Boeing 757-224
Service difficulty reports · 3,824
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757224' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757224' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017032400708Actuator · faultyRIGHT OVERWING SLIDE COMPARTMENT DOOR AND CARRIER FAILED TO OPEN DURING SLIDE DEPLOYMENT SYSTEM OPERATIONAL CHECK. REMOVED AND INSTALLED OFF WING ESCAPE SYSTEM ACTUATOR IAW AMM 25-65-05.SDR CALA2017032400694Altimeter · faultySTANDBY ALTIMETER STICKS DURING CLIMB, JUMPS IN INCREMENTS OF 300 TO 400 FEET. REMOVED AND REPLACED STANDBY ALTIMETER IAW AMM 34-13-06.SDR CALA2017032400693Floor Support · brokenMAIN CABIN FLOOR SUPPORT UPPER ATTACH ANGLE IS BROKEN BETWEEN BS 480 AND 500 RBL. 10.5. REPAIRED IAW SRM 51-40-02 PARA 7 FIG 12, AND SRM 51-40-05, PARA 4 FIG 1.SDR CALA2017032100667Charger · faultyAISLE EMERGENCY EXIT LIGHT INOP ROW 7-11. REMOVED AND REPLACED CHARGER AND BATTERY PACK IAW AMM 33-51-07. OPS CHK NML. INSPECTED CHARGER AND BATTERY PACK INSTALL FOR SAFETY AND SECURITY AND OPERATION.SDR CALA2017032100666Warning System · false activationRIGHT SLIDE EICAS CAME ON DURING APP AT 800FT AND WENT BACK OUT AT 200FT. ACCOMPLISHED FIM TASK 52-71-00-815-802.SDR CALA2017032100668Battery Pack · dischargedLT AFT AND RT FWD OVERWING DOOR EXIT IDENTIFIER LIGHTS INOP. REMOVED AND REPLACED BATTERY PACK AT 21 DEF IAW AMM 33-51-07. OPS NML. INSPECTED EMERGENCY LIGHT OPERATION AFTER BATTERY PACK RPL. OPS CHECKS GOOD.SDR CALA2017031700635Contact · dirtyL2 DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. CLEANED THE INTERFACE BETWEEN BULB AND LAMP RECEPTACLE CENTER CONTRACT IAW AMM 20-60-01, PARAGRAPH 2. EMERGENCY LIGHT CHECKED GOOD IAW AMM 33-51-06-962-001-001 D9.SDR CALA2017031700634Charger · failedON AN S2 CHECK, FOUND EMERGENCY LIGHTS OUT AT ROWS 20 TO 30. TROUBLESHOT SYSTEM, FOUND THE BATTERY PACK AND CHARGER TO HAVE FAILED. REPLACED THE BATTERY PACK AND CHARGER M10699 IAW W/D 33-51-14 - OPS CHECKED GOOD.SDR CALA2017031700612Bracket · bentFWD CARGO DOOR AFT LOWER BRACKET BENT. REMOVED AND REPLACED THE BRACKET IAW DRAWING 143N6603-223 AND SRM 51-40-02.SDR CALA2017031700611Bracket · bentFWD CARGO DOOR BRACKET AT LOWER AFT SIDE NEXT TO ROLLER BENT. REMOVED AND REPLACED THE BRACKET IAW DRAWING 140N2791-9 AND SRM 51-40-02.SDR CALA2017031700610Bracket · crackedFWD CARGO DOOR UPPER FWD CORNER BRACKET APPEARS TO BE CRACKED. REMOVED AND REPLACED BRACKET IAW DRAWING 69-53919-6 AND SRM 51-40-02.SDR CALA2017031300592Unknown · odorSMOKE ODOR IN AFT LAV. FA REPORT SMELL LIKE CIGARETTE SMELL COMING FROM RT AFT LAV. INSPECTED LAV FOR ANY SMOKE ODOR NONE FOUND. SMOKE DETECTOR CK'S OK AND TEMP IND UNDER SINK NO DISCOLORATION. A/C OK TO CONTINUESDR CALA2017031300596Threshold · dirtyDOOR-MOUNTED ESCAPE SYSTEM. DOOR 4L EVACUATION SLIDE ARMING LEVER, FAILED TO MOVE, BINDING, AT ENTRY/SERVICE DOOR. CLEANED LOWER DOOR THRESHOLD DEBRIS, DOOR ARMS AND DISARMS NORMALLY.SDR CALA2017031000559Oven · smokeGALLEYS GALLEY G1A - OVEN AT GALLEY DEFECTIVE (DESCRIBE DEFECT) OVEN 204 SMOKING AND SPARKING WHEN IN USE. REPLACED GALLEY OVEN G1A WITH SERVICEABLE UNIT OVEN OPS CKS GOOD.SDR CALA2017030400523Lamp · inoperativeLEFT AFT OVERWING EMERGENCY EXIT EXT SLIDE LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-06. OPS CHECKED NORMAL.SDR CALA2017030400522Light · inoperativeL4 DOOR EXT SLIDE LIGHT INOPERATIVE. REMOVED AND REPLACED THE LIGHT ASSY IAW AMM 33-51-06. OPS CHECKED NORMAL.SDR CALA2017030400520Oven · smokeFIRST CLASS OVEN SMOKES WITH POWER ON. REPLACED THE OVENS 103 AND 205 IN FORWARD GALLEY IAW AMM 25-34-00. OPERATED ALL THREE FORWARD GALLEY OVENS NO SMOKE DETECTED. OPS CHECKED NORMAL.SDR CALA2017022500480Frame · crackedFUSELAGE FRAME HAS SMALL CRACK AT FASTENER HOLE FOR OVERHEAD BIN RAIL ATTACH BRACKET BS 1580 JUST ABOVE STR 9L INSTALLED FUSELAGE FORMED ZEE FRAME REPAIR AT STA 1580 BETWEEN STR 8 AND 9 LT PER REF SRM 53-00-07 FIG 202 REP 1 IS A CATEGORY B REPAIR.SDR CALA2017022400443Wedge · crackedDURING CRUISE PASSENGER REPORTED SEEING A GAP BETWEEN LEFT INBOARD SLAT AND WING. EMERGENCY DECLARED. INSPECTED LEFT INBOARD SLAT AND FOUND NR 5 SLAT TRAILING EDGE WEDGE BULGING WITH APPROX 4 INCH CRACK AT CENTER OF WEDGE. REMOVED AND REPLACED LEFT WING MOST ISDR CALA2017022000434Light · looseDOOR 4R DOOR SLIDE IND ARMED LIGHT DOES NOT ILLUMINATE LIGHT ASSEMBLY LOOSE. SECURED ASSEMBLY. OPS CHECKED GOOD.SDR CALA2017021700381Light · inoperativeL1 DOOR EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED THE EXTERIOR EMERGENCY EXIT LIGHT AT L1 DOOR. OPS CHECKED GOOD.SDR CALA2017020300231Charger · faultyON 2 SERVICE INSPECTION, FOUND 4 OVERWING DOOR EXIT IDENTIFIER EMERGENCY LIGHTS INOPERATIVE. IAW WDM 33-51-22, FOUND M10699 EMERGENCY LIGHTS POWER SUPPLY FAULTY. REPLACED IAW AMM 33-51-07, OPS NORMAL.SDR CALA2017013000207Light · inoperativeEMERGENCY LIGHT UNARMED NEEDS A NEW LIGHT BULB RELAMPED, OPS CHKS GOOD.SDR CALA2017013000199Oven · dirtyFWD GALLEY OVEN BELOW POS205 SMOKES DURING OPERATION. RECOMMEND CLEANING. CLEANED OVEN NO SMOKE NOTED DURING OPERATION AT THIS TIMESDR CALA2017013000198Ballast · faultyELECTRICAL SMELL AFT AIRCRAFT ISOLATED SMELL COMING FROM AREA AT ROW 34 RIGHT OVERHEAD. REPLACED LIGHT BALLAST DIRECTLY ABOVE THAT ROW. INSPECTED CARGO PITS, PSU PANELS. RAN PACKS NO BURNING SMELL NOTICED. AS PER AMM 05-51-58 CREW FILLED OUT FORM 46.6020. ALSOSDR CALA2017013000197Smoke Detector · false activationSMOKE ALARM SOUNDED, NO SMOKE, FIRE EXTINGUISHER DID NOT DISCHARGE. CHECKED AFT LAVATORIES, AFT GALLEY, ALL LIGHTS IN CABIN. ALL CHECKED GOOD .SDR CALA2017013000209Battery Pack · dischargedEMERGENCY LIGHT INOP ABOVE SEATS 26ABC REPLACED POWER SUPPLY-CHARGER, M735, MM TASK 33-51-07-022-020, 33-51-07-862-054. REPLACED BATTERY PACK ON M735, MM TASK 33-51-0 7-902-001. REPLACED LAMP FOR AISLE (BULLNOSE) LIGHT, L1065. TEST OK REF WDM33-51-14, PG 1.SDR CALA2017013000208Power Supply · faultyPER 2SVC, FOUND 2EA EMERGENCY EXIT SIGN LIGHTS INOP AT ROW 20L AND 20R REF WD 33-51-21 AND 22,M10567 AND M10568 LIGHT POWER SUPPLY CONNECTORS ,NO WIRINGS AT POSITION 11 AND 12. REPLACED POWER SUPPLY AT STATION 1248 REF WD33-51-22, PG902 OPS OKSDR CALA2017013000206Battery · dischargedPER 2 SVC FOUND EXTERIOR EMERGENCY LIGHT INOP BY MED 2R, 4R & 4L. RELAMPED 2R AND 4L OPS CK GOOD. DISASSEMBLED 4R FOR TS LIGHT INOP FOUND BATTERY TO BE BAD. REPLACED BATTERY AND TESTED. OPS CHECKS GOOD. REF AMM 33-51-07-902-001 REASSEMBLED 4R EXTERIOR EMERGENCSDR CALA2017012200151Seal · tornEXTREMELY LOUD HIGH PITCH SQUEAL PASSING THROUGH 16000. CONTINUED TO FL190. ON DESCENT STOPPED PASSING THRU FL160. EMERGENCY DECLARED. REPLACED CAPTAIN SLIDING WINDOW SEAL.SDR CALA2017012000135Cusp Web · corrodedCABIN FLOORS STA 560-580 RBL 64 ANGLE SUPPORT SHOWS CORROSION. REMOVED CORROSION AT I/B CREASE BEAM BETWEEN STA 560- STA 580 AND FOUND TO BE WITHIN LIMITS AS PER B757-2 SRM 53-00-01 AND REMOVED AND REPLACED CUSP WEB BETWEEN STA 560 THROUGH STA 580 AND RBL 64" SDR CALA2017012000130Crease Beam · corrodedPASSENGER CABIN CREASE BEAM DEEP CORROSION BETWEEN STA 1240 AND 1280 LT SIDE. INSTALLED CREASE BEAM I/B CHORD SPLICE REPAIR ON MAIN CABIN FROM STA 1230 TO 1290 LT SIDE PER REF SRM 53-00-13 REPAIR 1 DETAIL, FIG 201.SDR CALA2017012000129Compressor · burnedELECTRICAL ODOR AND SMOKE IN AFT CABIN. RT RECIRCULATION FAN INOPERATIVE. PERFORMED SMOKE IN THE CABIN CONDITIONAL INSPECTION IAW AMM TASK 05-51-58-910-801C1, REPLACED POTABLE WATER COMPRESSOR. OPS CHECKED GOOD IAW AMM 38-15-01. REMOVED AND REPLACED RIGHT RESDR CALA2017011300071Tire · failedLOSS OF LT HYD QTY W/ RT MLG INDICATION ON APPROACH. EMERGENCY DECLARED. UPON ARRIVAL AT LAX FOUND NR 7 MAIN TIRE BLOWN. RT MLG W/W RETURN LINE TO DOWNLOCK SEQUENCE VALVE DAMAGED BY BLOWN TIRE. IPC REF 32-32-51-16 ITEM 500. RT MLG WW PRESSURE LINE TO DONLOCK SSDR CALA2017010900044Skin · dentedFUSELAGE DENTED IN AREA FORWARD OF EXISTING REPAIR AT STATION 620 STR 16L REF NR 9006912 MEASURED DENT FOUND TO BE OUT OF LIMITS AS PER SRM 53-00-01 FIG 101 DETAIL III. CUT OUT DAMAGE AREA FAB DOUBLER TO INCORPORATE EXISTING REPAIR IAW SRM 53-00-01 FIG 101 SHESDR CALA2017010900052Light · inoperativeBOTH BULBS BURNED OUT ON EMERGENCY LIGHTS DISARMED LIGHT. RELAMPED OPS CK OK.SDR CALA2017010600013Seat Track · corrodedCABIN SEAT TRACK LBL 24.75 FS 395, HAS LIGHT CORROSION AT CROWN BOTTOM AREA AND GOUGE MARKS AT CROWN LIP AND STUD HOLES EDGES. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-52. REMOVED DAMAGED TRACK LBL 24.75 STA 377 TO STA 440. LOCATED AND DRILLED NEW TRASDR CALA2017010600012Seat Track · corrodedCABIN SEAT TRACK AT LBL 45.5 BETWEEN FS 395 AND 381 HAS CORROSION. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-52. REMOVED DAMAGED SEAT TRACK LBL 45.5 STA 377 TO STA 440. LOCATED AND DRILLED NEW SEAT TRACK IAW SRM 51-40-05 AND INSTALLED IAW SRM 51-40-02SDR CALA2016123001184Threshold · corrodedR2 DOOR THRESHOLD HAS CORROSION AT STA 703, RBL 70. REF. AAR NR 9006708. REMOVED CORROSION AT R2 DOOR THRESHOLD SILL INNER CHORD, FOUND O UT OF LIMITS. REMOVED AND REPLACED CHORD PN 143N8328-53 P.O. NO. 1442041 IAW B757-200 SRM 51-10-02, 53-30-15, 51-40-02 REMSDR CALA2016122701180Lamp · inoperativeEMERGENCY EXIT LIGHT ARMED, BULB ON OVERHEAD PANEL INOPERATIVE. REPLACED THE LAMP. OPS NORMALSDR CALA2016122301163Anti-Ice System · malfunctionedR FWD WINDOW HEAT FAILED ON TAKEOFF. ELEC SMELL NOTED. SWITCH OFF SMELL WENT AWAY. PERFORMED WINDOW INSPECTION R-1 WINDOW FOUND NORMAL. PERFORMED BITE ON WINDOW HEAT CONTROLLER PER FIM TASK 30-41-00 TEST PASSED. PERFORMED WINDOW HEAT TEST PER MM 30-41-00. WINDSDR CALA2016122201155Lamp · inoperativeFOUND R2 & L4 DOOR EXTERIOR EMERGENCY SLIDE LIGHTS OUT. REPLACED THE LAMPS. OPS OK.SDR CALA2016122101146Light · inoperativeDOOR 2 LEFT SLIDE EMERGENCY LIGHT INOP RELAMPED DOOR 2L SLIDE EMERGENCY LIGHT REF AMM 33-51-06 OPS CHK GOOD.SDR CALA2016122101139Light · inoperativeEMERGENCY LIGHT AISLE OVERHEAD AT 30 C NEEDS TO BE RELAMPED. EMERGENCY LIGHT AISLE OVERHEAD AT 30 C RELAMPED AND OPS CHECKED OK.SDR CALA2016121901091Sequence Valve · unserviceableGEAR DISAGREE ON EICAS, HAD TO MANUALLY OVERRIDE TO LOWER NOSE GEAR PER QRH. PERFORMED NORMAL OPERATION CHECK OF MLG NUMEROUS TIMES WITH NO FAULTS OR ABNORMAL OPS, REF AMM 32-32-00. PER TOMC REQUEST REMOVED AND REPLACED NLG OPERATED SEQUENCE VALVE, REF AMM 32SDR CALA2016120901040Seat Track · corrodedMAIN CABIN FLOOR SUPPORT BS 1180 AND LBL 45.50 HAS EVIDENCE OF SURFACE CORROSION REMOVED CORROSION, FOUND BEYOND LIMITS. PERFORMED A REPAIR IAW SRM 53-00 -52, FIG 101, AND 53-00-52. REPAIR 3 FIG 201.SDR CALA2016120501025Light · inoperativeSEAT 36ABC EEL AISLE LIGHT INOP. REPLACED SEAT 36ABC AISLE EEL WHITE LIGHT, REF PATHFINDER EMERGENCY ESCAPE PATH LIGHTING SYSTEM DRAWING BR2013-P-7572CO-5 REV B. OPS CHECK GOOD.SDR CALA2016120501024Battery Pack · dischargedEMERGENCY EXIT LIGHTS OUT FROM ROW 31 AFT OUT. REPLACED M736 EMERGENCY POWER SUPPLY CHARGER AND BATTERY PACK, REF AMM 31-51-07. OPS CHECK OF EMERGENCY ESCAPE LIGHT SYSTEM, INCLUDING ALL SEATS GOOD.SDR CALA2016120501023Light · inoperativeMID LAV EMERGENCY LIGHT INOP RELAMP. OPS CK GOOD.SDR CALA2016112800983Battery Pack · dischargedFOUND EMERGENCY PATH LIGHT FROM SEATS 20- 30 INOP. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AND BATTERY CHARGER IAW AMM 33-51-07. OPS CHECK NORMAL.
Back to Boeing 757-224