Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS98526456Light Panel · malfunctionedINSPECTION TYPE-P/F, EXIT LIGHTS COME ON WHEN SWITCH IS IN THE OFF POSITION. NO GROUND PWR ON A/C AND BATTERY SWITCH IS OFF. REMOVED AND REPLACED EMERGENCY LIGHT PANEL.SDR UPS98526141Bulb · failedINSPECTION TYPE:DAIL EXTERIOR EMERGENCY EXIT LIGHT BELOW CREW ENTRY DOOR INOP. RELAMPED, FUNCTION CHECK NORMAL.SDR UPS98525954Support · crackedINSPECTION TYPE-N/A, AFTER REMOVING NR 1 PIT BULKHEAD WALL AND FLOOR ANGLE, FOUND FLOOR SUPPORT BEAM CRACKED. REPAIRED FLOOR SUPPORT BEAM IAW SRM 51-70-11.SDR UPS98525378Elect Eng Cntrl · failedINSPECTION TYPE-N/A ON SHORT FINAL, RT ENG FAILED. EPR REMAINED AT 1.0. N1 AND N2 WERE FROZEN, EGT 450C, AT ALL THRUST LEVER SETTINGS. ENG WAS NOT SHUT DOWN. ENG WENT TO FAIL-SAFE FLT IDLE POSITON. ENG RUN ON PRI AND SEC CHANNEL IN LGB WAS NORMAL. EEC WASDR UPS97525366Window · lack of lubeINSPECTION TYPE-N/A, CAPTS L2 WINDOW LOCK HANDLE VERY STIFF TO OPERATE. CLEANED AND LUBED L2 WINDOW, OPS CHECKS NORMAL NOW IAW MM 56-11-02.SDR UPS97525361Air Distribution · odorINSPECTION TYPE-N/A, ON TAKEOFF FROM ABY HAD A SLIGHT SMELL OF ELEC, SMOKE. HOWEVER HAD NO SMOKE IN COCKPIT. CHECK FWD AND MAIN E AND E COMPT FOR ELEC SMOKE SMELL, NONE NOTED. CHECK ACFT FOR LIGHTINING STRIKE, NO DAMAGE FOUND.SDR UPS97525358Window · lack of lubeINSPECTION TYPE-N/A, F/O WINDOW DIFFICULT TO UNLATCH. ADJUSTED WINDOW IAW M/M 56-11-01. FOUND INSPECTION PUTTY ON ALL 4 LATCH CAMS IN A SOLID STATE. CLEANED AND RE-LUBED LATCH CAMS, WINDOW OPS CKS OK.SDR UPS97525357Window · lack of lubeINSPECTION TYPE-N/A, CAPT WINDOW DIFFICULT TO UNLATCH. ADJUSTED WINDOW IAW M/M 56-11-02 AND FOUND INSPECTORS PUTTY ON ALL 4 PIN THAT WAS IN A SOLID STATE. CLEANED APPLIED LUBE WINDOW CK'D OK.SDR UPS97525356Window · lack of lubeINSPECTION TYPE-N/A, CAPT WINDOW DIFFICULT TO UNLATCH. REMOVED DEBRIS FROM LOWER LATCH AND LUBRICATED, WINDOW LATCH OPS CHECKS GOOD PER MM 56-11-02 P519.SDR UPS97525340Sliding Window · out of adjustINSPECTION TYPE-N/A, F/O'S SLIDING WINDOW DIFFICULT TO UNLOCK AND CLOSE. ADJUSTED VERTICAL POSITION OF F/O'S SLIDING WINDOW IAW MM 56-11-02. OPS CK NORMAL, OK TO CONTINUE SERVICE.SDR UPS97525200Sliding Window · out of adjustINSPECTION TYPE-N/A, CAPT WINDOW LATCH IS VERY DIFFICULT TO OPEN. ADJ CAPT SLIDING WINDOW IAW MM 56-11-02, CKS GOOD.SDR UPS97525188Hydraulic Line · failedINSPECTION TYPE-N/A, LT HYD QTY DECREASED TO .18, EDP DEPRESSURIZED AND ELECTRIC PUMP OFF. QUANTITY CONTINUED TO DECREASE TO ZERO. ALL GEAR GREEN ON LIGHTS FAILED TO ILLUMINATE WITH GEAR HANDLE DOWN, EICAS MESSAGE, GEAR DISAGREE DISPLAYED. DOORS AMBER LIGHTSDR UPS97525096Pbe · inoperativeINSPECTION TYPE-N/A, PBE HAS NO VACUUM. REMOVED AND REPLACED PBE (P/N 4566M37B-042NM) (S/N E-9653903) OFF, (P/N E-9549117) ON. NEW EXPIRATION DATE JAN-2006.SDR UPS97525072Thrust Levers · bindingAUTOTHROTTLE DISC ON T/O THRUST LEVERS FEEL LIKE A SLIGHT BINDING WHEN OPERATED TOGETHER. WHEN MOVED SEPARATELY, THRUST LEVERS SEEM TO MOVE SMOOTHLY. SUPPLEMENTAL MRR DEFERRED AUTOTHOTTLES AS PER 22-30-1 (MEL) C/W MAINT PROCEDURES AS PER MEL SEE ITEM 2 FOR A/SDR UPS97524773Window · bindingINSPECTION TYPE-N/A, CAPTAINS SIDE WINDOW UNLOCK HANDLE BINDING. ADJUSTED L/2 WINDOW PER MM 56-11-02, OPS CK GOOD.SDR UPS97524751Floorbeam · corrodedINSPECTION TYPE:C MAIN DECK FLOORBEAM UPPER CHORD HAS AREAS OF CORROSION ON UPPER SURFACE BETWEEN BS 990-BS1070 LBL 45 WL 208. CORROSION REWORK OUT OF LIMITS IAW SRM 53-00-51. REPAIRED FLOORBEAM STA 990-1070 LBL 45 WL 208 IAW BF GOODRICH AEROSPACE EWO97-4086SDR UPS97524692Support · crackedINSPECTION TYPE:C4 IN AFT BAY, FLOOR SUPPORT AT STA 1240, LBL 12 IS DAMAGED AND HAS SHEARED FASTENERS. REMOVED DAMAGED SECTION OF FLOOR SUPPORT AND REPLACED SECTION WITH NEW PER SRM 51-70-12, 51-20-01.SDR UPS97524439Strut · reqd serviceINSPECTION TYPE-N/A, EXCESSIVE NOSE STRUT EXTENSION NOTICED AT BLOCK OUT. NOSE WHEEL CAME OFF GRD AT APPLICATION OF BRAKES LOAD RECONFIGURED. NOSE STRUT AIR VOLUME DECREASED TO BRING STRUT WITHIN LIMITS.SDR UPS97524432Latch Handle · out of adjustINSPECTION TYPE-N/A, CAPT'S SLIDING WINDOW RELEASE HANGLE BINDS (LATCH HANDLE). ADJUSTED CAPT'S NR 2 WINDOW CAM BLOCK AS NEEDED PER B757 M/M 56-11-02, OPS CK OK.SDR UPS97524427Control Panel · burnedINSPECTION TYPE-N/A, WXR RAIL MSG ON EHSI FOLLOWED BY SMOKE COMING FROM WX RADAR CONTROL PANEL AND AISLE STAND. REMOVED AND REPLACED WX RADAR CONTROL PANEL (P/N 622-5129-109), NOTED 3 DIODES BURNED INSIDE PANEL.SDR UPS97524453Engine · malfunctionedLEFT ENG LOST THRUST ON FINAL APPROACH. ENGINE SHUT DOWN ON ROLLOUT DUE TO HIGH EGT ON LANDING ROLL. EGT APPROACH 700 DEG. RESTART NOT ATTEMPTED INFLIGHT DUE TO PROXIMITY TO GROUND, THERE WERE NO THRUST LEVER MOVEMENTS. INSPECTED ENG INCLUDING FUEL FILTER SDR UPS97524312Sensor · failedINSPECTION TYPE-N/A, ELECTRICAL FUMES IN COCKPIT AT CRUISE ALTITUDE. EXECUTED EMERGENCY PROC EQUIP OVERHEAT LGT ILLUM ON LANDING STATUS MSG: OVBD EX VAL OPEN. FOUND FLOW DETECT C/B POPPED AND WOULDN'T RESET WITH A FWD EQ EXH FLOW MESSAGE. PLACARDED 21-58-13SDR UPS97524272Battery · dischargedINSPECTION TYPE-N/A, EMER LIGHTS EICAS MSG SWITCH ARMED, NO UNARMED LIGHT ILLUMINATED. EMERGENCY EXIT LIGHT BATTERY PACK REMOVED AND REPLACED AS PER MM 33-51-07, AND OPS CHECKS GOOD.SDR UPS97524023Light · inoperativeINSPECTION TYPE-N/A, EMERGENCY EXIT LIGHT AT CREW ENTRY DOOR INOP. REMOVED AND REPLACED EMERGENCY EXIT LIGHT BATTERY PACK.SDR UPS97523974Computer · malfunctionedINSPECTION TYPE-N/A, LT ENG IFSD DUE TO OIL PRESS LOW. *S/D* REMOVED AND REPLACED LEFT EICAS COMPUTER PER MM 31-41-02 (P/N 622-6540-111) (S/N 1350) OFF, (S/N 3342) ON. OPS CHECK GOOD, BITE CHECKS GOOD.SDR UPS97523823Air Distribution · odorINSPECTION TYPE:N/A, STRONG IRRITATIVE FUMES IN FLT DECK AT SAME TIME AS HYDRAULIC FAILURE. RAN APU AND BOTH ENG FOR AIR TO PACKS AFTER HYD LEAK, REPAIR ITEM 2 ABOVE NO FUMES OR ODOR NOTED.SDR UPS97523822Hyd Line · brokenINSPECTION TYPE:N/A, LEFT HYDRAULIC SYSTEM FAILURE IN FLIGHT. REPLACED BROKEN HYD LINE AND 90 DEG FITTING ON TOP OF LT MAIN GEAR RETRACT CYLINDER, OPS AND LEAK CKS OK.SDR UPS97523184Skin · dentedINSPECTION TYPE:C, FUSELAGE DENT 8 INCHES AFT OF LT AOA SENSOR AND 48 INCHES BELOW L3 WINDOW. TRANSFERRED FROM DMI NR 129305, TRANSFERRED FROM LP 822020 ITEM 1. ACCOMPLISHED ALL WORK PER B757-5750-9296B.SDR UPS97523183Skin · crackedINSPECTION TYPE:C, LT WING O/B FLAP O/B LOWER SKIN PANEL (P/N 113N 3600-19) WAS CRACKED AT WBL 560. ACCOMPLISHED ALL WORK PER EWO NR 97-4027 AND UNDER ENGINEERING FILE NUMBER B757-57-0114SDR UPS97523139Skin · crackedINSPECTION TYPE:C, LT WING O/B FLAP O/B LOWER SKIN PANEL (P/N 113N3600-19) IS CRACKED AT WBL 560.0. ACCOMPLISHED ALL WORK PER EWO NR 97-4027 AND UNDER ENGINEERING FILE NUMBER B757-57-0114.SDR UPS97523136Skin · dentedINSPECTION TYPE:C, FUSELAGE DENT 8 AFT OF LT AOA SENSOR AND 48 BELOW L3 WINDOW TRANSFERRED FROM DMI NR 1 129305 (TRANSFERED FROM LP 822020 ITEM 1). ACCOMPLISHED ALL WORK PER B757-5750-9296B.SDR UPS97523185Skin · dentedINSPECTION TYPE:C, LEFT HAND SIDE FUSELAGE 2 DENTS 18 INCHES AFT OF AOA SENSOR BS 245 AND 253, WL 190, SEC 41. ALL WORK ACCOMPLISHED PER EO B757-5750-9296B.SDR UPS97523137Skin · dentedINSPECTION TYPE:C LEFT HAND SIDE FUSELAGE 2 DENTS 18 INCHES AFT OF AOA SENSOR BS 245 AND 253, WL 190, SEC. 41 ALL WORK ACCOMPLISHED PER E.O B757-5750-9296BSDR UPS97522598Battery · dischargedINSPECTION TYPE-N/A, MAIN ENTRY DOOR EMERGENCY LIGHT INOP. REPLACED BATTERY ASSY EXIT LIGHT, OPS CHK GOOD.SDR UPS97522371Engine · failedINSPECTION TYPE-N/A, AIR TURNBACK DUE TO SMOKE IN COCKPIT AND MAIN CARGO FIRE WARNING. LEFT ENGINE LOST 8 QTS IN 16 MIN OF FLIGHT AND 45 MIN OF BLOCK TIME. CLIMBING THROUGH 12,000 FT MAIN CARGO FIRE WARNING CAME ON AND SMOKE ENTERED COCKPIT. ACCOMPLISHED CHSDR UPS97522219Fuse Pin · crackedINSPECTION TYPE:1C, FUSE PIN REPLACEMENT RIGHT HAND PYLON. REMOVED FUSE PIN, FOUND BOTH TO BE CRACKED, REPLACED BOTH FUSE PINS.SDR UPS97522149Auto Pilot · malfunctionedINSPECTION TYPE-N/A, AT 13,00O 2 PAK, SPEEDBRAKES GRADUALLY DEPLOYED NORMAL PITCH DOWN F/ DESCENT BUT PITCHDOWN FORCE INCREASED SUBSTANTIALLY WITHOUT PILOT INPUT. NOSE DROPPED ALMOST 25 DEG NOSE DOWN AND A/S INCREASED TO 340 KTS PASSING THROUGH 1,000 FT WITH SDR UPS97522076Bracket · crackedINSPECTION TYPE-2C, RIGHT WING OUTBOARD FLAP MAIN AT OUTBOARD END AFT ANGLE CRACKED. REMOVED CRACKED ANGLE BRACKET, FABRICATED NEW BRACKET AND INSTALLED THE ANGLE BRACKET IAW SRM 51-20-01, 51-30-01, 51-40-02.SDR UPS97521925Cover · crackedFOUND 1.375 INCH CRACK IN NOSE GAP COVER ASSY, LEFT SIDE ON INBD SIDE OF ASSY BOTTOM OF LEADING EDGE. INSTALLED REPAIR TO LT WING FIXED L/E PER EO B757-5740-9005A.SDR UPS97521837Air Distr · odorINSPECTION TYPE-N/A, CREW REPORTED SMOKE SMELL IN COCKPIT AND PERFORMED QRH AIR COND CHECKLIST. RAN BOTH PACKS AND CHECKED FOR LEAKS AND SMELLS, NONE NOTED. PERFORMED BITE CHECKS ON BOTH PACK CONTROLLERS, PRESSURE CONTROLLERS AND EQUIPTMENT COOLING SYSTEM, NSDR UPS97522176Fuse Pin · shatteredINSPECTION TYPE-C, S3 MID SPAR FUSE PIN SHATTERED RT PYLON. FOUND DURING EO B757-5440-6874-A ACCOMPLISHED FUSE PIN REPLACEMENT IAW EO B757-5440-0431 (WARRANTY EOE 1103).SDR UPS97521813Hose Assy · rupturedINSPECTION TYPE-N/A, AIR TURNBACK LT HYD QTY DECREASED TO 0 AND SYSTEM PRESS LIGHT ILLUMINATED. EICAS MSG LT HYD PRESSURE DISPLAYED. REMOVED AND REPLACED FLEX LINE.SDR UPS97521956Audio Panel · malfunctionedINSPECTION TYPE-N/A, DESCENDING THROUGH FL180 SMELLED SMOKE IN COCKPIT, ELECT FLO'S INTERCOM WOULD NOT XMIT ON NR 1, ON NR 3 VHF. ON INTERCOM RECEIVES OK. REMOVED, INSP AND REINSTALLED F/O'S AUDIO PNL AND SPKR. OPS CKD F/O'S VHF AND INT PHN SYS WORKS NORMALSDR UPS97521808Light · inopINSPECTION TYPE-N/A, FAILED TO GET LEFT MAIN GEAR LIGHT ON ARRIVAL AT DFW. SUCCESSFUL LANDING WITH FIRE AND RESCUE EQUIPTMENT STANDING BY. RELAMPED WITH CORRECT BULBS TWO EACH, OPS TEST NORMAL.SDR UPS96521785Light · inoperativeINSPECTION TYPE-N/A, EMERGENCY EXIT LIGHTS FAIL TO TEST ON PDC. EMERGENCY EXIT LIGHTS POWER SUPPLY AND BATTERY REMOVED AND REPLACED AS PER MM 33-51-07 AND OPS CHK GOOD, (P/N 33-50-190-320) ON, (P/N 5283T014-3) OFF, (S/N FTW Z42114) ON, (S/N 39161).SDR UPS96521481Skin · delaminatedRT AILERON DELAMINATED ON OUTBOARD END TOP OF AILERON. REPAIRED RT AILERON OUTBOARD EDGE IAW EO B757-5760-8740.SDR UPS96521383Cooling Fan · defectiveINSPECTION TYPE-N/A, STRONG ELECTRICAL BURNING SMELL FROM UNDER FORWARD PANEL BOTH SIDES AFTER 1HR 30M FLT TIME. UNABLE TO DETERMINE CAUSE. FOUND NR 1 FD EQUIP COOLING SUPPLY FAN BAD. DEFERRED PER MEL 21-58-04.SDR UPS96521346Engine · hi oil consumptINSPECTION TYPE-N/A, LT ENGINE WHEN LT PACK SELECTED ON, OIL FUMES CAME THROUGH PACK, VERY STRONG FUMES, OIL ON TAXI AND T/O HIGH OIL CONSUMPTION. REMOVED AND REPLACED LT ENGINE.SDR UPS96521303Sequence Value · failedINSPECTION TYPE N/A, NOSE GEAR GREEN DOWN LIGHT FAILED TO ILLUMINATE WITH GEAR HANDLE DOWN. EICAS MESSAGE GEAR DISAGREE AND GEAR DOORS DISPLAYED. DOORS AND GEAR AMBER LIGHTS ILLUMINATED. INDICATIONS WERE NORMAL AFTER ALTERNATE GEAR EXTENSION. TROUBLESHOT PSDR UPS96521278Power Supply · inoperativeINSPECTION TYPE-N/A, EMERGENCY EXIT LIGHTS INOP. REMOVED AND REPLACED POWER SUPPLY AS PER MM 33-51-07, OPS CK'D GOOD.
Back to Boeing 757-24APF