Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA02693Skin · damagedFUSELAGE SKIN STA 600 - 650 STR 17L - 18L IS DAMAGED. [08-17-07] MAJOR REPAIR ACCOMPLISHED. DENT MEETS ALL LIMITS SHOWN IN SRM EXCEPT DEPTH & A-Y RATIO. ACCOMPLISHED INTERIOR INSPECTION, NO STRINGER OF FRAME DAMAGE NOTED. REMOVED DAMAGE, HFEC OPEN HOLESDR 2007UALA02692Skin · crackedNR 2 RT MED CRACKED AT UPPER HINGE CUTOUT. [08-17-07] NR 2 RT MED CRACKED AT UPPER HINGE CUT OUT. INSTALLED DOUBLER REPAIR PER UA ENGINEERING SPECIFICATIONS.SDR 2007UALA02710Oxygen Mask · damagedPBE BY DOOR 2L IS RIPPED OPEN. 09-07-07 REPLACED SMOKE HOOD OF OXYGEN MASK.SDR 2007UALA02707Frame · dentedDENTED FRAME STA 1500, STR 25L IN AFT PIT. [08-17-07] MAJOR REPAIR ACCOMPLISHED. REPAIRED PER UA ENGINEERING SPECIFICATIONS.SDR 2007UALA02706Frame · dentedDENTED FRAME STA 1580 BETWEEN STR 25-26L IN AFT PIT. [08-17-07] MAJOR REPAIR ACCOMPLISHED. REPAIRED PER UA ENGINEERING SPECIFICATIONS.SDR 2007UALA02705Screw · corrodedR-1 DOOR SLIDE, CENTER GIRT BAR SUPPORT, 2 EACH SCREWS CORRODED. [08-17-07] REPLACED SUPPORT PLATE.SDR 2007UALA02704Support · corrodedL-2 DOOR SLIDE, CENTER GIRT BAR ATTACH SUPPORT, ON SLIDE ASSY, IS CORRODED. [08-17-07] REPLACED SUPPORT PLATE.SDR 2007UALA02703Support · corrodedR-4 DOOR SLIDE, CENTER GIRT BAR SUPPORT IS CORRODED. [08-17-07] REMOVED AND REPLACED SUPPORT PLATE.SDR 2007UALA02702Strap · looseR2 DOOR WILL NOT ARM. [08-17-07] REMOVED BUSTLE, TIGHTENED STRAPS AND OPS CHECKED OKAY. REINSTALLED BUSTLE.SDR 2007UALA02691Threshold · crackedCENTER OF LOWER THRESHOLD FOR FWD CARGO DOOR CUTOUT HAS A 1 INCH DENT WITH A CRACK. [08-17-07] MAJOR REPAIR NEEDED AT THE DOORWAY SCUFF PLATE. TWO CRACKS HAVE BEEN STOP DRILLED, EACH BEING LESS THAN 1.5" LONG, REMOVED DENTED SCUFF PLATE. INSTALLED SCUFF SDR 2007UALA02688Structure · damagedFOUND DAMAGE ON AFT CARGO DOOR ON LOWER AFT CORNER. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE. INSTALLED DOUBLER REPAIR & PERFORMED FILLET SEAL.SDR 2007UALA02687Blower · faultySTATUS MESSAGE AFT CARGO DETECTOR 1. [08-17-07] FOUND BLOWER NOT OPERATING PROPERLY. REPLACED BLOWER.SDR 2007UALA02643Pressure Panel · damagedDURING HMV CORROSION DAMAGE REPAIRS WERE ACP AT AFT PRESS DECK BS 1681 BETWEEN RBL 8.75 - 10.25 & BS 1697 RBL 50.25.SDR 2007UALA02646Fan · odorOILY ODOR ON TAKEOFF AND CLIMB. PRETTY STRONG ODOR. TURNED THE RT RECIRCULATION FAN OFF. LESSENED THE ODOR.SDR 2007UALA02633Unknown · unknownRTFL DUE TO A PRESSURIZATION PROBLEM.SDR 2007UALA02650Power Supply · inoperativeMED 2R UPPER EMERGENCY EXIT SIGN INOP ALONG WITH EEL LIGHTING AT SEATS 2AB, 3AB, 9AB, 10AB & 11AB. [07-27-07] REPLACED POWER SUPPLY. CHECKS GOOD.SDR 2007UALA02649Warning Message · unknownGEAR DISAGREE EICAS MSG AND LIGHT ILLUMINATED UPON SELECTING GEAR HANDLE DOWN.SDR 2007UALA02647Lamp · inoperativeEXTERIOR EMERGENCY LIGHT INOP AT DOOR 2R AND RT AFT OVERWING. [07-27-07] RELAMPED.SDR 2007UALA02632Lanyard · out of positionGIRT BAR WILL NOT ENGAGE DOOR 1R.SDR 2007UALA02631Unknown · odorACFT RETURN TO BLOCK DUE TO BURNING ODOR FROM AFT GALLEY AREA.SDR 2007UALA02629Skin · crackedMED 2R UPPER HINGE CUTOUT CRACKED. MAJOR REPAIR ACCOMPLISHED: INSURANCE CUT & INSTALLED A DOUBLER REPAIR.SDR 2007UALA02648Unknown · warning messageSTATUS MESSAGE NOSE A-G DISAGREE.SDR 2007UALA02645Lever · stiffTHE 1L ARMING LEVER IS VERY STIFF.SDR 2007UALA02644Battery · faultyLEFT & RIGHT FWD EMERGENCY LIGHTS INOP, EXTERIOR. [07-27-07] TROUBLE SHOOT AND REPLACED BATTERY. OPS CHECK GOOD.SDR 2007UALA02625Trim System · failedRUDDER TRIM FAILED TO TRIM IN EITHER DIRECTION.SDR 2007UALA02624Lanyard · out of positionDOOR 1R WILL NOT ARM.SDR 2007UALA02620Fitting · gougedRIGHT WING (PYLON) FITTING (SIDE LINK) FASTNER HOLE AT LOCATION F ON WING HAS INTERNAL GOUGE DAMAGE. 09-07-07 MAJOR REPAIR ACCOMPLISHED. PANEL ON PYLON 432AR UPPER RIGHT HAS DELAMINATION DUE TO HEAT. REPAIRED PANEL PER UA ENGINEERING SPECIFICATIONS.SDR 2007UALA02619Skin · dentedLEFT EXTERNAL FUSELAGE AT EXISTING REPAIR DOUBLERS STA 520-660, STR 14L-20L, SKIN HAS NUMEROUS DENTS.SDR 2007UALA02611Controller · faultyWINDOW EICAS MSG DISPLAYED, POSITION 4.(1=L FWD, 2=L SIDE, 3=R FWD, 4=R SIDE) INOP LIGHT ILLUM. INOP LIGHT DID NOT EXTINGUISH WHEN SWITCH WAS RECYCLED TO OFF THEN ON. CREW COMMENTS: IT HAPPENED AGAIN.SDR 2007UALA02610Oxygen Mask · faultyTHE O2 MASKS DID NOT DROP DURING OPS CHECK IN MAIN CABIN AT ROWS 6AB, 4AB, 4CD, 10ABC, 27ABC & FWD F/A SEAT. [08-17-07] ELECTRICAL OPS CHECK TURNED OUT TO BE SUCCESSFUL. RELOCATED GREEN LANYARD AND RESET PLUNGER.SDR 2007UALA02591Lanyard · out of positionFWD RT ENTRY DOOR WILL NOT ARM. [08-08-07] RESECURED LANYARD CORD INTERFERRING WITH GIRT BAR.SDR 2007UALA02589Skin · damagedLEFT EXTERNAL FUSELAGE AT EXISTING REPAIR DOUBLER, FOUND STR 16L AT STA 625 HAS AN ENLARGED HOLE. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE SECTION OF STRINGER. FABRICATED & INSTALLED A STRINGER SECTION & SPLICE ANGLES.SDR 2007UALA02585Unknown · odorSTBY INVERTER STATUS MESSAGE FOLLOWED ABOUT 4 MINS LATER WITH A REPORT FROM THE F/A'S OF A PLASTIC OVERHEATING TYPE OF ODOR IN THE CABIN. CREW TURNED UTILITY BUSSES AND RECIRC FANS OFF AND ODOR DISSIPATED. NO SMOKE OBSERVED PER CREW. REPLACED STATIC INVERTSDR 2007UALA02584A/C Pack · odorFOUL ODOR IN AIR COND SYSTEM DURING DESCENT AT IDLE. MAINT TEXT: CREW REPORTED, OIL BURNING ODOR IN COCKPIT & FWD CABIN. CREW SUSPECT ODOR IS FROM LT PACK. ODOR - OIL BURNING ODOR WAS DETECTED ON GROUND WITH PACKS ON. [08-08-07] CREW SUSPECT ODOR IS FSDR 2007UALA02583Bearing · dryDOOR 4R WILL NOT ARM. ARMING MECHANISM HAS DRY BEARINGS, FOUND MOVEMENT STIFF. REMOVED DOOR LINING AND SLIDE. LUBED ARMING MECHANISM AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR 2007UALA02558Light · damagedFOUR EEL LIGHTING END CAPS MISSING THROUGHOUT CABIN. [08-17-07] REPLACED MISSING END CAPS.SDR 2007UALA02548Charger · inoperativeMAIN BATTERY CHARGER DISPLAYED. [08-08-07] REPLACED MAIN BATTERY CHARGER WITH APU BATTERY CHARGERSDR 2007UALA02547Charger · inoperativeMAIN BATTERY CHARGER WILL NOT ERASE ON ECS MSG. [08-08-07] REPLACED MAIN BATTERY AND MAIN BATTERY CHARGERSDR 2007UALA02546Charger · unknownMAIN BATTERY CHARGER STATUS MESSAGE DISPLAYED. [08-08-07] REPLACED AC MAIN BATTERY AND CHARGER.SDR 2007UALA02522Mechanism · faultyBOTH AFT DOORS ARMING MECHANISM FELT DIFFERENT. [08-08-07] 4 LT LUBED AND ADJUSTED CAM PLATE 4 RT REMOVED BEARING PLATE AND REPLACED BEARING.SDR 2007UALA02501Unknown · unknownSTAB TRIM WILL NOT TRIM IN NOSE DOWN DIRECTION WITH CENTER STAB TRIM CUTOUT SWITCH IN NORMAL AND RIGHT STAB TRIM SWITCH IN CUTOUT POSITION. TRIMS NORMALLY WITH TRIM LEVERS. [08-08-07] STABILIZER NOSE DOWN OPERATION STARTED WORKING OKAY AFTER CYCLING STASDR 2007UALA02495Control Valve · malfunctionedUNABLE TO COOL CABIN. TEMP IN CABIN ABOVE 85 DEGREES. TRIED ALL CONFIGURATIONS. TRIM AIR OFF, STDBY COLD, ONE PACK AT A TIME, BOOSTING ENGINE BLEEDS, ALL NO HELP. [08-08-07] DURING PACK OPERATIONAL TEST FOUND LEFT PACK TEMP CONTROL VALVE FAULT ON BITE BOSDR 2007UALA02500Track · dirtyF/A REPORTED DOOR 3L WAS HARD TO ARM, ARMING LEVER VERY STIFF. [08-08-07] REMOVED DEBRIS FROM ARMING TRACK. OPERATION IMPROVED.SDR 2007UALA02499Oxygen Bottle · defectiveBOTH O2 BOTTLES FROM ROW 34 USED. ONE APPEARS TO BE DEFECTIVE. [08-08-07] REPLACED DEFECTIVE 02 BOTTLE IN OVERHEAD BIN AT SEAT 34ABC.SDR 2007UALA02498Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 1R. [07-27-07] RELAMPED.SDR 2007UALA02494Girt Bar · corrodedR-4 DOOR, GIRT BAR RESTRAINT PLATE CORRODED. [08-08-07] REPLACED GIRT BAR RESTRAINT FITTING.SDR 2007UALA02452Proximity Switch · faultyCREW REPORT, 3L SLIDE ARM LIGHT DOES NOT ILLUMINATE. [08-08-07] SUSPECT FLOOR MOUNTED PROX SWITCHES MIGHT BE BAD. REPLACED AND TESTED OKAY.SDR 2007UALA02447Trim System · malfunctionedFLIGHT DIVERTED WITH STABILIZER TRIM PROBLEM. [08-08-70] REPLACED STAB TRIM LIMIT SWITCH AND POSTION TRANSMITTER MODULE.SDR 2007UALA02445Proximity Sensor · obstructedDOOR 2R GIRT BAR ENGAGEMENT LIGHT WILL NOT COME ON WHEN ARMING DOOR. *S/D* REMOVED DEBRIS FROM PROX SENSOR AREA. REPLACED FWD GIRT BAR PROX SENSOR & ADJUSTED.SDR 2007UALA02438Light · inoperativeEXTERIOR EMERGENCY LIGHT AT 1R, 4R & 4L ARE INOPERATIVE. [07-27-07] RELAMPED.
Back to Boeing 757-222