Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015052689419Floorboard · gougedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 231XDF IS GOUGED ON THE UPPER SURFACE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-96-92-H.SDR IPXA2015062590544Door Sill · puncturedINSPECTION TYPE:C, MCD DOOR SILL WEB SKIN HAS A PUNCTURE/CRACK AT THE FWD EDGE OF LATCH PIN FITTING, NR 2 MAIN CARGO DOOR WEB, PN:143N8750-2 HAS BEEN REPAIRED IAW VT MAE EA 757-5331-27-A2177 AND EO B757-5310-57849-A. THIS REPAIR HAS BEEN CLASSIFIED AS A MAJORSDR IPXA2015053089570Floorboard · delaminatedINSPECTION TYPE: C8, CABIN FLOORBOARD 231XMF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2015053089569Floorboard · delaminatedINSPECTION TYPE: C8, FLOORBOARD 231XRF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692H.SDR IPXA2015053089567Floorboard · delaminatedINSPECTION TYPE: C8, CABIN FLOORBOARD 231XPF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2015053089566Floorboard · delaminatedINSPECTION TYPE: C8, CABIN FLOORBOARD 231XLF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW B757-5320-9692-H.SDR IPXA2015053089565Floorboard · delaminatedINSPECTION TYPE: C8, FLOORBOARD 231XYF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2015053089572Floorboard · crackedINSPECTION TYPE: C8, CABIN FLOORBOARD 231XCF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2015060189610Floorboard · puncturedINSPECTION TYPE: C8, MAIN CABIN FLOORBOARD 252XUF PUNCTURED IN SEVERAL AREAS. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015052889501Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015052889500Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 232XYF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015052889499Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 232XMF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015051589114Bulb · inoperativeEMERGENCY LIGHT HAS SIX INOPERATIVE BULBS. REPLACED THE INOPERATIVE BULBS IAW AMM 33-51-01-2.SDR IPXA2015051589112Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XJF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015051589111Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XFF WAS FOUND TO BE DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689871Frame · dentedINSPECTION TYPE: C-8, FWD CARGO BAY BS 680, STR 23R FRAME DENTED. REPAIRED THE FRAME IAW SRM 53-00-07-2R-5, FIGURE 201, SHEET 4, DETAIL I.SDR IPXA2015060689870Frame · dentedINSPECTION TYPE:C-8, FWD CARGO BAY RT BS 740, STR 25R, FRAME DENTED. REPAIRED THE FRAME IAW SRM 53-00-07-2R-5 FIGURE 201, SHEET 8, DETAIL III.SDR IPXA2015060789911Frame · dentedINSPECTION TYPE:C8, FWD CARGO BAY LT SIDE BS 680 FRAME AT 25L DENTED. REPAIRED DENTED FRAME IN FWD CARGO COMPARTMENT BS 680, STR 25L IAW SRM 53-00-07-2R-5, FIG 501, DETAIL III.SDR IPXA2015060789940Skin · crackedINSPECTION TYPE: C12, FWD CARGO DOOR, LOWER EDGE OF EXTERIOR SKIN HAS FILLED DENT. PERFORMED SKIN REPAIR IAW SRM 52-30-01-2R.SDR IPXA2015051489079Container · damaged2 EA COCKPIT LIFE VESTS CONTAINERS DAMAGED INSTALLED 2 EA COCKPIT LIFE VEST IAW MM 25-64-00-001, EFF SOURCE REF 25-64-55-05A.SDR IPXA2015060289708Skin · dentedINSPECTION TYPE: C-8, LT HORIZONTAL STABILIZER LOWER SKIN HAS DENT BETWEEN RIB 3 AND RIB 4, FRONT AND AUX SPAR. REPAIRED WITH METAL HOT BOND REPAIR IAW SRM 51-70-10, REPAIR 2 AND 51-70-10-2R GENERAL.SDR IPXA2015060889948Skin · gougedINSPECTION TYPE: C-8, LEFT WING NR 3 SLAT T/E WEDGE HAS A GOUGE ON LOWER SURFACE AFT END. ACCOMPLISHED METAL HOT BOND REPAIR IAW EO B757-5750-57717-A & REO-G18941, REV A.SDR IPXA2015060889947Skin · dentedINSPECTION TYPE:C-8, RT WING NR 7 SLAT UPPER EXT SURFACE DENTED. ACCOMPLISHED METAL HOT BOND REPAIR IAW EO B757-5750-57716-A & REO-G18942, REV A.SDR IPXA2015060889945Skin · dentedINSPECTION TYPE: C-8, 3 SLAT UPPER SURFACE HAS MULTIPLE DENTS. ACCOMPLISHED METAL HOT BONDED REPAIR IAW EO B757-5750-57717-A & REO-G18941, REV A.SDR IPXA2015050888811Floor Panel · crackedINSPECTION TYPE: C11, MAIN CABIN FLOOR PANEL, 232-XDF IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B7575320-9692-H.SDR IPXA2015050888810Floor Panel · crackedINSPECTION TYPE: C-11, MAIN CABIN FLOOR PANEL 231XEF IS CRACKED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015050888809Floor Panel · crackedINSPECTION TYPE: C-11, MAIN CABIN FLOOR PANEL 232XEF IS CRACKED. FABRICATED AND FLOOR PANEL IAW SREO 5320-9692-4.SDR IPXA2015050888808Floor Panel · crackedINSPECTION TYPE:C-11, MAIN CABIN FLOOR PANEL 232XJF IS CRACKED. FABRICATED NEW FLOOR PANEL IAW B757-5320-9692H.SDR IPXA2015050888805Floor Panel · crackedINSPECTION TYPE: C-11, MAIN CABIN FLOOR PANEL 232XGF IS CRACKED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015050788804Floor Panel · crackedINSPECTION TYPE: C11, MAIN CABIN FLOOR PANEL 231XGF IS CRACKED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9672-H.SDR IPXA2015050588735Floor Panel · crackedINSPECTION TYPE:C-11, MAIN CARGO FLOOR PANEL 231XAF IS CRACKED AND DENTED, FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692.SDR IPXA2015050688745Skin · dentedINSPECTION TYPE:C-11, DENT IN FUSELAGE SKIN APPROXIMATELY STA 1772-1780 AFT OF DOOR 311AL, APPROXIMATELY BETWEEN STR 20 AND 21, BS1772-BS1780. ACCOMPLISHED SKIN REPAIR IAW REO-G18889, REV A AND EO B757-5330-57333-A.SDR IPXA2015050488629Seal · damagedMAIN ENTRY DOOR. AFT MIDDLE SECTION OF SEAL HAS A HOLE IN IT. REPAIRED DAMAGED SECTION OF SEAL REF AMM 52-09-00-308-001.SDR IPXA2015051289015Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 241XAF HAS INSERTS AND EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015051289013Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 242XBF HAS EDGE DAMAGE AND PUNCTURES ON UNDERNEATH SIDE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015051289012Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 242XFF HAS EDGE DAMAGE AND DELAMINATION. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015051289011Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 242XCF HAS EDGE DAMAGE 122-071. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015051289010Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 242XGF HAD DAMAGED INSERTS. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015051289009Floorboard · damagedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 241XGF HAS DAMAGED INSERTS 122-111. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015051289008Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 241XLF HAS DAMAGED INSERT. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015051289007Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 241XCF HAS PUNCTURES ON UNDERNEATH SIDE. 122-051. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015050988860Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 242XFF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2015050888859Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 242XBF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2015050888858Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 242XDF EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2015050888857Floor Panel · damagedINSPECTION TYPE:C, MAIN CARGO DECK FLOOR PANEL 242XCF EDGE DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2015050888856Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 241XDF EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2015050888855Floor Panel · damagedINSPECTION TYPE:C, MAIN CARGO DECK FLOOR PANEL 242XEF. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2015050288557Lens · brokenINSPECTION TYPE:PS-1, EMERGENCY EXIT LIGHT LENS BROKEN AND LENS HOUSING BROKEN. REQ E129652, REPLACED EMERGENCY EXIT HOUSING ASSY IAW 33-51-01-201.SDR IPXA2015050388584Floor Panel · delaminatedINSPECTION TYPE:C-11, MAIN CABIN FLOOR PANEL 242XAF HAS DELAMINATED AND EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA2015050488635Smoke Goggles · damagedSMOKE GOGGLES CRACKED AT SUPER NUMERARY POSITION. R & R SUPER NUMERARY POSITION SMOKE GOGGLES AS REQUIRED.
Back to Boeing 757-24APF