Boeing 757-223
Service difficulty reports · 8,750
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA970095Module · defectiveBWI - FLT 600 - DURING APPROACH TO BWI WHEN LANDING GEAR EXTENDED, LEFT MAIN LANDING GEAR GREEN LIGHT FAILED TO ILLUMINATE. RECYCLED LANDING GEAR WITH SAME RE SULTS. ACCOMPLISHED ABNORMAL PROCEDURE AND AIRCRAFT LANDED BWI WITHOUT INCIDENT. REPLACED LANDING SDR AALA970128Chord · corrodedAFW - AFT CARGO DOOR CUTOUT LOWER CHORD HAD CORROSION BLENDED ON THE VERTICAL LEG OUTBOARD SIDE BEYOND SRM LIMITS. REPAIR PER MRB 757-1052. (M)SDR AALA970087Bleed Valve · defectiveORD - FLT T2353 - LATE IN THE TAKEOFF ROLL AT ORD, RT ENGINE HIGH STAGE LIGHT AND EICAS MESSAGE CAME ON FOLLOWED BY HOT ODOR NOTED IN COCKPIT. AIRCRAFT RETURNED TO ORD AND LANDED WITHOUT INCIDENT. REPLACED RT HIGH STAGE VALVE. ACCOMPLISHED LEAK CHECK WITH NSDR AALA970127Pan · gougedAFW - R-4 DOOR PAN HANDLE PAN HAS GOUGE BEYOND SRM LIMITS, REF E58 1814487. REPAIRED PER MRB NR 757-1051. (M)SDR AALA970129Floorbeam · corrodedAFW - FOUND FLOORBEAM AT STATION 1640 RBL 57 AND LBL 19.5 HAD CORROSION BLEND BEYOND SRM LIMITS ES8'S 1814655 AND 1814654. REPAIRED PER MRB NR 757-1045, DATED 1/1/97. (M)SDR AALA970125Structure · corrodedAFW - FLOOR STRUCTURE AT STATION 300 RBL 39 HAD CORROSION BLENDED BEYOND SRM LIMITS, REF E58 1814624. REPAIRED PER MRB NR 757-1049. (M)SDR AALA970124Structure · corrodedAFW - FLOOR STRUCTURE AT STATION 405 RBL 59 HAD CORROSION BLENDED BEYOND SRM LIMITS, REF E58 1814605, ITEM NR 1. REPAIRED PER MRB NR 757-1048. (M)SDR AALA970123Floorbeam · corrodedAFW - FLOORBEAM AT STATION 310 RBL 40 HAD CORROSION BLENDED, BEYOND SRM LIMITS REF E58 18146021. REPAIRED PER MRB NR 757-1047. (M)SDR AALA970122Floorbeam · corrodedAFW - FLOORBEAM AT STATION 324 RBL 62 HAS CORROSION BLENDED BEYOND SRM LIMITS E58 1814625. REPAIRED PER MRB NR 757-1046, DATED 01-01-97. (M)SDR AALA970126Pan · gougedAFW - R-1 DOOR HANDLE PAN HAS GOUGE BEYOND SRM LIMITS, REF E58 1814484. REF MRB NR 757-1050. (M)SDR AALA961904Floorbeam · corrodedAFW - FLOOR BEAM AT STATION 1640 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIR PER MRB 757-1036. (M)SDR AALA961903Door Pan · gougedAFW - L-4 DOOR HANDLE PAN HAS GOUGE BEYOND SRM LIMITS. REPAIR PER MRB 757-1040. (M)SDR AALA961902Floor Beam · corrodedAFW - FLOOR BEAM AT STATION 377 RBL 11 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIR PER MRB 757-1035. (M)SDR AALA961901Floor Support · corrodedAFW - FLOOR STRUCTURE AT STATION 403 RBL 59 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIR PER MRB 757-1034. (M)SDR AALA961900Floorbeam · corrodedAFW - FLOORBEAM AT STATION 310 RBL 3 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIR PER MRB 757-1032. (M)SDR AALA961899Floor Support · corrodedAFW - FLOOR STRUCTURE AT STATION 331 RBL 3 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIR PER MRB 757-1031. (M)SDR AALA961898Floor Support · corrodedAFW - FLOOR STRUCTURE AT STATION 408 RBL 57 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIR PER MRB 757-1030. (M)SDR AALA961897Floor Support · corrodedAFW - FOUND FLOOR STRUCTURE AT STATION 357 RBL 62 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIR PER MRB 757-1029. (M)SDR AALA961896Floor Support · corrodedAFW - FLOOR STRUCTURE AT STATION 372 RBL 62 HAD CORROSION BLENDED BEYOND ALLOWABLE SRM LIMITS. REPAIR PER MRB 757-1027. (M)SDR AALA961895Sill · corrodedAFW - AFT CARGO DOOR LOWER SILL INNER CHORD HAD CORROSION BLENDED BEYOND ALLOWABLE SRM LIMITS. REPAIR PER MRB 757-1037. (M)SDR AALA961894Floorbeam · corrodedAFW - FOUND FLOORBEAM AT STATION 365 RBL 61 HAD CORROSION BLENDED BEYOND ALLOWABLE SRM LIMITS. REPAIRED PER MRB 757-1028. (M)SDR AALA961893Skin · wornAFW - FOUND STATION 1862.7 HAS SMALL AREA OF WEAR, BEYOND SRM LIMITS. REPAIR PER MRB 757-1038. (M)SDR AALA961827Slide · looseORD - FLT 1700 - DURING CRUISE L1 DOOR EMERGENCY ESCAPE SLIDE IS LOOSE FROM DOOR AND SLIDE PACKAGE COVER. CAPTAIN DECLARED AN EMERGENCY AND LANDED ORD AND WITHOUT FURTHER INCIDENT. INSPECTED L1 DOOR SLIDE ASSEMBLY AND SECURED SLIDE AND COVER. (M)SDR AALA961790Switch · defectiveDFW - FLT T0600 - EN ROUTE SNA/DFW DURING CRUISE, EMERGENCY EXIT LIGHTS ILLUMINATED SEVERAL TIMES AND THEN EXTINGUISHED. AIRCRAFT PROCEEDED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED AFT CABIN EMERGENCY LIGHT TEST SWITCH. SYSTEM GROUND CHECKED, NORMAL OPESDR AALA961750Indicator · req resetLAX - FLT 649 - DURING DESCENT INTO SNA, FLAP ASYMMETRY WARNING CAME ON AFTER SELECTING 1 DEGREE FLAP. ACCOMPLISHED EMERGENCY CHECKLIST AND LOWERED FLAPS BY ALTERNATE METHOD TO 20 DEGREES. AIRCRAFT DIVERTED TO LAX AND LANDED WITHOUT FURTHER INCIDENT. RESET SDR AALA961751Exhaust Fan · defectiveSJU - FLT T0672 - EN ROUTE STT/MIA DURING CRUISE, CABIN CREW REPORTED ELECTRICAL FUME SMELL IN CABIN. SMOKE DETECTORS IN FORWARD, MID, AND AFT CABIN LAVATORIES SOUNDED. AIRCRAFT DIVERTED TO SJU AND LANDED WITHOUT FURTHER INCIDENT. REPLACED NR 1 AFT EQUIPMENSDR AALA961741Power Supply · looseSFO - DURING OVERNIGHT CHECK, FORWARD EMERGENCY FLOOR LIGHTS REMAINED ON WHEN TURNED OFF. RECONNECTED FORWARD EMERGENCY FLOOR LIGHT POWER SUPPLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961798Floor Beam · gougedAFW - FLOOR BEAM AT STA 412 TO STA 419 AT RBL 45 HAS GOUGE BLENDED. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIR PER MRB 757-1025. TST: 15,026.39 HOURS. CYCLES, 5,412. (X)SDR AALA961726Fan · defectiveMIA - FLT 2142 - EN ROUTE CCS/MIA - DURING CRUISE, FUMES NOTED COMING FROM COCKPIT INSTRUMENT PANEL. AIRCRAFT PROCEEDED TO MIA AND LANDED WITHOUT INCIDENT. REPLACED NR 1 EQUIPMENT SUPPLY FAN AND FILTER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961802Skin · corrodedAFW - CORROSION BLENDED FROM CROWN SKIN AT 2 AFT MOUNT HOLES FOR THE ADF ANTENNA. MATERIAL REMAINING IS BEYOND ALLOWABLE SRM LIMITS. REPAIR PER MRB 1022. TST: 15,026.39 HOURS. CYCLES, 5,412. (X)SDR AALA961801Sill · corrodedAFW - LOWER SILL INNER CHORD HAS CORROSION REMOVAL ON UPPER AND LOWER SURFACES. MATERIAL REMAINING IS BEYOND ALLOWABLE SRM LIMITS. REPAIR PER MRB 757-1023. TST: 15,026.39 HOURS. CYCLES, 5,412. (X)SDR AALA961807Floorbeam · corrodedAFW - FLOORBEAM AT STATION 365 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND ALLOWABLE SRM LIMITS. REPAIRED PER MRB 757-1016. (M)SDR AALA961806Floor Support · corrodedAFW - FLOOR SUPPORT STRUCTURE HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REF E58 NR 1830913. ALODINE ALL BLENDED AREAS. FABRICATE STRAPS USING .050 301.5 HARD STAINLESS STEEL. APPLY 2 COATS PRIMER TO STRAP ASDR AALA961805Floorbeam · corrodedAFW - FOUND FLOORBEAM AT STATION 345 HAS GOUGE/CORROSION REMOVED ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIRED PER MRB 757-1024. (M)SDR AALA961804Skin · wornAFW - FOUND FUSELAGE SKIN AT STATION 1862.7 (LT) LOWER HAS WEAR FROM HORIZONTAL STAB SEAL. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-1013. (M)SDR AALA961803Floor Beam · corrodedAFW - FLOOR BEAM AT STA 310 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-1019. TST: 15,026.39 HOURS. CYCLES, 5,412. (X)SDR AALA961799Floor Beam · corrodedAFW - FLOOR BEAM AT STA 3877 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-1014. TST: 15,056.39 HOURS. CYCLES, 5,412. (X)SDR AALA961796Frame · corrodedAFW - FUSELAGE FRAME AT 377.7 HAS CORROSION REMOVAL ON WEB ON FORWARD SIDE. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIR PER MRB 757-1020. TST: 15,026.39 HOURS. CYCLES, 5,412. (X)SDR AALA961793Floor Beam · corrodedAFW - FLOOR BEAM STA 395 HAS CORROSION REMOVAL. ALODINE BLENDED AREA, FABRICATE STRAP USING .050 301 1/2 HARD SS. APPLY 2 COATS PRIMER TO STRAP AND FLOOR BEAM. FILL BLENDED AREA WITH BMS5-92 TYPE 10R3. INSTALL STRAP WET USING BMS5-95 SEALANT USING BACB30NWSDR AALA961792Floor Beam · corrodedAFW - FLOOR BEAM STA 345 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REF E58 AND NR 1830905. ALODINE BLENDED AREA. FABRICATE STRAP USING .050 INCH 301 1/2 HARD SS. APPLY 2 COATS PRIMER TO STRAP AND FLOOR BEAM. FILL ALSDR AALA961795Floor Beam · corrodedAFW - FLOOR BEAM AT STA 1640 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMOVED IS BEYOND SRM ALLOWABLE LIMITS. REF: E58 1830949 AND 1830950. ALODINE ALL BLENDED AREAS. FABRICATE STRAPS USING .050 INCH 301 1/2 HARD SS. APPLY 2 COATS PRIMER TO STRAPSSDR AALA961677Connector · looseSFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 4E THROUGH 6E INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT CONNECTOR BY PAX SEAT ROW 4E. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961634Wire · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR LIGHTING AT AFT CABIN INOPERATIVE. REPAIRED BROKEN EMERGENCY EXIT FLOOR LIGHT WIRE AT AFT CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961707Sill · corrodedAFW - AFT CARGO DOOR LOWER SILL INNER CHORD HAD CORROSION. BLENDED BEYOND SRM LIMITS. BLEND OUT IAW 757 SRM 5-10-00. ALODINE AND APPLY TWO COATS OF PRIMER. FILL BLENDED AREA WITH BMS5-92 TYPE 10R3. APPLY DINOL OVER AREA. REINSTALL SAME TYPE FASTENER AS RESDR AALA961702Pan · gougedAFW - R-4 DOOR HANDLE PAN HAS A SMALL GOUGE. AFTER BLENDING, IS BEYOND SRM LIMITS. REFINISH THE BLEND OUT PER REF 'C', SRM SECTION. TST: 14,753.23 HOURS. CYCLES, 5,396. (X)SDR AALA961706Floor Beam · corrodedAFW - FLOOR BEAM AT STA 324 HAS CORROSION ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. BLEND OUT CORROSION. ALODINE, APPLY TWO COATS PRIMER AND FILL WITH BMS5-92. TST: 14,753.23 HOURS. CYCLES, 5,396. (X)SDR AALA961705Floor Beam · corrodedAFW - FLOOR BEAM AT STA 1640 HAS CORROSION ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. ALODINE ALL BLENDED AREAS. FABRICATE STRAPS FROM .050 INCH 301 1/2 HARD STAINLESS STEEL. APPLY TWO COATS PRIMER TO STRAPS AND FLOOR BEAM. FILLSDR AALA961704Support · corrodedAFW - FLOOR SUPPORT STRUCTURE IN SEC 41 HAS CORROSION. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. BLENDED OUT CORROSION AT ALL LOCATIONS. ALODINED, APPLY TWO COATS PRIMER AND FILL WITH BMS5-92. TST: 14,753.23 HOURS. CYCLES, 5,396. (X)SDR AALA961703Floor Beam · corrodedAFW - FLOOR BEAM AT STA 377 HAS CORROSION. ALODINE BLENDED AREAS, FABRICATE STRAPS .050 INCH 301 1/2 HARD STAINLESS STEEL. APPLY TWO COATS PRIMER TO STRAP AND FLOOR BEAM. FILL BLENDED AREA WITH BMS 5-92. INSTALL STRAP USING BACB 30NW6 HILOCKS. TST: 14,75SDR AALA961701Floorbeam · corrodedAFW - FOUND FLOORBEAM AT STATION 365 HAD 2 AREAS OF CORROSION BEYOND SRM LIMITS. ALODINED ALL BLENDED AREAS. FABRICATE STRAPS USING .050 301.5 HARD STAINLESS STEEL. APPLY 2 COATS PRIMER TO STRAPS AND BEAM. FILL ALL BLEND AREAS WITH BMS5-92. INSTALL STRAPS
Back to Boeing 757-223