING TEST. REMOVED AND REPLACED THE BATTERY PACK AT M730 IAW AMM 33-51-07-2. EMERGENCY LIGHTS NOW OPS CHECK GOOD.SDR CALA2017072102324Lens · missingEMERGENCY EXIT SIGN LENS AT LAV M MISSING. REPLACED MISSING EXIT SIGN LENS AT LAV M. OPS CK GOOD.SDR FDEA201707202007Frame · crackedLT FRAME BS 1640, STRINGER 14L FOUND CRACKED AT THE INBD AFT RADIUS. REPAIRED IAW EA F-5310-T0334370 P1.SDR CALA2017071702281Light · inoperative2L DOOR SLIDE ARMED LITE INOP. RELAMPED 2L DOOR SLIDE LIGHT. OPS CHECK NORMAL.SDR FDEA201707151969Power Supply · bentRIGHT EXTERNAL EMERGENCY SLIDE LIGHT FAILED AN OPS TEST. REPLACED THE POWER SUPPLY IAW MM 33-51-07-2, OPS CHECKED OK.SDR CALA2017071402220Extinguisher · malfunctionedLAVATORY FIRE EXTINGUISHING LAVATORY SMOKE ALARM ACTIVATED BY SMOKE, AUTOMATIC FIRE EXTINGUISHER DID NOT DISCHARGE AND TEMP INDICATOR STILL GRAY, LEFT AFT LAVATORY ALARM ACTIVATED BY SMOKE FROM GALLEY, OPERATES NORMALLY. OK TO CONTINUE.SDR CALA2017071002162Girt Bar · unsecureTHE L1 DOOR SLIDE ARM LIGHT WILL NOT ILLUMINATE . CHECKED THE L1 DOOR GIRT BAR ENGAGEMENT, LIGHT ILLUMINATED, ENGAGED SEVERAL TIMES, LIGHT CHECKED GOOD.SDR FDEA201707011816Life Vest · missingON PREFLIGHT, CAPTAIN/S LPU WAS MISSING. INSTALLED CAPTAINS LIFE VEST AT REAR OF CAPTS SEAT, REF DRAWING B57-25-011. OK FOR SERVICE.SDR CALA2017070102080Sensor · faultyRT OVERWING SLIDE DOOR LOCKED SENSOR FAULTED. REMOVED AND REPLACED RT OVERWING SLIDE DOOR LOCKED SENSOR S10374 AFTER TROUBLESHOOTING IAW AMM 52-71-00-825-211, 32-09-04 -004-001, 52-71-99-200-801C1, AND B757-2 WDM 20-30-12. ADJUSTMENT CHECKED GOOD IAW 52-71-00-SDR FDEA201706301787Relay · malfunctionedON A 5 MILE FINAL INTO KFAR WE HAD AN AIR GRND SYSTEM EICAS, UNSAFE MAIN CARGO DOOR INDICATION, AUTO BRAKE EICAS, LEFT AND RIGHT REV ISOLATION VALVE EICAS, ALONG WITH RED REV INDICATIONS ABOVE EPR INDICATOR, COMM 1 FAILURE, STANDBY ATT FAIL, AND LANDING GSDR CALA2017063002056Bulb · burned outL1 DOOR SLIDE ARM LIGHT NOT WORKING. FOUND SLIDE LIGHT HAD BURNED OUT BULBS . REPLACED THE BULBS, OPS CHECKED NORMAL.SDR CALA2017062602005Sensor · faulty1L SLIDE LIGHT ON WITH DOOR DISARMED REPLACED FWD GIRT BAR PROXIMITY SENSOR IAW MM 25-66-11, OP-CHECKS GOOD.SDR CALA2017062601989Doubler · corrodedAFT LAVATORY SERVICE CONNECTOR, INTERNAL AREA WHERE THE TEE PLUMBING ATTACHES, HAS BLUE WATER STAINS AND SIGNS OF CORROSION. CLEANED THE AFT LAVATORY SERVICE CONNECTOR IAW EC/RA 2011-01000, REV U. CORROSION ON DOUBLER HAS 100% MATERIAL LOSS AROUND CUT OUT FOSDR CALA2017062601981Inverter · inoperativeL2, R2, AND LEFT FORWARD OVERWING LOWER EMERGENCY EXIT SIGNS INOPERATIVE. RESEATED CONNECTOR D6660 ON LEFT EFD OVERWING SIGN IAW BSOPM 20-42-01 AND REMOVED AND REPLACED INVERTER M10826 IAW SRM 51-40-02, PG 7, AND BSWPM 20-42-01. OP CHECKED GOOD IAW AMM 32-51-SDR CALA2017062601980Battery Pack · inoperativeR1 DOOR UPPER EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 33-51-07-022-020, AND 33-51-07-862-054. OPS CHECKED GOOD IAW AMM 33-51-07-862-036.SDR CALA2017062301972Light · defectiveSLIDE ARMED INDICATOR LIGHT AT 1L IS FLICKERING. RELAMPED L1 SLIDE ARMED LIGHT INDICATOR. OPS CK GOOD.SDR CALA2017062301939Stringer Clip · gougedINBD FRAME TO STRINGER ATTACH ANGLE AT BS 1400, STRINGER 29L FOUND GOUGED. REMOVED AND REPLACED THE STRINGER CLIP IAW DWG 140N2003, SRM 51-40-02, AND 51-4 0-05.SDR FDEA201706211725Attach Fitting · dirtyR1 DOOR ESCAPE SLIDE ARM LIGHT STAYS ON WHEN DISARMED. T/S R1 DOOR SLIDE LIGHT. FOUND BOTH GIRT BAR ATTACH FITTINGS ON FLOOR DRY WITH NO LUBE AS WELL AS THE SLIDERS ON THE GIRT BAR. BOTH WERE COVERED IN A LIGHT FILM OF MOISTURE. SUSPECT FWD GIRT BAR ATTACH FITSDR CALA2017062301924Frame · corrodedBS 1400 FRAME IN AFT CARGO HAS CORROSION ON BOTH FWD AND AFT SIDES, STRINGERS 26L - 26R. BLENDED THE CORROSION ON THE FRAME AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00 -07, FIG 101. REMOVED, FABRICATED, LOCATED, DRILLED & INSTALLED A NEW FRAME IAW SRM 51SDR CALA2017062301923Intercostal · corrodedAFT CARGO INTERCOSTAL, BS 1400 - 1420 BETWEEN STR 29-30R HAS CORROSION. REMOVED THE CORROSION IAW SRM 51-10-02, FIG 1. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53, FIG 1 01, DETAIL IV, REMOVED AND REPLACED THE INTERCOSTAL IAW B757-200 51- 40-02 PARA 4, PARASDR FDEA201706201713Power Supply · inoperativeDURING PREFLT, FOUND LEFTT SLIDE LIGHT INOPERATIVE. REMOVED AND REPLACED THE LT EMERGENCY POWER SUPPLY IAW AMM 33-51-07-2. OPS CHECKED GOOD.SDR CALA2017061801879Lanyard · out of position2L WONT DISARM, REPOSITIONED DOOR 2L SLIDE BUSTLE. SURVIVAL ATTACH LANYARD INTERFERING WITH GIRT BAR ARMING PAWL. ALL OPS OK AFTER REPOSITIONING. PER AMM 25-66-00 NO ADJ NEEDED.SDR FDEA201706161684Line · failedIN CRUISE FLIGHT (FL390) RT PACK TEMP EICAS MESSAGE. SHORTLY THEREAFTER, RT PACK INOPERATIVE AND RT BLEED OFF EICAS WITH LIGHTS ON OVERHEAD PANEL. RAN QRH AND PRESSED EVENT RECORD. COULD NOT MAINTAIN CABIN ALTITUDE ON ONE PACK. BEGAN DESCENT. CABIN ALTITUDE SDR CALA2017060501708Sign · detachedEMERGENCY EXIT SIGN OVER THE L2 DOOR FELL OFF. ATTACHED THE SIGN.SDR CALA2017060401666Skin · corrodedCORROSION FOUND AT EXTERNAL POWER RECEPTACLE PAN AROUND CONNECTOR. REMOVED CORROSION ON EXTERNAL POWER RECEPTACLE PAN AROUND CONNECTOR IAW SRM 51-10-02, PAR 15, FIG 1. UT INSPECTION ACCOMPLISHED LOW READING .042 ORIGINAL THICKNESS .063 IAW DRAWING 141N8271. F
Back to Boeing 757-222