Boeing 767-322
Service difficulty reports · 11,764
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011042702061Sliding Window · out of toleranceNR 2 CAPTAIN'S WINDOW REPLACED PER MM. REPLACED CAPTAINS SLIDING WINDOW PER MM.SDR UALA2011042501989Pcu · leakingHYD LEAK ON TAIL SECTION BELOW THE RUDDER. FOUND UPPER RUDDER PCU LEAKING BEYOND LIMTS. FOUND LEFT INBD AILERON PCA LEAKING 1 DROP EVERY 3 MINUTES. OK FOR SERVICE PER MM. NO MAINTENANCE ACTION REQUIRED. CLEANED AREA OF HYD FLUID.SDR UALA2011042602019Indicator · faultyL FUEL QTY READS A.6. CHRONIC. FUEL QTY INDICATOR FOUND DEFECTIVE. REPLACED COCKPIT FUEL QUANTITY INDICATOR AS PER FIM. UNIT WITHIN TOLERANCE.SDR UALA2011042602018Shutoff Valve · faultyRIGHT ENGINE DUCT PRESSURE CYCLES FROM 25-40 PSI IN DESCENT. RIGHT ENGINE HPSOV INOPERATIVE PER MEL. DECAY CHECK RT HPSOV SENSE LINE TO HPC-NO LEAKS, HPSOV OPENS AT 6-8 PSI WITH BLEED REG PRESSURE TESTER HOOKED UP, AIR SUPPLY BITE MODULE SHOWS RT HPC BITE SWITSDR UALA2011042602020Light · missingEEL STRIP LIGHT ON SIDE OF SEAT 6H MISSING. REPLACED MISSING EEL LIGHT STRIP AT 6H, CHECKS OKAY.SDR UALA2011042502017Oxygen Bottle · low pressurePSX PORTABLE OXYGEN CYLINDER(S) PRESS IS LOW OR ZERO. CREW COMMENTS: BOTTLE AT 2R USED. DF O2 BOTTLE INOP AT DOOR 2R DUE TO NO SPARE IN FRA. REPLACED O2 BOTTLE.SDR UALA2011042502013Bulb · inoperativeSMOKE LIGHT OVERHEAD PANEL NEEDS RELAMPING. "SMOKE" LIGHT ON EQUIPMENT COOLING PANEL WILL NOT COME ON WITH LIGHT TEST SWITCH. ACCOMPLISHED OPERATIONAL TEST AND TEST IS GOOD. "SMOKE" LIGHT COMES ON AND EICAS "FWD EQUIP SMOKE" ALSO DISPLAYED. LIGHT CAP (563-3SDR UALA2011042502012Packing · damagedLEFT AIR DRIVEN HYDRAULIC PUMP PRESSURE LINE LEAKING. REPLACED PACKING AT UNION TO PUMP BODY. OP CHECKS NORMAL.SDR UALA2011042502000Battery Pack · dischargedNO TEST 1 ON EMERGENCY ESCAPE SLIDE TEST. LIGHT PRESS TO TEST OKAY. REPLACED BOTH SLIDE BATTERY PACKS.SDR UALA2011042501983Shutoff Valve · leakingR HYD QUANTITY SHOWS RF.71. CONFIRMED RT TAIL SHUTOFF VALVE LEAKING. REMOVED AND REPLACED RT TAIL SHUTOFF VALVE AS PER AMM. RT TAIL SHUTOFF VALVE OPERATIONAL CHECK AND LEAK CHECK CARRIED OUT SATISFACTORY.SDR UALA2011042501972Anti-Ice Valve · malfunctionedRT ANTI-ICE VALVE REMAINED OPEN FOR TWO MINUTES AFTER VALVE SELECTED OFF. REPLACED RIGHT ENGINE INLET THERMAL ANTI-ICE VALVE PER MM.SDR UALA2011042502007Wire · brokenNR 3 F/O SLIDING WINDOW HEAT INOPERATIVE. AND FOUND BAD CONNECTOR PLUG. WIRE BROKEN AT F-O'S SLIDING WINDOW TERMINAL D1906 POS. D. WIRE CAPPED. NO PART AT IAD. REPLACED WINDOW TERMINAL PLUG ASSY. OPS CHECKED GOOD.SDR UALA2011042201950Panel · damagedTHE "A" PILLAR BETWEEN FWD WINDSHIELD & SLIDING WINDOW IS COMING APART BY HANDLE PRODUCING SHARPNESS. THE "A" PILLAR PADDING AT HANDLE IS DAMAGED AND FOAM IS EXPOSED, INTERIM REPAIR WITH TAPE PADDING IS SERVICEABLE. REPLACED CO-PILOT PANEL.SDR UALA2011042502006Wire · chafedSTATUS MSG R ENG FIRE LP 1. FOUND CHAFED WIRE BETWEEN UPPER AFT AND LOWER AFT LOOPS AT 9:00 POSITION. ACP TEMP RPR.SDR UALA2011042101926Shutoff Valve · faultyDUCT PRESS SPLIT DURING CLIMB L 11 PSI R 35 PSI AND DURING CRZ L 15 PSI R 25 PSI. REPLACED LEFT PRSOV PER MM. ACP'D ENG RUN PER JRH, BLEED SHIFT NORMAL, NO SPLIT NOTED.SDR UALA2011042101947Indicator · inoperativeRIGHT FUEL TANK UNDERWING FUELING PANEL INDICATOR INOP. REPLACED RIGHT FUEL TANK UNDERWING FUELING QUANTITY INDICATOR, OPS CHECK GOOD.SDR UALA2011042101925Wire · damagedCREW REPORTS: GOT A FUEL FILTER "STATUS" MESSAGE PASSING 5000FT. THIS IS A "STATUS" MSG ONLY NO EICAS MSG. SAMC TEXT: LEFT ENG FUEL FILTER, REPEAT WRITEUP REF PTT SEQ 1742007, REF AMM 73-34-00 FIG 103 PG 103 FOR FAULT ISOLATION, FUEL FILTER PCN 615-1695, PSDR UALA2011042101934Battery Pack · dischargedTWO EACH OVERHEAD EMERGENCY LIGHTS ARE INOP AT ROWS 25 AND 28. REPLACED EMERGENCY LIGHT POWER SUPPLY M732 BATTERY PACK PER AMM. FUNCTIONAL TEST GOOD.SDR UALA2011042001912Controller · faultyCREW COMMENTS: DURING CLIMB L 11PSI AND R 36PSI. IN CRUISE L15PSI AND R 25PSI. NEED TO CHK ALL MUSCLE LINES TO HPSOV, HPSOVC, PRV, PRVC, FAMV ON NR 1 ENG FOR LEAKS. CHECKED ALL MUSCLE LINES. NO LEAKS FOUND. REPLACED PRV CONTROLLER PER MM. DECAY CHECK ONSDR UALA2011042001910Oil Filter · defectiveDUE TO FINDING OF CARBON BUILD UP ON MAIN OIL FILTER NEED TO ACCOMPLISH AMM. EXAMINED LT ENG CHIP DETECTORS AND MAIN OIL FILTER. NO CHIPS FOUND. REPLACED MAIN OIL FILTER AND LEAKED CHECKED. NO LEAKS FOUND. ACP AMM FOR LEFT ENGINE. LEFT ENGINE RUNUP AND LSDR UALA2011042101933Light · inoperativeEEL LIGHT IS INOP AT SEAT 26B. REPLACED EEL LIGHT AT SEAT 26AB PER MM.SDR UALA2011042101932Controller · failedNR 2 ENG PRC FAILED HEALTH CHECK STEPS 5Q THRU U. REMOVED AND REPLACED PRC VALVE ON THE NR 2 ENG IAW B767-300 AMM. OPS CHECK GOOD. USED OHM METER 13230064 CAL DUE DATE 08-05-2011.SDR UALA2011041801877Battery Pack · faultyEMERGENCY PATH LIGHTS ON SEATS AND BELOW EXIT SIGN ON RIGHT SIDE OF A/C GO ON-OFF, ROW 20 TO 27. REPLACED BATTERY PACK. OPS CHECK OK.SDR UALA2011041801870Sensor · faultyECAM R BLD DUCT LEAK. *SUPPLEMENTAL DATA UPDATE* RT DUCT LEAK LIGHT CAME ON AFTER FLAPS LOWERED TO 15 DEGREE EXTENSION DURING ENGINE RUNUP. FOUND BAD DUCT LEAK SENSOR TS216 CAUSING DUCT LEAK LIGHT TO COME ON. REPLACED SENSOR AND RAN ENG WITH NO MSG OR DUCTSDR UALA2011041801860Radome · damagedFUSELAGE INCURRED LIGHTNING STRIKES. REPLACED RADOME.SDR UALA2011041801893Microphone · intermittentMIKE ON F/O OXYGEN MASK INTERMITTENT. INTERMITTENT COM. LAST MINUTE CALL, SWAPPED F/O'S WITH 2ND OBSERVERS O2 MASK. ADJ COM CONNECTOR ON 2ND OBSERVERS O2 MASK, OPS CHECK GOOD.SDR UALA2011041801874Audio Panel · faultyCAPT AUDIO PANEL INTERMITTENTLY INOP. LOUD STATIC WITH ALL VOL CONTROLS OFF. UNABLE XMIT-REC. REPLACED AUDIO SELECT PANEL. OPS CHECK GOOD.SDR UALA2011041801873Panel · faultyNR 1 VHF COMM CNTRL PNL HAS MECHANICAL DEFECT: BROKEN, MISSING OR LOOSE PARTS. (01=L VHF, 02=R VHF). REPLACED NR 1 COMM PANEL, ALL OPS CHECK SATISFACTORY.SDR UALA2011041801871Slide · deployedPASSENGER DOOR 2R ESCAPE SLIDE RAFT REMOVED FOR DEPLOYMENT. NEEDS TO BE RE-INSTALLED AND SOLD TO INSPECTION PER MM. REPLACED SLIDE PER MM.SDR UALA2011041801881Fseu · faultyFLAP-SLAT ELEC STATUS AND TRAILING ASYMMETRIC EICAS CAME ON WHILE SELECTING FLAPS 5. REPLACED FLAP SLAP ELEC UNIT AND ASYMMETRY RELAY K351 IN P36. RAN FLAPS AND SLAPS UP AND DOWN SEVERAL TIMES. ALSO ACCOMPLISHED VISUAL INSPECTION ON T/E FLAP TORQUE TUBES, ASDR UALA2011041801864Light · missingSEAT 3H,J MISSING ONE EA EMERGENCY ESCAPE PATH LIGHT. LAMP IS ZERO BAL HNLJL NEED LAMP PCN 566-1373. 2EA 566-1373 (LAMP ASSY) IN HNLJLHB. 2EA 566-1373 (LAMP ASSY) ISSUED TO HNLMM. REPLACED SEAT MOUNTED EMER LIGHT.SDR UALA2011041801846Light · inoperativeFLIGHT DECK EMERGENCY LIGHT INOP. REPLACED LIGHT ASSY, OP CHECKS NORMAL.SDR UALA2011041801845Cable · disconnectedPER A-CHECK SEAT 25AB EEL INOPERATIVE. FOUND SEAT CABLE DISCONNECTED, SECURED CABLE OP CHECK NORMAL.SDR UALA2011041501810Control Panel · defectiveNR 1 VHF COMM CONTROL PANEL HAS MECHANICAL DEFECT; BROKEN, MISSING, OR LOOSE PARTS. (01=L VHF, 02=R VHF). LT SIDE OF LT VHF COMM FREQ DISPLAY HAS VERY DIM ALMOST MISSING SEGMENTS. REPLACED VHF CONTROL PANEL, OP CKS NORMAL.SDR UALA2011041801886Pump · defectiveNR 1 ENG FUEL PUMP NEEDS TO BE OP AND LEAK CHECKED. FUEL PUMP CHANGED BY AMT. PERFORM IDLE RUN TO OPS CHK FUEL FILTER CONNECTOR NR 1 ENGINE. ACP'D FIVE MINUTE IDLE NR 1 ENGINE, OPS CHK OKAY. NO MESSAGES.SDR UALA2011041501842Connector · looseNR 1 ENG MAIN FUEL FILTER SENSOR CANNON PLUG IS LOOSE. REPLACED CONNECTOR D10996.SDR UALA2011041501809Actuator · faultyAFTER GEAR RETRACTION WHEN HANDLE SELECTED TO OFF, LDG GEAR MONITOR EICAS MSG AND AIR NOISE AND VIB. GEAR SELECTED TO UP NOISE AND VIB CLEARED. REPLACED NOSE GEAR LOCK ACTUATOR PER MM, CYCLED GEAR AND OPS NORMAL.SDR UALA2011041401808Actuator · faultyAFTER PUSH AILERON LOCKOUT EICAS MESSAGE. FOUND LEFT SAM HAD LEFT AILERON ACT FAULT. RESET AND DID NOT RETURN. FOLLOWED LM8279 AND REPLACED RIGHT SAM. UPON RETEST LEFT SAM FAULTED LEFT ACTUATOR. INSTALLED NEW SAM IN LEFT SIDE AND ORIGINAL BACK IN RIGHT. RETESSDR UALA2011041801872Audio Panel · faultyNR 3 AUDIO SEL PNL PUSH-TO-TALK SW IS DEFECTIVE. (03=CAPT, 04=1ST OFF, 5=1ST OBS). CREW COMMENTS: INTERMITTENT. REPLACED THE CAPT'S ASSEMBLY.SDR UALA2011041501817Circuit Card · faultyRTBL, RT ENG SPEED CARD STS MSG WITH ENGINE RUNNING. FOUND POPPED CB "D24" (ENGINE SPEED SENSE R1) ON P11-4 PANEL, CB WILL NOT RESET. REPLACED N2 SPEED CARD PER MM.SDR UALA2011041501811Module · faultyCONTROL STAND STAB TRIM INDICATION. COCKPIT TRIM INDICATOR DIFFER BY 1-2 UNIT C=5.0 FO=4.5. CHECKED IAW MM. FAULTY IND ITS THE F/O THATS FAULTY, DEFFERED IAW MEL. REPLACED F-O TRIM IND PER MM, NO HELP. RIGHT STAB TRIM POSITION MODULE REPLACED, OP CKS OKAY.SDR UALA2011041301792Rod · misinstalledWHEN CHANGING RT REAR TIRE ON RT MLG FOUND BRAKE ANTI ROTATION ROD ATTACH HARDWARE DAMAGED FROM BEING INSTALLED IMPROPERLY. REPLACED BRAKE ROD PER AMM.SDR UALA2011041501821Latch · corrodedRT OW SLIDE DOOR LATCH TEST FAILED. FOUND CORROSION IN LATCHES. REQ'D TO RPL LATCHES PER MM. RPL'D ALL RT OFF WING SLIDE DOOR LATCHES PER MM.SDR UALA2011041501815Indicator · intermittentRT MAIN FUEL IND AND TOTAL INTERMITTENT. REPLACED COCKPIT FUEL QTY INDICATOR PER MM, OP CHECKS GOOD.SDR UALA2011041301782Light · missingSEAT 25H AISLE ARMREST EMERGENCY LIGHT STRIP MISSING. REPLACED LIGHT STRIP ASSY. OPERATION CHECK OKAY.SDR UALA2011041301793Cowling · damagedNR 1 ENGINE LT SUPPORT COWLING, FWD SEAL WORN AND LOOSE. REMOVED OLD RUB STRIP AND CUT TO FIT NEW RUB STRIP. REPLACED NR 1 ENGINE LT CORE COWL PER AMM.SDR UALA2011041201764Control Valve · faultyLEFT PACK OFF LT. DEPARTURE TIME WHEN NOTED. NO PACK OFF EICAS MESSAGE WHEN TURNED OFF. REPLACED PACK FLOW CONTROL VALVE PER AMM.SDR UALA2011041201763Structure · crackedON WALK AROUND, FOUND 6" CRACK ON FUSELAGE BTWN STA 1654.5 AND STA 1678 AT STRINGER S13R. CRACK IS UNDER STRINGER AND CLOSER TO STA 1654.5. REMOVED 10 RIVETS FROM STRINGER S13R. REMOVED 8 RIVETS FROM BUTT JOINT AND STOP DRILL CRACK.SDR UALA2011041101754Light · inoperativeEMERGENCY LIGHT STRIP AT AFT LT MED NEAR LAV INOP. REPLACED EMERGENCY LIGHT PER WDM, OP CHECKS GOOD.SDR UALA2011041101753Wire · damagedEMERGENCY LIGHT AT SEAT 12AB INOPERATIVE. REPAIRED WIRING UNDER SEAT 12AB PER WDM, OP CHECKS GOOD.
Back to Boeing 767-322