SDR UALA2011071303537Skin · dentedDURING ACFT LOADING HAD IMPACT AT DOOR 2L. STATION IS 46 BETWEEN 1540 TO 1562 AND STRINGER LOC IS APPROX S22 TO S23. DIMENSIONS OF THE DENT ARE (INCHES): LENGTH 3.5 WIDTH 2.75 AND DEPTH 0.0858. THE DENT IS SMOOTH WITH NO SHARP EDGES CUTS OR CREASE, ADJACENTSDR UALA2011071203494Actuator · looseNO LAND 3 & LEFT AUTO PILOT INOPERATIVE. ACCOMPLISHED MCDP BITE, LAST FLT FAULTS SHOWS "AIL SRVO-FCC L. FLIGHT CONTROL COMPUTER NIS EZEJL, PCN 481-9097. INSTALLED FCC PER MM, NO HELP. STILL FAILING "AIL SERVO FCC L. RMV'D LEFT UPPER LCCA. NEW LCCA IN PLSDR UALA2011071303538Skin · dentedDENT ON LOWER FUSELAGE IN LINE WITH AFT OPENING OF BULK CARGO DOOR AND SKIN IS ROUGH SMALL SCRATCH BURNISHED OUT AND CLEANED UP AND APPLIED ALODINE TO AREA PER SRM.SDR UALA2011071103443Module · faultyINTERMITTENT STAB TRIM EICAS AND STAB TRIM LIGHT ON OVERHEAD. REPLACED R SAM PER MM, GROUND CHECK NORMAL.SDR UALA2011071203495Access Panel · leakingCONTINUOUS FUEL SEEP FROM LT DRAIN INBD OF NR 1 ENGINE. FUEL IS POOLING IN THE LT DRY BAY. CONTINUOUS FUEL SEEP FROM LT DRAIN INBOARD OF NR 1 ENGINE. FOUND FUEL LEAKING FROM UPPER FWD INBD ANGLE OF DRY BAY. REPAIRED SEALANT. LEAK CHECKED LEFT WING DRY BAY ANSDR UALA2011071103445Pump · leakingEVIDENCE OF HYD LEAK FROM RT MAIN WHEEL WELL LOWER CTR LINE. FOUND THE CTR ELEC HYD PUMP 1 LEAKING. REMOVED CTR PUMP 1 PER MM. REPLACED C1 PUMP PER MM. NO LEAKS.SDR UALA2011071103463Control Valve · faultyDURING BITE TEST OF LEFT PACK CONTROLLER TEMP CONTROL VALVE LIGHT ILLUMINATED. REPLACED LEFT PACK TEMP CONTROL VALVE, OPS CHECK NORMAL.SDR UALA2011071103462Heat Exchanger · damagedLT PACK SECONDARY HEAT EXCHANGER BOTTOM FWD END HAS PIECE BROKEN OFF. STARTED HEAT EXCHANGER CHANGE. STOPPED AT STEP (F). REMOVED PRIMARY, SECONDARY HEAT EXCHANGERS AND PLENUM FOR ACM AS AN ASSEMBLY. NEED TO COMPLETE INSTALLATION. ACCOMPLISHED UP TO AND INSDR UALA2011071203488Eec · faultyENGINE IDLE DISAGREE EICAS AFTER LANDING LEFT ENG FF 2000 LBS AND RT ENG FF 1500 LBS. REPLACED LT EEC PER MM.SDR UALA2011071103444Eec · faultyENGINE IDLE DISAGREE EICAS AFTER LANDING. LT ENG FF 2000 LBS AND RT ENG FF 1500 LBS. REPLACED LT EEC PER MM.SDR UALA2011071103460Actuator · leakingHYD LEAK AT RT OUTBOARD AILERON. REPLACE OUTBOARD AILERON INBOARD ACTUATOR. NEED TO COMPLETE INSTALLATION OF NEW ACTUATOR (INBOARD POSITION). BEGIN AT MM. REPLACED ACTUATOR IAW MM.SDR UALA2011071103434Window · crackedCAPTAIN'S WINDSHIELD'S VISIBILITY IS IMPAIRED, REPLACEMENT IS REQUESTED. CREW COMMENTS: CRACKED COMPLETELY. REPLACED NR 1 CAPT WINDOW PER MM.SDR UALA2011071103446Control Valve · faultyRIGHT PACK 'AUTO' TEMPERATURE CONTROL SYSTEM(S) INOPERATIVE. DEFERRED PER SAMC. REPLACED TEMP CONTROL VALVE. PACK OPS NORMAL.SDR UALA2011071103467Actuator · faultySPOILER ON EICAS INTERMITTANTLY 2-3 TIMES DURING CLIMB. ALTITUDE WAS UPPER TEENS TO LOW 20S. REPLACED RUDDER TRIM ACTUATOR PER AMM AS CALLED OUT IN LM1108. TRIM INDICATOR READS 1 UNIT RT WITH RUDDER AT NEUTRAL AND RIG PIN R4 ALIGNED. REF AMM FOR TRIM INDICATSDR UALA2011071103459Display · faultyNR 1 HSI HAS A COLORED FRINGE ON THE DISPLAY (1=CAPT, 2=1ST OFF). REPLACED CAPT HSI. CHECKS GOOD.SDR UALA2011071103461Control Valve · faultyRT PACK TRIPPED ON TAKEOFF ROLL. REPLACED PACK CONTROLLER ALSO FOUND HOT AIR OUTLET B-NUT LOOSE, SECURED NUT AND GROUND CHECK NORMAL. RT PACK TRIPPED AGAIN ON TAXI OUT. ACCOMPLISHED BITE TEST REF MM. REPLACED 490 DEG SWITCH. UNABLE TO RUN PACK DUE TO OTHESDR UALA2011071103412Light · inoperativeEXTERNAL RT OVERWING SLIDE LIGHT BETWEEN OVERWING DOORS IS INOP. RELAMPED (1317), BUT NO HELP. PIGGYBACK POWER SUPPLY M731 BUT NO HELP -- UNPIGGYBACK. JUMPERED NEW LIGHT ASSY (WIRE MARKED NR 1 IS 6V PWR & THE OTHER WIRE IS GRND) AND IT WORKED. NEED TO REPLSDR UALA2011071103411Battery · dischargedEMER EXIT SIGN IN AISLE NEAR SEATS 17HJ INOP. REPLACED BATTERY AT M1209 AND OP CHECKED GOOD.SDR UALA2011071103458Transceiver · faultyF/O ADI SHOWS RADAR ALT FLAG. REPLACED RIGHT RA UNIT.SDR UALA2011071103456Audio Panel · faultyCAP VHF-L TRANSMIT BUTTON LIGHT INOP. REPLACED AUDIO SEL PNL PER MM, CAPT RADIO CHECK OK.SDR UALA2011070803399Light · missingSEAT 5B HAS EMERGENCY LIGHT MISSING. REPLACED SEAT LIGHT, OPS GOOD.SDR UALA2011070803398Light · inoperativeSEAT 6AB EMERGENCY LIGHTS DAMAGED INOP. REPLACED 2 EA SEAT LIGHT ASSYS, OPS GOOD.SDR UALA2011070803396Shutoff Valve · faultyGOT FWD EQ OVHT EICAS AND EQP COOLING PNL LIGHT. DID NOT SELF EXT HAD TO GO TO STBY. REPLACED EQUIPMENT COOLING INBOARD SHUTOFF VALVE PER FIM, ACCOMPLISHED OPS CHECK SYSTEM CHECKS NORMAL. CLEARED MESSAGE.SDR UALA2011071103449Indicator · faultyVIBRATOR FOR STANDBY ALTIMETER IS WAY TOO LOUD. CAUSES HEADACHES-FATIGUE. INTERFERES WITH ATC COMM. REPLACED INDICATOR CHECKED PER MM.SDR UALA2011070703381Hydraulic Line · leakingNR 2 ENGINE DRIVEN HYDRAULIC PUMP SUPPLY, RETURN LINES SHROUD SHOWS HYDRAULIC LEAK. LEAK APPEARS TO BE FROM PYLON ATTACHMENT LINES. PRESSURIZED NR 2 ENGINE DRIVEN HYDRAULIC PUMP AND NO LEAKS FOUND. CLEANED AREA OFF RESIDUAL LEAK.SDR UALA2011070703375Nut · missingINBOARD FLAP TRACK FAIRING FOUND BOLT LOOSE NUT MISSING FAIRING CRACKED AT 2 LOCATIONS, 2 INCHES LONG AT THE HINGE POINTS. REMOVED MID AN AFT FAIRING PER CDL 57H. REMOVED FAIRINGS ARE IN THE BULK PIT. OPERATION CHECK OF FLAPS ARE NORMAL. ACP VISUAL CHECK OSDR UALA2011070703371Actuator · faultyOUTFLOW VALVE INDICATES NOT FULLY OPEN DURING PREFLIGHT. CONTAINER FOR AA PART IS IN LOB CONTAINER IN PIT. REPLACED OUTFLOW VALVE GEARBOX ACTUATOR.SDR UALA2011070703363Connector · unsecureEEL EXIT SIGNS AND OVERHEAD AISLE LIGHTS INOP AFT RT SECTION. SECURED CONNECTOR ON PWR SUPPLY ASSY M734, CHECKS OKAY.SDR UALA2011070703362Light · inoperativeAFT SEAT MOUNTED EEL INOP AT SEAT 8AB. RELAMPED, OP NORMAL.SDR UALA2011070703389Controller · faultyAPU SHUT DOWN FAULT LIGHT ON. FOUND FAULTY CONTROLLER. REPLACED APU CONTROLLER UNIT. OPS ARE NORMAL.SDR UALA2011070603338Unknown · malfunctionedEQ COOLING OVERHEAT. EQ COOLING INTERMITTENT OVHT IN AUTO AND STANDBY MODES, OVERRIDE SYSTEM OPERATES NORMAL. ALL MODES OPS CHECKS GOOD ON GROUND.SDR UALA2011070603350Shutoff Valve · frozenLAV PROBLEM, FLIGHT DIVERTED. FOUND AFT WASTE TANK PRECHARGE SHUTOFF VALVE FROZEN IN CLOSED POSITION. NO PRESERVICE VLV STOCKED HNL. 585-5461. NEED TO ACP PRESERVICE OF AFT TANK PER MM. ADD PRECHARGE TO AFT WASTE TANK BY FLUSHING IT DOWN TOILET NEAREST THE SDR UALA2011070603335Servo · faulty'ELEV SERVO L FAIL' MSG ON MCDP AFTER TEST NR 8. COMPLETED MM FIM 22-00-03 PG 144 MCDP TEST NR 8. TRACED FAULT TREE TO PG 146 BLOCK 210, NEED TO REPLACE LEFT ELEVATOR AUTOPILOT SERVO M21. *NOTE, RPL LEFT FCC FOR TROUBLESHOOTING PER FIM, NO HELP. RE-INSTALLSDR UALA2011070603349Satcom · faultySATCOM LOW GAIN STATUS MESSAGE WON'T CLEAR. FOUND LGA HPA BITE FAILED. REPLACED LGA HPA PER MM. AFTER WARM UP WAS THEN FAULTING HGA HPA. REPLACED SDU PER MM. SYSTEM OPS CHECKS NORMAL PER MM.SDR UALA2011070603336Actuator · faultyNR 2 TCC MSG. TCC ACTUATOR MANUALLY ACTUATED, OPS NORMAL. NO DISCREPANCY WITH ELEC CONNECTOR. REPLACED TCC AIR VLV ACTUATOR PER MM.SDR UALA2011070603343Exhaust Valve · seizedRECEIVED NO EQUIP COOLING EICAS & LT ON FINAL AS ZERO DIFF PRESSURE REACHED. STBY OK ON TAXI IN. MAINT TEXT: FWD LOWER EQUIP COOLING EXHAUST VALVE IS SEIZED. INV CLASS (685-9211) REMOVED AND REPLACED FORWARD OVERBOARD VALVE PER MM, LEAK CHECK OKAY.SDR UALA2011070603348B-Nut · looseL ENG DRIPPING OIL ONE DROP PER 10 SECONDS. FOUND IDG 'B' NUTS LOOSE TIGHTEN LINE AND SERVICED IDG. DRY MOTORED ENG NO ACTIVE LEAK NOTED.SDR UALA2011070503313Light · missingSEAT MOUNTED 14AB HAS EEL LIGHTING MISSING. ALL OTHER EEL LIGHTING OKAY. REPLACED EEL LIGHT ASS'Y, OPS CHECKED OK.SDR UALA2011070503311Switch · stuckRT CENTER AUX PUMP LOW PRESSURE LIGHT FAILS TEST. LOW PRESSURE LIGHT WILL NOT ILLUMINATE. FOUND PRESSURE SW S424 STUCK IN PRESSURE POSITION WITH NO PRESSURE. FOUND CONTINUITY BETWEEN PINS 1-2 PINS 2-3 OPEN. REPLACED SWITCH PER MM, OPS CHECK OKAY.SDR UALA2011070503309Brake · damagedON WALKAROUND FOUND NR 5 BRAKE DAMAGED. BOTH WEAR INDICATOR PINS MISSING. REPLACED NR 5 BRAKE PER MM, LEAK CHECKED GOOD.SDR UALA2011070503322Controller · faultyAPU DUCT PRESSURE LOW DURING ENGINE START. APU SWITCH PLACARDED IN FD APUC HAS AN INTERNAL FAULT. REPLACED APU CONTROLLER. ACCOMPLISHED IGV CHECK, NO FAULTS NOTED.SDR UALA2011080103960Filter · defectiveAPU AUTO SHUTDOWN THREE TIMES. APU INOP GENERATOR FILTER FAULT. REPLACED LUBE AND GENERATOR SCAVENGE OIL FILTER PER MM. ALSO SERVICED OIL, ADDED 1 QT. RAN APU AND LEAK CHECKED FILTER, NO LEAKS NOTED. RAN APU FOR 45 MIN. APU DID NOT AUTO SHUTDOWN.SDR UALA2011070503318Pump · leakingHYD FLUID LEAKING FROM NR 2 ENG AFT CORE COWL. FOUND EDP LEAKING FROM HEAD FLANGE 3 DROPS A MIN. REPLACED NR 2 ENGINE HYD PUMP PER MM.SDR UALA2011070103266Actuator · defectiveCREW REPORT: C HYD SYS MAINT MSG. ELECT C1 PUMP PRESSURE IS 2690 PSI, C2 ELECT PUMP PRESSURE IS 2410 AND ADP PRESSURE IS 2990 PSI. REPLACED CENTER HYD PRESS TRANSMITTER, NO HELP. WITH CENTER WING HYD SHUTOFF VALVE OFF, ELEC HYD PRESSURES RETURNED TO ABOVE SDR UALA2011070103265Actuator · defectiveLEFT INBD AILERON INBD ACT REQUIRES REPLACEMENT. INSTALLED NEW ACTUATOR PER MM. SYSTEM WITHIN TOLERANCE.SDR UALA2011070103248Switch · faultyRIGHT CENTER TANK FUEL PUMP INOPERATIVE AND DEACTIVATED. REPLACED RIGHT CENTER TANK SWITCH, OPERATIONAL CHECK OF PUMP NORMALSDR UALA2011070103245Life Vest · missingADULT LIFE VEST MISSING 2R. REPLACED MISSING LIFE VEST.SDR UALA2011070103264Display · faultyCREW REPORTS ACARS INOPERATIVE. REPLACED ACARS MNG UNIT PER MM. REPLACED INTER DISPLAY UNIT FOR ACARS PER MM, OPS CK OKAY.SDR UALA2011070103231Relay · faultyLEFT AUX PITOT EICAS MESSAGE AND ASSOCIATED LIGHT AFTER ENGINE START. REPLACED THE CURRENT SENSING RELAY K312. ACCOMPLISHED TEST AT P61. TESTS OKAY.SDR UALA2011070103239Start Valve · faultyNR 1 ENG START VALVE WILL NOT OPEN USING COCKPIT START SWITCH. REPLACED OF LEFT ENGINE START SWITCH, NO HELP START VALVE DOES NOT OPERATE. REPLACE NR 1 ENG START VALVE AND RESEATED NR 1 ENG N2 SPEED CARD, ENG STARTS NORMAL AND START SWITCH OPERATION NORMAL.
Back to Boeing 767-322