SDR IPXA2015051989271Transition Panel · corrodedINSPECTION TYPE:C, NUMEROUS AREAS OF CORROSION ON AFT PIT RT TRANSITION PANEL UPPER SURFACE AT THE DOWN FITTINGS AND INBD NUTPLATE ROWS BS 1530-1640. 53-141. REMOVED SURFACE CORROSION ON AFT PIT RH TRANSITION PANEL FROM STA 1530-1640 IAW SRM 51-10-02-0G. CHESDR IPXA2015051989270Transition Panel · crackedINSPECTION TYPE: C, AFT CARGO COMPARTMENT LT TRANSITION PANEL SKIN SURFACE AT FS 1420 HAS CRACK, DOT 52-451. REMOVED DAMAGED SECTION OF TRANSTION PANEL AFT SPLICE FS 1440 TO 1430 LT AND AFT CARGO PIT IAW SRM 51-40-02-0G. 2. FABRICATED REPAIR SPLICE ON MAE TRSDR IPXA2015050188538Floor Panel · damagedINSPECTION TYPE:C-11, MAIN CABIN FLOOR PANEL 252XHF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5330-9692-H.SDR IPXA2015050288556Floor Panel · crackedINSPECTION TYPE:C11, MAIN CABIN FLOOR PANEL 231XHF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA2015050388583Floor Panel · damagedINSPECTION TYPE:C-11, MAIN CABIN FLOOR PANEL 251XDF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA2015051489087Keelbeam · corrodedINSPECTION TYPE:C, LT KEEL BEAM ANGLE AFT SPLICE AT APPROXIMATELY BS 1020 CORRODED. R & R LT KEEL BEAM ANGLE AFT SPLICE, PN:144N8140-2, BATCH 0002622686 IAW SRM 51-40-02-0G.SDR IPXA2015051489086Keelbeam · corrodedINSPECTION TYPE:C, KEEL BEAM ANGLE CENTER SPLICE AT APPROXIMATELY BS 950 CORRODED. R & R LT KEEL BEAM ANGLE CENTER SPLICE, PN:144N8140-2, BATCH 0002794587 IAW SRM 51-40-02-0G.SDR IPXA2015051589098Keelbeam · corrodedINSPECTION TYPE: C, LT KEEL BEAM ANGLE CENTER SPLICE AT APPROXIMATELY BS 950 CORRODED. R & R LT KEEL BEAM ANGLE CENTER SPLICE IAW SRM 51-40-02-0G.SDR IPXA2015042688386Skin · dentedFUSELAGE SKIN DENT DAMAGE FS 21A ABOVE STR 21R, REF EO B757-5330-57101-A FOR REPAIR.SDR IPXA2015050188535Floor Panel · crackedINSPECTION TYPE:C-11, MAIN CABIN FLOOR PANEL 232XXF HAS DAMAGE TO THE LOWER SURFACE FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015042188259Floorbeam · corrodedINSPECTION TYPE:C, MAIN CARGO DECK FLOORBEAM, BS 620, LBL 33 HAS CORROSION. ACCOMPLISHED FLOORBEAM REPAIR AT STA 620, LBL 33 IAW 757-200PF SRM 53-00-51-28, REPAIR 6, DETAIL III.SDR IPXA2015050888815Floor Panel · brokenINSPECTION TYPE: C-11, MAIN CABIN FLOORBOARD 232XHF IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015042988474Skin · dentedINSPECTION TYPE:C11, RT HORIZONTAL STABILIZER UPPER SURFACE HAS 2 EA DENTS APPROX FS 210.0939 IN FWD OF FWD SPAR AND FS211.093 12 IN FWD OF THE FWD SPAR. THESE DENTS COMBINED HAVE MORE THAN 1.5 IN DAMAGE IN A 1 SQUARE FT AREA REPAIRED IAW SRM
51-70-10-2R & SDR IPXA2015041888191Light · inoperativeEMERGENCY EXIT EGRESS LIGHT ON FUSELAGE ABOVE LT NOSE GEAR DOOR IS INOPERATIVE. LAMPED & OPS CHECKED EMERGENCY EGRESS LIGHT IAW AMM 33-51-06-962-001-0033. OPS CHECKED GOOD.SDR IPXA2015041688148Floor Panel · damagedINSPECTION TYPE:C, MECHANIC REQUEST MAIN DECK FLOOR PANEL 242XAF, PN144N5361-40 HAS EDGE DAMAGE.1. FABRICATED THE FLOOR PANEL IAW SREO.SDR IPXA2015041688129Link · out of adjustF/O WINDOW DIFFICULT TO UNLATCH, ADJUSTED LINK ARM ON F/O'S SIDE WINDOW IAW AMM 56-11-02-825-001, CLEANED ALL LOCKING CAMS OPERATED WINDOW SEVERAL TIMES, PRESSURIZED ACFT TO 4 PSI. OPS WAS NORMAL REF AMM 56-11-02-715-020.SDR IPXA2015041287985Skin · dentedINSPECTION TYPE:C, FUSELAGE SKIN DENTED BETWEEN FS 263 AND FS 280 BELOW S-20L, LT SIDE FWD OF CREW DOOR, D536379, TRANSFERER FROM LOGPAGE 441143, ITEM 3 REPAIRED IAW REO G18801, REV C AND EO B757-5330-57152-A.SDR IPXA2015041688149Floor Panel · misrepairedINSPECTION TYPE:C, MAINTENANCE REQUEST MAIN DECK FLOOR PANEL 241XCF, PN 144N5361-36 UPPER SURFACE HAS AN IMPROPER REPAIR. FABRICATED THE FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015041588120Floor Panel · delaminatedINSPECTION TYPE:C, MECHANIC REQUEST: CABIN FLOOR PANEL 222XCF DELAMINATED. TRANSFERRED FROM 2015041588116, FABRICATED NEW FLOOR PANEL 222XCF IAW SAMPLE IAW EO 5320-9692-H MATERIAL A402H-48X144 BATCH NR 2664589.SDR IPXA2015041087947Egt Indication · fluctuatesMACHINED RT ENGINE EPR/EGT INDICATION BEGAN TO FLUXUATE. SEVERITY AND FREQUENCY BECAME MORE SEVERE RAPIDLY. ENGINE RETARDED TO IDLE EPR/EGT IND STABILIZED IN NORMAL RANGE. ENGINE NOT SHUTDOWN AND REMAINED IDLE WITH NORMAL IND'S FOR REMAINDER OF FLT. R & R SDR IPXA2015041087946Slat System · malfunctionedIN L/E SLAT DISAGREE BETWEEN 0 AND 1 USED AL IAW QRH, LANDED, FLAPS 20 UNEVENTFUL. T/S DISAGREE REF FIM 27-81-00-815 AND FSEU BITE REF FIM 27-51-00-815 NR 10 ROTARY ACT RESET REF ITEM 3, LP 370926. REVIEWED HISTORY NO PREVIOUS DEFECTS FOR LAST 12 MONTHS. LUBSDR IPXA2015041688147Floor Panel · damagedINSPECTION TYPE:CMCD, FREIGHTER FLOOR PANEL 232XCF HAS EDGE DAMAGED FABRICATED NEW FLOOR PANEL 232XCF IAW SAMPLE IAW EO-B757-5320-9692-H. MATERIAL A402H-48X144, BATCH 2664589.SDR IPXA2015040887860Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 241XGF HAS DAMAGE TO CORE. RECREATED FROM 2015040687754, FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015040687732Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOR PANEL 241XEF HAS DAMAGE TO CORE. FABRICATED NEW FLOOR PANEL IAW SREO B757-9692-H.SDR IPXA2015041087955Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 251 XJF EDGES HAS PUNCTURES FABRICATED NEW FLOOR PANEL 251 XJF IAW SAMPLE IAW EO B757-5320-9692-H.SDR IPXA2015041087951Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 251 XKF HAS DELAMINATION FABRICATED NEW FLOOR PANEL 251 XKF IAW SAMPLE IAW EO B757-5320-9692-H, MATERIAL A402H-48 X 144 BATCH 2664589.SDR IPXA2015041087950Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 251 X FF EDGES HAS SEVERAL PUNCTURES. FABRICATED NEW FLOOR PANEL 251 X FF IAW SAMPLE IAW EO B757-5320-9692-H MATERIAL A402H X 48 X 144 BATCH 2664589.SDR IPXA2015040987919Shear Web · corrodedINSPECTION TYPE:C, MAIN CARGO DECK FLOOR SHEAR WEB AT RBL 35 BET STA 345 AND 365 HAS CORROSION. REMOVED FASTENERS 07 EA FOR ACCESS IAW SRM 51-40-02-0G. REMOVED CORROSION AREA IAW SRM 51-10-02-06, ORIGINAL MATERIAL .100 MAT LOSS .012 REMAINING MATERIAL .088 FSDR IPXA2015040987911Shear Web · corrodedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR SHEAR WEB AT RBL 35 BETWEEN STA 345 AND STA 365 HAS CORROSION, DOT 82-0351, REMOVED FASTENERS ,07 EA, FOR ACCESS IAW SRM 51-40-02-06. REMOVED CORROSION AREA IAW SRM 51-10-02-06 ORIGNAL MATERIAL .100, MATERIAL .2055SDR IPXA2015040687730Floor Panel · delaminatedINSPECTION TYPE:C8 MAIN CABIN FLOOR PANEL 222XCF IS DELAMINATED ON THE TOP OF THE PANEL. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015041087953Floor Panel · puncturedINSPECTION TYPE:C, CABIN FLOOR PANEL 241 XBF IS PUNCTURED WITH SCREW STUCK UNDER SIDE EDGE FABRICATED NEW FLOOR PANEL 241 XBF IAW SAMPLE IAW EO B757-5320-9692-H.SDR IPXA2015040287660Frame · dentedINSPECTION TYPE: C8, AFT PIT LT SIDE FRAME AT STA 1280, STR 25L DENTED. REPAIRED IAW SRM 53-00-07-2R PROCEDURE 6, REPAIR 6, DETAIL 1.SDR IPXA2015041087956Floor Panel · delaminatedINSPECTION TYPE:C, CABIN FLOOR PANEL 231 XWF IS DELAMINATED/EDGES BROKEN OFF. FABRICATED NEW FLOOR PANEL 231 XWF IAW SAMPLE IAW EO B757-5320-9692-H, MATERIAL A402H-48 X 144 BATCH 2664589.SDR IPXA2015040287628Frame · dentedINSPECTION TYPE:C8, AFT PIT RT SIDE FRAM AT STA 1500, STR 26R DENTED. REPAIRED IAW SRM 53-00-07-2R, PROCEUDRES, REPAIR 5, DETAIL I.SDR IPXA2015040287626Frame · dentedINSPECTION TYPE:C8, AFT PIT LT SIDE HAS SIDE DENT IN FRAM STA 1260, STR 26L, REPAIRED IAW SRM 53-00-07-2R PROCEDURE 6, DETAIL VI.SDR IPXA2015033187592Frame · dentedINSPECTION TYPE:C8, AFT PIT LT SIDE FRAME AT STA 1340, ATR 25L HAS DENT. REPAIRED IAW SRM 53-00-07-2R PROCEDURE 5, REPAIR 5, DETAIL III.SDR IPXA2015032987498Floor Panel · crackedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 241XHF IS CRACKED. FABRICATED MAIN CABIN FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032987497Floor Panel · crackedINSPECTION TYPE:C-8, MAIN FLOOR PANEL 241XFF IS CRACKED. FABRICATED MAIN CABIN FLOOR PANEL 241XFF IAW SREO B757-5320-96-92-H.SDR IPXA2015032987495Floor Panel · crackedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 231XGF IS CRACKED. FABRICATED FLOOR PANEL IAW SREO B757-5320-96-92-H.SDR IPXA2015041287988Structure · damagedMAIN CABIN INNER CHORD BS 480-BS 487 HAS 4 EA DAMAGED HOLES. REPAIRED HOLES IAW REO G18847 AND UPS EO B757-5340-57167-A.SDR IPXA2015040987916Angle · crackedINSPECTION TYPE:C14, NR 2 ENG PYLON ANGLE ATTACHED TO AFT SIDE OF FWD STRUT BULKHEAD POSSIBLE CRACK. FABRICATED PART ALODINED AND PRIMED IAW DWG 313N3052, SRM 51-20-01. INSTALLED IAW DWG 313N3052.SDR IPXA2015040387672Angle · crackedINSPECTION TYPE:C14, 2 ENGINE PYLON ANGLE ATTACHED TO AFT SIDE OF FWD STRUT BULKHEAD POSSIBLE CRACK. FABRICATED PART ALODINED AND PRIMED IAW BAC DWG 313N3052, B757, SRM 51-20-01. INSTALLED IAW BAC DWG 313N3052.SDR IPXA2015040287656Skin · damagedINSPECTION TYPE:C, NR 1 PYLON INBD SKIN DAMAGE. REPAIRED NR 1 PYLON INBD SKIN, PN 311N5046-34 IAW EA 757-5451-27-A2172 AND EO B757-5430-57073-A.SDR IPXA2015041187964Floorbeam · corrodedINSPECTION TYPE:C, 14 FS 1200 T-CAP AT RBL 0-RBL 20 HAS LIGHT CORROSION. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW B757, SRM 53-00-51. REMOVED DAMAGED AREA AND FABRICATED REPAIR DOUBLER AND FILLERS, AND INSTALLED IAW EO B757-5310-57142-A.SDR IPXA2015032287257Life Vest · damagedSUPER NUMERARY 1 LIFE VEST DAMAGED. SEAL OPENED. R & R AS REQUIRED WITH SERVICABLE UNIT, IPC: 25-64-51-01.SDR IPXA2015032187247Attach Fitting · missingDEMO SAFETY HARNESS MISSING CARABINER. R & R DEMO SAFETY HARNESS REF TC 0101-757, AMM 25-60-00.SDR IPXA2015032987494Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 221XLF IS DENTED AND CRUSHED. FABRICATED FLOORBOARD IAW IAW SREO.SDR IPXA2015032887480Floor Panel · delaminatedINSPECTION TYPE:C8, MAIN CABIN FLOOR PANEL 231XFF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032887479Floor Panel · delaminatedINSPECTION TYPE:C8, MAIN CABIN FLOOR PANEL 231 XJF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032887476Floor Panel · crackedINSPECTION TYPE:C8, MAIN CABIN FLOOR PANEL 241XJF IS CRACKED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.