Boeing 767-322
Service difficulty reports · 11,768
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA03731Battery · inoperativeLEFT SIDE EEL IS INOP FROM SEAT 27 TO AFT GALLEY. REPLACED BATTERY & EEL CHECKS GOOD.SDR 2007UALA03708Lamp · inoperativeEEL LIGHTS INOP RIGHT SIDE ROWS 15 THRU 27. 10-9-07 REPLACED SHORTED EEL LAMP. ALL EEL OP CHECKS OK.SDR 2007UALA03707Connector · disconnectedENTIRE FIRST CLASS EEL LIGHTS INOP LEFT SIDE AND X AISLE. 10-9-07 RECONNECTED AND SECURED FEEDER CONNECTOR.OPS CHECKED EEL LIGHTS, OK FOR SERVICE.SDR 2007UALA03698Floorbeam · crackedFLOORBEAM STA 246 VERTICAL STIFFENER LBL 40 CRACKED. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED DAMAGED STIFFENER.SDR 2007UALA03697Floorbeam · crackedE/E COMPARTMENT, FLOORBEAM AT STA 246, APPROX RBL 19 HAS A CRACK IN VERTICAL STIFFENER. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED CRACKED STIFFENER.SDR 2007UALA03693Light · inoperativeSHORT X AISLE EEL LIGHT IN AFT GALLEY INOP. 10-5-07 REPLACED SMALL 15 INCHER CROSS AISLE EMERGENCY LIGHT. STRIP IN AFT GALLEY SECTION.SDR 2007UALA03692Light · inoperativeEEL LIGHT AT LEFT AFT LAV INOP. 10-5-07 REPLACED 15" CROSS AISLE EEL SEGMENT IN THE AFT GALLEY. EEL CHECKED OK.SDR 2007UALA03691Light · inoperativeEMERGENCY EEL LIGHTS FROM ROW 28AB-35AB INOP. 10-5-07 FOUND SMALL SECTION AT AFT GALLEY LIGHT STRIP (15" CROSS AISLE) SHORTING OUT THE WHOLE SECTION. REPLACED 15 INCH CROSS AISLE EEL STRIP IN AFT GALLEY -- EEL LIGHTS CK OK 28AB THRU 35AB.SDR 2007UALA03690Feeder Cable · failedEMERGENCY EEL LIGHTS FROM ROW 5AB-14AB & AT LEFT MID LAV ARE INOPERATIVE. 10-5-07 REPLACED POWER SUPPLY FEEDER CABLE. OP CHECKS GOOD.SDR 2007UALA03689Lamp · inoperativeEMERGENCY CEILING LIGHT AT ROW 17AB INOP. 10-5-07 FOUND LAMP ASSY BROKEN. REPLACED LAMP ASSY. OP CHECK NORMAL.SDR 2007UALA03686Hose · damagedHOSE WAS FOUND DAMAGED DURING HOSE TEST. 10-5-07 HOSE WAS LEAKING THRU OUTSIDE SURFACE WITHOUT VISIBLE EVIDENCE OF DAMAGE. REPLACED HOSE. SLIDE AND AIRCRAFT OK FOR SERVICE.SDR 2007UALA03653Slat · damagedDAMAGE TO RIGHT LEADING EDGE SLAT BEYOND SRM LIMITS. 10-11-07 CREW REPORTED BIRD STRIKE ON RIGHT LEADING EDGE OF AIRCRAFT. CHK'D ENGINE FOR EVIDENCE OF INGESTION. NO DISCREPANCIES NOTED. NR 8 SLAT REMOVED FOR REPLACEMENT. AFTER CHECK, AIRCRAFT OK FORSDR 2007UALA03651Wire · damagedFWD GALLEY EEL LIGHT INOPERATIVE. 10-11-07 REPLACED LIGHT AND REPAIRED WIRING. EEL OP CHECKED OK FOR SERVICE.SDR 2007UALA03650Light · inoperativeFLIGHT DECK EMERGENCY LIGHT FAILS TO COME ON DURING TEST. 10-11-07 REPLACED EMERGENCY LIGHT ASSY. OP CHECKED OK .SDR 2007UALA03608Engine · surgesENG 2 SILENT SURGE DETECTED.SDR 2007UALA03607Warning Light · illuminatedGEAR DISAGREE LIGHT ILLUM WHEN GEAR WAS EXTENDED FOLLOWED BY TAIL SKID LIGHT.SDR 2007UALA03596Oxygen Mask · leakingCAPTS O2 MASK BOTTOM HARNESS TUBE IS LEAKING.SDR 2007UALA03557Oxygen Mask · defectiveOXYGEN MASK DEFECTIVE AT 2.(1=CAPT,2=1ST OFF,3=1ST OBS). CREW COMMENTS: O2 MASK INFLATABLE BAND BURST.SDR 2007UALA03562Light · inoperativeEEL LIGHT INOP LOCATED AT FIRST CLASS ZONE LEFT AISLE.SDR 2007UALA03561Light · inoperativeEEL LIGHT INOP LOCATED AT FIRST CLASS ZONE RIGHT AISLE.SDR 2007UALA03560Bezel · missingBEZEL IS MISSING FROM EEL LIGHT AT ROW 18 BC.SDR 2007UALA03559Cable · pulledEEL LIGHT CABLE PULLED OUT OF TRACK FWD OF SEAT 1E.SDR 2007UALA03558Light · inoperativeEEL LIGHT INOP LOCATED MID ZONE LAVATORY LEFT & RIGHT AISLES.SDR 2007UALA03563Idg · malfunctionedLEFT IDG VOLTS FLUCTUATING.SDR 2007UALA03537Warning System · activatedRTFL DUE TO L/E SLAT DISAGREE MESSAGE. EVENT RECURRED ON NEXT FLIGHT OUT.SDR 2007UALA03514Unknown · vibrationRTFL UNDER AMBER ALERT DUE TO NOSE LANDING GEAR VIBRATION ON TAKEOFF.SDR 2007UALA03614Light · inoperativeLEFT SIDE EXTERIOR EMERGENCY LIGHTS (L388): (L389): (L313 ): (L395): AND (L642) INOP.SDR 2007UALA03500Light · inoperativeMID GALLEY EEL STRIP & AFT GALLEY LARGE EEL STRIP ARE INOPERABLE.SDR 2007UALA03486Light · missingEEL LIGHT MISSING AT SEAT 2AB. REPLACED LIGHT ASSY, CHECKS OKAY.SDR 2007UALA03485Handle · obstructedRIGHT AFT EMERGENCY ESCAPE HATCH AUTO ARM AND AUTO FIVE SWITCHES DID NOT MOVE TO THE (UP) POSITION, DURING TEST.SDR 2007UALA03484Mechanism · out of positionLEFT OVERWING SLIDE INFLATION CYLINDER PULL FORCE MECHANISM BALL IS IN THE WRONG POSITION, BALL IS IN FRONT OF THE RETAINER SPRING, NOT BEHIND IT AS REQUIRED.SDR 2007UALA03483Latch · out of toleranceLEFT OVERWING SLIDE DOOR LATCHES NR 1, 2, 3 & 4 FAIL EDGE MARGIN TEST.SDR 2007UALA03467Bulkhead · gougedNR 1 PYLON, GOUGED BULKHEAD FITTING AT NAC STA 237.39. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA. CUT OUT PREVIOUSLY TRIMMED FLANGE FROM BULKHEAD (P/N 311T3281). FABRICATED A REPAIR ANGLE & A REPLACEMENT BRACKET (272T0082-28) & A REPLACEMENT CLIP (31SDR HALA0700357Terminal · brokenRIGHT ENGINE BLEED VALVE EICAS MESSAGE. REPAIRED BROKEN TERMINAL WIRES ON RIGHT HPSOV AS REQUIRED. HPSOV VALVE REMAINS LOCKED CLOSED. DMI REQUIREMENTS MET DMI CONTINUES.SDR 2007UALA03451Skin · damagedLEADING EDGE OF LEFT OUTBOARD ELEVATOR UPPER SURFACE IS CHIPPED ABOVE HINGE AT 240.SDR 2007UALA03450Skin · corrodedEXTERNAL FUSELAGE, STA 1554 BETWEEN STR 24L AND STR 25L, FWD LAV VENT, SKIN AROUND EXHAUST BULGED AND CORRODED. REPAIRED PER REO G12120 REV A AND EVA-70582. STARTING AT 37,500FC MUST ACP A DETAILED VISUAL INSP EXT AND INTERNAL AND A LFEC EXT SKIN AND MUST CSDR HALA0700356Pressure Switch · failedADP AUTO FUNCTION INOP, OPERATES NORMAL IN ON POSITION. ACCOMPLISHED FIM 29-11-00, FIGURE 109. REPLACED ADP CONTROL PRESSURE SWITCH S29 PER AMM 29-11-19. GROUND OPS AND LEAK CHECK OK. REMOVED PLACARD. CLEARED MIC SHEET. MOC NOTIFIED.SDR 2007UALA03403Compressor · stalledNR 2 ENG HAD A MODERATE TO LARGE COMPRESSOR STALL-BOOM AT STEADY STATE POWER SETTING OF 1.30 EPR. WIND 290-1 4 KTS. EICAS STATUS MSG GENERATED -R SURGE DET- MSG. NR 2 ENGINE SURGED REPEATEDLY ON GROUND RUNS. HPC BORESCOPE NOTED NO DEFECTS. ENGINE REPLACEDSDR 2007UALA03415Connector · damagedEEL STRIP CROSS AISLE AT 1R INOP. FIRST EEL STRIP AFT OF 1R INOP. FOUND PINS BROKEN OFF AT CONNECTION. NEEDS NEW EEL STRIP, OR SPLICE IN NEW PLUG. INSTALLED NEW EEL STRIP AT 1R, OPS NORMAL.SDR 2007UALA03412Oxygen Mask · leakingCAPTAIN'S OXYGEN MASK HEAD STRAPS LEAKS AIR WHEN INFLATED. REPLACED MASK PER MM 35-11 -51.CKS GOOD.SDR 2007UALA03366Structure · leakingLEFT MAIN FUEL QTY DECREASED WITH LT CENTER FUEL PUMP ON AND 30,000 LBS IN CENTER TANK. AFTER TROUBLESHOOTING, FOUND LT FUEL TANK DRY BAY HAS RUNNING FUEL LEAK. RESEALED LEAK AT BOTTOM STRINGER BETWEEN LEFT TANK AND OUTBOARD OF DRYBAY AT 1700. ACCOMPLISHED SDR 2007UALA03337Wire · damagedSEAT 31AB EEL LIGHT IS INOPERATIVE. REPLACED SEAT EEL WIRING. OP CHECKS OK.SDR 2007UALA03336Light · inoperativeFWD GALLEY EEL STRIP IS INOPERATIVE. REPLACED EEL STRIP. CHECKS OK FOR SERVICE.SDR 2007UALA03335Fastener · improper partREPAIR AT BS 294-303 AT STR 27L FOUND WITH BLIND FASTENERS. REMOVED BLIND FASTENERS AND REPLACED WITH SOLID FASTENERS.SDR 2007UALA03334Stiffener · crackedFLOORBEAM STA 246 VERTICAL STIFFENER CRACKED AT RBL 26 FWD SIDE. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED STIFFENER. INSTALLED NEW STIFFENER.SDR 2007UALA03333Stiffener · crackedFLOORBEAM STA 246 VERTICAL STIFFENER CRACKED AT RBL 12 FWD SIDE. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED STIFFENER. LOCATED, DRILLED & INSTALLED NEW STIFFENER.SDR 2007UALA03332Floorbeam · crackedFLOORBEAM STA 246 T-CAP ANGLE CRACKED AT LBL 12, AFT SIDE. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED SECTION OF CAP ANGLE. FABRICATED & INSTALLED ANGLE REPAIR.SDR 2007UALA03331Attach Bracket · crackedFLOORBEAM INTERCOSTAL ATTACH BRACKET CRACKED AT STA 303, BL 0. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED ANGLE. FABRICATED & INSTALLED NEW ANGLE.SDR 2007UALA03330Skin · dentedEXTERNAL FUSELAGE STA 1197+110 BETWEEN STR 39R AND 38L SKIN DENTED INSIDE OUT. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE. HFEC INSPECTION TO VERIFY DAMAGE REMOVAL. NO CRACKS FOUND. FABRICATED & INSTALLED FILLER AND DOUBLER.SDR 2007UALA03315Power Supply · dischargedEMERGENCY EEL LIGHT INOP FROM SEAT 31HJ TO 39 HJ. REPLACED BATTERY POWER SUPPLY.
Back to Boeing 767-322