Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015060789922Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 221XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789921Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XNF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789920Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XQF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789919Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XJF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789918Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XPF HAS EDGE DAMAGE AND PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692.SDR IPXA2015060789917Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK PANEL 242 XFF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789916Floor Panel · crackedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XDF IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789915Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XEF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789914Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 242XGF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789913Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 241XEF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789912Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XUF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060589853Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XXF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060489812Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XCF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060489811Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XLF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060489809Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252XEF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060489808Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-532-9692-H.SDR IPXA2015060489807Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 252XKF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060489806Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060489805Floor Panel · puncturedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XPF IS PUNCTURED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060489804Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 221XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060489803Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XSF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060189663Mount · looseF/O'S EVAS UNIT MOUNTING BRACKET LOOSE FROM ACFT STRUCTURE. REMOVED F/O'S EVAS UNIT AND PLACED IN PFM BOX IAW DMP. INSTALLED EVAS MOUNTING PLATE REF EVAS DWG 6307.SDR IPXA2015061590225Duct · damagedINSPECTION TYPE: C, LT ENGINE OTBD T/R INNER BARREL OUTER SURFACE AFT EDGE SKIN HAS CHIPPED AND BENT. BLENDED, DAMAGE IAW SRM 51-10-02-0G.SDR IPXA2015060789937Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389759Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252 XNF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389768Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 251XCF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692.SDR IPXA2015060389767Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 251XLF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389764Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XCF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389762Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389761Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XVF IS DELAMINATED. FABRICATION A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389760Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XGF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389757Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 251XFF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389756Floor Panel · brokenINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252XCF IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389754Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 252XDF HAS EDGE DAMAGE. FABRICATION A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389770Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XTF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015052989535Floor Panel · puncturedINSPECTION TYPE: C-12, MAIN CABIN FLOOR PANEL 241XFF HAS MULTIPLE DENTS AND A PUNCTURE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060389765Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252XHF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015052789476Skin · dentedINSPECTION TYPE:C-8, LT HORIZONTAL STABILIZER UPPER SKIN WAS DENTED BETWEEN FT AND AUX SPAR, 67" FROM INBD END AND 19" FROM FT SPAR. REPAIRED DAMAGE IAW 51-70-10. REPAIR 4, FIGURE 201 AND 51-70-10-2R.SDR IPXA2015052789466Life Vest · damagedLIFE VEST POUCH TORN AT 1ST OBSERVERS POSITION. R & R 1ST OBSERVER LIFE VEST W/REF TO AMM 25-62-00-0001. PN ON-OFF: P01074-201C/P01074-101, SN ON-OFF: 15040610201/13092160047 EFF SOURCE: 25-62-31-01A.SDR IPXA2015052889504Floorboard · puncturedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 252XFF IS PUNCTURED ON THE UPPER SURFACE. FABRICATED A NEW FLOORBOARD IAW REO B757-5320-9692-H.SDR IPXA2015052389360Hook And Loop · damagedINSPECTION TYPE:PS1, ELT HOOK AND LOOP BELT TORN, UNSERVICEABLE. R & R HOOK AND LOOP STRAP, IAW AMM 25-60-00.SDR IPXA2015053089568Floorboard · crushedINSPECTION TYPE: C8, FLOORBOARD 221XBF CRUSHED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692H.SDR IPXA2015053089571Floorboard · delaminatedINSPECTION TYPE: C8, CABIN FLOORBOARD 252XTF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2015052889503Floorboard · gougedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 221XCF EDGE IS GOUGED. FABRICATED A NEW FLOORBOARD IAW UPS REO B757-5320-9692-H.SDR IPXA2015052889502Floorboard · crushedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XBF EDGE IS CRUSHED. FABRICATED A NEW FLOORBOARD IAW REO B757-5320-9692-HSDR IPXA2015052489393Floorboard · dentedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 241XLF HAS MULTIPLE SURFACE DENTS. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015052489392Floorboard · crackedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 231XHF IS CRACKED, FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015052489391Floorboard · gougedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD CORNER IS GOUGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015052689421Floorboard · brokenINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XCF CORNER IS BROKEN. FABRICATED NEW PANEL IAW B757-5320-9692-H SREO.SDR IPXA2015052689420Floorboard · damagedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD, 241XJF IS DENTED AND HAS A BROKEN CORNER. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.
Back to Boeing 757-24APF