What was found
NR 2 PYLON UPPER SPAR WEB IS CRACKED AT OTBD DRAIN HOLE, NAC STA 156. MAJOR REPAIR ACCOMPLISHED, ACCOMPLISHED HFEC AND FOUND 2 CRACKS APPROX .5 INCH LONG. STOP DRILLED CRACKS. FABRICATED AND INSTALLED A REPAIR DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 PYLON UPPER SPAR WEB IS CRACKED AT OTBD DRAIN HOLE, NAC STA 156. MAJOR REPAIR ACCOMPLISHED, ACCOMPLISHED HFEC AND FOUND 2 CRACKS APPROX .5 INCH LONG. STOP DRILLED CRACKS. FABRICATED AND INSTALLED A REPAIR DOUBLER.