Boeing 767-322
Service difficulty reports · 11,764
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012011200265Light · inoperativeONE SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE AND LOOSE AT SEAT 1H. REPLACED LIGHT, OPS CHECKED NORMAL.SDR UALA2012011200271Eec · failedIDLE DISAGREE EICAS, RTFL. REPLACE RT ENGINE EEC FOR TROUBLESHOOTING. REPLACED EEC PER AMM, ACCOMPLISHED ENG RUN PER TASK 6 MM 71-00-00-501, NO HELP. CARRIED OUT PIMU BITE TEST FOUND CHANNEL A & B MESSAGES, EEC UNIT FAIL-EEC CTRL- EEC CAT 1 AND EEC CAT 2 MESSSDR UALA2012011100241Accessory Unit · malfunctionedPA IS INTERMITTENT FROM COCKPIT & MICROPHONE AT L1 DOOR . REPLACED AUDIO ACCESSORY UNIT PER AMM. CHECKED SETTING OF PA AMPLIFIER. RESET ALL CABIN HANDSETS. SYSTEM OPS NORMAL.SDR UALA2012011200270Restrictor · deterioratedBLEED AIR LEAK. EXCESSIVE AIR NOISE ABOVE CROSS AISLE JUMP SEAT AFT OF FWD GALLEY. INSPECTED DUCTING ABOVE CEILING, ALL CONNECTIONS LOOK GOOD AND FLOW IS GOOD. FURTHER INSP FOUND AIRFLOW RESTRICTORS DETERIORATED AT THE PLENUM FOR THE OVERHEAD AIR OUTLET ABOSDR UALA2012011100238Battery Pack · inoperativeRIGHT SIDE EMERGENCY EXTERIOR LIGHTS ARE INOPERATIVE. REPLACED BAD LIGHT ASSY, BATTERY PACK AND CHARGER.SDR UALA2012011100225Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE AT SEATS 37-41HJ, EXIT FLOOR LEFT 3R, AFT GALLEY CROSSAISLE, RT AFT CARGO DOOR (FORWARD SIDE EXTERIOR). REPLACED BATTERY PACK, EMERGENCY LIGHTS OK.SDR UALA2012011100227Oxygen Mask · misinstalledCENTER PAX OXYGEN MASKS PACKED IMPROPERLY. REPACKED ALL CENTER PAX OXYGEN MASKS.SDR UALA2012011000223Oxygen Mask · misinstalledLEFT PAX OXYGEN MASKED PACKED IMPROPERLY. REPACKED LEFT PAX OXYGEN MASKS.SDR UALA2012011000224Light · inoperativeEEL LIGHT STRIP BETWEEN DOORS 1 RT AND 1 LEFT JUST AFT OF G1 GALLEY INOP. REPLACED EEL STRIP IAW B767 GNMM 2-0-15-005. OPS CHECKS GOOD.SDR UALA2012011000218Oxygen Mask · misinstalledRIGHT PAX OXYGEN MASK PACKED IMPROPERLY. REPACKED. REPACKED OXYGEN MASKS.SDR UALA2012010900217Unknown · leakingOIL POOLED IN INLET OF LEFT ENGINE AND BEHIND FAN SECTION AND DRIPPING ONTO GROUND. INSPECTED ENGINE. SLIGHT POOLING IN INLET. OIL WETTING OR PUDDLING IN SPINNER AREA OK FOR SERVICE PER MM. OIL CONSUMPTION NORMAL.SDR UALA2012010900200Pressure Switch · faultyRUDDER RATIO EICAS ON WHEN SELECTION OF FLAPS 5 ON APPROACH. LT SYS HYD PRESSURE LIGHT DOES NOT COME ON WITH HYD 'OFF'. SUSPECT SWITCH S27. REF FIM AND FAULT BITE INDICATED LT HYD PRESS SWITCH. REPLACED SWITCH AND NO FAULTS NOTED. REPLACED RUDDER RATIO CHSDR UALA2012010900205Actuator · stuckLEFT REVERSER LEVER STUCK IN IDLE REV. REV LEVER INTERLOCK ACTUATOR IN RETRACTED POSITION. RMV'D POWER FROM ACFT, REPOWER ACFT TRIED REVERSER - REVERSE LEVER INTERLOCK NOW INOP (EXTENDED). REPLACED INTERLOCK RELAY - NO HELP. REVERSE LEVER INTERLOCK INOP EXSDR UALA2012010900201Fire Loop · openSTATUS MESSAGE NR 2 ENGINE FIRE LOOP 2. SYSTEM RESISTANCE EXCEEDS LIMITS WHEN CHECKING FROM CARD FILE. FOUND LOOP TS683 OPEN. REPLACED LWR FWD FIRE LOOP TS683 REF TO WD26-11-21, GROUND TESTED GOOD.SDR UALA2012010900215Actuator · leakingLOWER RUDDER ACTUATOR LEAKING AT PISTON. INSTALLED NEW LOWER RUDDER ACTUATOR. REMOVED MR27250-65 OFF AND -91 ON. NEED TO COMPLETE FROM STEP I-5 ON PAGE 219. COMPLETED INSTALLATION AND OPS CHECK OF RUDDER PCA SYSTEM PER MM.SDR UALA2012010900214Actuator · leakingFOUND RT YAW DAMPER ACTUATOR M509 LEAKING DURING OPERATION. INSTALLED NEW ACTUATOR PER MM.SDR UALA2012010600141Outflow Valve · failedOUTLFOW VALVE INOPERATIVE IN MANUAL MODE. CHECKED FOR VOLTAGE AT MOTOR. VOLTAGE PRESENT AT CLOSE AND OPEN CIRCUITS. REPLACED OUTFLOW VALVE ACTUATOR, PER AMM. AUTO AND MANUAL OPERATED NORMAL.SDR UALA2012010600149Gcu · faultedLT GENERATOR FAULT, FLIGHT DIVERTED. CARRIED OUT BPCU BITE CHECK. FOUND LEFT GENERATION SYSTEM FAULTS. REPLACED LT GCU AND IDG REF MM. FURTHER T- S REQUIRED DUE FAULTS STILL EXISTING. ITEM TRANSFERRED TO SMC6 AS FAULT NOW WITH DAMAGED C901 CONTACTOR IN P3SDR UALA2012010500112Blade · damagedRT ENGINE HAS A SIGNIFICANT NICK IN BLADE 2, BLADE DAMAGE IS AT DIM LEADING EDGE FROM BASE TO DAMAGE IS 20.700. APPROX 750. DEPTH AND LENGTH IS 1.0 INCH. PER MM DOCUMENT BLADE IS NOT REPAIRABLE. REPLACED NR 2 1ST STAGE FAN BLADE AND OPPOSITE FAN BLADE NR 21.SDR UALA2012010600136Skin · damagedAIRCRAFT DAMAGED BY LOADER, DAMAGE AFT OF AFT CARGO DOOR ABOUT 10 INCHES IN FRONT OF EXTERIOR AREA LIGHT. DAMAGE IS LOCATED BETWEEN STRINGER 27R AND 28R. BS 1373. MEASURES 4"X4".350 DEEP, GOUGES ARE .030 AND .060 DEEP. FRAME SHEAR TIE FOUND CRACKED AT BS 1SDR UALA2012010600142Helicoil · failedLEFT THRUST REVERSER DEACTIVATION PIN HELICOIL PULLED OUT. REPLACED RIGHT ENGINE INBOARD DEACTVATION PIN HELICOIL.SDR UALA2012010500114Light · damagedTHE 6HJ FWD AND AFT EMERGENCY LIGHT DAMAGED. REPLACED LIGHT, OPS CHECKED GOOD.SDR UALA2012010500113Light · brokenSEAT 10H EMERGENCY LIGHT IS BROKEN IN HALF. REPLACED, OP CHECKED GOOD.SDR UALA2012010400088Controller · failed'RT PACK INOPERATIVE' LIGHT ON. EICAS MESSAGE 'RT PACK TEMP' DISPLAYED. OPERATED NORM AFTER 'STANBY' SELECTED. RIGHT PACK CONTROLLER 'RAM INLET ACTUATOR', 'LOW LIMIT VALVE' & 'COMPRESSOR SENSOR'. REPLACED RIGHT PACK CONTROLLER. BITE TESTED OKAY.SDR UALA2012010500115Light · intermittentEMERGENCY EXIT PATH LIGHT ON INTERMITTENTLY FROM ROW 35 BACK TO DOOR 2L MOSTLY DURING CLIMB. GROUND CHECKED OKAY.SDR UALA2012010400102Idg · warning lightLEFT ENGINE GENERATOR OFF LIGHT AND FIELD OFF LIGHT ILLUMINATED. REPLACED NR 1 IDG IAW AMM. IDLE RUN CKS OK.SDR UALA2012010400101Gcu · unknownDUE TO SEVERAL REPORTS OF LEFT GENERATOR OFF LIGHT ON DURING ENGINE START. PERFORMED BPCU BITE CHECK, SERVICED LT IDG OIL. REPLACED LEFT GCU PER MM.SDR UALA2012010400100Shutoff Valve · failedRAN NR 2 ENGINE AT IDLE. NR 2 BLEED SLOW TO RISE TO 34 PSI AND WHEN THERE IS A DEMAND (IE. PACK OR ADP) BLEED DROPS TO 5 PSI. ONCE DESELECTING DEMAND IT GOES BACK TO 34 PSI. REMOVED PRSOV MR36159-146, REPLACED NR 2 PRSOV PER MM, OPS CHECKED GOOD.SDR UALA2012010400089Computer · failedLEFT EICAS STATUS MESSAGE WONT CLEAR. REPLACED LT EICAS COMPUTER, CONDITION NORMAL. EICAS MESSAGE EXTINGUISHED.SDR UALA2012010300040Connector · dirtyLAVATORY BY BUSINESS GALLEY, EMERGENCY LIGHT FLICKERS. CLEANED SECTION CONNECTORS AS PER AMM, ALL OPS OKAY. OPS CHECKED AND ALL OKAY.SDR UALA2012010400076Generator · failedAPU GENERATOR WOULD NOT COME ONLINE DURING TAXI. APU FIELD TRIPS, BPCU APU BIT:OPEN POR-FDR GEN AND UNDERVOLT TRIP. TRIED APU GCU, NO HELP, RE-INSTALLED ORIGINAL. REPLACED APU GEN SWITCH, NO HELP. REMOVED AND REPLACED APU GENERATOR PER MM. LEAK AND OPS CHSDR UALA2012010400095Shear Tie · damagedFOUND SHEAR TIE DAMAGED AT STA 1373 BTWN STRINGERS S27-R AND S28-R. SHEAR TIE HAS 3 SHEARED RIVETS ALONG WITH 5 AND HALF INCH TEAR, WHICH HAS BUCKLED THE FRAME. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW SHEAR TIE PER SRM.SDR UALA2012010400094Skin · damagedDURING OPEN UP OF DAMAGED AREA AFT OF THE AFT CARGO DOOR, FOUND BENT FRAME AT STA 1373 BETWEEN STR 27R AND 28R. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR FILLERS (2 EA), STIFFENERS (2 EA), CHANNEL, AND SHEAR TIE PER ECRA 5360-01171 AND EA PDSDR UALA2012010400093Intercostal · puncturedFOUND PUNCTURE IN AFT CARGO PIT INTERCOSTAL AT REAR OF CARGO DOOR OPENING STRINGER 28R LEVEL. APPEARS TO BE UNRELATED TO INITIAL DAMAGE (FOUND WHILST EVALUATING) PUNCTURE IS APPROX 4.5" X 2.5". FABRICATED AND INSTALLED NEW INTERCOSTAL STA 1351 - 1373, STR 28SDR UALA2012010400090Indicator · faultedCAPTAIN'S VSI OFF FLAG IN VIEW AND POINTER INDICATES DESCENT. REPLACED NR 1 VSI, CHECKED GOOD.SDR UALA2012010400087Actuator · failedRIGHT A/C PACK INOPERATIVE LIGHT ON. EICAS MESSAGE 'RT PACK TEMP' DISPLAYED. OPERATED NORM AFTER 'STBY' SELECTED. REF MM 21-51-00 FIG 103 BLOCK 1. BITE SHOWS INOP RT A/C PACK INLET DOOR ACTUATOR. INLET DOOR VERIFIED CLOSED AND OUTLET DOOR FULLY OPEN. PULSDR UALA2012010400086Light · dislodgedSEAT EXIT LIGHTS FALLING OFF AT 3AB AND 6AB. REPLACED EMERGENCY LIGHTS.SDR UALA2012010300042Igniter · failedNO EGT RISE ON RT ENG WITH NR 2 IGNITION START OK ON BOTH IGNITORS. REPLACED NR 2 IGNITER PLUG IAW MM, ENGINE STARTED OK PER JRH 2-6-1.SDR UALA2012010300035Fan · failedTHREE EVENTS OF ONE MINUTE DURATION OF ELECRICAL ODOR THRU COCKPIT AND CABIN NO SMOKE. UNABLE TO LOCATE OR IDENTIFY SOURCE, ON LANDING OF ELECRICAL ODOR. RECIRCULATION FAN INOPERATIVE LIGHT ON. FOUND LEFT RECIRCULATION FAN CIRCUIT BREAKER TRIPPED ON P36 PANESDR UALA2012010300033Fan · failedON ARRIVAL, LEFT RECIRCULATON FAN FAILED WITH ASSOCIATED EICAS MESSAGE AND OVERHEAD LIGHT WITH BURNED ODOR IN COCKPIT. LEFT RECIRCULATION FAN CIRCUIT BREAKER ALSO FOUND TRIPPED.SDR UALA2012010300069Shutoff Valve · failedAPU PNEUMATICS NOT OPENING FOR ENGINE START. PACKS OFF. APU BLEED VALVE BAR SHOWS OPEN, YET NO DUCT PRESSURE FOR ENGINE START. REPLACED APU AIR SUPPLY SHUTOFF VALVE PER MM. OPS CHECKED OK.SDR UALA2012010300060Wire · brokenCENTER FCC FAILS INTERFACE TEST 04. FOUND WIRE W011-770-22 BROKEN AT CONNECTOR D479. REPINNED WIRE REF BOEING STANDARD PRACTICES MANUAL 20-10-13. CTR FCC TEST NORMAL. ACP CAT III TEST PER MM, TEST PASSED. AIRCRAFT RETURNED TO CAT III STATUSSDR UALA2012010300011Frame · corrodedCORROSION ON FRAME STA 916, NEAR STR 20L. CORROSION OUT OF LIMITS, FABRICATED AND INSTALLED REPAIR PER SRM ON PEMCO NR 3872N 00597.SDR UALA2012010300010Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER CAP AT BS 1196.66 ACROSS ENTIRE BEAM IN REAR CARGO.SDR UALA2012010300014Floorbeam · corrodedPASSENGER CABIN FLOOR STRUCTURE AT BS 287 FROM RBL 40 TO RBL 73 HAS CORRODED FLOORBEAM. MAJOR REPAIR ACCOMPLISHED. RPLC'D T-CHORD, T-CAP, ANGLES AND BRACKET AT STA 287, RBL 31 - RBL 82 PER SRM.SDR UALA2012010300065Latch · unsecureON PREFLIGHT F/O FOUND AFT LATCH OF LEFT ENGINE CORE COWL HANGING DOWN FOUND BROKEN KEEPER ASSY FOR LATCH. REPLACED AND ADJUSTED PER AMM.SDR UALA2012010300007Wire · burnedTHERE WAS SMOKE, SPARKS AND SMALL FLAMES COMING OUT OF AFT GALLEY CART CONTROLLERS PANELS. ALL AFT GALLEY CART CONTROLLER POWER CIRCUIT BREAKERS ON AFT GALLEY POWER DISTRIBUTION WERE PULLED, POWER TO CART CONTROLLERS WERE REMOVED. CREW NOTICED DAMAGE ON PIGTSDR UALA2012010300066Battery · faultedAPU RUNNING WITH FAULT LIGHT. REPLACED AIRCRAFT BATTERY AND OPS OK ALL SYSTEMS NORMAL.SDR UALA2012010300059Selector Knob · brokenHEADING SELECT KNOB BROKEN BUT USEABLE. REPLACED MCP PER MM.SDR UALA2011122907159Battery Pack · malfunctionedEMERGENCY EXIT LIGHTS ON LAST 6 ROWS LEFT SIDE WITH SWITCH ARMED IN-FLIGHT. REPLACED BATTERY PACK.
Back to Boeing 767-322