Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015012185383Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XQF DAMAGED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185382Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XMF WITH DENT & TOOL DAMAGE. FABRICATED A NEW FLOOR PANEL IAW REO B757-5320-9692-H.SDR IPXA2015012185381Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XCF HAS DETERIORATED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015012185380Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF DETERIORATED AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185379Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XNF MISSING, AND DAMAGED HONEYCOMB. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185375Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XEF DENTED AND SCRATCHED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185374Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XDF DENTED AT THE EDGE AND MISSING HONEY COMB. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015012185372Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 221XCF DENTED AND TOOL DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185371Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XRF DETERIORATED HONEYCOMB. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185368Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 231XDF DETERIORATED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185366Floor Panel · damagedINSPECTION TYPE: CP 11, MAIN DECK FLOOR PANEL 232XBF MISSING HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185365Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 231XKF MISSING HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185363Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 231XPF HAS DETERIORATED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185362Floor Panel · crackedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XGF CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185357Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XVF HAS DAMAGED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185356Floor Panel · dentedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 221XBF DENTED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185378Floor Panel · crackedINSPECTION TYPE: C, FLOOR PANEL 232XFF IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185370Floor Panel · damagedINSPECTION TYPE: CP11, FLOOR PANEL 232XYF HAS DAMAGE INSERT. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185364Floor Panel · dentedINSPECTION TYPE: CP11, FLOOR PANEL 232XWF HAS A DENT AT THE CORNER. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185355Floor Panel · damagedINSPECTION TYPE:CP11, FLOOR PANEL 231XWF MISSING AN INSERT. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H .SDR IPXA2015012185354Floor Panel · dentedINSPECTION TYPE:CP11, FLOOR PANEL 232XXF HAS A DENT. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015012185353Floor Panel · dentedINSPECTION TYPE: CP11, FLOOR PANEL 231XYF HAS DENT. FABRICATEDED A NEW FLOOR PANEL IAW SREO 5320-9692-W.SDR IPXA2015012685446Floor Panel · delaminatedINSPECTION TYPE: CP11, MCD FLOOR PANEL 231XMF BOTTOM HONEYCOMB PROTECTIVE LAYER IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H2.SDR IPXA2015012685445Floor Panel · delaminatedINSPECTION TYPE:CP11, MCD FLOOR PANEL 231XFF RT SIDE EDGE IS DELAMINATED THE ENTIRE LENGTH OF THE PANEL. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012685441Tee Fitting · corrodedINSPECTION TYPE: C 11, BS 324 LT OTBD SIDE AT CUSP TEE FITTING IS CORRODED IN SPOTS APPROX 8 INCHES GOING AFT. REPAIRED AREA IAW EO 5340-56458-A.SDR IPXA2015012185377Floor Panel · damagedINSPECTION TYPE: CMCD, FLOOR PANEL 231XLF DAMAGE TO THE HONEYCOMB ON ONE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015011685306Floor Panel · damagedFLOOR PANEL 231XNF, HONEYCOMB MATERIAL IS RIPPED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685304Floor Panel · damagedINSPECTION TYPE: CMCD, FLOOR PANEL 231XAF HAS SEVERAL DENTS AND HONEYCOMB MATERIAL MISSING AT FWD AND AFT EDGES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685303Floor Panel · damagedINSPECTION TYPE:CMCD, FLOOR PANEL 232XUF HAS DAMAGED HONEYCOMB. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685302Floor Panel · damagedINSPECTION TYPE: CMCD, FLOOR PANEL 231XSF HONEYCOMB IS DAMAGED AT SEVERAL SPOTS AROUND THE EDGES. FABRICATED A NEW FLOOR PANELIAW SREO B757-5320-9692-H.SDR IPXA2015020485576Skin · damagedINSPECTION TYPE:CP1, UPPER FUSELAGE SKIN HAS LIGHTNING STRIKE, STA 1380-1400, DOT 118-14 BLENDED AREA AT UPPER FUSELAGE SKIN STA 1352-1400 IAW SRM 51-10-02-0G. 2. CHECKED LIMITS ORIG MAT 0.050, REM MAT 0.047, MAT LOSS 0.003 FOUND TO BE WITHIN LIMITS IAW SRM 51SDR IPXA2015020285525Skin · dentedINSPECTION TYPE: C11, BS 228 S23L SKIN DENTED JUST FWD OF FRAME. PERFORMED SKIN REPAIR IAW SRM 53-00-01-2R, REPAIR 3 AND REO-G18703, REV A.SDR IPXA2015012685444Floorboard · damagedINSPECTION TYPE: CP11, MAIN DECK FLOORBOARD 252XUF DAMAGED IN CORNER 122-0141. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H, PN 146N5361-45.SDR IPXA2015012685443Floor Panel · delaminatedINSPECTION TYPE: CP 11, PANEL RACK MAIN DECK FLOOR PANEL 251XQF HAS A AREA OF DELAMINATION AT PREVIOUS. FABBED PANEL 251XQF, PN 146N5361-15 FROM A402H-48X144 IAW SREO B757-5320-9692-H2. STEP B2 OF SREO B757-5320-9692-H REQUIRED. SCUFF SAND AROUND THE STEP CSDR IPXA2015011685312Floorboard · puncturedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 252XEF HAS PUNCTURE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2010116585311Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 241XMF DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO 5320-9692-H.SDR IPXA2015011685310Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 242XMF DAMAGED ON UNDERNEATH SIDE. FABRICATED FLOORBOARD IAW SREO 5320-9692-H.SDR IPXA2015011685309Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XKF DAMAGED AT INSERT. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685307Floorboard · puncturedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 241XGF PUNCTURED. FABRICATED A NEW FLOORBOARD IAW SREO 5320-9692-H.SDR IPXA2015011685305Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XAF DELAMINATED IN CORNER. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011285257Transmission · inoperativeDURING APPROACH, FLAPS SELECTED TO 1, FLAP INDICATOR REMAINED AT UP. T/E FLAP DISAGREE MESSAGE ON EICAS & T/E DISAGREE ILLUMINATED FOLLOWED AOM. DURING ALTERNATE FLAP EXT THE T/E FLAP DISAGREE WENT OUT AND L/E SLAT DISAGREE EICAS MSG CAME ON, AND L/E LIGHT SDR IPXA2015010585204Flap System · warning messageT/E FLAP DISAGREE WHEN FLAPS SELECTED TO 25 FROM 20 POSITION. EMERGENCY DECLARED. NR 1 FSEU FAULT HISTORY SHOWS FLAP FAIL WITH 217. COMPLIED WITH FIM 27.51.00.815.810 FIG 107 TO BLOCK 27. NO FAULTS. R & R NR 1 FSEU AS A PRECAUTION AMM 27.51.01. OPS NORMSDR IPXA2014122685156A/C Pack · contaminatedSTRONG OIL ODOR DETECTED FOR MOST OF THE FLIGHT WITH RT PACK OPERATING, SWITCHING TO LT PACK ONLY ELIMINATED ODOR. REMOVED OIL CONTAMINATION IAW MM 21-00-01-002. PACK OPS CHECKED GOOD.SDR IPXA2014122485139Light · inoperativeIN EMERGENCY LIGHTS "UNARMED" INDICATOR LIGHT INOPERATIVE. R & R LIGHT ASSY IAW AMM 33-13-00.SDR IPXA2014122485130Transceiver · inoperativeWEATHER RADAR FAILED DISPLAYED ON EHSI, EX TEST FAIL DISPLAYED. R & R WEATHER RADAR TRANSCEIVER AND OPS TEST CONDITION BACK TO NORMAL IAW AMM 34-43-01.SDR IPXA2014122285100Transmission · inoperativeDURING APPROACH, SLECTED FLAPS 30, A T/E DISAGREE EICAS MESSAGE ILLUMINATED, DECLARED AN EMERGENCY AND RAN THE T/E DISAGREE ALT CHECKLIST. POSITIONED FLAP 30 WITH ALTERNATE FLAP SELECTOR. HAD MOMENTARY FLAP LOAD RELIEF MESSAGE. R & R OF LEFT INBD, OTBD FLASDR IPXA2014121785070Battery Pack · inoperativeEMERGENCY LIGHTS INOPERTIVE. R & R BATTERY PACK. OPS CHECKED GOOD. ALL WORK DONE IAW AMM 33-51-07.SDR IPXA2014121585060Actuator · inoperativeEMERGENCY DECLARED. UPON SELECTION OF FLAPS 1 "T/E FLAP DISAGREE" MESSAGE ENNUNICATED WORKED T/E FLAP DISAGREE CHECKLIST WHICH CLEARED T/E PROBLEM, HOWEVER, THIS WAS FOLLOWED BY A "L/E SLAT DISAGREE" MSG. WORKED THAT CHECKLIST W/NO RELIEF TO L/E SLAT DISAGRSDR IPXA2014121285048Switch · failedDURING TAKEOFF ROLL, BURNING RUBBER ODOR IN COCKPIT. ONCE AIRBOURN ODOR DIMINISHED. BOTH PACKS ON. NO SMOKE AT CRUISE OR CLIMB OUT. HOWEVER DURING DESENT INTO GSP ODOR RETURNED. ON TAXI IN, ODOR SUBSIDED, ALL ENGINE INDICATIONS NORMAL. NO EICAS MSG FOUNDSDR IPXA2014121285051Adf · inoperativeLEFT ADF POINTER DOES NOT POINT PROPERLY ON BOTH RDMI'S. AUDIO IS NORMAL. WINDS WERE OUT OF LIMITS FOR ANY OTHER RUNWAY. HIT BINGO FUEL RETURNED BACK TO DEPARTURE. REPLACED LEFT ADF RECEIVER IAW MM 34-57-01.
Back to Boeing 757-24APF