Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA00997Intercostal · crackedR-1 DOOR INTERCOSTAL CRACKED AT LIGHTNING HOLE WHERE HANDLE BOX CONTROL ROD PASSES THROUGH. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. FABRICATED/ INSTALLED DOUBLER FILLER REPAIR.SDR 2007UALA00996Gate · damagedL1 DOOR UPPER GATE IS CRACKED AND CORRODED EXCESSIVELY. [06-14-07] REPLACED UPPER GATE ASSY. THIS IRREGULARITY IS ATTRIBUTED TO A UNFAVORABLE ENVIRONMENT LEADING TO CORROSION.SDR 2007UALA00995Access Door · corrodedFWD LAV DUMP ACCESS DOOR CUTOUT, FWD LAND IS CORRODED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2007UALA00978Light · inoperativeEMERGENCY LIGHTS - THE FOLLOWING ARE INOP: EXIT DOOR 2R, SEAT ROWS 2 AND 3 AND STOW BIN LIGHT AFT OF 3AB. REMOVED AND REPLACED LAMPS, OPS CHECK GOOD.SDR 2007UALA00977Stringer · damagedDURING REWORK OF TAIL STRIKE REPAIR AT BS 1742, DAMAGE WAS INCURRED TO STR'S 29L, 29R AND REPAIRED PER EVA IMC-00680A. [06-14-07] MAJOR REPAIR ACCOMPLISHED. REPAIRED PER UA SPEC AFTER DTA RESULTS, IT HAS BEEN DETERMINED THAT THESE REPAIR'S ARE CONSIDERESDR 2007UALA00976Light · inoperativeDOOR R1 SLIDE ARMED LIGHT ABOVE DOOR INOPERATIVE. [06-14-07] REPLACED PROXIMITY SWITCH S10217.SDR 2007UALA00975Spring · brokenDOOR 4R SLIDE SPRING FOR CLIPS BROKEN. [06-14-07] REPLACED SLIDE.SDR 2007UALA00974Annunciator · inoperativeDOOR 2L SLIDE ARMED LIGHT INOPERATIVE. [06-14-07] REPLACED L405 GIRT BAR ANNUNCIATOR.SDR 2007UALA00973Connector · disconnectedEMERGENCY LIGHTS INOP ROW 9 THRU ROW 13. FOUND POWER STRIP DISCONNECTED. RECONNECTED STRIP AND LIGHTS ILLUMINATE CORRECTLY.SDR 2007UALA00950Jumper · faultyCABIN FLOOR EEL LIGHT STRIP FEEDER AND JUMPER CONNECTION. REPLACED FEEDER AND JUMPER AND OPS CHECKED OK.SDR 2007UALA00949Power Supply · inoperativeL-2 EMERGENCY LIGHT INOPERATIVE. [SUP 4-17-07] REPLACED EMERGENCY POWER SUPPLY CHARGER. OPS CHECKS NORMAL.SDR 2007UALA00935Proximity Switch · inoperativeDOOR SLIDE LIGHT DOOR 2R DOES NOT ILLUM WHEN ARMED. [06-14-07] CHANGED LIGHT UNIT - NO HELP. REPLACED LIGHT BASE OPS CHECK NORMAL. REPLACED PROX SWITCH S10220 FOR ULTIMATE FIX.SDR 2007UALA00931Web · corrodedMAIN CABIN SHEAR WEB CORRODED STA 1681, RBL 16 TO RBL 50. *S/D* MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA. INSTALLED DOUBLER-TRIPLER FILLER REPAIR.SDR 2007UALA00930Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED STA 1681, BL 0 (AFT SHEAR WEB DECK PLATE). *S/D* MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA. INSTALLED DOUBLER-TRIPLER FILLER REPAIR.SDR 2007UALA00929Frame · dentedAFT PIT STA 1440 AT STR 26L FRAME DENTED. *S/D* MAJOR REPAIR ACCOMPLISHED: TRIMMED OUT DAMAGED INBOARD FLANGE. INSTALLED A NESTED J-ANGLE DOUBLER.SDR 2007UALA00928Wire Harness · damagedAISLE LIGHT AT STA 590, RBL 30 AND AISLE LIGHT AT STA 1430, LBL 30, WIRE HARNESS DAMAGED. [SUP 4-17-07] REPAIRED EEL LIGHT AT STA 590, RBL 30 WIRE HARNESS PER BSWPM 20-30-12. REPLACED WIRE HARNESS TO AISLE EEL LIGHT AT STA 1430.SDR 2007UALA00927Lamp · inoperativeL-1 DOOR AND R-3 DOOR EXTERIOR EMERGENCY LIGHTS INOP. [SUP 4-17-07] RELAMPED L1 DOOR AND R3 DOOR EXTERNAL EEL LIGHTS. OPS CHECK GOOD.SDR 2007UALA00903Lanyard · mislocatedDOOR 2L SLIDE PACK LANYARD NOT VISIBLE. [06-14-07] FOUND D-RING STUCK UNDER SLIDE PACK. REPLACED LANYARD.SDR 2007UALA00901Pressure Panel · damagedAFT PRESSURE DECK BS 1681.80 AT RBL 40 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED DOUBLER/FILLER REPAIR.SDR 2007UALA00890Floorbeam · corrodedMAIN DECK FLOORBEAM AREA, WEB IS CORRODED AT BS 960, RBL 67. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED FLOORBEAM WEB.SDR 2007UALA00889Skin · puncturedFUSELAGE SKIN HAS PUNCTURE AT BS 700, STR 26L. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SKIN. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2007UALA00888Frame · crackedWEB FRAME BETWEEN FRAMES 500-480, RBL 12, TOP OF WEB IS CRACKED. MAJOR REPAIR ACCOMPLISHED: REMOVED WEB & TOP OF WEB. FABRICATED & INSTALLED ANGLE REPAIR.SDR 2007UALA00886Battery Pack · inoperativeFLOOR EMERGENCY LIGHTS FROM ROWS 9 - 15 NOT WORKING. SUP 4-17-07. REPLACED BATTERY PACK.SDR 2007UALA00884Skin · gougedFUSELAGE SEC 48 LEFT UPPER SKIN 1 INCH GOUGE AT STA 1782, APPROX 14 INCHES FROM VERT STAB. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. INSTALLED DOUBLER REPAIR & FLUSH BRILES.SDR 2007UALA00887Lamp · inoperativeDOOR 4R EMERGENCY LIGHT INOPERATIVE. SUP 4-17-07. RELAMPED, OP CK GOOD.SDR 2007UALA00885Regulator · faultyOXYGEN MASK DEFECTIVE AT 1=CAPT, 2=1ST OFF, 3=1ST OBS. CREW COMMENTS: INFLATABLE HARNESS DOESN'T INFLATE. [06-14-07] REPLACED MASK AND REGULATOR AI NR 1 POSITION OF PILOT AND 1ST OFFICER SEATS.SDR 2007UALA01615Feeder Cable · severedALL FIRST CLASS EGRESS STRIP INOPERATIVE. FOUND MAIN POWER FEED SEVERED AT ROW 2AB, REPLACED POWER FEED CABLE. OP CHECKS OKAY.SDR 2007UALA00869Warning System · activatedAFTER PUTTING GEAR DOWN GOT GEAR DISAGREE LIGHT & CORRESPONDING EICAS MSG. 4-17-07....SUP. TAPPED OR PUSHED DOWN ON THE LND GR CNTRL HANDLE EICAS MSG WENT AWAY AND DID NOT COME BACK, NO EICAS MSG RECORDED AGAIN. NO FAULTS FOUND ON PROX ELECT UNIT. DUE TO NO SDR 2007UALA00868Chain · misroutedMED 1LH HARNESS LATCH CHAIN MISROUTED OVER HARNESS FITTING. [06-14-07] ACCOMP'D ROUTINE JC'S TO RESTORE DOOR AND SLIDE TO NORMAL SAFE CONDITION. REROUTED CHAIN TO CORRECT POSITION.SDR 2007UALA00857Bottle · underservicedLOW PRESSURE ON CYLINDER. [SUP 05-16-07] BOTTLE WAS UNDERFILLED. FILLED BOTTLE TO SPECIFICATIONS.SDR 2007UALA00845Frame · gougedFUSELAGE STR 29R AT STA 1743 HAS 2 SHEARED RIVETS. FUSELAGE FRAME HAS DEEP GOUGES STA 1720 BETWEEN STR 29L TO OUTBOARD OF STR 29R. SKIN GROUND AWAY STA 1720 STR 29L TO JUST OUTBOARD OF STR 29R. [06-14-07] MAJOR REPAIR ACCOMPLISHED. CHORD REPAIRS 3 EA ARE SDR 2007UALA00844Bulkhead · buckledAFT PRESSURE BULKHEAD STA 1720 HAS A BUCKLE IN ITS WEB, ABOUT ONE QUARTER INCH DEFLECTION BY 18 INCHES LONG. FIVE INCHES FROM THE BOTTOM, BETWEEN THE TWO VERTICAL BEAMS AT LBL 9.20 AND RBL 9.20 DAMAGE TO FOLLOWING AREAS: GOUGES STA 1720 STR 29L TO OUTBOARD SSDR 2007UALA00843Skin · damagedDURING DEPARTURE A/C OVER-ROTATED STRIKING THE RUNWAY AT BS 1715-1787. AFT SKIN PANEL & FWD SKIN PANEL ABRAIDED 100 PERCENT AT STA 1720. STA 1720 FWD CHORD & AFT CHORD WERE ABRAIDED AT LEAST 30 PERCENT, AND THE AFT PRESSURE BULKHEAD LWR WEB WAS FOUND BUCKLEDSDR 2007UALA00822Frame · inadequateDOOR 2R FWD FRAME IS INADEQUATE. MAJOR REPAIR ACCOMPLISHED: INSTALLED FWD FRAME STEEL DOUBLER.SDR 2007UALA00797Filter · cloggedLANDED UNDER AMBER ALERT DUE TO LOSS OF LEFT HYDRAULIC PRESSURE. REPLACED EDP FILTER MODULE ELEMENT IN LEFT TAIL SAIL AREA. CLEANED AREA AND SERVICED HYDRAULIC SYSTEM AND OPERATED FLIGHT CONTROL SYSTEM FOR FINAL TESTING.SDR 2007UALA00810Bolt · damagedLEFT WING, OUTBOARD FLAP, OUTBOARD FLAP DRIVE, FOREFLAP ATTACH FITTING, 3 OF 4 BOLTS MISSING, BROKEN, WITH FITTING SEPARATING FROM ITS MOUNTING POINT (4TH LOCK FASTENER IS LOOSE AND ABOUT TO SHEAR). [SUP 06-14-07] REMOVED AND REINSTALLED FITTING WITH OVERSISDR 2007UALA00813Shear Tie · corrodedAFT PIT STA 1360 BETWEEN STR 29R-28R SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED NEW TIE.SDR 2007UALA00831Warning System · malfunctionedEVAC ALARM HAS ACTIVATED AT ALL STATIONS ALL BY ITSELF. PRESSED HORN SHUTOFF, NO HELP. [SUP 06-14-07] TESTED EVAC SYSTEM PER UA ENGINEERING SPECIFICATIONS. SYSTEM TESTED GOOD. NO DEFECTS NOTED. UNABLE TO ESTABLISH ANY CAUSE FOR THIS IRREGULARITY EVENT.SDR 2007UALA00812Skin · corrodedFWD CARGO LEFT SIDE WALL LAV SERVICE PORT UPPER SKIN CORRODED AROUND DUCT AT STA 705-711, STR 19L-21. MAJOR REPAIR ACCOMPLISHED. REPLACED DOUBLER.SDR 2007UALA00811Floorbeam · corrodedMAIN CABIN FLOORBEAM T-CAP CORROSION, STA 1640 RBL 56-59. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED SECTION. INSTALLED NEW T-CAP SECTION.SDR 2007UALA00789Door Frame · crackedTHE 2L MED UPPER HINGE FRAME CUTOUT LWR RADIUS CRACKED. MAJOR REPAIR ACCOMPLISHED: COMPLETED A DOUBLER REPAIR ACCORDING TO A BOEING APPROVED REPAIR.SDR 2007UALA00779Unknown · vibrationFLIGHT DIVERTED DUE TO AN AIRFRAME VIBRATION. UNIDENTIFIED RUMBLE- VIBRATION VERY STRONG AFT GALLEY MIDDLE FLOOR. FOUND WATER FILL VALVE OPEN, CLOSED VALVE. SERVICE PANEL HAD ICE CHUNKS BANGING AROUND INSIDE CAUSING NOISE. CLEANED OUT PANEL AND CLOSED. REMOVSDR 2007UALA00774Bulkhead · crackedNR 2 ENGINE STRUT BULKHEAD CRACKED AT MAIN FUEL LINE CLAMP BLOCK CONNECTION AT NAC STA 102.1. MAJOR REPAIR ACCOMPLISHED: REMOVED 3 ANGLES, 2 FILLER, 2 SEALS AND VBAND. REMOVED WEB. INSTALLED NEW WEB, ANGLES AND FILLERS. INSTALLED VBAND RETAINER AND 2 SEALS.SDR 2007UALA00767Light · faultyEEL LIGHT BAR IN FRONT OF THE AFT LAV IS INOPERATIVE. REPAIRED AFT LAV LIGHT BAR.SDR 2007UALA00759Girt Bar · out of adjustDOOR 1L WILL NOT ARM. ADJUSTED GIRT BAR FLOOR LOCK, DOOR OPS CHECK OK.SDR 2007UALA00757Battery Pack · inoperativeRIGHT OVERWING EXIT EMERGENCY LIGHT INOPERATIVE. [SUP 4-17-07] RELAMPED L563 SLIDE LIGHT AT RIGHT AFT OVERWING EXIT, BUT LIGHT STILL INOP. REPLACED RT WING BATTERY PACK AND OPS CHECK GOOD.SDR 2007UALA00747Bottle · no test2R EMERGENCY ESCAPE SLIDE FAILS TEST. [SUP 05-22-07] REMOVED AND REPLACED BOTTLE ASSY. OPERATIONAL TEST OK.SDR 2007UALA00746Lamp · inoperativeDOOR 3R SLIDE ARMED LIGHT INOPERATIVE. [SUP 05-29-07] RELAMPED. OP CHECKED NORMALLY.SDR 2007UALA00743Floorbeam · corrodedRIGHT FWD MAIN CABIN FLOOR STRUCTURE, FLOORBEAM UPPER CHORD ON UPPER AND LOWER SURFACES CORRODED AROUND FASTENER HOLES IN MULTIPLE PLACES, BS 365.25, RBL 0 TO RBL 64. MAJOR REPAIR ACCOMPLISHED: RMV'D CORROSION. FABRICATED & INSTALLED REPAIR ANGLE & STRAP.SDR 2007UALA00742Torque Tube · damagedL-1 DOOR LOWER GIRT BAR LINKAGE TORQUE TUBE IS GOUGED AND CORRODED. [SUP 05-22-07] L-1 DOOR LOWER GIRT BAR LINKAGE TORQUE TUBE IS GOUGED AND CORRODED. REPLACED TORQUE TUBE DURING DOOR OVERHAULS.
Back to Boeing 757-222