SDR IPXA11567152Floorboard · puncturedINSPECTION TYPE:C1, FOUND FLOORBOARD AT RBL 25 TO 44, STA 345 TO 440, HAS PUNCTURE ON OTBD UNDERSIDE. REPLACED FLOORBOARD IAW SRM 53-00-50-1A 1, EO B757- 5320-9692G.SDR IPXA11567151Floorboard · damagedINSPECTION TYPE:C1, FOUND DAMAGED FLOORBOARD AT RBL 0 TO 25, STA 345 TO 440, ON FWD INBD END OF UNDERSIDE. REPLACED FLOORBOARD IAW SRM 53-00-50-1A 1, EO B757- 5320-9692-G.SDR IPXA1567053Frame · dentedINSPECTION TYPE:SAC9, AFT PIT, FUSELAGE FRAME UPPER FLANGE HAS A DENT, BS 1500, STR-23R. ACCOMPLISHED REPAIR IAW SRM 53-00-07-2R 5 REPAIR 5 EA 110550.SDR IPXA11567495Intercostal · damagedINSPECTION TYPE:C1, SCREW STRIKE ON INTERCOSTAL FROM BS 1380-1400, AT STR15R, BS 1382. REPLACED INTERCOSTAL IAW ER 11-03143 AND EO B757-5310-43226-A.SDR IPXA11567457Floor Panel · damagedINSPECTION TYPE:C1, MCB FLOOR PANEL LBL 45-60 BS 1600-1681 WL 208 HAS EDGE DAMAGE WHICH REQUIRE STEP CUTS. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567456Floor Panel · delaminatedINSPECTION TYPE:C1, MCB FLOOR PANEL BL 0 TO LBL 60, BS 1681-1715, WL 208 HAS DELAMINATION AND EDGE DAMAGE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA1567369Beam · corrodedINSPECTION TYPE:C1, FLOORBEAM AT STA 1040 +15" RBL 26-45 CORRODED. FABRICATED FLOORBEAM AND INSTALLED IAW SRM 5300-52-1A.SDR IPXA11567323Floor Panel · damagedINSPECTION TYPE:C1, MCB FLOOR PANEL BL 0 TO LBL 25, BS 1600-1681, WL 208 HAS EDGE DAMAGE. FABRICATED MCB FLOOR PANEL BL 0 TO LBL 25, BS 1600-1681, WL 208 IAW SRM 53-00-50-1A1, AMM 53-01-01-4.SDR IPXA11567319Floor Support · corrodedINSPECTION TYPE:C1, CORROSION ON MAIN DECK FLOOR SUPPORT BS 900, LBL 21.25 REPAIRED IAW ER 11-03023, SRM51-40-02-0G, SRM 51-10-02-0G.SDR IPXA11567281Support Angle · crackedINSPECTION TYPE: MOD, LT AFT FAIRING STRUCTURE LOWER AFT INBD SUPPORT ANGLE IS CRACKED AT PPS 291. REPLACED ANGLE IAW SRM 51-40-02-0G.SDR IPXA11567280Angle · crackedLEFT AFT FAIRING STRUCTURE LOWER AFT OTBD SUPPORT ANGLE IS CRACKED AT PPS 291. REPLACED IAW SRM 51-40-02-0G.SDR IPXA11567249Seal · bentRT PYLON FWD CHANNEL ON OTBD SIDE IS BENT PN 311N5175-2. R & R SEAL LAND IAW SRM 51-40-02.SDR IPXA11567145Floor Panel · damagedINSPECTION TYPE:C1, FLOOR PANEL LBL 25-45, BS 1600-1681, WL 208 HAS EDGE DAMAGE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A 1, AMM 53-01-01-4, AND EO B757-5320-9692-G.SDR IPXA11567136Floor Panel · damagedINSPECTION TYPE:C1PA, FLOOR PANEL BL0 TO LBL 25, BS 1540-1600, WL 208 HAS DELAMINATION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA11567135Floor Panel · damagedINSPECTION TYPE:C1, FLOOR PANEL, LBL 25-45, BS 1420-1540, WL 208 HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA11567134Floor Panel · damagedINSPECTION TYPE:C1, FLOOR PANEL BL0 TO LBL 25, BS 1200-1320, WL 208 HAS DELAMINATION AND EDGE DAMAGE. FABRICATED NEW PANEL IAW EO B757-5320-9692.SDR IPXA11567130Floorboard · puncturedINSPECTION TYPE:C1, FLOORBOARD LBL 25-45 BS 1540-1600, WL 208 HAS PUNCTURE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11567129Floor Panel · delaminatedINSPECTION TYPE:C1, FLOOR PANEL LBL 45-60, BS 1540-1600, WL 208 HAS DELAMINATION. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A 1, AMM 53-01-01-4 STEP 3.D (12) AND EO B757-5320-9692-G.SDR IPXA11567128Floor Panel · delaminatedINSPECTION TYPE:C1, FLOOR PANEL LBL 45-60, BS 1200-1320, WL 208 HAS DELAMINATION ON LWR SURFACE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A 1, AMM 53-01-01-4, AND EO B757-5320-9692-G.SDR IPXA11567127Floor Panel · delaminatedINSPECTION TYPE:C1, FLOOR PANEL LBL 45-60, BS 1100-1200, WL 208 HAS DELAMINATION ON UPPER SURFACE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A 1, EO B757-5320-9692-G AND AMM 53-01-01-4.SDR IPXA11567126Floor Panel · damagedINSPECTION TYPE:C1, MCB FLOOR PANEL BL0 TO LBL 25 BS 1100-1200 WL 208 HAS EDGE DAMAGE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A 1, AMM 53-01-01-4, AND EO B757-5320-9692-G.SDR IPXA1567030Frame · damagedINSPECTION TYPE:C1, MCB BS 1540 FRAME, BETWEEN STR-15L AND 16L HAS 2 EA SCREW STRIKES. REPAIRED DAMAGE ON FRAME IAW SRM 53-60-07-0I1, SRM 53-00-07-1A1, SRM 51-20-01-0G, SRM 51-40-02-0G, AND EO B757-5310-39560-B, DATED 12/29/2010.SDR IPXA1567029Frame · damagedINSPECTION TYPE:C1, MCB BS 1500 FRAME, BETWEEN STR-15L AND 16L HAS 1 EA SCREW STRIKES. REPAIRED DAMAGE ON FRAME IAW SRM 53-60-07-0I1, SRM 53-00-07-1A1, SRM 51-20-01-0G, SRM 51-40-02-0G, AND EO B757-5310-39560-B, DATED 12/29/2010.SDR IPXA11566987Control Unit · inoperativeEMERGENCY DECLARED - L/E SLAT SYS EICAS MESSAGE L/E SLAT DISAGREE DISPLAYED WITH FLAP LEVER IN 1. BOTH FLAP POINTERS INDICATED 1/2 LOWERED FLAPS WITH ALTERNATE FLAP SECURED. TROUBLESHOT IAW FIM 27-81-00, BLOCK 1 & 26. FOUND FS CK NR 2 FAULT. R & R FSCU IAWSDR IPXA1567646Frame · dentedINSPECTION TYPE:C1 ACB BS 1300 FRAME HAS A DENT ON THE UPPER SURFACE IN BETWEEN STR25L AND STR26L. REPAIRED IAW ER 11-03024, SRM 53-00-07, 51-40-02-OG, 51-10-02-0G.SDR IPXA11567615Frame · dentedINSPECTION TYPE:C1, BULK CARGO BAY, BS 1500 FRAME HAS A DENT ON UPPER SURFACE IN BETWEEN STR 23R AND 24R. REPAIRED IAW SRM 53-00-07-2R-5.SDR IPXA11567598Frame · dentedINSPECTION TYPE:C1 BULK CARGO BAY, B.S 1500 FRAME HAS A DENT ON UPPER SURFACE INBETWEEN STR 23R AND 24R. REPAIRED IAW SRM 53-00-07-2R-5.SDR IPXA11567597Frame · dentedINSPECTION TYPE:C1, BULK CARGO BAY, BS 1580 FRAME HAS A DENT ON UPPER SURFACE IN BETWEEN STR 25R AND STR 26R. REPAIRED IAW SRM 53-00-07-2R-5.SDR IPXA11567572Strap · corrodedINSPECTION TYPE:C1 STABILIZER STRAP HAS CORROSION ON UPPER SURFACE AT NUTPLATE HOLE BS 1401-1414, RBL 45.5, WL 201. REPAIRED IAW ATS ER 11-03052.SDR IPXA11567524Crease Beam · corrodedINSPECTION TYPE:C1, CREASEBEAM HAS CORROSION ON UPPER SURFACE, BS 1587, RBL 63, WL 208. REPAIRED IAW ER 11-03070.SDR IPXA11567493Floor Panel · puncturedINSPECTION TYPE:C1, FLOOR PANEL BS 1540 TO BS 1600, RBL 45 TO RBL 60, WL 208 HAS PUNCTURE DAMAGE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA11567455Floor Panel · puncturedINSPECTION TYPE:C1, MCB FLOOR PANEL BS 1681 TO BS 1720, BL 0 TO RBL 60, WL 208 HAS PUNCTURE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567454Floor Panel · damagedINSPECTION TYPE:C1, FLOOR PANEL BS 1600 TO BS 1681, RBL 45 TO RBL 60, WL 208 HAS EDGE DAMAGE AT AFT END. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567453Frame · dentedINSPECTION TYPE:C1, BULK CARGO BAY, BS 1500 FRAME HAS A DENT ON UPPER SURFACE AT STR 26R. REPAIRED IAW SRM 53-00-07-2RS.SDR IPXA11567449Seat Track · corrodedINSPECTION TYPE:C1, SEAT TRACK HAS AREA OF CORROSION ON UPPER SURFACE AT NUTPLATE HOLE, BS 1184, RBL 60, WL 208. REPAIRED IAW ATS ER 11-03081.SDR IPXA1567417Seat Track · corrodedINSPECTION TYPE:C1, SEAT TRACK HAS CORROSION ON UPPER SURFACE AT 2 ATTACH FASTENERS, BS 1540, RBL 44.5-46.5. R & R SEAT TRACK IAW SRM 51-40-02-0G, 51-40-08-0G, 5300-52-1A.SDR IPXA1567415Floor Panel · crackedINSPECTION TYPE:C1, FLOOR PANEL BS 1200 TO BS 1320, RBL 45.5 TO RBL 60, WL 208 HAS EDGE DAMAGE AND IS CRACKED ON LWR SURFACE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1, AMM 53-01-01-4, AND UPS EO B757-5320-9692-G.SDR IPXA1567412Skin · dentedRIGHT UPPER OTBD HORIZ PANEL DENTED 60" FROM INBD END. REPAIRED IAW SRM 51-70-10, REPAIR NR 4.SDR IPXA1567351Floor Panel · crackedINSPECTION TYPE:C1, FLOOR PANEL, BS 1320, RBL 45.5 TO RBL 60, WL 208 HAS EDGE DAMAGE AND IS CRACKED ON LWR SURFACE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A 1, AMM 53-01-01-4 AND EO B757-85320-9692-G.SDR IPXA1567349Seat Track · corrodedINSPECTION TYPE:C1, SEAT TRACK HAS CORROSION ON UPPER SURFACE AT ATTACH FASTENER, BS 1540, RBL 26, WL 208. R & R SEAT TRACK IAW SRM 51-40-02-0G, SRM 51-10-02-0G SRM 53-00-52-1A 1, SRM 51-40-05-0G, SRM 51-40-08-0G.SDR IPXA11567306Floor Panel · damagedINSPECTION TYPE:C1, MCB FLOOR PANEL BS 1100 TO 1200, BL0 TO RBL 25 WL 208 HAS PUNCTURE DAMAGE. FABRICATED NEW PANEL IAW EO B757-5320-9692.SDR IPXA11567305Floor Panel · damagedINSPECTION TYPE:C1, MCB FLOOR PANEL BS 1200 TO BS 1320, RBL 25 TO RBL 45, WL 208 HAS EDGE DAMAGE. FABRICATED NEW PANEL IAW EO B757-5320-9692.SDR IPXA11567248Channel · chafedINSPECTION TYPE:MOD, LT UNDERWING FAIRING STRUCTURE UPPER FWD CHANNEL ASSY IS WORN AND CHAFED. PN 313N5004-89 R & R CHANNEL IAW SRM 51-40-02.SDR IPXA11567247Floorbeam · corrodedINSPECTION TYPE:C1, BS 1200 FLOORBEAM HAS CORROSION ON UPPER SURFACE AT PREVIOUS BLEND, RBL 49-53, WL 208. REPAIRED IAW ATS ER 11-03007.SDR IPXA11567222Floor Panel · puncturedINSPECTION TYPE:C1, FLOOR PANEL BS 1100-1200 RBL 45.5 TO RBL 60 WL 208 HAS PUNCTURE DAMAGE ON LOWER SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567150Floorboard · delaminatedINSPECTION TYPE:C1, DAMAGED MAIN DECK FLOORBOARD UPPER SURFACE DELAMINATION, BS 1060 TO BS 1100, LBL 45 TO LBL 60. FABRICATED REPLACEMENT MAIN DECK FLOORBOARD IAW SRM 53-00-50-1A1.SDR IPXA11567144Floor Panel · damagedINSPECTION TYPE:C1, FLOOR PANEL BS 1600 TO BS 1681, RBL 25 TO RBL, 45 WL 208 HAS EDGE DAMAGE AT INSERT. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A 1, AMM 53-01-01-4, AND EO B757-5320-9692-G.SDR IPXA11567143Floor Panel · damagedINSPECTION TYPE:C1, FLOOR PANEL BS 1600 TO BS 1681, BL 0 TO RBL 25, WL 208 HAS DAMAGE ON LWR SURFACE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A 1, AMM 53-01-01-4, AND EO B757-5320-9692-G.SDR IPXA11567133Floor Panel · damagedINSPECTION TYPE:C1, FLOOR PANEL BS 1320-1420, BL0 - RBL 25, WL 208 HAS DELAMINATION AND DAMAGED PREVIOUS REPAIR ON UPPER SURFACE. FABRICATED NEW PANEL IAW EO B757-5320-9692.SDR IPXA11567132Floor Panel · damagedINSPECTION TYPE:C1, FLOOR PANEL BS 1320 TO BS 1400, RBL 25 TO RBL 45, WL 208 HAS DELAMINATION AND PUNCTURE DAMAGE. FABRICATED NEW PANEL IAW EO 757-5320-9692.
Back to Boeing 757-24APF