Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS99531163Actuator · leakingPILOT REPORT, CENTER HYD QTY LOSS IN FLIGHT. REMOVED AND REPLACED NR 1 SPOILER ACTUATOR.SDR UPS99531138Engine · failedINSPECTION TYPE:N/A, PACK SMELL DURING FLIGHT, MOSTLY ON LEFT PACK. RIGHT PACK FREE OF SMELL IN FLIGHT. REMOVED AND REPLACED RIGHT ENGINE PER TC NR 5001.SDR UPS99531052Skin · crackedINSPECTION TYPE: N/A, AFT LOWER CARGO DOOR HAS SKIN CRACK OUT OF SRM LIMITS. *S/D* STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 52-30-01.SDR UPS99531017Support · crackedINSPECTION TYPE:C, AFT CARGO LT FLOOR/SIDEWALL SUPPORT PLATE IS CRACKED AND IS GOUGED IN SEVERAL PLACES BS 1357-1349. REMOVED DAMAGE, FABRICATED DOUBLER AND INSTALLED ALL WORK DONE IAW SRM'S 53-00-53, 51-70-13, 51-40-02 AND MM 25-50-02.SDR 99ZZZX4009Carbon Seal · failedTEAR DOWN INSPECTION REVEALED NR 2 CARBON SEAL FRACTURED APPROXIMATELY .250 INCH WIDE BY 2.300 INCHES LONG AND FAILED SECTION ADHERED TO SEAL PLATE FACE. LOCKING TABS OF 6TH DISK TIE RODS LIBERATED, POSSIBLE FRACTURE CAUSE. P & W ENGINEERING E.H., IS CONDUCTSDR UPS99530675Radome · damagedINSPECTION TYPE:N/A, PILOT REPORT, RADOME DAMAGED FROM BIRD STRIKE EXCEEDS LIMITS. REMOVED AND REPLACED RADOME PER MM 53-12-01 PAGE 201 (P/N 4910-400), (S/N 393NF) ON, (P/N 121N 7820-12), (S/N 150) OFF.SDR UPS99530652Engine · failedINSPECTION TYPE:N/A, AIR TURNBACK - CARGO FIRE WARNING WITH ACRID SMOKE. CARGO FIRE SWITCH DEPRESSED. ACFT EVACUATED ON TAXIWAY AFTER LANDING. INFLT, AUTOPILOT WOULD NOT ENGAGE, COLOR WAS NOT PRESENT ON ADI'S. *S/D* T/S FOUND ENG LEAKING OIL IN BLEED AIR SDR UPS99530716Trunnion · corrodedINSPECTION TYPE:C CORROSION (C57-651-02-11) RT MLG TRUNNION BRG BORE HAS CORRODED AT REAR SPAR REMOVED AND REPLACED FWD TRUNNION BEARING MM 57-54-05 PARA 2 PG 401SDR UPS99530715Trunnion · corrodedINSPECTION TYPE:C LT MLG FWD TRUNNION BRG BORE HAS CORROSION AT REAR SPAR. REMOVED LT FWD TRUNNION BRG SUPPORT BRACKET. REMOVED LT BEARING SUPPORT. REMOVED BEARING FROM SUPPORT CLEAN AND INSPECT SUPPORT REINSTALLED.SDR UPS99530578Support · crackedINSPECTION TYPE:C, FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT CRACKED. REMOVED DAMAGED SECTION, FABRICATED REPAIR PARTS AND INSTALLED.SDR UPS99530577Support · crackedINSPECTION TYPE:C, AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CRACKED BS 1475 RT. REMOVED DAMAGED SECTION, FABRICATED REPAIR PARTS AND INSTALLED.SDR UPS99530473Sequence Valve · failedINSPECTION TYPE:N/A, NOSE GEAR GREEN DOWN LIGHT FAILED TO ILLUMINATE WITH GEAR HANDLE DOWN. EICAS MESSAGE GEAR DISAGREE AND GEAR DOORS DISPLAYED DOORS AND GEAR AMBER LIGHTS ILLUMINATED. INDICATIONS NORMAL AFTER ALTN GEAR EXT, EXCEPT DOORS LIGHT REMAINED ILLSDR UPS99530312Eicas · inopON DESCENT, MULTIPLE WARNINGS (FALSE) INCLUDING ENG FIRE, CARGO FIRE, GEAR DISAGREE. SELECTING RIGHT EICAS COMPUTER CORRECTED PROBLEM. LEFT EICAS COMPUTER WAS DEFFERED OUT OF SJC ON A ONE DAY TIME LIMIT REPLACED IN DSM ON 08/10/99. NO FURTHER PROBLEMS EICASSDR UPS99530281Actuator · failedAT GEAR EXTENSION, NOSE GEAR NOT DOWN MESSAGE DISPLAYED ON EICAS ALONG WITH GEAR DISAGREE AND GEAR DOOR MSGS. ALSO, GEAR AND DOOR AMBER LIGHTS REMAINED ILLUMINATED. ALTERNATE GEAR EXTENSION RESULTED IN SAME INDICATION. REPLACED NOSE LANDING GEAR DOWNLOCK ASDR UPS99530099Beam · corrodedINSPECTION TYPE:C, IN THE MAIN CARGO DECK, THE LONGITUDINAL BEAM RBL 45 HAS AREAS OF CORROSION AROUND NUT PLATES BETWEEN BS 1040-1080. REMOVED CORROSION. REWORK OUT OF LIMITS IAW SRM 53-00-51 PG 101-103. REPLACED LONGITUDINAL BEAM IAW SRM 53-40-51 FIG 1 PG SDR UPS99530098Beam · corrodedINSPECTION TYPE:C IN THE MAIN CARGO DECK, THE LONGITUDINAL BEAM AT BS 900-1040 RBL 45 HAS AREAS OF CORROSION AROUND NUT PLATES. CORROSION REMOVAL OUT OF LIMITS IAW SRM 53-00-51. REPLACED LONGITUDINAL BEAM FROM 900-1080 IAW SRM 53-40-51, 51-40-02, 51-21-01 , SDR UPS99529918Altimeter · inoperativeINSPECTION TYPE:N/A, AIR TURNBACK 0705Z. REASON FOR AIR TURNBACK IS INOP CAPTAINS ALTIMETER. INSTALLED BORROWED PART IN SERVICEABLE CONDITION IN CAPTAINS ALTIMETER AS PER M/M 34-13-01. OPS CHECKED GOOD. UPS PART OFF (P/N 4039892-904) (S/N 96073867) BORROWESDR UPS99529980Seat Track · corrodedINSPECTION TYPE:C, MAIN DECK SEAT TRACK ON EXPANSION LINK HAS CORROSION ON TOP SURFACE LT FLANGE LBL 46, BS 892 AND BS 895. CORROSION FOUND TO BE OUT OF LIMITS. REMOVED OLD SEAT TRACK AND INSTALLED NEW SEAT TRACK AT EXPANSION LINK BS 880 TO BS 900 IAW SRM 53SDR UPS99529522Hyd Line · chafedINSPECTION TYPE:N/A, ON DESENT RECIEVED A LEFT HYD QTY EICAS MESSAGE, NOTICED QTY WAS ABOUT HALF FULL AND DECREASING. AFTER LANDING MX FOUND A HYD LINE TO CARGO DOOR MANUAL PUMP HAD A HOLE WHERE ELEC PUMP WIRE BUNDLE CHAFED IT. ALSO, FOUND NR 1 AND NR 3 LT ESDR UPS99529376Support · damagedINSPECTION TYPE:C AFT CARGO COMPARTMENT FLOOR TO S/W SUPPORT PLATE STA 1375 RT IS PUNCTURED. REMOVED DAMAGED SECTION. FABRICATED A NEW DOUBLER. ALODINED AND PRIMED DOUBLER. INSTALLED DOUBLER. ALL WORK ACCOMPLISHED IAW SRM 51-70-13 AND 51-40-2SDR UPS99529153Beam · corrodedINSPECTION TYPE-C, MAIN DECK OVERWING LONGITUDINAL BEAM HAS CORROSION ALONG OUTBOARD FLANGE AT BS 900 TO 1040 RBL 45 WL 208. REMOVED CORROSION ON LONGITUDINAL BEAM FROM BS 900 TO 1040, FOUND SEVERAL AREAS OUT OF LIMITS. REMOVED CORRODED LONGITUDINAL BEAM AND ISDR UPS99529151Beam · corrodedINSPECTION TYP-C, MAIN DECK OVERWING LONGITUDINAL BEAM HAS CORROSION ON OUTBOARD FLANGE AT BS 1064 RBL 47 WL 208. REMOVED CORROSION ON LONGITUDINAL BEAM, FOUND TO BE OUT OF LIMITS. REMOVED LONGITUDINAL BEAM AT BS 1040 TO 1080, RBL 45.5 AND INSTALLED NEW LONGITSDR UPS99529150Seat Track · corrodedINSPECTION TYPE-C, MAIN DECK SEAT TRACK HAS CORROSION ALONG BOTH FLANGES AT BS 1180 TO 1200 RBL 25 WL 208. REMOVED AND INSTALLED NEW SEAT TRACK, WORK DONE IAW SRM 51-40-05, 51-40-08 AND SRM 51-40-09.SDR UPS99528762Battery Pack · dischargedINSPECTION TYPE-N/A, EMER EXIT LIGHT FAILED TO COME ON DURING TEST. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AND OPERATIONAL FUNCTION CKS GOOD. ACFT OK FOR SERVICE PER MM 33-51-07.SDR UPS99528744Valve · malfunctionedINSPECTION TYPE-N/A, DURING FLT RT PACK TEMP LIGHT ILLUMINATED WITH RT PACK ON AND LT PACK OFF. RT PACK INOP LIGHT THEN ILLUM MOMENTARILY, TURNED RT PACK OFF AND LT PACK ON. LARGE AMOUNT OF SMOKE STARTED OUT OF VENTS BELOW GLARESHIELD. TURNED RT PACK BACK OSDR UPS99528529Frame · dentedINSPECTION TYPE-C4, FRAME IS DENTED AT BS 1300 STR 25 RT. REMOVED DAMAGED AREA OF THE FRAME BS 1300 STR 25 RT. FABRICATED DOUBLER, HEAT TREATED AND INSTALLED REPAIR PARTS PER SRM 51-70-11, SRM 51-40-02.SDR UPS99528528Frame · dentedINSPECTION TYPE-C4, FRAME IS DENTED AT BS 1260 STR 25 LT. REMOVED DAMAGED AREA, FABRICATED DOUBLER, HEAT TREATED AND INSTALLED PER SRM 51-70-11.SDR UPS99528527Frame · crackedINSPECTION TYPE-C4, FRAME AT STA 1500 LBL 29 WL 151 IS CRACKED IN AFT CARGO BAY. REMOVED DAMAGED AREA, FABRICATED FRAME DOUBLER AND INSTALLED PER SRM 51-70-11 AND SRM 51-40-02.SDR UPS99528526Frame · crackedINSPECTION TYPE-C4, FRAME AT STA 1480 LBL 29 WL 152 IS CRACKED IN AFT CGO BAY. REMOVED DAMAGED AREA AND FABRICATED REPAIR DOUBLER PER SRM 51-70-11 AND INSTALLED SRM 51-24-03, SRM 51-20-01.SDR UPS99528525Frame · dentedINSPECTION TYPE-C4, FRAME AT STA 1540 RBL 20.5, WL 154 IS DENTED IN AFT CGO BAY. REMOVED DAMAGED AREA AND FABRICATED DOUBLER AND INSTALLED PER SRM 51-70-11 SRM 51-30-2.SDR UPS99528333Sensor · failedINSPECTION TYPE-N/A, EICAS MSG NOS A/G DISAGREE IN FLIGHT. REPEAT DISCREPANCY, S10067 FAILS NEAR TARGET TEST WITH NORMAL TARGET GAP VERIFIED. REPLACED FAULTY NOSE GEAR NOT COMPRESSED SENSOR, S10067 PER MM 32-09-08 EXCEPT FOR PERMANENT ELECTRICAL CONNECTION.SDR UPS99528368Seat Track · crackedINSPECTION TYPE:S-1 CRACKED SEAT TRACK FLANGE AT BS 1010, RBL 16, WL 156. REMOVED CRACKED SEAT TRACK SECTION FROM BS 950-BS 1010 RBL 16, WL 156. INSTALLED NEW SEAT TRACK PER SRM 51-10-1.SDR UPS99528331Retract Mech · malfunctionedINSPECTION TYPE-N/A, ON DEPARTURE WHEN GEAR HANDLE RAISED TO UP NOSE GEAR GREEN LIGHT REMAINED ON, DOOR LIGHT ON, GEAR DISAGREE EICAS AND LOUD NOISE LIKE GEAR HANGING. LOWERED GEAR HANDLE TO DOWN AND GOT GOOD INDICATION, RE-RAISED GEAR HANDLE AND ALL GEAR FAISDR UPS98528291Eicas · failedINSPECTION TYPE-N/A DURING CRUISE, NUMEROUS WARNING, CAUTION AND STATUS MESSAGES APPEARED. INCLUDED WERE APU FIRE, ENGINE FIRE AND CARGO FIRE. THE MASTER CAUTION LIGHT ILLUMINATED, BUT NO FIRE WARNING BELLS. REPLACED LEFT EICAS COMPUTER AND TESTED PER MM 31SDR UPS98527680Goggles · crackedINSPECTION TYPE-W/E, 1 PAIR OF JUMPSEAT SMOKE GOGGLES CRACKED. INSTALLED SERVICEABLE SMOKE GOGGLES IN JUMPSEAT POSITION.SDR UPS98527650Battery · dischargedINSPECTION TYPE P-DP FORWARD EMERGENCY EXIT LIGHT INOP. REPLACED BATTERY.SDR UPS98527486Bulb · failedINSPECTION TYPE-N/A, EN ROUNTE DID A LIGHT TEST AND OBSERVE RIGHT MAIN GEAR LIGHT INOP. CALLED MMOC TO CHANGE LIGHTS AND OBSERVED BOTH MAIN GEAR LIGHTS WERE INOP. DID A FLY-BY IN DSM. AIRCRAFT NEEDS SPARE BULBS (387). BITE PSEU AND FOUND NO FAULTS. REMOVSDR UPS98527427Gcu · malfunctionedAT VI INTERMITENT LEFT GEN OFF LIGHT ILLUM. LEFT AC BUSS FAILED, RIGHT BUS DID NOT PICK UP LEFT BUS. SHORLTY THERE AFTER THE R AC BUS FAILED. MULTIPLE WARNINGS DISPLAYED. RESET R GEN, R BUS POWER BACK ON. FIRED APU L BUS POWERED. SHORTLY AFTER L BUS POWESDR UPS98527321Bvcu · failedINSPECTION TYPE-N/A, RT ENG FLAMEOUT, RESTART NOT ATTEMPTED FOLLWING NORMAL APPROACH AND LANDING AFTER THRUST REVERSER STOW. PERFORMED BITE TEST PROCEDURE PER MM 75-32-OOP201, FOUND RT ENG BVCU FAULTS. REPLACED BVCU FLT CREW RAN ENG GROUND IDLE. CHECK PERFOSDR UPS98527245Beam · brokenINSPECTION TYPE-N/A ON WALKAROUND, FOUND RT I/B AFT FLAP JAMMED AND RT I/B BELLCRANK SPROCKET BEAM ASSY BROKEN. FOUND LEFT I/B FLAP BELLCRANK SPROCKET BEAM ASSY BROKEN. REMOVED AND REPLACED LEFT I/B BELLCRANK BEAM ASSY PER M/M 27-51-13, (P/N 113N2363-1) FLAPSDR UPS98527176Seat Track · corrodedINSPECTION TYPE-C, CORROSION ON SEAT TRACK AT BS 1180 LBL 45 WL 208 AROUND NUT PLATES. REMOVED CORRODED SEAT TRACK FROM BS 1180 TO 1320 AND INSTALLED NEW SEAT TRACK FROM BS 1180 TO 1320. ALL WORK DONE IAW SRM 51-40-02.SDR UPS98527178Beam · corrodedINSPECTION TYPE-C, CORROSION ON LONGITUDINAL BEAM BS 1040 TO 1076 LBL 45, WL 208 AROUND NUT PLATES. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM 53-00-51. REMOVED AND REPLACED LONGITUDINAL BEAM IAW SRM 51-40-02.SDR UPS98527177Beam · corrodedINSPECTION TYPE-C, CORROSION ON LONGITUDINAL BEAM BS 900 TO 1040 AROUND NUT PLATES, LBL 45, WL 208. REMOVED CORROSION FOUND TO BE OUT OF LMITS PER SRM 53-00-51. REMOVED AND REPLACED LONGITUDINAL BEAM PER SRM 51-40-02, EO 757-53-0048.SDR UPS98527086Sequence Valve · malfunctionedINSPECTION TYPE-N/A, GEAR DISAGREE DISPLAYED WITH GEAR HANDLE UP. ALSO, EICAS GEAR DOOR DISPLAYED. DOORS AND GEAR AMBER LIGHTS ILLUM, ALL GREEN DN LGTS EXTIN. THERE WAS A VIBRATION, RECYCLED THE GEAR, THE GEAR CYCLED SLOWLY AT 250 KNOTS. REMOVED AND REPLACSDR UPS98526992Sequence Valve · failedINSPECTION TYPE-N/A, NOSE GEAR FAILED TO RETRACT. REMOVED AND REPLACED NOSE SEQUENCE VALVE IAW B757 MM32-34-05. CLEANED AND LUBED NOSE GEAR RETRACT LINKAGE AND GEAR BUSHINGS PREFORMED NOSE GEAR RETRACTION TEST PER MM 32-34-00. A 21 SECOND RETRACT TIME, SYSTSDR UPS98526839Temp Bulb · malfunctionedBURNING SMELL IN COCKPIT WITH LEFT PACK OPERATING. SMELL GOES AWAY WITH RT PACK ONLY OPERATING. REMOVED AND REPLACED LEFT PRE-COOLER OUT TEMP BULB. OPERATED PACK WITH LEFT ENGINE NO SMELL NOTED.SDR UPS98526604Engine · vibrationNR 2 ENG VIB INDICATOR WENT TO 5.0 YELLOW RANGE ON CLIMB-OUT LEVELED OFF POWER TO IDLE, VIB WENT TO 2.8 - 4.3 FLUCTUATING. ENG SHUT DOWN. RETURN TO PIE. AWAITING PARTS, USED A/C 707 TO PICK UP LOAD. VISUAL CK OF INLET AND EXHAUST AND CHIP DETECTORS OK. MOSDR UPS98526556Switch · failedINSPECTION TYPE-N/A, EMER LIGHT OVER MAIN ENTRY DOOR ON WHEN SW IS OFF. FOUND BAD SWITSH ASSY. REMOVED AND REPLACED EMER LIGHT SWITCH ASSY IAW MM 33-50, OPS CHECK NORMAL.SDR UPS98526544Idg · failedINSPECTION TYPE-N/A, LEFT GEN FAILED. EICAS MSG L GEN DRIVE DISPLAYED. GEN DRIVE LIGHT ILLUM. GEN DRIVE DISCONECTED, RIGHT GEN WAS DEFERRED. FOUND FILTER BYPASS POPPED AND METAL CHIPS IN FILTER. REPLACED LT IDG (P/N 727792K), (S/N A1120) OFF, (S/N A1004) SDR UPS98526508Card · malfunctionedFIRE WARNING LIGHT ILLUMINATED W/NO OTHER AURAL WARNING. UNABLE TO GET LIGHT TO EXTINGUISH. REMOVED AND REPLACED AFLOTS CARD NR 3, NR M10400 IAW MM 26-10-01 PG 401. OPS CHECK OK, S/N OFF DO9521 ON D10064 P/N ON AND OFF 285N0028-36.
Back to Boeing 757-24APF