Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3579857Floorbeam · corrodedINSPECTION TYPE:C-8, MAIN CABIN BS 1200 LBL 45.5 TO RBL 45.5 FLOORBEAM UPPER FLANGE, UPPER SURFACE CORRODED. FABRICATED NEW REPAIR IAW SRM 53-00-51-2R-6.SDR IPXA3579596Warning Message · false indicationELEVATOR ASYM STATUS MESSAGE. FOUND NO ELEVATOR ASYM STATUS OR MX MESSAGES. OPS CHECKED ELEVATOR POSITION SYS IAW AMM 27-38-00-715-002. NO FAULTS FOUND.SDR IPXA3579588Skin · puncturedINSPECTION TYPE: C-CK, RT INBD MAIN FLAP HAS A SMALL PUNCTURE ON THE UPPER SURFACE. REPAIRED IAW SRM 51-53-01 2R AND 51-70-07-OG.SDR IPXA13579683Skin · damagedINSPECTION TYPE: C1S3, LT INBD MAIN FLAP UPPER SKIN DAMAGED AT APPROX 44.75 FROM INBD END. REPAIRED IAW RCD 012190.SDR IPXA3579557Floor Support · corrodedINSPECTION TYPE:C-8, AFT CARGO FLOOR SUPPORT HAS CORROSION AT BS 1470, RBL 16. R & R FLOOR SUPPORT IAW DWG 146N5447 AND SRM 51-40-02.SDR IPXA3579535Panel · puncturedRT INBD MAIN FLAP COVE PANEL LWR SURFACE 3 DAMAGE AREAS 81" OTBD OF INBD EDGE 3.1" FWD OF AFT EDGE. REPAIRED IAW EO B757-5750-51606-A.SDR IPXA3579531Skin · dentedCARGO DOOR OUTER SKIN DENTED 12.25 INCHES FROM T/E AND 26.5 INCHES FROM UPPER EDGE. REPAIRED IAW EO B757-5230-51602-A.SDR IPXA13579661Floorboard · damagedINSPECTION TYPE: C1S3, MAIN DECK FLOORBOARD 232XTF AFT EDGE HAD DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13579651Floorboard · puncturedINSPECTION TYPE: C1S3, MAIN DECK FLOORBOARD 231XSF HAS NUMEROUS PUNCTURES. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H .SDR IPXA13579659Floorboard · puncturedINSPECTION TYPE: C1S3, FLOORBOARD 231XNF IS PUNCTURED AT BOTTON SURFACE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13579656Floorboard · puncturedINSPECTION TYPE: C1S3, FLOORBOARD 232XQF HAS PUNCTURES AT BOTTOM SURFACE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9693-H.SDR IPXA13579654Floorboard · puncturedINSPECTION TYPE: C1S3, CABIN FLOORBOARD 232XMF BOTTOM SURFACE HAD MULTIPLE PUNCTURES. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13579652Floorboard · brokenINSPECTION TYPE: C1S3, FLOORBOARD 231XPF HAS BROKEN EDGES. FABRICATED NEW FLOORBOARD IAW B757-5320-9692-H .SDR IPXA13579650Floor Panel · puncturedINSPECTION TYPE: C1S3, FLOOR PANEL 231XLF BOTTOM SURFACE HAS MULTIPLE PUNCTURES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H, A402H.SDR IPXA13579649Floor Panel · puncturedINSPECTION TYPE: C1S3, FLOOR PANEL 231XMF MISSING ONE INSERT AND BOTTOM SURFACE HAS PUNCTURED HOLES. FLOOR PANEL FABRICATED IAW EO B757-5320-9692-H.SDR IPXA13579660Floor Panel · puncturedINSPECTION TYPE: X1S3, MCD FLOOR PANEL 241XCF LOWER SURFACE IS PUNCTURED IN APPROXIMATELY EIGHT LOCATIONS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3579553Bulb · burned outEMERGENCY LIGHT ASSY HAS EIGHT BULBS INOPERTIVE. REPLACED BULBS IAW AMM 33-51-01-2.SDR IPXA13579658Floor Panel · delaminatedINSPECTION TYPE: C1S3, MAIN DECK FLOOR PANEL 252XHF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13579657Floor Panel · damagedINSPECTION TYPE :C1S3, MAIN DECK FLOOR PANEL 252XEF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3579506Power Supply · inoperativeINSPECTION TYPE: ASE, EMERGENCY LIGHTS DO NOT STAY ON WHEN SWITCH IS PLACED IN ON POSITION. LIGHTS FLICKER FOR ONE SECOND AND GOES OFF. REMOVED POWER SUPPLY IAW 33-51-07-022-020 INSTALLED POWER SUPPLY IAW 33-51-02-862-054 OPS & FUNCTIONAL TEST CHECKED GOOD ISDR IPXA13579682Skin · damagedINSPECTION TYPE: C1S3, LT INBD MAIN FLAP UPPER SURFACE COMPOSITE SKIN DAMAGED FROM CONTACT WITH WING T/E FIXED PANEL. REPAIRED IAW RCD 011892.SDR IPXA3579519Floor Panel · brokenINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 242XMF BROKEN. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692, APPENDIX B.SDR IPXA20130809700Skin · puncturedINSPECTION TYPE: C1S3 LT AILERON UPPER SURFACE PUNCTURED AND DELAMINATED AT 2 AREAS ON THE INBD END 53-08 LT AILERON UPPER SURFACE REPAIRED IAW SRM 57-60-01.SDR IPXA13579421Splice Plate · corrodedINSPECTION TYPE:C-10, AFT CARGO BAY FLOOR PANEL SPLICE PLATE AT BS 1510 CORRODED. FABRICATED NEW SPLICE STRAP IAW DWG 453N1611-23.SDR IPXA3579538Attach Angle · corrodedINSPECTION TYPE:C10, AFT FUSELAGE BS 1792 TO 1821, S3R ATTACH ANGLE IS CORRODED. R & R ATTACH ANGLE IAW SRM 51-40-02 AND DWG 148N3152.SDR IPXA3579536Support Angle · corrodedINSPECTION TYPE:C10, BS 1787- 1790, S6R HAS A CORRODED SUPPORT ANGLE. R & R ANGLE IAW SRM 51-40-02 AND DWG 148N3141.SDR IPXA3579493Attach Fitting · corrodedINSPECTION TYPE:C-10, AFT FUSELAGE COMPARTMENT AT BS 1787, S3-6R ATTACH STRAP CORRODED. R & R STRAP IAW SRM 51-40-02 AND DWG 148N3138.SDR IPXA3579539Seat Track · corrodedINSPECTION TYPE:C-8, MAIN CABIN SEAT TRACK AT BS 590, LBL 1 HAS CORROSION ON UPPER SURFACE. FABRICATED AND INSTALLED SEAT TRACK SPLICE IAW SRM.SDR IPXA3579537Attach Angle · corrodedINSPECTION TYPE:C10, AFT FUSELAGE COMPARTMENT BS 1820, L6R AREA ADJACENT TO APU DUCT, CORROSION UNDER LONGERON. R & R ATTACH ANGLE, PN 148N3152-1 IAW SRM 51-40-02 AND BAC DWG 148N3152.SDR IPXA13579423Floor Panel · crackedINSPECTION TYPE: C1S2, MAIN DECK FLOOR PANEL 241XFF IS CRACKED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA13579422Floor Panel · puncturedINSPECTION TYPE:C1S2, MAIN DECK FLOOR PANEL 241XMF IS PUCNTURED AROUND FASTENER HOLES. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA3579407Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE. R & R BATTERY PACK IAW AMM 33-51-01/201. TESTED OK.SDR IPXA3579315Wedge · dentedNR 5 L/E SLAT UPPER SURFACE T/E WEDGE DENT 97.5" FROM OTBD EDGE AND 5.5" FROM AFT EDGE REPAIR IAW SRM 51-70-10.SDR IPXA3579556Strap · corrodedINSPECTION TYPE:C-8, VERTICAL STAB TOP CAP INTERNAL METAL STRAP HAS CORROSION. REPLACED METAL STRAP IAW BAC DWG 179N1011-4.SDR IPXA13579602Floorbeam · corrodedINSPECTION TYPE: C-8 MAIN CABIN FLOOR BS 1200, BL 0-LBL 24 HAS CORROSION OUT OF LIMITS. REPAIRED CABIN FLOORBEAM IAW EO B757-5310-51674-A.SDR IPXA13579600Floorbeam · corrodedINSPECTION TYPE:C-8, MAIN CABIN FLOORBEAM BS 1200, LBL 45-62 HAS CORROSION OUT OF LMITS. REPAIRED FLOORBEAM IAW EO B757-5310-51674-A.SDR IPXA3579397Floorboard · brokenINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 232XYF BROKEN AND INSERT PULLED OUT. DAMAGE TO FLOORBOARD EXCEEDS ALLOWABLE LIMITS IAW SREO B757-532 0-18249-E. FABRICATED NEW FLOORBOARD IAW SR EO B757-5320-9692.SDR IPXA3579377Floor Panel · tornINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 232XWF EXTENSION STRIP FASTNER HOLES. FABRICATED NEW FLOOR PANEL IAW SREOB757-5320-9692H.SDR IPXA3579551Frame · crackedINSPECTION TYPE:C-8, MAIN DECK FRAME INNER FLANGE CRACKED BS345, STR 11-12R. FABRICATED AND INSTALLED REPAIR IAW EO B757-5310-51500-A.SDR IPXA3579540Seat Track · corrodedINSPECTION TYPE:C8, MAIN CABIN SEAT TRACK CORRODED AT FASTENER HOLE BS 1681, LBL 45. FABRICATED & INSTALLED SEAT TRACK REPAIR IAW SRM 53-60-52 -2R-1 AND 5300-52-2R-5.SDR IPXA3579396Floorboard · erodedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD EDGE ERODED BS 1040, STR 24.75L. DAMAGED FLOORBOARD EXCEEDS ALLOWABLE LIMITS IAW SREO B757 -5320-18249-E. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579393Floor Panel · puncturedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 222XCF CRACKED AND PUNCTURED ON LOWER SURFACE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579375Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 232XCF DENTED AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA3579374Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 222XBF PUNCTURED AND DENTED LOWER SURFACE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA3579373Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 241XAF EDGE IS ERRODED. FABRICATED NEW MAIN CABIN FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA3579372Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 222XCF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA3579360Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 231XWF DAMAGED INSERT. EVALUATED FLOORBOARD DAMAGE AND FOUND TO BE BEYOND ALLOWABLE LIMITS IAW SREO B757-5320-18249E. FABRICATED FLOORBOARD IAW SREO B757-5320-19692.SDR IPXA3579359Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 231XTF DAMAGED INSERT. DAMAGED INSERT AND ADDITIONAL DAMAGE ON BOTTOM OF FLOORBOARD EXCEEDS ALLOWABLE LIMITS OF SREO B757-5320-18249E. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA3579358Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 231XQF DAMAGED INSERT. DAMAGE TO FLOORBOARD EXCEEDS ALLOWABLE LIMITS IAW SREO B757-53 20-18249-E. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA3579357Floorboard · damagedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 232XYF DAMAGED. DAMAGE TO FLOORBOARD EXCEEDS ALLOWABLE LIMITS IAW SREO B757-532 0-18249E. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.
Back to Boeing 757-24APF