Boeing 767-322

Service difficulty reports · 11,764

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '767322'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UALA2011080504085Nozzle · obstructedFIRE EXT NOZZLE PARTIALLY COVERED WITH PIT TAPE. AFT NOZZLE IN AFT PIT. TAPE PARTIALLY BLOCKING NOZZLE TRIMMED PER MM, OTHER NOZZLES CHECKED IN FWD, AFT & BULK PITS. ALL OKAY.Aug 4, 2011 · N654UA · Boeing 767322 · Extinguishing SystemSDR UALA2011080404075Sensor · faultyRT WINDOW HEAT INOP LIGHT. LOCKED OUT CB. FOUND RIGHT WINDOW 3 SENSOR BAD, SWAPPED SENSOR WIRES PER MM. BITE OK PER MM. GENERATED CF ITEM FOR MONITORING.Aug 4, 2011 · N672UA · Boeing 767322 · Windshield/Door Rain/Ice RemovalSDR UALA2011080404064Unknown · malfunctionedEQUIP OVHT LIGHT ILLUMINATED AFTER T/O. RAN CHECK LIST NOW NN STBY POSITION LIGHT OFF. "FWD EQT FLOW" EICAS MSG DISPLAYED WITH ASSOCIATED OVHT LIGHT ON. FAN AND VALVE OPERATED NORMAL ON GROUND. KOA NO TIME TO T/S FURTHER. -INF- :SUSPECT EXHAUST FAN NOT RUAug 4, 2011 · N668UA · Boeing 767322 · Cabin Cooling SystemSDR UALA2011080404063Cdu · malfunctionedF/O FMC CDU BLANK RTFL, HAPPENED ON PREFLIGHT AND RESET CB E29. CDU WORKED OK UNTIL NOW. REPLACED F/O'S FMC CDU IAW MM 34-61-02. OPS CHECK NORMAL.Aug 4, 2011 · N659UA · Boeing 767322 · Central DisplaySDR UALA2011080404074Windshield Wiper · defectiveF/O WINDSHIELD WIPER WON'T STOP. ALSO THE CAPT'S OUTER PORTION OF WINDSHIELD WIPER DOES NOT CLEAN RAIN FROM WINDOW. REPLACED F/O WIPER ARM ASSY IAW MM. REPLACED CAPT'S WIPER BLADE. OPS CHECK NORMAL.Aug 3, 2011 · N663UA · Boeing 767322 · Windshield/Door Rain/Ice RemovalSDR UALA2011080404073Battery · overheatedMAIN BAT CHGR EICAS STATUS MSG. MAIN SHIPS BATTERY WAS OVERHEATING AND SHUTTING CHARGER. REPLACED MAIN SHIP BATTERY, OPS TEST OKAY.Aug 3, 2011 · N668UA · Boeing 767322 · Battery/Charger SystemSDR UALA2011080304059Idg · failedELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE). REPLACED IDG PER MM AND ALSO REPLACED IDG DRIVE SEAL.Aug 3, 2011 · N663UA · Boeing 767322 · AC Generator-AlternatorSDR UALA2011080504076Light · inoperativeEEL LIGHT ON SEAT 14H INOPERATIVE. REPLACED 14HJ SEAT MOUNTED EEL LIGHT.Aug 3, 2011 · N676UA · Boeing 767322 · Emergency LightingSDR UALA2011080304031Oven · malfunctionedGALLEY OVEN WON'T HEAT AT R13. CLEANED ALUMINUM WRAP IN BAFFLE PLATE. CHECKED TEMP 350 DEG PER MM, OPS CHECKED GOOD.Aug 3, 2011 · N676UA · Boeing 767322 · Buffet/GalleysSDR UALA2011080304051Shutoff Valve · faultyLEFT ENGINE HPSOV EICAS WITH LT BLEED ANNUNCIATOR. HPSOV LOCKED OUT. REPLACED LT ENG HPSOV AND LT BLEED AIR CONTROL PC PER MM. LT ENGINE RUNUP CHECKED OKAY.Aug 3, 2011 · N672UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2011080304044Unknown · malfunctionedTCAS HAS FAILED. PERFORMED TCAS OPERATIONAL TEST PER MM. TCAS OP'S TEST OKAY.Aug 3, 2011 · N671UA · Boeing 767322 · Air Collision Avoidance SystemSDR UALA2011080304041Switch · faultySTANDBY POWER SWT ON OVERHEAD PANEL DOES NOT HAVE DETENT FROM AUTO TO OFF. INSTALLED SWITCH, TESTED STNDBY PANEL ACCORDING TO AMM. SWITCH PCN (586-2220) PN 3600-5478. NO TAG ATTACHED ACCORDING SAMC.Aug 3, 2011 · N654UA · Boeing 767322 · DC Power Distribution SystemSDR UALA2011080304052Heat Shield · failedNR 2 ENG OIL TANK HEAT SHIELD HAS DETERIORATED. REPLACED HEAT SHIELD.Aug 2, 2011 · N657UA · Boeing 767322 · Turbine Engine Oil SystemSDR UALA2011080304053Relay · failedCAPT SIDE PRIMARY FLIGHT INSTRUMENTS ALL BLANK. REPLACED RELAY K862. CAPT'S EFIS OP CHECKED NORMAL.Aug 2, 2011 · N647UA · Boeing 767322 · Central DisplaySDR UALA2011080304013Fairing · missingDURING RAMP CHECK FOUND PANEL MISSING ON AFT TOP OF RIGHT LANDING GEAR BODY DOOR AREA. ACCOMPLISH REPAIRS PER EVA 81169. RT WING MLG SIDE STRUT SWIVEL FAIRING ASSEMBLY TEMPORARY FAIRING INSTALLED AS PER EVA-8 1169. VERIFICATION REQUIRED BEFORE EACH FLIGHT Aug 2, 2011 · N652UA · Boeing 767322 · Aerodynamic FairingsSDR UALA2011080304050Autothrottle Sys · malfunctionedAUTOTHROTTLE FAIL AT STATUS ON ADI IS BLANK. TMC APPEARS OK. LEG FAULT A-T DISC TMC 01310800 AND TEST FAILURE OF MCDP-TMC. REPLACED TMC. AUTOLAND TEST 02, 30, 40 PASSED.Aug 2, 2011 · N656UA · Boeing 767322 · Auto Throttle SystemSDR UALA2011080204007Seal · leakingHIGH PITCH SQUEAL F/O WINDOW AT FL340. DIFF 8.6 VERY LOUD. FOUND UPPER PORTION OF SEAL WORN ON F/O SLIDING WINDOW. INTERM REPAIR MADE WITH TAPE. PRESSURIZED AC TO 4 PSI NO LEAKS NOTED.Aug 1, 2011 · N676UA · Boeing 767322 · Flight Compartment WindowsSDR UALA2011080204006Pump · faultyON DEP CTR HYD DEMAND EICAS ON FOR GEAR RETRACTON THEN AGAIN FLAPS 5-1. NOTED HISTORY FOR THIS PROBLEM. NEEDS MORE TROUBLESHOOTING. INF- SUSPECT ADP OUTPUT IS MARGINAL DURING HIGH DEMANDS AND MOST LIKELY WILL NEED REPLACED. -CQT- :ADP PCN IS 643-9064, ONAug 1, 2011 · N668UA · Boeing 767322 · Hydraulic Pump (Electric/Engine), MainSDR UALA2011080204005Idg · failedCREW REPORT: JUST PRIOR TO TAKING RUNWAY L AC BUS FAILED. ACP TROUBLESHOOTING PER TABLE 102 REF MM P163 FOR DP TRIP AND MAIN BUS-OVERLAP. ALL WIRE CHECKS SAT. CREW ALSO REPORTED THE LEFT GENERATOR CONTROL TRIPPED AND THE LEFT TIE BUS ALSO FAILED. BOTH THEAug 1, 2011 · N663UA · Boeing 767322 · AC Generator-AlternatorSDR UALA2011080204004Idg · defectiveRT IDG RED DIFFERENTIAL PRESSURE INDICATOR POP. REPLACED IDG WITH NEW ONE, LEAK CHECKED AND OPS CHECKED NORMAL.Aug 1, 2011 · N660UA · Boeing 767322 · AC Generator-AlternatorSDR UALA2011080103925Idg · failedPER INBOUND CREW, LEFT BUSS TRIPPED ON THROTTLE ADVANCE DURING T/O. RESET AS REQUIRED. ITEM HAS HISTORY. DUE HISTORY OF THIS FAULT, THIS ITEM IS GENERALLY CAUSED BY A DEFECTIVE IDG. SUSPECT IDG INSTALLED BY PREVIOUS STATION FOR ANOTHER TYPE FAULT, NEEDS RPAug 1, 2011 · N663UA · Boeing 767322 · AC Generation SystemSDR UALA2011080103965Warning System · activatedL ENG HPSOV EICAS & BLEED LT AFTER ENG START.Aug 1, 2011 · N641UA · Boeing 767322 · Pneumatic Indicating SystemSDR UALA2011080103961Monitor · defectiveHYDRAULIC QUANTITY MONITOR UNIT NEEDS REPLACEMENT. REPLACED HYD QTY MONITOR.Aug 1, 2011 · N657UA · Boeing 767322 · Hydraulic Quantity IndicatorSDR UALA2011080103978Battery · failedAPU WILL NOT CRANK. REPLACED BATTERY PER MM, OPS CHECKED NORMAL.Jul 31, 2011 · N659UA · Boeing 767322 · APU Start/Ignition SystemSDR UALA2011080103980Shutoff Valve · malfunctionedRIGHT ENGINE (BLEED) OFF LIGHT ON & RIGHT ENG BLEED OFF EICAS MESSAGE, WITH ENGINE RUNNING, ENGINE BLEED SWITCH ON, LT & RT ISOLATION VALVES CLOSED, A/C PACK SELECTED ON, & DUCT PSI IS ZERO. OFF LIGHT STAYS ON WHEN N1 IS ABOVE 41 PERCENT. RIGHT ENGINE BLEEDJul 31, 2011 · N671UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2011080103979Battery Pack · malfunctionedROW 25-35 H&J EMERGENCY LIGHTS ON & SOMETIMES FLICKERING. REPLACED BATTERY PACK FOR LIGHT GROUP AND OP CHECKED.Jul 31, 2011 · N665UA · Boeing 767322 · Emergency LightingSDR UALA2011080103990Satcom · inoperativeON STATUS PAGE CANNOT ERASE SATCOM HIGH GAIN. RESET SAT COM C-B'S AND SAT COM BITE TESTS OK MADE SAT COM RADIO CONTACT TO SAMC. ALL LOUD AND CLEAR. MADE SEVERAL CALLS TO SAMC, SYSTEM OPERATED NORMALLY. BUT AFTER ABOUT ONE HOUR ON THE GATE GOT "SATCOM HIGH Jul 31, 2011 · N668UA · Boeing 767322 · Communications SystemSDR UALA2011080103986Shutoff Valve · faultyLEFT ENG HPSOV EICAS MSG ON DESCENT. QRH PROCEDURE-CHECKLIST ACCOMPLISHED. LT ENGINE BLEED SWITCH OFF. REPLACED HPSOV ON NR 1 ENGINE RAN ENGINE, OP CHECKED GOOD.Jul 31, 2011 · N676UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2011080103982Actuator · leakingRAMP REPORTED FLUID LEAK NR 2 ENGINE. FOUND NR 2 ENGINE INBOARD UPPER REVERSER ACTUATOR LEAKING 5 DROPS PER MINUTE.Jul 31, 2011 · N653UA · Boeing 767322 · Engine Thrust ReverserSDR UALA2011080103977B-Nut · leakingFLAP SLAT HYDRAULIC SHUTOFF VALVE IN RT MAIN GEAR WHEEL WELL LEAKING 20 DROPS PER MINUTE FROM PRESSURE PORT B-NUT. ACCOMPLISHED RINGLOCK REPAIR TO PRESSURE PORT END OF TUBE PER GNMM. LEAK CHECK OKAY.Jul 31, 2011 · N651UA · Boeing 767322 · Hydraulic System, MainSDR UALA2011080103937Fan · malfunctionedEQUIP OVERHEAT LIGHT ILLUMINATED AFTER TAKEOFF. RAN CHECK LIST NOW NN STBY POSITION LIGHT OFF. "FWD EQT FLOW" EICAS MSG DISPLAYED WITH ASSOCIATED OVHT LT ON. FAN AND VALVE OPERATED NORMAL ON GROUND. KOA, NO TIME TO T/S FURTHER. SUSPECT EXHAUST FAN NOT RUNNJul 31, 2011 · N668UA · Boeing 767322 · Air Distribution FanSDR UALA2011080103981B-Nut · leakingFOUND HYDRAULIC LEAK AT LEFT MAIN GEAR ABOVE WHEEL 1 FWD. TIGHTENED B-NUT AT LT ANTI-SKID MODULE. LEAK CHECKED GOOD.Jul 30, 2011 · N675UA · Boeing 767322 · Hydraulic System, MainSDR UALA2011080103924Idg · disconnectedLEFT GENERATOR DRIVE EICAS & DRIVE LIGHT ON DRIVE DISCONNECTED. REPLACED NR 1 ENGINE IDG, OPS CHECKED NORMAL.Jul 30, 2011 · N663UA · Boeing 767322 · AC Generator-AlternatorSDR UALA2011080103926Light · faultyPAX SEAT 1H CVR PLATE ON SIDE OF SET CAME OFF, HAVE IN COCKPIT. RE-SECURED AFT LIGHT ASSY, LIGHT INOP. REPLACED LT ASSY.Jul 30, 2011 · N668UA · Boeing 767322 · Entertainment SystemSDR UALA2011072903916Pump · malfunctionedRIGHT CENTER TANK FUEL PUMP INOPERATIVE AND DEACTIVATED. CIRCUIT BREAKER POPPED ON P-6 PANEL. RAN NR 2 ENGINE FOR 5 MIN, OPS CHECKED RIGHT CENTER TANK FUEL PUMP. NO CIRCUIT BREAKER POP, CENTER TANK FUEL PUMP CHECKED NORMAL PER JRH.Jul 29, 2011 · N647UA · Boeing 767322 · Fuel Boost PumpSDR UALA2011080103923Ignition Sys · failedAPU WILL NOT START. REPLACED IGNITION UNIT.Jul 29, 2011 · N663UA · Boeing 767322 · APU Start/Ignition SystemSDR UALA2011080103922Battery Pack · faultyEXIT SIGN DOOR 1R AS WELL AS FLOOR LIGHTING STRIP BY SAME DOOR ARE FLASHING ON AND OFF. REPLACED POWER SUPPLY BATTERY PACK M1552, OPS CHECKED OKAY.Jul 29, 2011 · N663UA · Boeing 767322 · Emergency LightingSDR UALA2011072803881Duct · crackedFOUND RT PACK INBOARD LWR DUCT BETWEEN REHEATER AND HEAT EXCHANGER CRACKED. RIGHT PACK OUTPUT TEMP 58 DEG WILL NOT GO COLDER TEMP VALVE SHOWS 0.00 POSITION DCT PRSS 31. REPLACED DAMAGED DUCT ASSY.Jul 28, 2011 · N642UA · Boeing 767322 · Cabin Cooling SystemSDR UALA2011072903903Battery · faultedA CABIN APPEARANCE TEAM FOUND DURING AN INTERIOR SWEEP 2 EMERGENCY EXIT LIGHTS INOP AT DOORS 2L AND R. REPLACED BATTERY AND CHARGER ASSY PER MM, LAMPS OP NORMAL.Jul 28, 2011 · N644UA · Boeing 767322 · Emergency LightingSDR UALA2011072903902Shutoff Valve · faultedCENTER HYD DEM PUMP EICAS AND OVERHEAD PANEL PRESS LIGHT DISPLAYED DURING GEAR RETRACTION. TROUBLESHOT PER FIM. FOUND RT PRV FAULT ON ASBM. REPLACED PRV PER MM. RAN CENTER ACCOMPLISHED C1, C2 AND ADP SEPARATELY. CYCLED FLIGHT CONTROLS, GEAR DOORS. NO LOW PJul 28, 2011 · N668UA · Boeing 767322 · Hydraulic System, MainSDR UALA2011072803896Electrical Box · malfunctionedCONSTANT CHIME IN MID CABIN WITHOUT PAX ACTIVATION. REPLACED UNDER SEAT BOX AT SEAT 37D, OPS NOW NORMAL.Jul 27, 2011 · N676UA · Boeing 767322 · Communications SystemSDR UALA2011072703876Transmitter · weakNR 1 VHF COMM RECEPTION POOR AT ALL CREW STATIONS. NR 1 VHF RECEPTION WEAK AND SCRATCHY AT ALL STATIONS. REPLACED NR 1 VHF TRANSMITTER.Jul 27, 2011 · N669UA · Boeing 767322 · VHF Communications SystemSDR UALA2011072703838Transmitter · failedLEFT HYD QTY INDICATION. REPLACED LT HYD QTY TRANSMITTER AMM 29-33-02. R AND E WORKING SIGNAL WIRE OF PTU. AFTER TRANSMITTER WAS REPLACED FOUND DIODE BLOCK R397 WITH BRUNDY TERMINAL JAMMED IN POSITION "C". WIRE TO POSITION "C" WAS BROKEN OFF AND TIED BACK. Jul 27, 2011 · N657UA · Boeing 767322 · Hydraulic Quantity SensorSDR UALA2011072803895Bulb · missingR EMERG ESCAPE SLIDE SQUIB TEST LIGHT IS MISSING. INSTALLED SQUIB LIGHT COVER AND LIGHT BULB.Jul 27, 2011 · N673UA · Boeing 767322 · Escape SlideSDR UALA2011072703878Audio Panel · failedFIRST OFFICER UNABLE TO TRANSMIT FROM O2 MASK OR BOOM MIC. SWAPPED FIRST OFFICER AND OBVS AUDIO PANEL OBVS AUDIO PANEL INOP. REPLACED AUDIO PANEL, OPS CHECKED GOOD.Jul 27, 2011 · N672UA · Boeing 767322 · Audio Integrating SystemSDR UALA2011072803894Actuator · leakingNR 1 ENG VSV ACT HAS HISTORY OF FLUID LEAKS. NEED TO REPLACE THE VSV. REPLACED PER MM.Jul 27, 2011 · N657UA · Boeing 767322 · Compressor Bleed ValveSDR UALA2011072703863Switch · faultyDUE TO A PREVIOUS GRIPE OF RT IDG VALVE STATUS MESSAGE, REMOVE CONNECTOR, PULLED RT ENG IDG VALVE CB. REMOVED AND REPLACED NR 1 ENG IDG AIR-OIL HEAT EXCHANGER VALVE OVERRIDE SWITCH PER MM. IDLE RUN FOR 5 MINUTES NO STATUS MESSAGES.Jul 27, 2011 · N666UA · Boeing 767322 · AC Generator-AlternatorSDR UALA2011072703855Warning Light · illuminatedLEFT HYD QTY INDICATION.Jul 27, 2011 · N657UA · Boeing 767322 · Hydraulic Indicating SystemSDR UALA2011072703877Cover · unsecureMETAL CLIP HANGING DOWN BELOW RIGHT ENGINE. REMOVED LANYARD AND CLIP THAT HAD BROKEN OFF OF IDG OVERFLOW DRAIN COUPLING COVER, COVER STILL SECURE. SAMC REMARKS: CLOSED AND SECURED IDG ACCESS DOOR ON LEFT CORE COWL AFTER REMOVING LANYARD.Jul 26, 2011 · N669UA · Boeing 767322 · Nacelle/Pylon Miscellaneous StructureSDR UALA2011072703875Indicator · failedDURING FUELING LOST POWER TO UNDER WING FUEL STATION. AFTER RESET RIGHT TANK GAUGE FAULTED. DEFERRED RIGHT TANK UNDERWING FUEL GAUGE INOP PER MEL 2841G. REPLACED RIGHT UNDER WING GAUGE.Jul 26, 2011 · N659UA · Boeing 767322 · Fuel Indicating System
Back to Boeing 767-322