Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS96521233Skin · damagedINSPECTION TYPE-3C, FIBER IS DAMAGED ON THE RT ELEVATOR LOWER TRAILING EDGE 68 INCHES OUTBOARD FROM INBOARD END. REPAIRED PER SRM 55-20-01, 51-70-04, 51-20-05 AND SRM 51-40-02.SDR UPS96521199Engine · high oil consmptACID SMELL IN COCKPIT IN-FLIGHT. SAME INTENSITY NOTICED WITH EITHER ACM OPERATING. ENG ANTI-ICE WAS USED FOR SHORT DURATION. DID NOT NOTICE SMELL ON GROUND WITH ACM'S RUNNING WITH BLEED SOURCE. BURNS EYES AND THROATS. NR 2 ENG REQUIRES CHANGING DUE TO HIGSDR UPS96521136Fairing · damagedINSPECTION TYPE-N/A, DECLARED EMERGENCY DUE TO SUSPECTED LIGHTENING STRIKE AND INDICATED DECREASING OIL QUANTITY IN RT ENG OIL INDICATION RETURNED TO NORMAL LEFT WING O/B FLAP I/B FAIRING DAMAGED. REF D 115519 LEFT WING AFT FLAP I/B FAIRING DAMAGED ON O/B SIDSDR UPS96521130Skin · delaminationINSPECTION TYPE-3C, RIGHT WING O/B MAIN FLAP HAS AREAS OF DELAMINATION ON I/B END UPPER SURFACE. REPAIRED RT WING O/B MAIN FLAP UPPER SURFACE. ALL WORK DONE IAW SRM 57-53-01 AND SRM 51-70-07.SDR UPS96521120Battery Pack · dischargedINSPECTION TYPE N/A, EMER LIGHTS WEAK. REPLACED BATTERY PACK PER MM 33-51-07.SDR UPS96521095Sequence Vlv · defectiveINSPECTION TYPE N/A, ON APPROACH NOSE GEAR FAILED TO EXTEND AND GEAR DISAGREE MSG DISPLAYED, ALT GEAR EXTEND SELECTED AND GEAR DEPLOYED. FERRIED A/C TO SDF. REMOVED AND REPLACED NOSE GEAR DOOR SEQUENCE VALVE PER MM 32-34-05. PERFORMED TEST OF NOSE GEAR EXTESDR UPS96521036Floor Panel · corrodedINSPECTION TYPE-3C, CORROSION ON FLOOR PANEL ON LOWER CENTER OF COCKPIT. REMOVED CORROSION AND FOUND OUT OF LIMITS, FABED NEW PANEL AND INSTALLED. ALL WORK PER SRM 51-40-02, 51-10-01, 53-00-51, 51-30-01 AND 53-00-50.SDR UPS96520951Skin · delaminatedINSPECTION TYPE-3C, WHILE WORKING EO B757-5760-6676B FOUND AREA OF DELAM AT INBOARD FORWARD CORNER OF RIGHT WING AILERON LOWER CONDUCTIVE FRAME. REPAIRED RT AILERON LWR SURFACE IAW SRM 51-31-01.SDR UPS96520826Fuse Pin · crackedOUTBOARD FUSELAGE ON NR 2 ENGINE PYLON CRACKED. INBOARD AND OUTBOARD FUSELAGE PINS REPLACED. COMPLIED WITH EO B757-5440-0431-1 APPENDIX F, COMPLIED T/C 5001 (PW) REMOVAL AND INSTALLATION OF NR 2 (RT) ENGINE.SDR UPS96520811Skin · puncturedINSPECTION TYPE-N/A, ON T/O ROLL HEARD SOUND, LIKE A CONTAINER WAS ROLLING TOWARD REAR OF ACFT. REJECTED T/O AND RETURNED TO RAMP. UPON MAINT INSPECTION FOUND 7,000 LB BALLEST PALLET IN POSS 15 AND HOLE IN ACFT SKIN APROX 7 BY 24. RT AND LT STA 1681 AND 170SDR UPS96520677Power Supply · inoperativeINSPECTION TYPE N/A, EMER EXIT LIGHTS DO NOT ILLUMINATE WHEN TURNED ON. REMOVED, REPLACED AND TESTED EMER EXIT LIGHT PWR SUPPLY PER MM 33-51-07.SDR UPS96520618Floor Beam · corrodedINSPECTION TYPE: C. FLOORBEAM BS 310.5, LBL 25-30, FOUND TO HAVE CORROSION AROUND NUT CLIP. REMOVED CORROSION BY CUTTING OUT DAMAGE AREA. FABRICATED REPAIR PARTS. INSTALLED REPAIR PARTS. ALODINED AND PRIMED REPAIR IAW EWO 9 6-4068.SDR UPS96520615Spoiler · water damageINSPECTION TYPE 3C, NR 7 SPOILER REQUIRES REMOVAL AND REPLACEMENT DUE TO CLASS 4 WATER DAMAGE. REMOVED AND REPLACED NR 7 SPOILER IAW MM 27-61-01. FUNCTIONAL TEST GOOD ON NR 7 SPOILER IAW MM 27-61-00.SDR UPS96520614Spoiler · water damageINSPECTION TYPE 3C, NR 12 SPOILER REQUIRES REMOVAL AND REPLACEMENT DUE TO CLASS 4 WATER DAMAGE. REMOVED AND REPLACED NR 12 SPOILER IAW MM 27-61-01. FUNCTIONAL CHECKED GOOD IAW MM 27-61-00.SDR UPS96520613Rib · crackedINSPECTION TYPE 3C, WHILE WORKING ROLLER RIB EO B757-5750-2093-1 SMALL CRACK MEASURING .3125 INCH LONG BY .125 INCH WIDE WAS DICOVERED 30.625 INCHES INBD FROM NEW ROLLER RIB AND 12.5 INCHES FORWARD OF TRAILING EDGE LEFT SIDE INBD AFT FLAP. REPAIRED PER SRM 51SDR UPS96520612Spoiler · water damageINSPECTION TYPE 3C, NR 1 SPOILER REQUIRES REMOVAL AND REPLACEMENT DUE TO CLASS 4 WATER DAMAGE. REMOVED AND REPLACED NR 1 SPOILER IAW MM 27-61-01. FUNCTIONAL CHECK GOOD IAW MM 27-61-00.SDR UPS96520406Switch · brokenINSPECTION TYPE N/A, EMERGENCY LIGHTS UNARMED LIGHT IS BROKEN. REMOVED AND REPLACED UNARMED SWITCH PANEL ASSY, OPS CKD OK. (P/N 233N3219) (S/N D00005) ON, (S/N D00036) OFF.SDR UPS96520396Power Supply · inoperativeINSPECTION TYPE: N/A. ON PRE-DEPARTURE CHECK, THE EMERGENCY EXIT LIGHTS FAILED TO ILLUMINATE WITH THE SWITCH IN THE ON POSITION. REPLACED THE BATTERY ASSY, POWER SUPPLY.SDR UPS96520402Floor · corrodedINSPECTION TYPE: C. CORROSION ON CONTROL CABIN FLOOR AT BS STA 255-297 FROM BL ZERO-RBL 10, BL ZERO-BL 15 AND LBL 15-LBL 30. REMOVED CORROSION PER SRM 51-20-01. FOUND TO BE OUT OF LIMITS PER SRM 53-00-01 AT BS 297, LBL 15 TO LBL 30. REPAIRED PER SRM 51-70SDR UPS96520206Gear Ind Lght · defectiveCREW HAD ON GEAR DOWN AND LOCKED INDICATION. FOUND THE CAP ASSEMBLY OF THE INDICATOR LIGHT WOULD NOT LOCK INTO THE BASE, THIS CAUSED THE BULB TO NOT WORK. REPLACED NOSE GEAR INDICATION LIGHT ASSEMBLY NR 434-674-1033-2205, CHECKED OP AND OPS OK.SDR UPS96520239Bulb · failedINSPECTION TYPE: IN CABIN, EMERGENCY EXIT LIGHT ASSY HAS SEVERAL BURNED OUT BULBS. RELAMPED ASSY. - TESTED NORMALLY.SDR UPS96520102Pressure Switch · intermittentINSPECTION, INFLIGHT SHUTDOWN OF LT ENGINE DUE TO EICAS MESSAGE LT ENG OIL FILTER, ALL OTHER ENG INDICATION NORMAL. C/W F/M 79-21-00 FIG 104 REMOVED MAIN ENG OIL FILTER AND CHECKED ALL MAGNETIC CHIP DET, NO CONTAMINATION FOUND ON DETECTORS. INSTALLED NEW FILSDR UPS96520025Radome · failedINSPECTION, A/C NOSE RADOME BUCKLED/CAVED IN AT UPPER MIDDLE PORTION. APPEARS TO HAVE BEEN RADOME STRUCTURAL FAILURE. NO EVIDENCE OF BIRD OR LIGHTNING STRIKE. *S/D* REPLACED RADOME IAW MM 53-12-01.SDR UPS96520205Bulbs · failedCABIN EMERGENCY EXIT LIGHT ASSEMBLY HAS SEVERAL BURNED OUT BULBS. RELAMPED ASSEMBLY, TEST NORMALLY.SDR UPS96520187Light · inoperativeINSPECTION TYPE: CABIN EMERGENCY EXIT LIGHTS BURNED OUT. RELAMPED ASSEMBLY - TEST NORMAL.SDR UPS96520019Emer Exit Window · popped outINSPECTION TYPE: FIRST OFFICER'S EMERGENCY EXIT WINDOW HANDLE POPPED PUT APPROXIMATELY 3 FEET AFTER ENGINE SHUTDOWN. REQUIRES EXCESSIVE FORCE TO PULL HANDLE OUT ON GROUND. SUPPLEMENTAL MRR: INSTALLED NEW WINDOW LATCH STILL STIFF. RFD MX TO REMOVE WINDOW ASDR UPS96505890Skin · crackedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED LEFT OUTBOARD FLAP, OUTBOARD LOWER AFT SKIN IS CRACKED. REMOVED AND REPLACED CRACKED SKIN PANEL WITH FABRICATED PANEL, INSTALLED PER SRM 51-40-02, EO 757-57-0073.SDR UPS96505889Bracket · crackedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED RIGHT WING OUTBOARD FLAP OUTBOARD SKIN SUPPORT BRACKET IS CRACKED. REMOVED AND REPLACED WITH FABRICATED BRACKET, INSTALLED PER SRM 51-30-01, 51-40-02, M/M 20-10-22.SDR UPS96505888Frame · crackedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED AFT CARGO BAY STA 1320 BETWEEN STR 25R AND 26R FRAME IS CRACKED. CUT OUT DAMAGE AND REPAIRED PER SRM 51-70-11.SDR UPS96505827Skin · crackedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED RT FRONT WING O/B FLAP MOST O/B SKIN PNL TOP IS CRACKED. REMOVED AND FABRICATED NEW SKIN PNL AND INSTALLED PER SRM 57-53-01, 51-40-02, 51-40-08, 51-40-05 AND MM 51-20-10.SDR UPS96505826Angle · crackedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED FWD CARGO COMPARTMENT AFT BULKHEAD LOWER SUPPORT ANGLE STA 845 IS DENTED AND CRACKED. REMOVED AND FABRICATED NEW ANGLE AND INSTALLED PER SRM 51-40-2, 51-20-01, 51-30-01 AND MM 20-10-22.SDR UPS96505672Floor Beam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED CORROSION FOUND ON FLOOR BEAM BS 278 WL 200 RBL 3 AND LBL 11. REPAIRED FLOOR BEAM UPPER CHORD PER UPS EO 757-53-0030.SDR UPS96505669Wire · brokenPRIOR TO T/D, SPARKS AND SMOKE CAME FROM STANDBY POWER SECTION OF P11 PNL. THE STANDBY BUS ON P6 POPPED, ALL STANDBY A/C POWERED ITEMS WERE LOST. FOUND WIRE BROKEN CAUSED BY INTERFERENCE WITH GROUND STD AT AP .0011. REPAIRED AS REQUIRED.SDR UPS96505671Access Door · damagedUPON DEPARTURE, EXPERIENCED VIBRATION ABOUT THE SAME TIME FLAPS WERE RETRACTED. VIBRATION CONTINUED UNTIL SEVERAL MINUTES LATER, THEN STOPPED. REMOVED AND REPLACED PNUE ACCESS DOOR IN LT A/C BAY DOOR.SDR UPS505572Skin · crackedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED RT I/B MAIN FLAP HAS 5 CRACK'S 6 INCHES LONG ON UPPER SURFACE OF I/B TRAILING EDGE. REMOVED AND REPLACED MAIN FLAP IAW MM 27-51-02, 27-51-12, AND 27-51-13.SDR UPS505571Support · crackedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED AFT BULK CARGO COMP LT FLOOR TO SIDEWALL SUPPORT CRACKED AT BS 1465. REPAIRED CRACK IAW SRM 51-70-13.SDR UPS5005545Wxr Contl Pnl · shortedCREW REPORTED, WXR FAIL DISPLAYED ON HSI DURING INFLIGHT WXR TEST. ELECTRICAL FUMES NOTED, TEST SECURED. FUMES DISSAPATED, ASSIGNED M-106357 PER MEL 34-43-1 AND INSTALLED PLACARD PER MEL.SDR UPS505369Shutoff Valve · inoperativeCREW REPORTED, RT PACK SURGE, OIL SMELL IN COCKPIT. REPLACED RT PACK FLOW CONTROL AND SHUTOFF VALVE PER MM 21-51-01.SDR UPS505371Bracket · crackedWHILE IN FOR AN SI CHECK, MAINTENANCE REPORTED, LEFT O/B MAIN FLAP, O/B CLOSURE RIB EXTERNAL AFT BRACKET CRACKED. FABRICATED AND INSTALLED NEW BRACKET IAW SRM 51-40-02, 51-30-01.SDR UPS505225Engine · flame-outCREW REPORTED, RT ENGINE FLAMED-OUT ON APPROACH. REMOVED AND REPLACED RT ENGINE.SDR UPS5O5147Eel Diode Card · inoperativeEMERGENCY UNARMED LIGHT MODULE ONLY HAD ONE BULB ILLUMUMINATE. REMOVED AND REPLACED DIODE CARD AND LENS ASSEMBLY. OPS CHECK GOOD.SDR UPS505126Skin · delaminatedWHILE ON GROUND, MAINTENANCE FOUND NUMBERS 5 AND 8 SLATS WERE DELAMINATED.SDR UPS505120Ind Bulb · failedCREW REPORTED ON GEAR EXTENSION AT PBI, LEFT MAIN GEAR LIGHT DID NOT ILLUMINATE. GEAR DISAGREE EICAS MSG ILLUMINATED. RAN APPROPRIATE CHECK LISTS AND PERFORMED NORMAL LANDING. PBI CFR PINNED LEFT MAIN GEAR AFTER LANDING. RELAMPED LT GEAR LIGHT PER MM 33-16-SDR UPS505121Fuse Pin · crackedWHILE ON GROUND, MAINT FOUND RT ENGINE O/B FUSE PIN CRACKED. REMOVED AND REPLACED BOTH FUSE PINS ON RT ENG IAW EO B757-440-0431. ENG OPS AND LEAK CKS GOOD.SDR UPS205026Rib · crackedWHILE IN FOR C-CHECK, MAINTENANCE FOUND LEFT WING INBD MAIN FLAP HAS CRACKED RIB IN AFT COVER OF THE MAIN OUTBOARD END UPPER SKIN LOWER SURFACE. REMOVED CRACKED RIB FROM L/W INBD FLAP, FABRICATED NEW RIB FROM STOCK EXTRUSION, INSTALLED ON L/W INBD FLAP. ALL SDR UPS205025Tee Angle · crackedWHILE IN FOR C-CHECK, MAINTENANCE FOUND RT WING INBD MAIN FLAP AFT COVE OUTBOARD END HAS CRACKED TEE ANGLE ON THE LOWER SURFACE OF THE UPPER SKIN, AS MARKED. REPLACED TEE ANGLE PER SRM 51-40-02.SDR UPS205024Bracket · crackedWHILE IN FOR C-CHECK, MAINTENANCE FOUND LEFT WING OUTBOARD MAIN FLAP BRACKET ON OUTBOARD EDGE IS CRACKED. REMOVED CRACKED BRACKET FROM O/B EDGE OF L/W O/B MAIN FLAP, FABRICATED NEW BRACKET AND INSTALLED. ALL WORK DONE PER SRM 51-30-01, 51-40-02, 51-20-01, ANSDR UPS505075Battery Pack · dischargedWHILE ON GROUND, MAINTENANCE FOUND EMERGENCY EXIT LIGHT INOP. REPLACED BATTERY PACK, OPS OK.SDR UPS504926Ind Light · failedCREW REPORTED LEFT GEAR INDICATION INOP - 60 AROUND PERFORMED - MAINTENANCE CONTACTED. EQUIPMENT CALLED FOR - COORDINATED APPROACH END OBSERVER WHICH CONFIRMED GEAR APPEARED DOWN - LANDING MADE WITHOUT INCIDENT. MAINTENANCE RE-LAMPED LEFT MAIN GEAR DOWN LIGSDR UPS504881Manifold Tube · chafedWHILE ON GROUND, MAINTENANCE FOUND THRUST REVERSER INTERIM REPAIR - ALTERNATE FASTENER TO ELIMINATE FUEL SPRAY NOZZLE MANIFOLD TUBE WEAR. MAINTENANCE REPAIRED IAW UPS E.O. B757-7830-7539A.
Back to Boeing 757-24APF