Boeing 767-223
Service difficulty reports · 2,039
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA994004Stringer · corrodedAFW - STRINGER 35L AT APPROX STATION 1400 WAS CORRODED AT PRODUCTION SPLICE. CUT AND REMOVE CORRODED SECTION. ALODINE AND PRIME ALL BARE ALUMINUM. INSTALL NEW SPLICE AND REPAIR PER SKETCHES. (M)SDR AALA994003Keel Beam · corrodedAFW - LEFT KEEL BEAM HAS CORROSION REMOVAL. REMOVED ALL CORROSION AND REFINISH THE SURFACE PER SRM. INSTALL SHIMS/WASHERS BETWEEN THE FLANGE AND THE RETAINER TO PREVENT FASTENER PULL UP AND SEAL THE AREA WITH BMS5-95. (M)SDR AALA984266Floorbeam · corrodedAFW - FLOORBEAM AT STATION 347 HAS CORROSION REMOVAL. ALODINE ALL BARE ALUMINUM SURFACES. FINISH BLENDED AREAS WITH 2 COATS PRIMER. FILL WITH BMS5-95. (M)SDR AALA982239Wire · shortedORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS FROM SEAT 31H TO AFT OF AIRCRFT INOPERATIVE. REPAIRED WIRE IN EMERGENCY EXIT SEAT LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA984264Beam · corrodedAFW - FOUND AREAS ON BEAM CORRODED. REMOVED ALL CORROSION. ALODINE AND APPLY 2 COATS PRIMER. FILL BLENDS WITH SEALANT. FABRICATE REPAIR STRAP. INSTALL STRAP. (M)SDR AALA984262Frame · gougedAFW - FUSELAGE FRAME J-CAP AT STATION 478 HAS GOUGE. BLENDOUT CORROSION. VISUALLY INSPECT TO ENSURE NO CRACKS AT BLENDED AREA. ALODINE AND APPLY 2 COATS PRIMER. (M)SDR AALA984261Frame · corrodedAFW - FORWARD CARGO FRAME T-CAP AT STATION 676 LBL 20 HAD CORROSION BLENDED ON TOP AND BOTTOM SURFACES. BLEND OUT ALL CORROSION AND FINISH THE BLENDED AREA. FABRICATE A REPAIR ANGLE. (M)SDR AALA984267Floorbeam · corrodedAFW - FLOORBEAM AT STATION 287 RBL 55 HAD CORROSION BLENDED ON AFT FLANGE. FABRICATE STRAP, ALODINED ALLUMINUM SURFACES. FINISH BLEND AND REPAIR PARTS WITH PRIMER. INSTALL STRAP WET WITH SEALANT. (M)SDR AALA984265Floorbeam · corrodedAFW - FLOORBEAM AT STATION 347 HAD CORROSION BLENDED. FABRICATE REPAIR STRAP. ALODINE ALL BARE ALUMINUM SURFACES. FINISH BLENDS AND REPAIR PARTS WITH 2 COATS PRIMER. FILL BLENDS WITH BMS5-92. INSTALL STRAP WET WITH SEALANT. (M)SDR AALA984263Frame · corrodedAFW - FUSELAGE FRAME AT STATION 610, J-CAP HAS CORROSION REMOVAL ON LOWER SURFACE. BLENDOUT, CORROSION ENSURE NO CRACKS ALODINE AND APPLY 2 COATS PRIMED. FILL WITH SEALANT. (M)SDR AALA984259Floorbeam · corrodedAFW - FLOORBEAM AT STATION 1480 HAS CORROSION REMOVAL ON UPPER SURFACE. BLENDED OUT CORROSION, ALODINE AND PRIMED ALL BLENDS AND REPAIR PARTS WITH 2 COATS BMS 10-11 PRIMED. FILLED BLENDS WITH BMS 5-95 SEALANT. INSTALLED 301 1/2H STAINLESS STEEL STRAP WET WISDR AALA984247Splice · corrodedAFW - STRINGER 32L HAD SECTION REMOVED DUE TO CORROSION NEAR A PRODUCTION SPLICE AT STATION 434. REMOVE CORRODED PIECE OF STRINGER. REPLACE WITH SIMILAR LONGER SPLICE WITHOUT JOGGLE. ALODINE AND APPLY 2 COATS PRIMER SURFACE SEAL WITH BMS5-95. (M)SDR AALA984244Frame · corrodedAFW - J-CAP AT STATION 456 ABOVE STRINGER 332 AND J-CAP AT STATION 478 ABOVE LBL 43 HAVE CORROSION. BLEND CORROSION. PLUG EXISTING NUTPLATE. ALODINE ALL BARE ALUMINUM. PLACED ANGLE IN REPAIR AREA TO ENSURE FIT. INSTALL NUTPLATES, SHIM ALL GAPS, FILL ALL VSDR AALA984240Floorbeam · corrodedAFW - FLOORBEAM AT STATION 325 RBL 20 HAD CORROSION. REMOVED ALL CORROSION IAW REF C ALODINE, FINISH WITH 2 COATS OF BMS10-11. (M)SDR AALA984234Floorbeam · corrodedAFW - FLOORBEAM AT RBL 33 HAD CORROSION BLENDED BEYOND SRM LIMITS. ROTO-PEEN BLENDED AREAS PER SRM. ALODINED ALL BARE ALUM SURFACES FINISH BLENDED AREAS WITH 2 COATS BMS 10-11 PRIMER. FILL BLENDS WITH BMS PROSEAL 870. (M)SDR AALA984233Floorbeam · corrodedAFW - FLOORBEAM AT STATION 1565 LBL 77 HAD CORROSION BLENDED BEYOND SRM LIMITS. FABRICATE REPAIR STRAP OUT OF 301 1/2H STAINLESS STEEL .050 INCH THICK. ALODINE ALL BARE ALUMINUM SURFACE FINISH BLEND AND REPAIR PARTS WITH 2 COATS BMS10-11 PRIMER FILL BLENDS WSDR AALA984232Floorbeam · corrodedAFW - FLOORBEAM AT LBL 11 HAD CORROSION BLENDED BEYOND SRM LIMITS. ROTO-PEEN, BLENDED AREAS PER SRM. ALODINE ALL BARE ALUM SURFACES FINISH BLENDED AREAS WITH 2 COATS OF BMS10-11 PRIMER. FILL BLENDS WITH BMS5-95 PROSEAL 870. (M)SDR AALA984236Floorbeam · corrodedAFW - FLOORBEAM AT RBL 54 HAS CORROSION BLENDED BEYOND SRM LIMITS. ROTO PEEN BLENDED AREA PER SRM, ALODINED ALL BARE ALUM SURFACES. FINISH BLENDED WITH 2 COATS OF BMS10-11, PRIMER FILL BLENDS WITH BMS 5-95 PROSEAL 870. (M)SDR AALA984238Floorbeam · corrodedAFW - FLOORBEAM AT STAITON 325 RBL 20 HAD CORROSION BLENDED BEYOND LIMITS. REMOVED ALL CORROSION IAW REF C ALODINE, FINISH WITH TWO COATS FO BMS10-11, FILL WITH BMS 5-95. (M)SDR AALA984237Floorbeam · corrodedAFW - FLOORBEAM AT STATION 266 RBL 26 HAD CORROSION BLENDED BEYOND SRM LIMITS. FABRICATE REPAIR STRAP OUT OF 301.5 INCH STAINLESS STEEL .050 INCH THICK. ALODINE, FINISH BLEND AND REPAIR PARTS WITH 2 COATS OF BMS10-11 PRIMER, FILL BLENDS WITH BMS 5-92. INSTASDR AALA984245Frame · corrodedAFW - FOUND CORROSINO ON 'J' CAP BLENDED BEYOND LIMITS AT STATION 368 LBL 36. TRIM FLANGE AS SHOWN IN ATTACHED FIGURE AND ENSURE ALL CORROSION IS REMOVED. FABRICATED REPAIR ANGLE AND FILLER PER SKETCH. FINISH REPAIR ANGLE AND FILLER PER 767 SRM 53-00-07 FIGSDR AALA984246Stringer · corrodedAFW - FOUND CORROSION BLENDED BEYOND SRM LIMITS ON STRINGER 37L - STATION 774. BLENDOUT CORROSION AND MAKE SURE NO CRACKS EXIST. REFINISH THE BLENDED AREA PER THE REF. ALL FASTENERS COMMON TO THE CORROSION BLENDS ARE .0156 OVERSIZE, USING THE SAME TYPE AS FSDR AALA984243Skin · corrodedAFW - FOUND CORROSION BLENDED BEYOND SRM LIMITS, PARENT MATERIAL .260, AREA BLENDED 20 TO 1 MIN .219. PARENT MATERIAL .260, AREA BLENDED 20 TO 1 MINUTE .219. REMOVE CORROSION AND BLEND IAW REFERENCE B ALODINE AND APPLY TWO COATS OF PRIMER. (M)SDR AALA984242Frame · corrodedAFW - FOUND CORROSION OUT OF SRM LIMITS ON TEE-INNER CHORD, ONE AREA BLENDED. SECOND AREA CORROSION CUT OUT. INSTALLED FILLER OF .125 7075T6 ALUM IN CUTOUT. INSTALLED REPAIR STRAP OF .125 7075T6 ALUM INSTALLED WET W/BMS 5.95 USING BACB30NW6K FASTENERS. BLESDR AALA982128Wire · brokenORD - DURING MAINTENANCE, EMERGENCY EXIT LIGHTS AT SEAT ROWS 20H THROUGH 30H WOULD NOT ILLUMINATE. REPAIRED EMERGENCY EXIT LIGHT CHAFED WIRE AT SEAT ROW 28H. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA984222Support · corrodedAFW - VERY FORWARD VERTICAL LEG OF L-2 DOOR FLOOR SUPPORT TEE (SPLASH GUARD) AT STATION 1480, HAD CORROSION BLEND BEYOND SRM LIMITS. REFER TO ATTACHED FIGURE, BLEND OUT CORROSION, ALODINED AND APPLY TWO COATS OF PRIMER. (M)SDR AALA984221Floorbeam · corrodedAFW - FLOORBEAM AT STATION 347 HAS CORROSION REMOVAL ON UPPER SURFACE. ALODINE BLENDED AREA FABRICATE STRAP APPLY TWO COATS PRIMER FILL BLENDED AREA INSTALL STRAP WET. (M)SDR AALA984220Floorbeam · corrodedAFW - FLOORBEAM AT STATION 287 HAS CORROSION REMOVAL ON UPPER SURFACE. ALODINE BLENDED AREA FABRICATE STRAP APPLY TWO COATS PRIMER. INSTALL STRAP WET WITH SEALANT. (M)SDR AALA984225Skin · corrodedAFW - FOUND CENTER WING UPPER SKIN HAD CORROSION BLENDED BEYOND SRM LIMITS, AT STATION 955 RBL 71. REPAIRED IAW MRB 767-1735. (M)SDR AALA984223Skin · corrodedAFW - BULK CARGO DOOR HAD 5 SMALL AREAS OF CORROSION BLENDED BEYOND SRM LIMITS. REPAIRED IAW MRB 767-1739. (M)SDR AALA984216Floorbeam · corrodedAFW - FLOORBEAM RBL 11 AND STATION 875 HAD A WEAR MARK AND LIGHT CORROSION BLENDED BEYOND LIMITS. BLEND OUT CORROSION, ROTO-PEEN AREA. ALODINE AND APPLY TWO COATS OF PRIMER AND FILL WITH SEALANT. (M)SDR AALA984215Floorbeam · corrodedAFW - FLOORBEAM AT STATION 325 HAS CORROSION REMOVAL ON UPPER AND LOWER SURFACE. ALODINE BLENDED AREA, FABRICATED STRAP. APPLY TWO COATS PRIMER, INSTALL STRAP WET WITH SEALANT. (M)SDR AALA984184Floorbeam · corrodedAFW - FLOORBEAM AT STATINO 325 HAS CORROSION REMOVAL ON UPPER SURFACE. ALODINED AREA, FABRICATED STRAP FROM .050 301.5 HARD STAINLESS STEEL. ATTACHED STRAP USING BACB30NW6 HI-LOCKS. APPLIED TWO COATS PRIMER TO STRAP AND FLOORBEAM. (M)SDR AALA984214Floorbeam · corrodedAFW - FLOORBEAMS AT LT AND RT BL 11 HAVE CORROSION REMOVAL ON UPPER SURFACE STATION 933. ROTO PEEN BLENDED AREA, ALODINE BEFORE PRIMER, APPLIED TWO COATS PRIMER. FILL BLENDS WITH BMS5-95. (M)SDR AALA981931Wire · brokenSFO - DURING OVERNIGHT MAINTENANCE, FORWARD GALLEY BIDIRECTIONAL EMERGENCY FLOOR PATH LIGHTS INOPERATIVE. REPAIRED BROKEN WIRE AT FORWARD GALLEY BIDIRECTIONAL EMERGENCY FLOOR PATH LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA984211Splice · corrodedAFW - FORWARD CARGO COMPT STRINGER SPLICES AND STRINGERS HAVE CORROSION. TRIM BACK TO COMPLETELY REMOVE THE CORROSION ON THE AFFECTED STRINGER INSTALL THE STRINGER SPLICE REPAIR. (M)SDR AALA984207Floorbeam · corrodedAFW - FLOORBEAM AT STATION 347 RBL 34 HAD LIGHT CORROSION BLENDED FROM THE UPPER AND LOWER SURFACE OF THE TOP CAP. REFER TO FIG 1, COMPLETELY REMOVED CORROSION, ALODINE ALL BARE ALUMINUM SURFACES. FINISHED BLENDED AREA WITH TWO COATS OF PRIMER. FILL BLENDS SDR AALA984205Floorbeam · corrodedAFW - FLOORBEAM AT STATION 287 HAS CORROSION REMOVAL ON UPPER SURFACE. REFER TO FIGURES 1, 2 AND 3, ALODINE ALL BARE ALUMINUM SURFACES, REFINISH THE BLENDED AREA WITH 2 COATS OF PRIMER, FILL BLENDS WITH PROSEAL 870. (M)SDR AALA984206Floorbeam · corrodedAFW - FOUND FLOORBEAM AT STATION 1480 HAS CORROSION REMOVAL ON UPPER SURFACE. FABRICATE REPAIR STRAP OUT OF 301.5 H STAINLESS STEEL, .050 THICK. ALODINE AND PRIME ALL BARE SURFACES. FILL BLENDS WITH BMS 5-92. INSTALL REPAIR STRAP WET WITH BMS-95 SEALANT. SDR AALA984199Frame · corrodedAFW - AFT CARGO FRAME J CAP AT STATION 1087 RBL 20 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIR IAW MRB 767-1719. (M)SDR AALA981822Light · inoperativeSFO - EMERGENCY SEAT LIGHT AT SEAT 30 H/J INOPERATIVE. REPLACED SEAT 30H/J. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981712Control Panel · failedDTW - FLT 24 - EN ROUTE ORD-BHX, AFT CARTO FIRE LIGHT ILLUMINATED. NO FIRE, AIR INTERRUPTED AND LANDED DTW WITHOUT INCIDENT. REPLACED APU/CARGO FIRE CONTROL PANEL. ACCOMPLISHED TEST OF SYSTEM. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981654Light · inoperativeORD - FLT 95 - ON AIRCRAFT SHUTDOWN AT ORD GATE, COCKPIT DOOR EMERGENCY EXIT LIGHT WOULD NOT EXTINGUISH. REPLACED COCKPIT DOOR EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981658Transformer · failedORD - FLT 185 - DURING CRUISE, RED EQUIPMENT ACCESS ON OVERHEAD PANEL ILLUMINATED WITH ASSOCIATED EICAS MESSAGE. SOUND OF ELECTRICAL ARCING WAS NOTED BY CREW. LIGHT ALSO ILLUMINATED NOSE UNSAFE GEAR LIGHT. LANDED ORD WITHOUT INCIDENT. REPLACED LEFT UNIT. SDR AALA981595Light · inoperativeSFO - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT FIXTURE RIGHT SIDE OF BUSINESS CLASS GALLEY MISSING. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY FOR RIGHT SIDE OF BUSINESS CLASS GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981528Light · inoperativeSFO - DURING OVERNIGHT MAINTENANCE, EMERGENCY ESCAPE LIGHT AT SEAT ROW 27H WOULD NOT ILLUMINATED. REPLACED EMERGENCY ESCAPE LIGHT ASSEMBLY AT SEAT ROW 27H. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981526Light · inoperativeSFO - DURING OVERNIGHT MAINTENANCE, EMERGENCY CEILING LIGHT AT SEAT ROW 7 RIGHT SIDE WOULD NOT ILLUMINATE. REPLACED EMERGENCY CEILING LIGHT ASSEMBLY AT SEAT ROW 7 RIGHT SIDE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA984177Strap · corrodedAFW - AFT CARGO DOOR FRAME FAIL/SAFE STRAP HAD CORROSION BLEND ON TOP SURFACE. BLEND ALL CORROSION, ROTO PEEN AREA AND REFINISH IAW TO SRM REQUIREMENTS. (M)SDR AALA984176Stringer · corrodedAFW - AFT END OF 38L AT STATION 434 WAS BADLY CORRODED. REMOVED CORRODED PIECE OF STRINGER. REPLACED WITH SIMILAR LONGER SPLICE WITHOUT A JOGGLE. (M)SDR AALA984175Splice · corrodedAFW - STRINGER 33R WAS BADLY CORRODED, AFT OF STATION 434. REMOVE CORRODED PIECE OF STRINGER. REPLACE WITH SIMILAR LONGER SPLICE WITHOUT A JOGGLE. (M)
Back to Boeing 767-223