Boeing 757-223
Service difficulty reports · 8,750
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA961342Floor · corrodedAFW - FOUND AFTER REMOVING CORROSION, THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-930. (M)SDR AALA961340Floor · corrodedAFW - AFTER REMOVING CORROSION, FOUND REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-929. (M)SDR AALA961338Floor Beam · corrodedAFW - AFTER REMOVING CORROSION, FOUND THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-928. (M)SDR AALA961336Floor Beam · corrodedAFW - FOUND AFTER BLENDING CORROSION, REMAINING METAL BEYOND SRM LIMITS. REPAIRED PER MRB 757-926. (M)SDR AALA961334Floor Beam · corrodedAFW - FOUND AFTER REMOVING CORROSION, REMAINING METAL THICKNESS IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-927. (M)SDR AALA961325Connector · looseSFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY PAX SEAT ROW 18F INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTOR BY PAX SEAT ROW 18F. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961308Connector · looseMIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 9 THROUGH 16 INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTOR BY PAX SEAT ROW 9. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961307Connector · looseMIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY PAX SEAT 3E INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTOR BY PAX SEAT 3E. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961298Skin · corrodedAFW - FOUND FUSELAGE SKIN HAS BLEND OUT STATION 440 BELOW STRINGER 21L. PER MRB 757-925. (M)SDR AALA961277Structure · corrodedAFW - AFTER REMOVING CORROSION, FOUND REMAINING METAL IS BEYOND SRM LIMITS. REPAIR PER MRB 757-913. (M)SDR AALA961276Floor Beam · corrodedAFW - AFTER REMOVING CORROSION, REMAINING METAL IS BEYOND SRM LIMITS ON FLOOR BEAM. REPAIR PER MRB 757-914. (M)SDR AALA961275Floor Beam · corrodedAFW - BLENDED CORROSION, REMAINING METAL IS BEYOND SRM LIMITS ON FLOOR BEAM. REPAIR PER MRB 757-915. (M)SDR AALA961274Rib · corrodedAFW - AFTER REMOVING CORROSION, FOUND REMAINING METAL BEYOND SRM LIMITS ON RIB. REPAIR PER MRB 757-916. (M)SDR AALA961273Blkhd Stiffener · corrodedAFW - FOUND BLENDED CORROSION BEYOND SRM LIMITS ON BULKHEAD STIFFENER. REPAIR PER MRB 757-917. (M)SDR AALA961272Sill · corrodedAFW - AFTER REMOVING CORROSION, FOUND REMAINING MATERIAL BEYOND SRM LIMITS ON LOWER L2 DOOR SILL. REPAIR PER MRB 757-919. (M)SDR AALA961271Door Pan · gougedAFW - FOUND L4 DOOR PAN HAS GOUGE BEYOND SRM LIMITS. REPAIR PER MRB 757-921. (M)SDR AALA961270Floor Beam · gougedAFW - FOUND BLENDED GOUGE ON FLOOR BEAM IS BEYOND SRM LIMITS. (M)SDR AALA961253Skin · gougedAFW - FOUND FUSELAGE SKIN AT L-1 DOOR CUTOUT HAD GOUGE BLENDED BEYOND SRM LIMITS, PER MRB 757-933. (M)SDR AALA961243Light · inoperativeDFW - DURING OVERNIGHT CHECK, FOUND THE RIGHT AFT OVER WATER EMERGENCY EXIT IDENTIFIER INOPERATIVE. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961238Light · inoperativeDFW - DURING OVERNIGHT CHECK, FOUND THE FORWARD COACH SECTION EMERGENCY EXIT FLOOR PATH EXIT PLACARD LIGHT INOPERATIVE. REPLACED EMERGENCY LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (X)SDR AALA961236Actuator · defectiveDFW - UPON GEAR RETRACTION, THE AMBER GEAR LIGHT REMAINED ON AND RECIEVED AND EICAS GEAR DISAGREE MESSAGE. RETURNED TO NORMAL AT 235 KNOTS DURING DESCENT. RETURNED AND LANDED DFW WITHOUT INCIDENT BUT OVERWEIGHT. REPLACED LEFT MAIN GEAR DOOR ACTUATOR. ACCOMSDR AALA961235Sensor · out of adjustDFW - FLT 2303 - UPON GEAR RETRACTION, THE AMBER GEAR LIGHT REMAINED ON AND RECEIVED AN EICAS GEAR DISAGREE MESSAGE. REMAINED ON FOR ABOUT AN HOUR AND 40 MINUTES THEN EXTINGUISHED. LANDED DFW WITHOUT INCIDENT. ADJUSTED LEFT MLG UPLOCK SENSORS. SYSTEM GROUNSDR AALA961226Light · inoperativeDFW - DURING OVERNIGHT CHECK, FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTS IN FIRST CLASS DISLODGED. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AND BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961225Connector · defectiveSFO - DURING OVERNIGHT, MAINTENANCE FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTS IN THE FORWARD CABIN INTERMITTENT. REPLACED CONNECTOR AT RIGHT SIDE FIRST CLASS SEAT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961221Connectors · looseBOS - DURING OVERNIGHT CHECK, FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTING FROM LAST ROW FIRST CLASS CABIN TO OVERWING EXIT, L2 DOOR EMERGENCY EXIT SIGN, R2 DOOR EMERGENCY EXIT SIGN INOPERATIVE. RESEATED CONNECTIONS AT MID GALLEY FLOOR AND RIGHT FORWARD OVERWSDR AALA961216Bushing · wornAFW - INSPECT RIGHT MLG BUSHING FOR MIGRATION. INSPECTION PER MRB 757-900. (M)SDR AALA961215Floor Beam · corrodedAFW - FOUND AFTER CORROSION REMOVAL, BEAM THICKNESS LESS THAN SRM LIMITS. REPAIR PER MRB 757-901. (M)SDR AALA961214Deck Plate · corrodedAFW - AFTER CORROSION REMOVAL, REMAINING THICKNESS BEYOND SRM LIMITS. REPAIR PER MRB 757-902. (M)SDR AALA961213Floor Structure · corrodedAFW - AFTER REMOVING CORROSION, REMAINING THICKNESS BEYOND SRM LIMITS. REPAIR PER MRB 757-903. (M)SDR AALA961212Floor Beam · corrodedAFW - AFTER CORROSION REMOVAL, REMAINING THICKNESS IS BEYOND SRM LIMITS. REPAIR PER MRB 757-907. (M)SDR AALA961211Door Pan · gougedAFW - FOUND DOOR HANDLE PAN GOUGED BEYOND SRM LIMITS. REPAIR PER MRB 757 909. (M)SDR AALA961202Air Distr · odorDFW - FLT 458 - AFTER TAKEOFF DFW DURING CLIMB-OUT, FLIGHT ATTENDANT REPORTED HOT SMELL AND SMOKE IN CABIN. AIRCRAFT RETURNED TO DFW AND LANDED WITHOUT INCIDENT. CHECKED CABIN AND CARGO COMPARTMENTS, RECIRCULATION FANS AND EQUIPMENT COOLING FANS WITH NO ODORSDR AALA961165Filter · contaminatedSJO - FLT 0984 - AFTER TAKEOFF SJO DURING CLIMB-OUT. LT ENGINE EEC LIGHT ILLUMINATED FOLLOWED BY AUTOTHROTTLES DISCONNECTING AND SLIGHT ODOR OF SMOKE NOTED IN COCKPIT. THEN THE RT ENGINE EEC LIGHT ILLUMINATED. ACCOMPLISHED SMOKE REMOVAL CHECK LIST AND TURNEDSDR AALA961158Ballast · overheatedMSY - FLT 1894 - EN ROUTE DFW/SJU DURING CRUISE, SMOKE NOTED IN CABIN BY L1 DOOR. AIRCRAFT DIVERTED TO MSY AND LANDED OVERWEIGHT WITHOUT INCIDENT. REMOVED FORWARD ENTRYWAY CEILING PANELS AND CHECKED LIGHT BALLASTS. PLACARDED TWO FLUORESCENT LIGHTS IN FORWARDSDR AALA961152Skin · scratchedAFW - FOUND SCRATCH IN SKIN AFT FUSELAGE APPROX STATION 1580, STRINGER 27R. (M)SDR AALA961151Rib · drill marksAFW - FOUND VERTICAL STABILIZER RIB AT STATION 206 HAS DRILL MARKS. (M)SDR AALA961150Deck Plate · corrodedAFW - DECK PLATE WITH CORROSION REMOVED. REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIR PER MRB 757-889. TST: 15,172 HOURS. CYCLES: 5,361. (X)SDR AALA961149Door · damagedAFW - DOOR EDGE DAMAGE AFT EDGE AT BOTTOM OF DOOR. REPAIR PER MRB 96C039. TST: 15,172 HOURS. CYCLES: 5,361. (X)SDR AALA961148Support · corrodedAFW - GALLEY SUPPORTS WITH CORROSION REMOVED, MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-892. TST: 15,172 HOURS. CYCLES: 5,361. (X)SDR AALA961147Rib · corrodedAFW - AILERON SUPPORT RIB WITH CORROSION REMOVED. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-894. TST: 15,172 HOURS. CYCLES: 5,361. (X)SDR AALA961146Floor Beam · corrodedAFW - FLOOR BEAM WITH CORROSION REMOVED. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-890. TST: 15,172 HOURS. CYCLES: 5,361. (X)SDR AALA961127Skin · scratchedAFW - FOUND SKIN SCRATCH APPROX 6 INCHES LONG AND .004 INCH DEEP. SCRATCH IS THROUGH 4 FASTENER HEADS STATION 1701, STR 29L. FASTENERS HAVE BEEN REPLACED. REPLACED AFFECTED FASTENERS CHECK BLENDED AREA USING DYE CHECK AND EDDY CURRENT TO ENSURE NO CRACKS EXSDR AALA961119Light · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY FORWARD GALLEY INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT STRIP BY FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961104Connector · looseSFO - DURING OVERNIGHT CHECK, EMERGENCY LIGHTS AT DOOR 2R AND SECOND RIGHT OVERWING DOOR INOPERATIVE. RESECURED LOOSE EMERGENCY LIGHT CONNECTORS AT DOOR 2R AND AT SECOND RIGHT OVERWING DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961070Sill · corrodedAFW - INNER CHORD HAS CORROSION REMOVED, MATERIAL REMAINING IS BEYOND SRM LIMITS PER MRB 757-887. TST: 15,185 HOURS. CYCLES: 5,323. (X)SDR AALA961362Floor Beam · gougedAFW - FOUND FLOOR BEAM WEB AT STATION 1640 AND RBL 24-75 HAS GOUGE, PER SRM 757-949. (M)SDR AALA961071Deck Plate · corrodedAFW - DECK PLATE HAS CORROSION BLENDED BEYOND SRM LIMITS IN VARIOUS LOCATIONS PER MRB 757-880. TST: 15,185 HOURS. CYCLES: 5,323. (X)SDR AALA961069Stub Frame · gougedAFW - STUB FRAME INSTALLATION, LT FORWARD NR 1 DOOR, HAD GOUGE BLENDED BEYOND 10 PERCENT OF THICKNESS PER MRB 883. TST: 15,185 HOURS. CYCLES: 5,323. (X)SDR AALA961015Connector · brokenJFK - DURING OVERNIGHT CHECK, FOUND EMERGENCY FLOOR LIGHTS AT MID-SECTION OF MAIN CABIN INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTOR AT MID-SECTION OF MAIN CABIN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA961000Skin · gougedAFW - FOUND FUSELAGE SKIN AT STATION 376 AND STRINGER 20R HAS GOUGE BLENDED BEYOND SRM. DYE CHECKED, FOUND NO CRACK, BLENDED GOUGE PER SRM 53-00-01-1. DIGITAL THICKNESS PARENT .080 PERFORMED EDDY CURRENT INSPECTION, NO CRACKS NOTED. (M)
Back to Boeing 757-223