Boeing 757-224
Service difficulty reports · 3,824
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757224' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757224' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2016112800978Window · crackedL1 WINDOW SHATTERED IN FLIGHT. WINDOW HEAT CONTROLLER FAULTY. REPLACED WINDOW HEAT CONTROLER REF MM 30-41-00. OPS CHECKED NORMAL. REPLACED NR 1 LT CAPT''S WINDOW IAW AMM 56-11-01-004-001 & EC/RA 56 10-01247 & EA 3040-01164 REV I.SDR CALA2016112500962Battery · dischargedNUMBER 2 EMERGENCY FLASHLIGHT AFT GALLEY RIGHT SIDE BATTERY INOP . INSTALLED NEW BATTERY NUMBER 2 EMERGENCY FLASHLIGHT AFT GALLEY RIGHT SIDE.SDR CALA2016112500959Hydraulic Line · leakingLEFT HYD SYSTEM LOSS. EMERGENCY DECLARED. LEFT HYD SYSTEM LEAKING FROM FLEX LINE FOR TILT ACTUATOR ABOVE RT MAIN LANDING GEAR REPLACED HYD FLEX LINE. BLED AND LEAK CK OK.SDR CALA2016112100952Light · inoperativeSLIDE LIGHT BURNED OUT DURING CRUISE AT DOOR 1R. RELAMPED, CKS OKAY.SDR CALA2016112100951Megaphone · inoperativeFA EMERGENCY HAND HELD MEGAPHONE INOP. REPLACED FA EMERGENCY HAND HELD MEGAPHONE. STOWED IN FIRST CLASS.SDR CALA2016112100946Fan · faultyAFTER LEVELING OFF DURING CLIMB AT FL370 THE AIRCRAFT LOST THE LEFT AC BUSS AND FLIGHT DECK HAD ELECTRICAL ODOR. CREW RETURNED TO FIELD. BUSS RESET ON RETURN TO THE GATE. BPCU BITE SHOWS LEFT GEN POWER SYSTEM FAULT. FOUND AFT EQUIP FAN 2 HARD FAULTED, R&R ASDR CALA2016111800936Connector · looseEMERGENCY LIGHT AT SEAT ROWS 32 AND 34 INOPERATIVE. FOUND CONNECTORS LOOSE, SECURED AND OP CHECKED GOOD.SDR CALA2016111800931Arm · out of rigNR 1 ENG THROTTLE FLT IDLE WAS 2 PERCENT LOWER N1 AND ENG 1 SLOW TO SPOOL ON APPROACH. FOUND NR 1 FFG ROTARY ARM OUT OF RIG. OVER 1 COMPLETE RIG PIN OUT OF ADJUSTMENT. ADJUSTED FFG ROTARY ARM IAW MM 76-11-00. ALSO PERFORMED HIGH POWER RUNS TO CONFIRM FIX AND SDR CALA2016111800926Lens · missingFOUND L2 DOOR EMERGENCY LIGHT LENS COVER OFF. REPLACED THE EMERGENCY SIGN LENS. OPS CHECKED OK.SDR CALA2016111400912Light · inoperativeRT AFT SERVICE DOOR EMERGENCY LIGHT INOP. RELAMPED RIGHT AFT EXTERIOR EMERGENCY LIGHT, OPS CHECKS GOOD.SDR CALA2016111400911Light · inoperativeRT EXTERIOR EMERGENCY LIGHT AT DOOR 2R OR MID DOOR IS INOP. RELAMPED, OPS CK GOOD REF AMM 33-51-06.SDR CALA2016111100882Oven · odorAIR RETURN, F/A AND PILOTS SMELLED ODOR REAR GALLEY. PULLED ALL CB AND REMOVED OVENS ODOR CONTINUES. ALL AFT GALLEY OVENS REPLACED. OVEN 411 - ELECTRICAL ODOR FAN SQUEALS, OVEN 412 - BURNT MATERIAL ON HEATING COIL, OVEN 413 - REPLACED AS PRECAUTION.SDR CALA2016111100876Light · inoperativeLEFT OVERWING FWD EMERGENCY LIGHT INOP. RELAMPED PER AMM 33-51-02, OPS CHECK GOOD.SDR CALA2016111100875Socket · not seatedSLIDE LIGHT DID NOT ILLUMINATE WHEN ARMING. 1R RESEATED LIGHT SOCKET OPS CHECK GOOD.SDR CALA2016110400849Battery Pack · dischargedEMERGENCY EXIT AISLE LIGHTS INOP ROWS 20 THROUGH 30. PER FIM TASK 33-51-815-802- BATTERY PACK REPLACED (POWER SUPPLY ALSO REPLACED AS PRECAUTION PER AMM 33-51-07. EMER LIGHTING OPERATIONALLY CHKD OK.SDR CALA2016103100839Battery Pack · inoperativeEMERGENCY LIGHT AT LEFT SEATS 31 THRU 40 NOT OPERATING. REPLACED THE BATTERY PACK.SDR CALA2016103100838Lamp · inoperativeBULLNOSE EMERGENCY LIGHTS AT SEATS 32D AND 2E NOT OPERATING. REPLACED THE LAMP AND OPS CHECKED GOOD. REPLACED THE LAMP AT SEAT 2 OPS CHECKED GOOD. REPLACED THE LAMP AT SEAT 32 OPS CHECKED GOOD.SDR CALA2016102800828Light · inoperativeRT AFT EXTERIOR EMERGENCY LIGHT INOP. RELAMPED RT AFT EXTERIOR EMERGENCY LIGHT. OPS CHECK GOOD.SDR CALA2016102800826Wire Harness · damagedEXTENSION AND RETRACTION EICAS MESSAGE GEAR DOORS LAMP; GEAR DISAGREE DISPLAYED WITH GEAR HANDLE UP. DOORS LAMP; GEAR AMBER LIGHTS ON. ALL GREEN DOWN LIGHTS OFF GEAR DISAGREE THEN QRH PROCEDURE. NORMAL LANDING BUT NOSE GEAR GREEN LIGHT FAILED TO ILLUM. FOUSDR CALA2016102800827Light · inoperativeEMERGENCY RT AFT SERVICE DOOR INOP. RELAMPED OPS CHECKED NORMAL.SDR CALA2017081402637Floorbeam · corrodedWET AREA FLOORBEAM HAS SURFACE CORROSION AT BS 324, RBL 55-60. INSTALLEDTHE FLOORBEAM UPPER TEE AND STRAPS REPAIR BETWEEN RBL 20 AND RBL 60 IAW SRM 53-10-08, FIG 201.SDR CALA2016101000749Girt Bar · obstructedSLIDE LIGHT ILLUMINATED AT THE L2 DOOR. REMOVED DEBRI FROM GIRT BAR LIGHT, FUNCTIONS NORMAL IAW MM 25-66 -00SDR CALA2016100700732Charger · failedEMERGENCY LIGHTS INOPERATIVE AT SEAT ROWS 31-40 ABC. BATTERY ON CHARGER FOUND LOOSE, CHARGER FAILED. CHARGER REPLACED AS PER AMM 33-51-07. ALL FUNCTION NOW NORMAL.SDR CALA2016100700728Transmitter · malfunctionedTE FLAP ASSYM TE FLAP TE FLAP DISAGREE AFTER TO. LAND WT. 220.0 SOFT TOUCHDOWN PERFORMED BITE ON ALL 3 FSEU''S. ONLY #2 FSEU FAULTED FAULT CODE 322. LT SLAT XMT. PER FIM 27-51-00. INSPECTED WIRING AND REMOVED AND REPLACED LT O/B SLAT TRANSMITTER PER AMM 27-88-SDR CALA2016092700701Floorbeam · corrodedAFT WET AREA FLOORBEAM TOP SURFACE HAS SURFACE CORROSION LBL 1 TO LBL 53 TO BS 1681.8. REPAIRED IAW IAW SRM 53-60-51 REPAIR 2 FIG 201 AND MESSAGE PRO-PRO-16-0005-03B AND RES 2011017-53. INTERIM REPAIR ALSO ACCOMPLISHED IAW ECRA 5320-02737.SDR CALA2016092600693Slide · out of adjustL2 DOOR SLIDE PACK APPEARS TO BE OUT OF ADJUSTMENT. FOUND THE L2 DOOR SLIDE BUSTLE LOOSE. SECURED BUSTLE. ACFT OK TO CONTINUESDR CALA2016092600690Lamp · inoperativeLEFT AFT OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS, OPS CHECKED GOOD IAW AMM 33-51-06.SDR CALA2016092600689Lamp · inoperativeLEFT MID OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS. OPS CHECKED GOOD IAW AMM 33-51-06.SDR CALA2016092200675Frame · dentedFRAME DENTED AT BS 580 STRINGERS 23 - 24L. REPAIRED IAW SRM 53-00-07 FIG 201 REPAIR 5 DETAIL I.SDR CALA2016092200669Frame · dentedFRAME DENTED AT BS 1480, STRINGERS 25-26L. REPAIRED IAW SRM 53-00-07 REPAIR 5 PG 210.SDR CALA2016091900657Unknown · odorAFT OVEN 412 GETTING AN ELECTRICAL ODOR WITH OVEN POWERED OFF. PULLED THE CIRCUIT BREAKER NO CHANGE. OVEN REMOVED AND AREA INSPECTED WITH NO FINDINGS OR ODOR. ALL OVEN CONTROLLER BOX UNPLUGGED AND CIRCUIT BREAKER PULLED AND COLLERED. OTHER GALLEY EQUIPMENT SDR CALA2016091400647Bracket · crackedBIN SUPPORT BRACKET AT LEFT FRAME BS 1580 APPROX BELOW STRINGER 8L HAS CRACK AT INBOARD RIVET. FABRICATED REPAIR AND INSTALLED IAW SRM 53-00-07 REP 1, FIG 202SDR CALA2016090900640Floorbeam · corrodedFWD CABIN FLOORBEAM CORRODED AT BS 365.25 RBL 5. REPAIRED THE FLOORBEAM UPPER TEE IAW ECRA 5310-05536 REPAIR 2.SDR CALA2016091400646Lamp · inoperativeLEFT HALF OF EMERGENCY LIGHTS UNARMED LIGHT INOPERATIVE. REPLACED THE LAMP, OPS NORMAL.SDR CALA2016082400581Warning Light · false activationAUTO SPEED BRAKE LIGHT ILLUMINATED. FOUND AUTOSTOW FAULT AND SPEED BRAKES DO NOT ARM. PERFORMED AUTO STOW SYSTEM GROUND CHECK, OPS CHECKED GOOD. PERFORMED AUTO- SPEEDBRAKE SYSTEM OPERATIONAL TEST, OPS CHECKED GOOD. IAW AMM 27-62-00.SDR CALA2016082400580Switch · failedCONTINUOUS ELECTRICAL ODOR FROM R3 LAVATORY, RETURNED TO DEPARTURE AND FOUND THE RT AFT LAVATORY DOOR LATCH LIGHT SWITCH OVERHEATED AND CAUSING ODOR. REMOVED AND REPLACED THE DOOR SWITCH AND OPS CHECKED GOOD.SDR CALA2016082400569Reservoir · dislodgedSLIDE PACK FELL OFF L2 DOOR. REMOVED AND REPLACED THE SLIDE PACK IAW AMM 25-66-01. REPLACED EMERGENCY POWER RESERVOIR IAW AMM 25-11-30. OK TO CONTINUE.SDR CALA2016082300563Bulb · inoperativeR1 DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. SEATED THE BULB. OPS CHECKED GOOD IAW MM 33-51-06SDR CALA2016081500545Indicator · failedAT 100 FEET AGL DURING DEPARTURE, THE LEFT ALTIMETER FAILED. OFF FLAG IN VIEW UNTIL APPROX 100 FEET. REMOVED AND REPLACED THE LT ADC IAW AMM 34-12-01. REMOVED AND REPLACED CAPTAIN`S ALTIMETER IAW AMM 34-13-01. NO OFF FLAG PRESENT.SDR CALA2016081500531Charger · inoperativeROWS 22 - 30ABC EMERGENCY LIGHTS ARE INOPERATIVE. BATTERY CHARGER AND BATTERY REMOVED AND REPLACED IAW AMM 33-51-0 7. OPS CHECKED OK.SDR CALA2016081200528Lamp · inoperativeEMERGENCY LIGHTS INOPERATIVE AT POSITIONS R1 & R2 DOORS. LT OVERWING, AND AFT DOOR. REPLACED THE LAMPS AND PERFORMED AN OPS CHECK, FOUND NORMAL IAW AMM 33-51-00, AND AMM 33-51-06.SDR CALA2016080900514Hose · failedAT 1000 FEET DURING FINAL, EXPERIENCED A COMLETE LOSS OF LT HYD SYS FLUID AND PSI FOUND DOWNLOCK ACTUATOR FLEX LINE WITH HOLE, REPLACED LINE AND RAN ENGINETO VERIFY CORRECT OPERATION OF ENGINE PUMP, ADP AND PTU. ALL FUNCTIONS NORMAL, NO FURTHER ACTION REQUIRESDR CALA2016080900508Skin · damagedDURING PREFLIGHT, FOUND A DENT AT BS 1500 BELOW STRINGER 22R, FOUND WITHIN LIMITS IAW SRM 53-00-01.SDR CALA2016080300492Control Panel · overheatedSLIGHT MOMENTARY ELECTRICAL ODOR IN COCKPIT. COMPLIED WITH SMOKE INSPECTION, FOUND M10050 P5 OVERHEAD PANEL EXTREAMLY HOT AND WITH A SLIGHT BURNED ODOR. REMOVED AND REPLACED THE PANEL IAW AMM 29-11-00. NO OTHER DEFECTS OR ODORS NOTED.SDR CALA2016080100476Frame · dentedFRAME DENTED AT BS 1400, STRINGERS 25-26L. FOUND OUT OF LIMITS IAW SRM 53-00-07 FIG 101, CUTOUT DAMAGED SECTION OF FRAME. FABRICATED AN ANGLE SECTION REPAIR IAW SRM 53-00-07 REP J FIG 201. TREATED, PRIMES AND TOP COATED DOUBLER REPAIR ON FRAME IAW SRM 53-0SDR CALA2016080100475Frame · damagedFOUND A DENT ON THE FRAME BS 1360 STRINGERS 25-26L OUT OF LIMITS IAW SRM 53-00-07 FIG 101, CUTOUT DAMAGED AREA, FABRICATED A J REPAIR IAW SRM 53-00-07 REP 5 FIG 201. TREATED, PRIMED, TOP COATED DOUBLER AND FRAME AREA IAW AMM 51-21-04, 51-21-14 AND 51-21-15. SDR CALA2016072800459Frame · dentedFRAME DENTED AT BS 600 STRINGER 24-25L. INSTALLED A FRAME REPAIR IAW SRM 53-00-07, FIG 201 REPAIR 5.SDR CALA2016072800458Frame · damagedFRAME DENTED AT BS 680, STRINGERS 23-24R. CUTOUT FRAME DAMAGED SECTION, FABRICATED A REPAIR IAW SRM 53-00-07 REPAIR 5 FIG 201 DETAIL I.SDR CALA2016072800457Flap System · malfunctionedTE FLAP DISAGREE LIGHT DURING APPROACH. EXTENDED VIA ALTERNATE PROCEDURE SUCCESSFULLY TO 20 DEG. EMERGENCY DECLARED. FLAP BITE TEST PERFORMED NO FAULTS, FLAP CYCLED SEVERAL TIMES NO FAULTS, SUSPECT INTERMITTENT .SDR CALA2016072500447Frame · crackedVISUAL CRACK INDICATION ON BS 1580 FRAME AT OVERHEAD BIN RAIL ATTACH BRACKET BETWEEN STRINGERS 8 AND 9L. CUTOUT DAMAGED SECTION OF FRAME, TRIMMED OUT, FABRICATED A REPAIR IAW SRM 53-00-07 REP 1 FIG 202 HEAT TREATED IAW 5602, TREATED AND PRIMED REPAIR AND
Back to Boeing 757-224