SDR IPXA10558295Floor Panel · delaminatedINSPECTION TYPE:C1 CABIN FLOOR PANEL B/S 1320-B/S 1420, BL 0-RBL 25, UPPER SURFACE DELAMINATED AT FWD END FLOOR PANEL REPLACED IAW EO B757-5320-9692-F.SDR IPXA10558282Floor Panel · delaminatedINSPECTION TYPE:C2 MAIN DECK FLOOR PANEL BS 900-1020 RBL 25-45 IS DELAMINATED. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM ADDENDUM B757-5320-9682-F.SDR IPXA10558281Floor Panel · damagedINSPECTION TYPE:C2 THE MAIN CARGO BAY FLOOR PANEL BS720-820 BL0 RBL25 IS MISSING AN INSERT. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM ADDENDUM B757-5320-9692F.SDR IPXA10558280Floor Panel · puncturedINSPECTION TYPE:C2 THE MAIN CARGO BAY FLOOR PANEL BS 820-880 BL0 RBL 25 IS DENTED AND PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM ADDENDUM B757-5320-9692-F.SDR IPXA10558413Frame · gougedINSP TYPE:C3 MAIN CARGO DOOR HAS 3 SCREW STARTS AT 486 WL 212 AND 213 REMOVED AND REPLACED MAIN CARGO DOOR FWD FRAME DOUBLER IAW DWG 65-25327, AMM 52-32-05-4, AMM 51-21-04-7 AND SRM 51-40-02.SDR IPXA10558322Floor Panel · corrodedINSPECTION TYPE:C3, AFT CARGO BAY FLOOR PANEL NR 2 PREVIOUS REPAIR IS DISBONDING AROUND EDGES. REPLACED FLOOR PANEL IAW SRM 51-40-05-0G, SRM 53-60-53-0I-1.SDR IPXA10558321Floor Panel · corrodedINSPECTION TYPE:C3, AFT CARGO BAY FLOOR PANEL NR 4 HAS AREA'S OF CORROSION ON UPPER SURFACE. REPLACED FLOOR PANEL IAW SRM 51-40-05-0G, SRM 53-60-53-0I-1.SDR IPXA10558320Web · damagedINSPECTION TYPE:C3, MAIN CARGO DOOR HAS SCREW STARTS AT STA 582 WL 214 REPAIRED MAIN CARGO DOOR WEB IAW SRM 52-30-02-1A-1.SDR IPXA10558316Floor Panel · corrodedINSPECTION TYPE:C-3, LWR FWD CARGO BAY, NR 4 FLOOR PANEL HAS CORROSION AT CONTACT POINT WITH MBA. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 51-40-05-0G, 51-40-06-0G, AND 51-40-08-0G.SDR IPXA10558315Floor Panel · corrodedINSPECTION TYPE:C-3, LWR, FWD CARGO BAY, NR 3 FLOOR PANEL HAS CORROSION AT CONTACT POINT WITH MBA. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 51-40-05-0G, 51-40-06-0G, AND 51-40-08-0G.SDR IPXA10558314Floor Panel · corrodedINSPECTION TYPE:C-3 AFT CARGO BAY FLOOR PANEL NR 3 HAS AREAS OF CORROSION ON UPPER SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 51-40-05-0G, 51-40-06-0G, AND 51-40-08-0G.SDR IPXA10558313Floor Panel · corrodedINSPECTION TYPE:C-3 AFT CARGO BAY FLOOR PANEL NR 1 HAS AREAS OF CORROSION ON UPPER SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 51-40-05-0G AND 51-40-08-0G.SDR IPXA10558293Access Panel · damagedINSPECTION TYPE:C3 MAIN CARGO DOOR HAS SCREW STARTS AT STA 592 WL 214 DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 51-30-02-1A1, REMOVED, FABRICATED, INSTALLED NEW ACCESS PANEL ON WEB STA 592 WL 214, IAW SRM 51-40-02-0G, 51-40-05-0G, SRM 51-10-02-0G.SDR IPXA10558292Access Panel · damagedINSPECTION TYPE:C3 MAIN CARGO DOOR HAS SCREW STARTS AT STA 507.5 THROUGH BS 517.0 FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM 52-30-02-1A1, REMOVED, FABRICATED NEW ACCESS PANEL AND INSTALLED SRM 51-40-02-0G, SRM 51-40-05-0G, MM 51-21-04-7.SDR IPXA10558271Floorbeam · crackedINSP TYPE:C2 UPPER LOBE FLOOR SUPPORT UPPER WEB STRIP TORN AND CRACKED, BS 1016 LBL 26-LBL 44 WL 208, MARKED REMOVED AND REPLACED IAW SRM 51-40-02.SDR IPXA10558268Support · corrodedINSPECTION TYPE:C2 FWD CARGO FLOOR TO SIDEWALL SUPPORT CORRODED AT BS 660 RBL 22. REWORKED IAW SRM 51-10-02.SDR IPXA10558267Support · corrodedINSP TYPE:C2 FWD CARGO RT FLOOR TO SIDEWALL SUPPORT CORRODED UNDERNEATH NUTPLATE BS 818.5 RBL 19.5 REWORKED IAW SRM 51-10-02.SDR IPXA10558266Floorbeam · crackedINSP TYPE:C2 FOUND CRACK AND GOUGES ON RT FLOOR SUPPORT STA 1021 FROM RBL 3 TO 22. REMOVED AND REPLACED IAW SRM 51-40-02 AND 51-20-00-0 AND 53-01-60.SDR IPXA10558265Floorbeam · crackedINSPECTION TYPE:C2 FOUND CRACK ON RT FLOORBEAM STA 1016 FROM RBL 44 TO 43. REMOVED & REPLACED IAW SRM 51-40-02 AND 51-20-00-0 AND 53-01-60.SDR IPXA10558264Floorbeam · crackedINSP TYPE:C2 UPPER LOBE FLOOR SUPPORT UPPER WEB STRIP TORN AND CRACKED, BS 1020 BL0 - LBL 24 WL 208, MARKED R & R IAW SRM 51-40-02.SDR IPXA10558242Sleeve · chafedINSPECTION TYPE:C2 NR 2 ENGINE OTBD C-DUCT, TRANSLATING SLEEVE INNER AFT LOWER EDGE IS CHAFED, WITH FIBER DAMAGE, FROM AFT EDGE TO 8" FWD REPAIRED TRANSLATING SLEEVE IAW SRM 54-31-01-1A FIG 101, SRM 54-31-01-2R FIG 201, SRM 51-70-17-0G PAR 4.6(1-3)SDR IPXA10558476Floorbeam · corrodedINSPECTION TYPE:C1 FLOORBEAM CORRODED AT FASTENER HOLES, BS 1200, BL 0 TO RBL 60. REPAIRED PER ATS ER 10-1318.SDR IPXA10558475Floorbeam · corrodedINSPECTION TYPE:C1 FLOORBEAM CORRODED AT FASTENER HOLES, BS 1200, BL 0 TO LBL 60. REPAIRED PER ATS ER 10-1318.SDR IPXA10558463Web · gougedINSPECTION TYPE:C1 9G BULKHEAD FLOOR WEB IS GOUGED AT BS 324 RBL 11 WL 208 REPAIRED IAW ATS ER 10-1271.SDR IPXA10558462Web · corrodedINSPECTION TYPE:C1, FLOOR WEB WL 208 IS CORRODED ALONG LBL 23 BS 341-372 REPAIRED PER ATS ER 10-1347.SDR IPXA10558461Floorbeam · gougedINSPECTION TYPE:C1, FLOORBEAM UPPER CHORD IS GOUGED (UNDER FLOOR WEB) BS 324 RBL 11 WL 208. REPAIRED IAW ATS ER 10-1271.SDR IPXA10558443Seat Track · corrodedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR B/S 560 TO B/S 620, LBL 24, WL 208 CARGO TRACK FLANGE IS CORRODED IN SEVERAL LOCATIONS. REPAIRED SEAT TRACK B/S 530-B/S 630, LBL 24, WL 208 IAW SRM 53-00-52-2R.SDR IPXA10558442Seat Track · corrodedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR B/S 613 RBL 24 CARGO TRACK FLANGE CORRODED AT FASTENER HOLE. REPAIRED SEAT TRACK B/S 590 - B/S 630 RBL 24 IAW SRM 53-00-52-2R.SDR IPXA10558441Floor Support · gougedINSPECTION TYPE:C1, FLOOR SPLICE CHANNEL GOUGED AT BS 312-322 RBL 11 WL 208 REMOVED FABRICATED AND INSTALLED REPLACEMENT SUPPORT IAW SRM 51-40-02.SDR IPXA10558440Floor Support · gougedINSPECTION TYPE:C1, FLOOR SPLICE CHANNEL GOUGED AT BS 310 RBL 11 WL 208. REMOVED FABRICATED AND INSTALLED REPLACEMENT SUPPORT IAW SRM 51-40-02.SDR IPXA10558434Floor Panel · crackedINSPECTION TYPE:C1, FLOOR PANEL HAS A 14" LONG CRACK AT BS 1150, RBL 45-60 WL 208. FABRICATED REPLACEMENT PANEL IAW ER B757-5320-9692-F.SDR IPXA10558431Channel · gougedINSPECTION TYPE:C1, FLOOR DRAIN CHANNEL IS GOUGED AT BS 278-324 LBL 62 WL 208 REPAIRED DRAIN PAN IAW ATS ESR 10-1306.SDR IPXA10558430Strap · corrodedINSPECTION TYPE:C3, CORROSION AROUND NUTPLATES AT PERIPHERY OF APU INLET HOUSING (MARKED IN TAIL COMPT). REPAIRED IAW ER NR 10-1302 DATED 02-08-10.SDR IPXA10558418Seat Track · corrodedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR B/S 613 RBL 24 CARGO TRACK FLANGE CORRODED AT FASTENER HOLE. REPAIRED SEAT TRACK B/S 590 - B/S 630 RBL 24 IAW SRM 53-00-52-2R.SDR IPXA10558417Seat Track · corrodedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR B/S 560 TO B/S 620, LBL 24, WL 208 CARGO TRACK FLANGE IS CORRODED IN SEVERAL LOCATIONS. REPAIRED SEAT TRACK B/S 530 - B/S 630, LBL 24, WL 208 IAW SRM 53-00-52-2R.SDR IPXA10558416Seat Track · damagedINSPECTION TYPE:C1 DRILL START ON UPPER FLANGE OF SEAT TRACK B/S 1165 LBL 1 WL 208. R & R SEAT TRACK B/S 1080 - B/S 1180, BL 0, WL 208 IAW SRM 51-10-02-0G AND SRM 51-40-02-OG.SDR IPXA10558395Floorbeam · corrodedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR BS 780 RBL 49 UPPER FLANGE OF FLOORBEAM IS CORRODED. REPAIRED FLOORBEAM UPPER CHORD IAW ATS INC. ER NR10-1333 DATED 02FEB10.SDR IPXA10558386Intercostal · crackedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR BS 843 LBL 16 INTERCOSTAL UPPER SURFACE IS CRACKED. REPLACED INTERCOSTAL UPPER IAW SRM 51-40-02-0G, SRM 51-40-05, AMM 51-21-00.SDR IPXA10558385Intercostal · damagedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR BS 483 RBL 10 WL 208 INTERCOSTAL UPPER FLANGE IS DAMAGED AT THE FASTENER HOLE. REMOVED AND REPLACED THE (CHORD) INTERCOSTAL IAW SRM 51-40-05, 51-40-02.SDR IPXA10558384Intercostal · damagedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR BS 483 RBL 45 WL 208 INTERCOSTAL UPPER FLANGE AT FASTENER HOLE IS DAMAGED. REMOVED AND REPLACED (ANGLE) INTERCOSTAL IAW SRM 51-40-02, SRM 51-40-05.SDR IPXA10558367Seat Track · corrodedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR BS 537 TO 542 RBL 44 WL 208 CARGO TRACK FLANGE AND TRACK WELL IS CORRODED. REMOVED CORROSION FROM MCB CARGO BAY TRACK FLANGE AND TRACK WELL SEAT TRACK TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-52-1A REPLACED SEAT SDR IPXA10558366Skin · damagedINSPECTION TYPE:C3, R/W INBD AFT FLAP PREVIOUS REPAIR OF LIGHTNING DAMAGE 3 FT OUT FROM FUSELAGE WAS ACCOMPLISHED INCORRECTLY. REQUIRES REMOVAL AND REACCOMPLISHED (REF EFN 459LGP1004 EO. NR B757-5100-36085) FLAP WAS REPAIRED IAW SRM 51-70-04 PARA 5E.SDR IPXA10558364Intercostal · corrodedINSPECTION TYPE:C1, CORROSION ON UPPER FLANGE OF INTERCOSTAL, BS 1056, LBL 2 TO LBL 25, WL 208. REMOVED AND REPLACED INTERCOSTAL.SDR IPXA10558363Intercostal · corrodedINSPECTION TYPE:C1, CORROSION ON UPPER FLANGE OF INTERCOSTAL, BS 1056, LBL 25 TO LBL 45, WL 208. REMOVED AND REPLACED INTERCOSTAL.SDR IPXA10558358Intercostal · corrodedINSPECTION TYPE:C1 CORROSION ON UPPER FLANGE OF INTERCOSTAL BS 1054, RBL 25, TO RBL 45, WL 208. BLENDED & FOUND TO BE OUT OF LIMITS, FABRICATED & INSTALLED REPLACEMENT INTERCOSTAL IAW SRM 51-40-02 & IAW BAC 1505-100-590 & DWG NR 144N5005.SDR IPXA10558357Beam · corrodedINSPECTION TYPE:C1 CORROSION ON UPPER FLANGE OF LONGITUDINAL BEAM B/S 1045 TO B/S 1055, LBL 46, WL 208. REMOVED AND REPLACED LONGITUDINAL BEAM CAP B/S 1040 - B/S 1080 LBL 45 IAW SRM 51-40-2, SRM 51-40-5, SRM 51-40-8, AND DWG 144N8017 SHT 5.SDR IPXA10558356Intercostal · corrodedINSPECTION TYPE:C1, CORROSION ON UPPER FLANGE OF INTERCOSTAL, BS 1014, RBL 25 TO RBL 45, WL 208. REMOVED AND REPLACED INTERCOSTAL IAW SRM 53-00-51-1A FIG 101; SRM 51-40-02, SRM 51-40-05; SRM 51-20-01-0G.SDR IPXA10558345Intercostal · corrodedINSPECTION TYPE:C1, CORROSION ON UPPER FLANGE OF INTERCOSTAL BS 1016, LBL 26 TO LBL 44. REMOVED AND REPLACED INTERCOSTAL IAW SRM 53-00-51-1A, SRM 51-40-2 AND AMM 51-21-10.SDR IPXA10558344Intercostal · corrodedINSPECTION TYPE:C1, CORROSION ON UPPER FLANGE OF INTERCOSTAL, BS1020, LBL 2 TO LBL 24 WL 208. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-40-02, AMM 51-21-10, SRM 53-00-51-1A.SDR IPXA10558328Floor Panel · debondedINSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR BS 620 TO BS 720 RBL 45 TO RBL 65 FLOORBOARD UPPER SURFACE IS DISBONDED IN SEVERAL LOCATIONS. FABRICATED REPLACEMENT PANEL IAW EO NR B757-5320-9692-F.
Back to Boeing 757-24APF