SDR IPXA2015062990658Floor Panel · damagedINSPECTION TYPE: C, MCD FLOOR PANEL 242XKF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015062990657Floor Panel · damagedINSPECTION TYPE:C, MCD FLOOR PANEL 241XLF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015062990656Floor Panel · damagedINSPECTION TYPE:C, MCD FLOOR PANEL 241XFF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H. 2.SDR IPXA2015063090676Floor Panel · damagedINSPECTION TYPE :CMCS, FLOOR PANEL 241XMF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015062990650Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 242XLF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015062990648Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 242XDF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015062990647Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 241XBF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015062290403Target · looseLEFT FWD ENTRY DOOR EICAS WITH DOOR CLOSED. FOUND TARGET FOR SENSOR S10094 LOOSE. SECURED TARGET & CHECKED ADJUSTMENT IAW AMM 52-71-00-825-223. OPS CK OK.SDR IPXA2015061990342Sensor · out of positionLEFT FWD ENTRY DOOR LIGHT ILLUMINATED EVEN WHEN DOOR CLOSED. SHIMMED PROXIMITY SENSOR IAW MM 52-71-00-825-223. TESTS OK. DEF CLOSED.SDR IPXA2015062190379Floorboard · delaminatedINSPECTION TYPE:C-11, SUPERNUMERARY AREA FLOORBOARD 211AF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015061790289Battery · dischargedFOUND CAPTAIN`S EVAS LID LOOSE AND BATTERY DEAD. NO TEST. CAPTAIN`S EVAS REMOVED IAW AMM 25-69-00 TESTED NORMALLY.SDR IPXA2015061790268Skin · puncturedSKIN PUNCTURED AT BS 263 TO BS 270.5 5 INCHES BELOW S20L. TEMP REPAIR IAW EO 5330-577934A TEMP REPAIR IAW EO 757-5330-57793-A. ACFT OK FOR SERVICE.SDR IPXA2015070190713Wedge · delaminatedINSPECTION TYPE:C-9, LT WING SLAT NR 2 SLAT OTBD SIDE UPPER T/E WEDGE DELAMINATED. REPAIRED WITH METAL HOT BOND REPAIR IAW SRM 51-70-10 AND REO-G19016, REV B.SDR IPXA2015062590538Floor Panel · delaminatedINSPECTION TYPE: C11, CABIN FLOOR PANEL 231XMF LOWER SURFACE DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9690-H.SDR IPXA2015061590162Container · tornSECOND OBSERVER`S SEAT LIFE VEST BAG IS TORN. R & R THE LIFE VEST IAW MM 25-64-00, & 25-64-51-01.SDR IPXA2015061290093Unknown · odorAFTER TAKEOFF BACKLIGHTING IN ENGINE START PANEL WENT OUT A WHILE LATER SMELLED A CHEMICAL ODOR FOLLOWED BY AN ODOR OF BURNING OR CHANED PAPER. DONNED OXYGEN MASKS AND TROUBLSHOT INDIVIDUAL PACKS TO NO AVAIL. EXAMINED INSPECTED WIRING & SURROUNDING AREAS OFSDR IPXA2015062990642Frame · corrodedINSPECTION TYPE:C9, S1 APU TAILCONE ATTACH FRAME AT BS 1992.8 IS CORRODED. REPLACED FRAME ASSY PN 148N1606-7.SDR IPXA2015062490513Wedge · dentedINSPECTION TYPE: C11, LT WING NR 5 SLAT WEDGE UPPER SURFACE DENTED AT 9 IN FROM INBD EDGE AND 5" FROM T/E. REPAIRED WITH METAL HOT BOND REPAIR IAW SRM 57-43-02-2R, FIG 201 AND 51-70-10, REPAIR 4.SDR IPXA2015061190067Warning Light · false activationEICAS MESSAGE, LT FWD ENTRY DOOR DISPLAYED STEADY AND ENTRY DOOR OPEN LIGHT ON STEADY WITH DOOR CLOSED WHILE TAXI IN TO PARK, CYCLED L1 FWD ENTRY DOOR SEVERAL TIMES INSPECTED DOOR SWITCH COULD NOT DUPLICATE REPORT. DOOR WARNING INDICATIONS NORMAL.SDR IPXA2015061190058Control Box · looseCAPTAIN`S, EVAS SYSTEM BOX LOOSE. REINSTALLED SERVICEABLE CAPTS EVAS UNIT IAW AMM 25-69-00.SDR IPXA2015063090708Skin · corrodedINSPECTION TYPE: C-9, EMPENNAGE APU EXHAUST TAIL CONE EXTERIOR HAS CORROSION AT BS 1992.8 AND 0630 POSITION, LBL6. REPAIRED PANEL WITH METAL HOT BOND REPAIR IAW REO-G19014 AND SRM 51-70-10.SDR IPXA2015062490509Skin · dentedINSPECTION TYPE:C9, LEFT INBD FLAP UPPER SURFACE IS DENTED, CREASED. REPAIRED WITH METAL HOT BOND REPAIR IAW SRM 57-53-01, REPAIR 1 AND 51-70-10, REPAIR 2.SDR IPXA2015062490505Skin · dentedINSPECTION TYPE: C9, LEFT INBD FLAP UPPER SURFACE IS DENTED, CREASED. REPAIRED WITH HOT METAL BOND REPAIR IAW SRM 57-53-01, REPAIR 1 AND 51-70-10, REPAIR 2.SDR IPXA2015062190383Frame · dentedINSPECTION TYPE: C-11, FWD CARGO BAY FRAME AT STA 720, STR 23L IS DENTED. REPAIRED FWD PIT FRAME AT STA 720, STR 23L IAW SRM 53-00-07-2R-5, DETAIL I.SDR IPXA2015062190382Frame · dentedINSPECTION TYPE:C-11, FWD PIT FRAME AT STA 780, STR 23L DENTED. REPAIRED FWD PIT FRAME AT STA 780, STR 23L IAW SRM 53-00-07-2R-5, FIG 201, DETAIL I.SDR IPXA2015060990031Container · tornLIFE VEST IN COMPARTMENT TO RT OF F/O SEAT HAS TORN BAG. R & R LIFE VEST IN RT STORAGE COMPARTMENT OF F/O SEAT REF AMM 25-64-00.SDR IPXA2015060990030Container · tornLEFT SUPERNUMERY SEAT ON AFT WALL HAS LIFE VEST WITH TORN BAG. R & R LT SUPERNUMERY SEAT LIFE VEST REF AMM 25-64-00 EFF SOURCE, REF: IPC 25-64-51-01.SDR IPXA2015061390117Seat Track · corrodedINSPECTION TYPE: C, FLIGHT DECK CAPTAIN`S SEAT TRACK MOUNTING FLANGE HAS LIGHT SURFACE CORROSION. REMOVED SEAT TRACK IAW MM 25-11-01-02-198, NO ALLOWABLE DAMAGE. INSTALLED SEAT TRACK IAW MM 25-11-01-822-078.SDR IPXA2015060689891Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XKF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689890Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XBF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689888Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 251XBF HAS DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689887Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XLF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689885Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252XCF IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689884Floor Panel · brokenINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XBF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689883Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 221XCF IS PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-N.SDR IPXA2015060689882Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XXF HAS TORN INSERTS HOLES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789936Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XRF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789935Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XJF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789934Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789933Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252XQF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789932Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789931Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 251XEF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789930Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XWF HAS EDGE DAMGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789929Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XWF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789928Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XFF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789927Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XAF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789926Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789925Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 251XAF EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789924Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XKF IS DELAMINATED. FABRICATE A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789923Floor Panel · puncturedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XBF IS PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.
Back to Boeing 757-24APF