Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10561533Floorbeam · corrodedINSPECTION TYPE:C2, MCB FLOOR SUPPORT SHIM PLATE HAS CORROSION ON UPPER SURFACE BS 1055, WL 208, LBL 4 TO LBL 22. REMOVED, FABRICATED, INSTALLED REPLACEMENT SHIM PLATE.SDR IPXA10561530Plate · scratchedINSPECTION TYPE:C2, MCB FLOOR SUPPORT SHIM PLATE HAS SCRATCHES ON UPPER SURFACE BS 1055, LBL 27 TO LBL 43, WL 208. REMOVED, FABRICATED, INSTALLED REPLACEMENT SHIM PLATE.SDR IPXA10561498Stringer Clip · damagedINSPECTION TYPE:SP, BS 1681 S16R CLIP HAS ELONGATED HOLES IN STRINGER REMOVED, AND INSTALLED STR CLIP IAW EO B757-5310-38884-B AND SRM51-40-05.SDR IPXA10561493Floorboard · debondedINSPECTION TYPE:C2, FLOORBOARD BS 396 TO 440 LBL 25 TO 45 DEBONDED ON LWR SURFACE. R & R IAW EO B757-5320-9692-G & EO B757-5100-33281-B.SDR IPXA10561488Stringer · damagedINSPECTION TYPE:SP, STRINGER 15R AT BS 1681 HAS ELONGATED HOLES AT STRINGER CLIPS. REPAIRED IAW ER NR 10-3713 03AUG2010.SDR IPXA10561487Stringer · damagedINSPECTION TYPE:SP, STRINGER 16R AT BS 1681 ELONGATED HOLES AT STRINGER CLIPS. REPAIRED IAW ER NR 10-3618, DATED 03AUG2010.SDR IPXA10561483Splice · damagedINSPECTION TYPE:C2, SCREW STARTS IN FRAME SPLICE. R & R FRAME SPLICE & FABRICATED IAW SRM 51-40-02-0G & DWG 146N1013.SDR IPXA10561481Floor Panel · brokenINSPECTION TYPE:C2, FLOOR PANEL BROKEN AT AFT EDGE, BS 1100 TO BS 1200, LBL 45 TO LBL 60, WL 208. FABRICATED NEW FLOOR PANEL IAW B757-5320-9692-G.SDR IPXA10561442Bracket · crackedINSPECTION TYPE:C2, NR 1 ENGINE PYLON ACCESS PANEL 835AL FWD HINGE POINT, AFT HINGE BRACKET IS CRACKED. REPLACED BRACKET.SDR IPXA10561437Shear Tie · crackedINSPECTION TYPE:C2, SHEAR TIE CRACKED BS 1300 , STR 20-21LT. R & R SHEAR TIE IAW SRM IAW SRM 51-40-02-OG.SDR IPXA10561433Floorbeam · scratchedINSPECTION TYPE:C2, MCB FLOOR SUPPORT PLATE UPPER SURFACE HAS SEVERAL SCRATCHES BS 1020, LBL 3 TO LBL 22, WL 208. R & R COVER PLATE IAW SRM 51-40-02-OG.SDR IPXA10561432Floorbeam · scratchedINSPECTION TYPE:C2, MCB FLOOR SUPPORT PLATE UPPER SURFACE HAS SEVERAL SCRATCHES BS 900, LBL 27.5 TO LBL 43.5, WL 208. R & R COVER PLATE IAW SRM 51-40-02-OG.SDR IPXA10561427Floorboard · debondedINSPECTION TYPE:C2, FLOORBOARD B/S 340 TO 440, BL 0 TO LBL 25 DEBONDED ON LOWER SURFACE. FABRICATED REPLACEMENT FLOORBOARD IAW EO NR B757-5320-9692.SDR IPXA10561417Support · gougedINSPECTION TYPE:C2, FWD CARGO RT FLOOR TO SIDEWALL SUPPORT UPPER SURFACE IS GOUGED AT BS 810, RBL 23. FWD RT FLOOR TO SIDEWALL SUPPORT WILL BE REPLACED ON CC870405.SDR IPXA10561407Floor Panel · damagedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS EDGE DAMAGE, BS 1055 TO BS 1100, BL 0 TO LBL 25 WL 208. FABRICATED NEW FLOOR PANEL IAW EO NR B757-5320-9692-G.SDR IPXA0561385Floor Panel · damagedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS EDGE DAMAGE BS 1055 TO BS 1100, LBL 25-45, WL 208. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562226Shear Web · corrodedINSPECTION TYPE:C2 CORROSION, TOP OF FLOOR SHEAR WEB, BS 402, LBL 42, WL 208. REPAIRED PER ER 10-3622SDR IPXA10562225Shear Web · corrodedINSPECTION TYPE:C2 CORROSION, TOP OF FLOOR SHEAR WEB, BS 377, LBL 49, WL 208. REPAIRED PER ER 10-3622 DATED 20AUG10SDR IPXA10562217Shear Web · corrodedINSPECTION TYPE:C2 CORROSION, TOP OF FLOOR SHEAR WEB, BS 368-370, LBL 47 WL 208. REPAIRED PER ER 70-3622 DATED 20AUG10SDR IPXA10562216Shear Web · corrodedINSPECTION TYPE:C2 CORROSION, TOP OF FLOOR SHEAR WEB, BS 391-393 LBL 47, WL 208. REPAIRED PER ER 10-3622 DATED 20AUG10.SDR IPXA10562215Shear Web · corrodedINSPECTION TYPE:C2 CORROSION, TOP OF FLOOR SHEAR WEB, BS 391-393 LBL 47, WL 208. REPAIRED PER ER 10-3622 DATED 20 AUG10.SDR IPXA10562214Shear Web · corrodedINSPECTION TYPE:C2 CORROSION, TOP OF FLOOR SHEAR WEB, BS 355-357, LBL 48-50 WL 208. REPAIR PER ER 10-3622 DATED 20AUG10SDR IPXA10561463Frame · damagedINSPECTION TYPE:SP, FUSELAGE FRAME DAMAGE AT 1681.8 BETWEEN STRINGER 14R AND 17R DMI 429895, REPAIRED IAW SRM.SDR IPXA10561436Support Bracket · crackedINSPECTION TYPE:C2, FAIRING FORMER SUPPORT BRACKET CRACKED BS 1300 STR 20-21LT. R & R SUPPORT ANGLE IAW SRM 51-40-05-OG.SDR IPXA10561424Support Bracket · crackedINSPECTION TYPE:C2, FAIRING FORMER SUPPORT BRACKET CRACKED BS 1300, STR 25-26 LT. R & R SUPPORT ANGLE IAW SRM 51-40-02-GSDR IPXA10561323Wedge · out of limitsINSPECTION TYPE:C2, NR 4 SLAT HAS OUT OF LIMIT DENTS (DUE TO CLOSE PROXIMITY) LOCATED ON T/E WEDGE UPPER SURFACE 45" FROM INBD END 2.25" FROM T/E. REPAIRED NR 4 SLAT T/E WEDGE IAW SRM 51-70-10-2R-4 AND SRM 51-70-10-2R-0.SDR IPXA10561180Frame · damagedINSPECTION TYPE:C3, AFT CARGO COMPARTMENT 1300 FRAME BETWEEN STRINGER 20R AND 21R IS DAMAGED. REPAIR IAW ER 10-3268.SDR IPXA10562119Frame · damagedINSPECTION TYPE:C2, SCREW STRIKE ON INBD FLANGE OF FRAME BS 1380, BETWEEN STRINGERS 15L AND 16L. REPAIRED IAW ATS ER10-3736, DATED 8-19-10.SDR IPXA10561870Structure · chafedINSPECTION TYPE:C2, DURING INSP OF LT OTBD MAIN FLAP L/E INBD END, NOTED ADDITIONAL CHAFING IAW EO B757-5750-29979, STEP A (4). REPAIRED FLAP L/E IAW EO B757-5750-39142-A AND ATS ER NR10-3587.SDR IPXA10561310Attach Fitting · looseINSPECTION TYPE:C3, WHILE WORKING CLOSE, FOUND 672HB FWD INBD MOUNT FITTING LOOSE AT ATTACHMENT TO FLAP. REPAIRED IAW ER NR 10-3566 DATED 7-24-10.SDR IPXA10562227Frame · damagedINSPECTION TYPE:C2 INTERIOR, BS 1020 FRAME AT STR 15 R HAS SCREW STRIKE. REPAIRED PER ER#10-3735 DATED 25AUG10SDR IPXA10562080Skin · gougedINSPECTION TYPE:C2, BS 478-480, STR 13-14 LT, 2 EA GOUGES IN SKIN OF FUSELAGE (MARKED). REPAIRED IAW ATS ER 10-3617, DATED 8-21-10.SDR IPXA10562058Fitting · damagedINSPECTION TYPE:C2, MAIN CARGO DOOR CUTOUT FWD, UPPER, STOP PIN FITTING DAMAGED (MARKED). REPLACED FITTING IAW EOB757-5310-15194D, SRM 51-10-02-0G, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-40-06-0G, MM 51-21-10-7, SRM 51-20-01-0G, SOPM 20-50-01, MM 52-32-00-SDR IPXA10562057Fitting · damagedINSPECTION TYPE:C2, MAIN CARGO DOOR CUTOUT AFT, UPPER, STOP PIN FITTING DAMAGED (MARKED). REPLACED FITTING IAW EO B757-5310-15194-D, SRM 51-10-02-0G, SOPM 20-50-01, SRM 51-40-05-0G, MM 51-21-10-7, MM 52-32-00-5, MM 51-31-01-2, EO B757-5320-21032-X.SDR IPXA10561160Floor Panel · damagedFLOOR PANEL DAMAGED POS 5L. REPAIRED IAW EO B757-5320-9692-G.SDR IPXA10561183Window · arcedATB - F/O NOTICED R FRONT WINDOW ARCING NEARING TOP OF CLIMB. CHECKED WITH FLASHLIGHT AND DISCOVERED HAIRLINE CRACK AT TOP OF WINDOW. PARTIALLY REMOVED R-1 WINDOW, THRU STEP 2D13 OF MM 56-11-01-4. SPEED TAPE APPLIED OVER FRAME TO PREVENT WATER INCURSION. COMPSDR IPXA10561462Angle · crackedINSPECTION TYPE:C2, NR1 ENGINE PYLON: CUTOUT FOR PANEL 435AR FWD LOWER CORNER ANGLE IS CRACKED. R & R WITH NEW PART IAW SRM 51-40-02-0G.SDR IPXA10561461Attach Angle · crackedINSPECTION TYPE:C2, NR 2 ENGINE: PANEL 445AR CUTOUT FWD LWR ATTACH ANGLE IS CRACKED. R & R ANGLE IAW SRM 51-40-02-0G.SDR IPXA10561443Striker · wornINSPECTION TYPE:C2, 1 ENGINE PYLON: CUTOUT FOR PANEL 435AL FWD LATCH STRIKER PLATE IS WORN ON FRONT AND BACK SIDE. R & R STRIKER LATCH IAW SRM 51-40-02-0G AND AMM 54-53-02-5.SDR IPXA10561435Frame · gougedINSPECTION TYPE:C2, NR 1 ENGINE PYLON: CUTOUT FOR PANEL 435AR FWD EDGE ATTACH FITTING UPPER NUT PLATE IS GOUGING INTO FITTING MATERIAL. REPLACED NR 1 ENGINE PYLON FRAME CHORD (313N5056-5) IAW SRM 50-40-02 AND 51-40-08.SDR IPXA10561254Panel · dentedINSPECTION TYPE:C2, DENTS IN THE APU COMPARTMENT RT INNER SKIN BS 1889, RBL 38, WL 242.10 TO TO 14" UP FROM RT APU DOOR CUTOUT. REPAIRED APU PANEL IAW SRM 51-70-10-2R-2.SDR IPXA0561951Skin · crackedINSPECTION TYPE:C2, APU LT ACCESS DOOR FWD INBD CORNER BENT. REPAIRED APU DOOR IAW ER NR10-3842.SDR IPXA10561304Skin · chafedINSPECTION TYPE:C3, SKIN CHAFE AT AREA ABOVE RT HORIZONTAL STAB BETWEEN BS 1862 AND BS 1874 COMMON TO SLIDE SEAL AREA, REQUIRES REPAIR. REPAIRED IAW EO B757-5330-38904-A.SDR IPXA10561156Bracket · crackedINSPECTION TYPE:C4, NR1 ENG PYLON SUPPORT CLIP CRACKED AT FASTENER LOCATION AT NAC STA 205 UNDER FWD SIDE OF PANEL 435AR (MARKED, REPLACED CLIP IAW SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-10-02-OG, STEP 8C.SDR IPXA10561136Shear Web · corrodedINSPECTION TYPE:SPEC, WHILE WORKING CUSTOMER CARD NR 886007, FOUND 1 EA PREVIOUS OUT LIMITS AT BS 324, LBL 59 TO LBL 60, WL 208. REPAIRED IAW ER NR 10-3510.SDR IPXA10561135Floor Panel · damagedINSP TYPE: SPEC WHILE WORKING CUSTOMER CARD NR 886007, FOUND 1 EA PREVIOUS BLEND OUT OF LIMITS AT BS 324, LBL 59 TO LBL 60, WL 208. REPAIRED IAW ATS ER NR 10-3510 AND EO B757-5320-9692-G.SDR IPXA10562293Frame · damagedINSPECTION TYPE:C3, ACCOMPLISH EO B757-5310-25199B. REPLACED INNER CHORD OF FUSELAGE FRAME REPAIR AT BS 940, S-14L TO S-16L. REPAIRED IAW EO B757-5310-25199B.SDR IPXA10562038Frame · damagedINSPECTION TYPE:C3, ACCOMPLISH EO B757-5310-25200B FRAME REPAIR AT BS 1020, S-14L TO S-16L. ACCOMPLISHED EO B757-5310-25200B FRAME REPAIR AT BS1020 A14L TO S-16L.SDR IPXA10561137Floor Panel · out of limitsINSPECTION TYPE:SP, WHILE WORKING CUSTOMER CARD NR 886006, FOUND 1 EA. PREVIOUS BLEND OUT OF LIMITS AT BS 430.5, LBL 47.25, WL 208. REPAIRED IAW ATS ER NR 10-3508 AND EO B757-5320-9692-G.SDR IPXA10561143Wedge · dentedINSPECTION TYPE:C4, NR 1 SLAT HAS 2 OUT OF LIMITS DENTS. REPAIR WAS ACCOMPLISHED IAW SRM 51-70-10.
Back to Boeing 757-24APF