Boeing 757-223
Service difficulty reports · 8,750
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA961700Floorbeam · corrodedAFW - FOUND FLOOR BEAM AT STATION 324 HAS CORROSION BEYOND SRM LIMITS. ALODINED ALL BLENDED AREAS. FABRICATE STRAPS FROM .050 301.5 HARD STAINLESS STEEL. APPLY TWO COATS PRIMER TO STRAPS AND BEAM FILL BLEND AREA WITH AMS 5092. INSTALL STRAP WITH BACB30NN6 SDR AALA9641Floor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION REMOVAL MATERIAL, REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIRED PER MRB 757-1000. (M)SDR AALA961663Sill · corrodedAFW - AFT CARGO DOOR SURROUND STRUCTURE LOWER SILL HAD CORROSION BLEND BEYOND SRM LIMITS. REPAIRED PER MRB 757-999. (M)SDR AALA961659Floor Beam · corrodedAFW - FLOOR BEAM HAD 2 AREAS OF CORROSION BLENDED BEYOND SRM LIMITS. REPAIRED PER MRB 757-998. (M)SDR AALA961656Floor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION REMOVAL, MATERIAL REMAINING IS BEYOND ALLOWABLE SRM LIMITS. REPAIRED PER MRB 757-997. (M)SDR AALA961652Floor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION REMOVAL, MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIRED PER MRB 757-996. (M)SDR AALA961648Angle · corrodedAFW - ANGLE HAS CORROSION REMOVAL ON UPPER SURFACE, MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-995. (M)SDR AALA961644Support · corrodedAFW - FLOOR SUPPORTS IN SECTION 41 HAVE CORROSION REMOVAL, MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIRED PER MRB 757-994. (M)SDR AALA961544Floor Beam · corrodedAFW - FLOOR BEAM AT STATION 377 HAS CORROSION, REMOVAL ON UPPER SURFACE MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 980. (M)SDR AALA961543Floor Beam · damagedAFW - FLOOR BEAM AT STATION 365 HAS DRILL MARK BLENDOUT, MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIR PER MRB 757-981. (M)SDR AALA961542Pan · gougedAFW - R-4 DOOR HANDLE PAN HAS GOUGE BEYOND SRM LIMITS. GOUGE WAS BLENDED. REPAIRED PER MRB 757-983. (M)SDR AALA961541Frame · corrodedAFW - FUSELAGE FRAME AT STATION 1480 HAS CORROSION REMOVED, REMAINING MATERIAL IS BEYOND ALLOWABLE SRM LIMITS. REPAIR PER MRB 757-986. (M)SDR AALA961540Intercostal · corrodedAFW - INTERCOSTAL BETWEEN STATION 395 AND 418 HAS CORROSION REMOVAL, REMAINING MATERIAL IS BEYOND ALLOWABLE SRM LIMITS. REPAIR PER MRB 757-979. (M)SDR AALA961539Floor Beam · corrodedAFW - FLOOR BEAM AT STATION 1640 HAS CORROSION REMOVAL, REMAINING MATERIAL IS BEYOND SRM ALLOWABLE LIMITS. REPAIR PER MRB 757-982. (M)SDR AALA961507Squib Cartridge · defectiveGYE - DURING OVERNIGHT CHECK, LEFT AND RIGHT SYSTEM SQUIB TEST FOR OVERWING EMERGENCY EVACUATION SLIDES FAILED TO ILLUMINATE. AIRCRAFT MAINTENANCE FERRY GYE. REPLACED LEFT AND RIGHT OVERWING EMERGENCY EVACUATION SLIDE SQUIB CARTRIDGES. SYSTEM GROUND CHECKEDSDR AALA961527Frame · damagedAFW - LEFT AILERON LOWER CONDUCTIVE FRAME HAS SMALL BURN HOLE FROM STATIC DISCHARGE. REPAIRED PER MRB 757-984. (M)SDR AALA961525Pan · corrodedAFW - DOOR PAN AFTER BLENDING CORROSION, REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-977. (M)SDR AALA961523Pan · gougedAFW - AFTER BLENDING GOUGE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-978. (M)SDR AALA961522Pan · gougedAFW - AFTER BLENDING GOUGE, REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-976. (M)SDR AALA961521Skin · damagedAFW - REPAIR USED FASTENERS BACR15CE4D FOR DAMAGED SKIN. REPAIRED PER MRB 757-990. (M)SDR AALA961492Connector · looseDFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY FLOOR LIGHTS BY AFT RT LAVATORY INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTOR BY AFT RT LAVATORY. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA961476Handle Pan · gougedAFW - FOUND R-4 DOOR HANDLE PAN HAS SMALL GOUGE. REF MRB 757-971. REFINISH THE BLEND OUT PER REF C SRM SECTION. (M)SDR AALA961475Floor · corrodedAFW - FOUND FLOOR AT STATION 405 RBL 12 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIRED PER MRB 757-967. (M)SDR AALA961474Sill · corrodedAFW - FOUND AFT CARGO CUT OUT LOWER SILL INNER CHORD HAS CORROSION BLENDED BEYOND SRM LIMITS. REPAIRED PER MRB 757-965. (M)SDR AALA961473Frame · gougedAFW - FOUND FRAME AT STATION 1340 BETWEEN STRINGER 25L AND STRINGER 26L HAD SMALL GOUGE BLENDED BEYOND SRM LIMITS. REPAIRED PER MRB 757-964. (M)SDR AALA961472Frame · crackedAFW - FOUND FRAME AT STATION 780 NEAR STRINGER 24L HAD A SMALL CRACK INBOARD FLANGE. REPAIRED PER MRB 757-963. (M)SDR AALA961471Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 377 LBL 48 HAD CORROSION REMOVED BEYOND SRM LIMITS. REPAIRED PER MRB 757-962. (M)SDR AALA961470Angle · corrodedAFW - FOUND FLOOR STRUCTURE ANGLE AT L-1 DOOR STATION 374 LBL 63 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIRED PER MRB 757-961. (M)SDR AALA961469Floor · corrodedAFW - FOUND FLOOR AT STATION 405, RBL 59, HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIRED PER MRB 757-960. (M)SDR AALA961468Floor Beam · corrodedAFW - FOUND FLOOR BEAM STATION 1640 RBL 30 HAD CORROSION REMOVED BEYOND SRM LIMITS. REPAIRED PER MRB 757-958. (M)SDR AALA961467Floor · corrodedAFW - FOUND FLOOR AT STATION 405, RBL 12 HAD CORROSION BLENDED BEYOND LIMITS. REPAIRED PER MRB 757-968. (M)SDR AALA961448Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT 1640 HAS CORROSION. PER MRB 757-966. (M)SDR AALA961435Handle Pan · gougedAFW - FOUND R-4 DOOR HANDLE PAN HAD SMALL GOUGE BLENEDD BEYOND SRM LIMITS. PER MRB 757-959, BLEND OUT AND REFINISHED PER SRM. (M)SDR AALA961434Skin · damagedAFW - LEFT AND RIGHT NR 3 STABILIZER UPPER SKIN PANELS HAVE SEVERAL DENTS, HAIL DAMAGE. PER MRG 757-957. REINSPECT EVER C-CHECK. (M)SDR AALA961407Door Pan · gougedAFW - AFTER BLENDING GOUGE IN DOOR PAN REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-941. (M)SDR AALA961406Floor Beam · corrodedAFW - AFTER REMOVING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-942. (M)SDR AALA961405Floor · corrodedAFW - AFTER BLENDING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-943. (M)SDR AALA961404Floor · corrodedAFW - AFTER BLENDING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-945. (M)SDR AALA961403Floor Beam · corrodedAFW - AFTER BLENDING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-944. (M)SDR AALA961402Intercostal · corrodedAFW - AFTER BLENDING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757948. (M)SDR AALA961401Handle Pan · gougedAFW - AFTER BLENDING GOUGE ON L-4 DOOR HANDLE PAN, REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-950. (M)SDR AALA961400Hinge Rib · corrodedAFW - FOUND LEFT WING AILERON ATTACH HINGE RIB WAS BLENDED TO REMOVE CORROSION, REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757952. (M)SDR AALA961399Sill · corrodedAFW - AFTER BLENDING CORROSION AT AFT CARGO DOOR CUT OUT LOWER SILL, INNER CHORD, MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-953. (M)SDR AALA961398Floor Beam · corrodedAFW - FOUND SEVERAL AREAS OF CORROSION BLENDED BEYOND SRM LIMITS ON FLOOR BEAM AT STATION 1640. PER MRB 757-954. (M)SDR AALA961361Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 1640 HAS CORROSION REMOVED ON UPPER SURFACES, PER MRB 757-951. (M)SDR AALA961347Door Pan · gougedAFW - FOUND GOUGE AT DOOR PAN IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-935. (M)SDR AALA961346Frame · corrodedAFW - FOUND AFTER REMOVING CORROSION FROM FRAME THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-934. (M)SDR AALA961345Frame · corrodedAFW - AFTER REMOVING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-933. (M)SDR AALA961344Rib · corrodedAFW - FOUND AFTER REMOVING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-932. (M)SDR AALA961343Floor Beam · corrodedAFW - AFTER REMOVING CORROSION, THE MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-931. (M)
Back to Boeing 757-223