Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2002UALA00407Frame · corrodedMID CABIN LEFT HAND SIDE, BODY STATION 1020 FUSELAGE FRAME CORRODED AT AFT OB AREA 3 INCHES ABOVE FLOOR LEVEL AND LWR INBD SURFACE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. CHORD, SPLICE REPLACED.SDR 2002UALA00410Floorbeam · gougedCABIN FLOORBEAM GOUGED, STATION 680 LBL 22, UPPER CAP OF CABIN FLOOR. MAJOR REPAIR ACCOMPLISHED. T-CAP REPAIR INSTALLED.SDR 2002UALA00391Stringer · dentedSTATION 602-604 STRINGER 16L DENTED. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRINGER SPLICE.SDR 2002UALA00390Crease Beam · corrodedCABIN DOOR 2 LEFT LOWER CREASE BEAM CORRODED, STATION 663-754 WATERLINE 208, STRINGER 17 LEFT. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM.SDR 2002UALA00389Crease Beam · corrodedMID CABIN RIGHT HAND CREASE BEAM WEB EXFOLIATED BETWEEN STATION 940-944 STRINGER 17 RIGHT, WATERLINE 208. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM WEB.SDR 2002UALA00375Crease Beam · corrodedCABIN FLOOR CREASE BEAM WEB UPPER SURFACE CORRODED AT OUTBOARD EDGE AROUND ATTACH FASTENERS AT THREE PLACES BETWEEN BODY STATION 960 AND BODY STATION 984, RBL 68.50 AND WL208. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM.SDR 2002UALA00376Pressure Panel · corrodedCABIN AFT PRESSURE DECK HAS EXCESSIVE MATERIAL LOSS AT STATION 1681 RBL 12, STATION 1681 TO 1684 RBL 14 TO RBL 54, STATION 1688 RBL 50 AND STATION 1699 RBL 44. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2002UALA00353Windshield · crackedACRID SMELL AND SPARKS FROM RIGHT WINDSHIELD HEAT. RIGHT WINDSHIELD CRACKED. MOISTURE INGRESSION OF 1ST OFFICERS WINDSHIELD CAUSED ARCING OF THE HEATING ELEMENT. REPLACED WINDSHIELD ASSY AND WINDOW HEAT CONTROLLER.SDR 2002UALA00354Bearing · failedRIGHT NOSE WHEEL BEARING FAILED ON TAXI. SMOKE AND SMALL FLAME FROM WHEEL. RT NLG OUTBOARD BEARING FAILED. REPLACED NLG AXLE AND BOTH NLG WHEELS. PERFORMED NWS TEST.SDR 2002UALA00356Crease Beam · damagedCABIN CREASE BEAM INNER CHORD LOWER LEG, HAS EXCESSIVE MATERIAL LOSS AT FASTENER HOLE BODY STATION 753, LBL 65, WATERLINE 208. MAJOR REPAIR ACCOMPLISHED. INNER CHORD REPLACED.SDR 2002UALA00355Floorbeam · gougedSTATION 1600, FLOORBEAM CAP RBL 5 TO LBL 18 HAS GOUGES IN AREA OF AFT CABIN. MAJOR REPAIR ACCOMPLISHED. FLOORBEAM DOUBLER INSTALLED.SDR 2002UALA00339Frame · dentedFRAME DENTED IN FORWARD PIT STATION 580 STRINGER 23L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR ON FRAME.SDR 2002UALA00341Frame · damagedFUSELAGE FRAME AT STATION 1420 JUST ABOVE STRINGER 26L DAMAGED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.DOUBLER INSTALLED ON FRAME.SDR 2002UALA00340Pressure Panel · corrodedSTATION 1681 TOP OF AFT PRESSURE DECK RBL 12 TO LBL 4 HAS AREAS OF CORROSION. MAJOR REPAIR ACCOMPLISHED. DOUBLER INSTALLED OVER PRESSURE DECK.SDR 2002UALA00331Frame · dentedAFT PIT LEFT HAND SIDE FRAME DENTED AT STATION 1540, ABOVE STR 26L. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR INSTALLED.SDR 2002UALA00288Stringer · gougedFUSELAGE STATION 297 STRINGER 2L HAS DEEP GOUGE ON STRINGER. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER.SDR 2002UALA00273Generator · inoperativeDIVERTED DUE TO GENERATOR INOP AND APU FAILED TO START. NO EICAS STATUS MESSAGES FOR THE APU. NORMAL START ACCOMPLISHED ON THE GROUND.SDR 2002UALA00264Skin · dentedFUSE SKIN AT BODY STATION 760, BELOW STRINGER 16L, DENTED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.SKIN DOUBLER INSTALLED.SDR 2002UALA00267Floorbeam · corrodedCABIN FLOORBEAM AT STATION 324, RBL 41.60 CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2002UALA00266Floorbeam · corrodedAFT CABIN STATION 1681 RBL 53 CORROSION BETWEEN FLOORBEAM CAP AND PRESSURE DECK. MAJOR REPAIR ACCOMPLISHED. INSTALLED FLOORBEAM CAP SPLICE.SDR 2002UALA00265Web · corrodedLEFT HAND CABIN WEB STATION 1640 JUST BELOW STRINGER 7L CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP REPAIR.SDR 2002UALA00263Channel · corrodedHAT CHANNEL AT STATION 324 RBL 344 CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED HAT CHANNEL.SDR 2002UALA00258Structure · corrodedCABIN AFT SHEAR DECK UPPER SURFACE CORROSION WITH EXCESSIVE MATERIAL LOSS STATION 1680 TO 1682 LBL 10 TO LBL 41. MAJOR REPAIR ACCOMPLISHED. DOUBLER AND TWO ANGLES INSTALLED.SDR 2002UALA00257Frame · damagedSTATION 1520 BETWEEN STRINGER 23R AND STRINGER 25R, EDGE OF FRAME DAMAGED AT RBL 36.5, 39.25, 41.5 AND 49 RESPECTIVELY. MAJOR REPAIR ACCOMPLISHED. INSTALLED ANGLE REPAIR.SDR 2002UALA00256Stringer · gougedSTATION 1280 ABOVE STRINGER 26R GOUGED AND HAS EXCESS MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. INSTALLED ANGLE REPAIR.SDR 2002UALA00255Web · damagedRIGHT HAND AFT CABIN STATION 1640 FLOOR BEAM WEB DAMAGED AT RBL 56, ALSO FLOOR BEAM CAP CORRODED AROUND FASTENER HOLES BETWEEN RBL49-52. MAJOR REPAIR ACCOMPLISHED.INSTALLED ANGLE DOUBLER ON CAP AND WEB DOUBLERS ON INTERCOSTAL.SDR 2002UALA00251Carbon Seal · wornSMOKE FILLED AIRCRAFT IMMEDIATELY AFTER TAKEOFF. UPON DISASSEMBLY AT THE TURBINE SHOP, THE NR 3 BEARING AFT CARBON SEAL WAS FOUND WORN.SDR 2002UALA00249Carbon Seal · wornSMOKE FILLED AIRCRAFT IMMEDIATELY AFTER TAKEOFF. UPON DISASSEMBLY AT THE TURBINE SHOP, THE NR 2/3 CARBON SEAL WAS FOUND WORN.SDR 2002UALA00254IntercostalAFT CABIN BETWEEN STATION 1640 TO STA 1660, BL0, INTERCOSTAL NEEDS REMOVAL FOR ACCESS. MAJOR REPAIR ACCOMPLISHED. INTERCOSTAL REMOVED AND REINSTALLED WITH NEW ANGLES AND SPACERS.SDR 2002UALA00252Skin · dentedLEFT HAND EXTERNAL FUSELAGE HAS A 6 INCH VERTICAL DENT AT BODY STATION 760 BETWEEN STRINGER 15L TO 16L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2002UALA00253Floorbeam · corrodedSTATION 1681 CABIN FLOORBEAM TOP CAP LOWER SURFACE CORRODED AT LBL 24 - LBL 32. MAJOR REPAIR ACCOMPLISHED. INSTALLED CAP STRAP REPAIR.SDR 2002UALA00229Frame · dentedAFT PIT STA 1540 ABOVE STRINGER 25L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR ON FRAME.SDR 2002UALA00236Frame · corrodedSTATION 1681 STRINGER 17R FRAME CORRODED AT FLOOR Z ANGLE. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR ON FRAME.SDR 2002UALA00235Clip · corrodedAFT PIT FRAME CLIP CORRODED STATION 1500 RBL17. MAJOR REPAIR ACCOMPLISHED. CLIP REMOVED AND CORROSION REMOVED FROM CLIP AND AFT LIP OF FRAME THEN CLIP REINSTALLED.SDR 2002UALA00234Floorbeam · gougedBODY STATION 640 BL 0 RBL 22 FLOORBEAM TOP SURFACE GOUGED. MAJOR REPAIR ACCOMPLISHED. CUT AWAY DAMAGED AREA AND INSTALLED T-CAP REPAIR.SDR 2002UALA00233Frame · damagedFORWARD E & E ACCESS HOLE STATION 223.5 RBL 29" FRAME IS DAMAGED FROM FASTENER GOING THRU STAND-OFF ALSO HOLE CRACKED. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.SDR 2002UALA00803Floorbeam · corrodedCABIN FLOORBEAM 365 EXCESSIVE MATERIAL LOSS FROM CORROSION REMOVAL. MAJOR REPAIR ACCOMPLISHED. INSTALLED UNDER FLANGE STRAP.SDR 2002UALA00223Crease Beam · corrodedCABIN CREASE BEAM BODY STATION 758 RBL 65 HAS EXCESSIVE MATERIAL LOSS AT FASTENER HOLE. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2002UALA00222Frame · dentedAFT PIT, STATION 1420, ABOVE STRINGER 25L, FRAME DENTED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FRAME DOUBLER REPAIR ACCOMPLISHED.SDR 2002UALA00225Crease Beam · corrodedCREASE BEAM BODY STATION 740 RBL 65 CORRODED. MAJOR REPAIR ACCOMPLISHED.INSTALLED DOUBLER REPAIRSDR 2002UALA00224Door · damagedLEFT HAND APU DOOR HAS DAMAGE 38" FROM AFT END 3" FROM LOWER END RIVET IS PUSHING METAL AWAY FROM BUCKTAIL. MAJOR REPAIR ACCOMPLISHED. FLUSH REPAIR INSTALLED.SDR 2002UALA00208Crease Beam · corrodedCABIN CREASE BEAM INNER CHORD BODY STATION 740 TO BODY STATION 757 CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM INNER CHORD.SDR 2002UALA00206Plate · corrodedAFT CABIN DECK PLATE AT STATION 1680 AND RBL 25 CORRODED. MAJOR REPAIR ACCOMPLISHED. DECK PLATE REPAIR DOUBLER INSTALLED.SDR 2002UALA00205Frame · dentedAFT PIT FRAME FLANGE DENT STATION 1440 AT STRINGER 26L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE AND INSTALLED DOUBLER.SDR 2002UALA00216SkinFUSELAGE SKIN BLIND FASTENER INSTALLED STA. 333, STRINGER 2L. MAJOR REPAIR ACCOMPLISHED. INSTALLED SOLID FASTENER.SDR 2002UALA00212SkinFUSELAGE BLIND FASTENER STATION 310 JUST BELOW STRINGER 2L REQUIRES PERMANENT REPAIR. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPLACED FASTENER.SDR 2002UALA00211Skin · damagedEXTERNAL FUSELAGE SKIN STATION 359, STRINGER 3R, REQUIRED PERMANENT REPAIR. STRINGER 3R DAMAGED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPAIRED FUSELAGE SKIN AND STRINGER 3R WITH DOUBLERS.SDR 2002UALA00204Intercostal · corrodedCABIN FLOOR INTERCOSTAL AT STATION 332 RBL 25" TO 39" STRINGER 1 7R CORRODED ON UPPER SURFACE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW INTERCOSTAL U-CHANNEL.SDR 2002UALA00203Intercostal · corrodedCABIN FLOOR INTERCOSTAL AT STATION 332 RBL 4" TO 22" CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW U-CHANNEL.SDR 2002UALA00200Actuator · failedLEADING EDGE SLAT DISAGREE MESSAGE DISPLAYED. THE NUMBER 6 LEADING EDGE SLAT ROTARY ACTUATOR FAILED AND CAUSED SOME BINDING IN THE SLAT. THE BINDING WAS DETECTED BY THE FLAP/SLAT ELECTRONIC UNIT WHICH SUBSEQUENTLY SHUT DOWN THE SYSTEM AS FAILURE PROTECTION.
Back to Boeing 757-222