SDR 2008UALA02955Light · brokenREF SMC001 ON EEL STRIP BROKEN, NEW STRIP IS IN PLACE AND WILL REQUIRE SPLICING AND RE-ASSEMBLY OF EEL STRIP CABLE PROTECTIVE COVERS AND CARPET. FOUND LIGHT ASSEMBLY BROKEN. SPLICED IN SECTION OF EEL LIGHT ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02925Connector · dirtyRIGHT HYDRAULIC SYSTEM PRESSURE FAILURE. RT HYD SYS PRESS LIGHT & RT HYD SYS ELEC DEMAND PUMP PRESS LIGHT ALONG WITH BRAKE SOURCE LIGHT ALL. VERBAL REPORT FROM FLT CREW. EVERYTHING NORMAL ON REST OF FLT. MOTORED RT ENG & OPERATED RT ELEC HYD PUMP. UNABLE TOSDR 2008UALA02944Aspirator · leakingASPIRATOR LEAKING. SUSPECT FAULTY O-RING. REPLACED ASPIRATOR. AC OK FOR SERVICE.SDR 2008UALA02909Light · missingEMERGENCY LIGHT ON 3H MISSING. FOUND LIGHT ASSEMBLY BROKEN. REPLACED LIGHT ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02908Light · inoperativeSEAT 1H, ONE SEAT MOUNTED ELECTROLUMINESCENT LIGHT HANGING OUT OF SEAT. LIGHT ALSO INOP. FOUND BROKEN LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY AT SEAT 1H. AC OK FOR SERVICE.SDR 2008UALA02907Light · inoperativeRIGHT AFT LAV EEL LIGHT BAR IS INOP. SUSPECT BROKEN LIGHT ASSEMBLY. REPAIRED RT AFT LAV EEL LIGHT BAR IAW GNMM 20-51-005 AND OPS CHECKED GOOD IAW MM 33-51-10. AC OK FOR SERVICE.SDR 2008UALA02906Light · inoperativeLEFT MID LAV EEL LIGHT BAR IS INOP. SUSPECT BROKEN LIGHT ASSEMBLY. REPAIRED LT MID LAV EEL LIGHT BAR IAW GNMM 2-0-15-005 OPS CHECKED GOOD IAW MM 33-51-00. AC OK FOR SERVICE.SDR 2008UALA02869Light · damagedEMERGENCY LIGHTS IN FLOOR LOOSE RIGHT SIDE ACROSS FROM BUSINESS GALLEY. FOUND DAMAGED LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY. AC OK FOR SERVICE.SDR 2008UALA02882Skin · dentedRT WING INBD FLAP T/E IS DENTED. REPAIRED IAW GN-6-0-2-19. AC OK FOR SERVICE.
SDR 2008UALA02868Light · malfunctionedEMERGENCY FLOOR LIGHTING INOP WHEN ACTUATED FROM CABIN. CARRIED OUT TROUBLESHOOTING PER MM AND ACTIONED OPS TEST OF EMERGENCY ESCAPE PATH LIGHTING EEL SYSTEM PER MM 33-51-00 PAGE 503-504, SATIS. AC RELEASED FOR SERVICE.SDR 2008UALA02880Power Supply · dischargedRIGHT AFT OVERWING EXTERIOR EMERGENCY LIGHT IS INOP. SUSPECT POWER SUPPLY. REPLACED POWER SUPPLY. OPS CHECKS GOOD, AC OK FOR SERVICE.SDR 2008UALA02879Battery Pack · missingEMERGENCY POWER SUPPLY MISSING (M1209) FOR RT FWD WING EXIT DOOR (VERTICALLY MOUNTED). SUSPECT BATTERY PACK IMPROPERLY INSTALLED. REPLACED BATTERY PACK PER MM 33-51-07. OPS CHECKS GOOD. AC OK FOR SERVICE.SDR 2008UALA02815Shear Tie · corrodedCORROSION ON SHEARTIE AT STA 1219, STR 37L TO 38L. MAJOR REPAIR ACCOMPLISHED: REPLACED SHEAR TIE.SDR 2008UALA02817Rudder · damagedRUDDER DAMAGED ON TRAILING EDGE BY MANLIFT OPERATION, APPROX .25 INCH DEEP BY 6 INCH LONG. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA. INSTALLED LAY-UP REPAIR.SDR 2008UALA02816Torque Tube · corrodedCORROSION ON TORQUE TUBE BETWEEN STA 1263 AND STA 1285 AND STA 1285 AT LBL 6 TO RBL 16 IN AFT PIT. MAJOR REPAIR ACCOMPLISHED: REPLACED WEB.SDR 2008UALA02792O-Ring · leakingLOW BOTTLE PRESSURE. BOTTLE TO VALVE O-RING LEAKING. REPLACED O-RING.SDR 2008UALA02774Proximity Sensor · out of adjustL/E SLAT ASSY PROBLEM AFTER FLAPS RETRACTED. RTFL. PROXIMITY SENSOR S285 OUT OF LIMITS. ADJUSTED SENSOR.SDR 2008UALA02790Circuit Card · faultyFWD EQUIPMENT VAL EICAS MSG ON WHILE TAXIING OUT. SUSPECT EQUIPMENT COOLING CARD. REPLACED EQUIP COOL CARD IN P50 PNL M867, RAN ENGINES OPS NORMAL. AC OK FOR SERVICE.SDR 2008UALA02791Aspirator · leakingLEAKING ASPIRATOR. SUPPLEMENTAL DATA UPDATE, POSSIBLE MANUFACTURER DEFECT. REPLACED ASPIRATOR.SDR 2008UALA02768Fmu · malfunctionedSLOW TO SPOOL TO IDLE ON NR 1 ENG, WHEN EEC CHANNEL 'B' WAS IN CONTROL. REPLACED THE FUEL METERING UNIT (FMU).SDR 2008UALA02710Control Valve · malfunctionedLEFT PACK FLOW CONTROL VALVE WILL NOT OPEN. AFTER TROUBLE SHOOTING FOUND FLOW CONTROL, SHUTOFF VALVE FAULTY. REPLACED LT PACK FLOW CONTROL VALVE. OPS CHECKED GOOD.AC OK FOR SERVICE.SDR UALA2008111302712Fcu · faultyRTBL WITH A AUXILIARY POWER UNIT DOOR MESSAGE. RECURRED ON FLT 0907-11. REPLACED FUEL CONTROL UNIT. ACCOMPLISHED INSPECTION AS PER MM. ALL OPS AND INDICATIONS NORMAL, LEAK CHECK GOOD. ACCMP VERIFICATION FLIGHT.SDR 2008UALA02712Warning System · activatedRTBL WITH A AUXILIARY POWER UNIT DOOR MESSAGE. REOCCURRED ON FLT 0907-11.SDR 2008UALA02727Bracket · brokenON WALK AROUND, FOUND FRONT END OF LT GEAR BOGIE LOWER TRAY DAMAGED 4 RIVETS BROKEN AND 1 INCH CRACK ON MOUNTING BRACKET, BRACKET BEND. INSTALLED NEW FWD MOUNT BRACKET AND STRAIGHTENED LOWER TRAY. AC OK FOR SERVICE.SDR 2008UALA02726Control Valve · malfunctionedLEFT PACK WILL NOT TURN OFF. SUSPECT FAULTY FLOW CONTROL SHUTOFF VALVE. REPLACED LT PACK FLOW CONTROL AND SHUTOFF VALVE. OPERATIONAL CHECK IS GOOD. AC OK FOR SERVICE.SDR 2008UALA02704Pump · overheatedRIGHT HYDRAULIC SYSTEM OVERHEAT PROBLEM CAUSED FLIGHT DIVERSION. REPLACED RT EDP. NO SHOP RECORD FOUND. ROOT CAUSE UNKNOWN.SDR 2008UALA02693Hose · collapsedRIGHT OVERWING SLIDE INFLATION HOSE COLLAPSED. SUSPECT AC MAINTENANCE. REPLACED HOSE ASSEMBLY. AC OK FOR SERVICE.SDR 2008UALA02702Actuator · faultyRUDDER TRIM FAILED TO TRIM IN EITHER DIRECTION. SUSPECT FAULTY ACTUATOR. REPLACED RUDDER TRIM ACTUATOR IAW MM 27-21-11. AC OK FOR SERVICE.SDR 2008UALA02689Fairing · crackedLEFT WING FLAP MOST INBOARD FAIRING ON MID FLAP HAS TWO EACH CRACKS. SUSPECT GROUND EQUIPMENT DAMAGE REMOVED FAIRINGS SENT TO SHOP 272 FOR REPAIR. REINSTALLED FAIRINGS. AC OK FOR SERVICE.SDR 2008UALA02686Shear Tie · corrodedCORROSION ON SHEAR TIE IN BILGE AT STA 1197.66, BETWEEN STR 39L AND 39R. MAJOR REPAIR ACCOMPLISHED: INSTALLED NEW SHEAR TIE.SDR 2008UALA02675Spring · faultyDEPLOYMENT BAR SNUBBER DOES NOT RETRACT BAR ON L1 DOOR. SUPPLEMENTAL DATA UPDATE, REPLACED GAS SPRING. OPS CHECKS GOOD.SDR 2008UALA02674Spring · defectiveR2 DOOR FWD DEPLOYMENT CABLE RETRACTOR STICKS, CABLE DOES NOT RETRACT. REPLACED GAS SPRING. OP CHECKS GOOD.SDR 2008UALA02677Connector · looseEEL AISLE IN FRONT OF ROW 15CDEF INOP. FOUND LOOSE CONNECTION. SECURED CONNECTION OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02676Light · faultyEEL LIGHTS FLASH BETWEEN ROWS 15AB THRU 19AB. COULD NOT DUPLICATE PROBLEM. EEL LIGHTS OPS CHECKS OK.AC OK FOR SERVICE.SDR 2008UALA02673Line · leakingLEFT HYDRAULIC QTY BELOW RF (.72). FOUND PRESSURE LINE AT RH WING OUTBOARD SPOILER LEAKING REPLACED LINE WITH FLEX LINE PER GNMM 1-0-13-003 OPS AND LEAK CK OK. AC OK FOR SERVICE.
SDR 2008UALA02665Isolation Valve · unknownRIGHT ENGINE ISOLATION ISLN VALVE WON`T OPEN.SDR 2008UALA02664Starter · faultyDURING LEFT ENG START N2 DROPPED BELOW 20 PRIOR TO ADDING FUEL TUG ADVZD SPARKS AND FLUID. SUSPECT FAULTY STARTER. REPLACED STARTER & START VALVE. OP CHECKS GOOD. OK FOR SERVICE.SDR 2008UALA02659Frame · corrodedCORROSION UNDER NUTPLATE ON THE UNDERSIDE OF THE BILGE FRAME T-CAP AT BS 1197+132, LBL 18. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION. INSTALLED STRAP & ANGLE REPAIR.SDR 2008UALA02658Shear Tie · corrodedCORROSION ON SHEAR TIE AT BS 1197+132, BETWEEN STR 38L-39L. MAJOR REPAIR ACCOMPLISHED: INSTALLED NEW SHEAR TIE.SDR 2008UALA02657Shear Tie · corrodedCORROSION ON SHEAR TIE AT BS 1197+132, BETWEEN STR 39R-39L. MAJOR REPAIR ACCOMPLISHED: REPLACED SHEAR TIE.SDR 2008UALA02656Shear Tie · corrodedCORROSION ON SHEAR TIE AT STA 1241, STR 38 TO 39L. MAJOR REPAIR ACCOMPLISHED: REPLACED SHEAR TIE.SDR 2008UALA02655Shear Tie · corrodedCORROSION ON SHEAR TIE STA 1241, STR 39L TO 39R. MAJOR REPAIR ACCOMPLISHED: REPLACED SHEAR TIE.SDR 2008UALA02654Shear Tie · corrodedCORROSION ON SHEAR TIE AT STA 1241, STR 38R TO 39R. MAJOR REPAIR ACCOMPLISHED: REPLACED SHEAR TIE.SDR 2008UALA02653Shear Tie · corrodedCORROSION ON SHEAR TIE AT BS 1197+132, BETWEEN STR 38R-39R. MAJOR REPAIR ACCOMPLISHED: REPLACED SHEAR TIE.SDR 2008UALA02650Spar · crackedNR 2 PYLON UPPER SPAR WEB IS CRACKED AT OTBD DRAIN HOLE, NAC STA 156. MAJOR REPAIR ACCOMPLISHED, ACCOMPLISHED HFEC AND FOUND 2 CRACKS APPROX .5 INCH LONG. STOP DRILLED CRACKS. FABRICATED AND INSTALLED A REPAIR DOUBLER.SDR 2008UALA02647Connector · chafedRIGHT GENERATOR OFF LINE. RTFL ORD. REPLACED CONNECTOR. WIRES FROM CONNECTOR WERE CHAFED AND SHORTED AGAINST THE BACKSHELL.SDR 2008UALA02617Switch · inoperativeRTFL DUE TO DOUBLE TRANSPONDER FAILURE. RPLACED ATC ANTENNA SWITCH.SDR 2008UALA02604Panel · missingTEN INCH SQUARE SECTION OF PANEL MISSING FROM UNDER LT WING ABOVE MAIN GEAR. ACP TEMP REPAIR PER EVA 71522 .100 FILLER AND .100 DOUBLER. ACCOMPLISH INSPECTION OR RECHECK AS REQUIRED IN CF0477. AC OK FOR SERVICE.SDR 2008UALA02603Valve · malfunctionedFWD EQUIPMENT VALVE EICAS MSG ON LANDING. FOUND OVERBOARD VALVE AND COOLING CONTROL PANEL FAULTY. REPLACED FORWARD OVERBOARD VALVE, AND EQUIPMENT COOLING CONTROL PANEL. OP CHECKS NORMAL. AC OK FOR SERVICE.SDR UALA2008111302618Connector · dirtyAPU AUTO SHUT DOWN. REMOVED & CLEANED FUEL CONTROL UNIT CONNECTOR. APU STARTS AND RUNS NORMAL.