SDR 2007UALA03279Indicator · faultyFLAP INDICATOR NEEDLES OUT OF LIMITS FOR FLAPS 5, 15 & 20. CHECKED FLAP POSITION TRANSMITTER NR 1 AND NR 8 RIGGING FOUND OK. CLEANED TRANSMITTER CANNON PLUGS. EXTENDED AND RETRACTED FLAPS SEVERAL TIMES USING NORMAL AND ALTERNATE MODES. BOTH IND. NEEDLES FOLSDR 2007UALA03278Strip · missingSEATS 2L & 3R ARE MISSING THE AFT EEL STRIP SECTION. INSTALLED LAMP ASSEMBLY IN BOTH SEAT POSITIONS. OP CHECKS OK.SDR 2007UALA03248Light · looseFOUND EEL STRIP AT SEAT 6AB INOPERATIVE. RECONNECTED LOOSE EEL STRIP, OP CHECKS OK.SDR 2007UALA03247Light · inoperativeFOUND RIGHT LAV AT MID GALLEY EEL STRIP INOPERATIVE. REPAIRED EEL STRIP, OP CHECKS OK.SDR 2007UALA03239Feeder Cable · inoperativeFLOOR MOUNTED EEL LIGHTS INOP, RT AISLE IN FIRST CLASS. REPLACED POWER STRIP IN FLOOR TRACK.SDR 2007UALA03235Valve · stickingA-C EXPERIENCING EQUIP COOLING FAULTS. V12 OVERBOARD EXHAUST VALVE FOUND TO BE STICKING IN THE PARTIALLY CLOSED POSITION. REPLACED V12 EXHAUST VALVE. DIDN'T SOLVE PROBLEM. :REMOVED & REPLACED EQUIPMENT COOLING OVERHEAT SWITCH. FOUND SUFFICIENT AIR SOURCE INSDR 2007UALA03245Feeder Cable · damagedFOUND EEL LIGHTS INOP MID LAV. REPAIRED EEL FEEDER CABLE. TESTS OK.SDR 2007UALA03244Battery Pack · inoperativeFOUND EEL LIGHTS INOP COACH RIGHT SIDE. REPLACED BATTERY PACK. TESTS OK .SDR 2007UALA03243Lamp · inoperativeFOUND AFT GALLEY RT EEL STRIP INOPERATIVE. REPLACED LAMP STRIP. TEST OK.SDR 2007UALA03246Light · damagedFOUND CONNOISSEUR CLASS EEL FLOOR RIBBON DAMAGED LEFT AFT SIDE. REPAIRED EEL RIBBON, LEFT HAND, AFT SIDE. LIGHT OP CHECKED GOOD.SDR 2007UALA03238Oven · fireGALLEY OVEN R42 CAUGHT ON FIRE. FIRE EXTINGUISED WITH HALON. REPLACED R42 GALLEY OVEN. OPS CKS OK. SUSPECT SHORT IN HEATING ELEMENT.SDR 2007UALA03226Hose · contaminatedRT OVERWING SLIDE INFLATION HOSE (FROM VESSEL TO AIRFRAME) COLLAPSED AND SPONGY. REPLACED SLIDE INFLATION HOSE DUE TO SPONGY & COLLAPSED CONDITION. HOSE ON OVERWING SLIDE INSTALLATION IS IN PROXIMITY OF HYDRAULIC SERVICING ACCESS CONNECTIONS. SPILLED HYD FSDR 2007UALA03196Probe · faultyRIGHT TANK FUEL QUANTITY GAUGE INOPERATIVE. REPLACED FUEL PROBES NR 7 AND NR 9 THRU NR 14 IN RT TANK. BITE AND OPS CHECKED OK. PANELS LEAK CHECKED OK. REBALANCED FUEL. CHECKED TANK WIRING FROM CONNECTOR TO WING TIP, FOUND NO DEFECTS. AFTER VERIFICATION FSDR 2007UALA03195Cable · disconnectedESCAPE PATH LIGHTING NEAR 14 A-B INOP. *S/D* RECONNECTED ESCAPE PATH LIGHTING AT 14 A, B.SDR 2007UALA03145Cover · missingTHE 1HJ EMERGENCY EXIT LIGHTING PLASTIC COVER MISSING. REPLACED LIGHT. TESTS OK.SDR 2007UALA03144Feeder Cable · failedEMERGENCY LIGHT STRIP AT SEATS 14ABC INOPERATIVE. REPLACED FEEDER CABLESDR 2007UALA03149Idg · faultyLEFT GEN DRIVE DISCONNECTED FOLLOWING L GEN DRIVE LIGHT ILLUMINATION. REPLACED LT IDG PER MM 24-11-01. OPS CHECK GOODSDR 2007UALA03148Battery Pack · inoperativeEMERGENCY EXIT AND FLOOR LIGHTING AT 1R ON WITH COCKPIT SWITCH IN ARMED. REPLACED M1552 & M730 BATTERY PACKS. TEST OK.SDR 2007UALA03154Sensor · out of adjustRTFL DUE TO L/E SLAT DISAGREE INDICATION & LIGHT. ADJUSTED NR 11 OUTBOARD SENSOR AND OPS CHECKED OK.SDR 2007UALA03146Light · inoperativeLEFT INBOARD FLAP EMERGENCY EXIT LIGHT INOPERATIVE. RESEATED CONNECTOR AND BATTERY.SDR 2007UALA03114Light · inoperativeSEAT 34AB EPL SEAT MOUNTED LIGHT IS INOPERATIVE. 08-31-07 REPLACED LIGHT ASSY PER MM 33-51-10 & OP CHECKED GOOD.SDR 2007UALA03113Light · inoperativeAFT GALLEY EEL LIGHT BAR INOPERATIVE. 08-31-07 REPAIRED AND REINSTALLED LIGHT BAR. OP CHECKS GOOD PER MM 33-51-10. AIRCRAFT OK FOR SERVICE.SDR 2007UALA03112Battery · dischargedEEL LIGHT INOPERATIVE ON SEAT 40AB. 08-31-07 RETERMINATED CONNECTOR AND REPLACED BATTERY PACK. OPS CK GOOD PER SWPM 20-64-17 AND MM 33-51-07. AIRCRAFT OK FOR SERVICE.SDR 2007UALA03111Feeder Cable · arcedNR 1 ENG GENERATOR FEEDER CABLE FOUND ARCING TO CLAMP, APPROX 3-16TH INCH DEEP AND 1-4 INCH WIDE. CLAMP SUPPORT BRACKED AT 9 O'CLOCK POSITION IS ONE THIRD BURNED AWAY. 09-04-07 REMOVED AND REPLACED NR 1 ENG IDG FEEDER CABLE FROM LE SPLICE TO IDG.SDR 2007UALA03110Light · looseTHE 1B EXIT PATH LIGHT ON SEATS SIDE LOOSE. 08-31-07 REPLACED EEL STRIP, CHECKS OK. AIRCRAFT OK FOR SERVICE.SDR 2007UALA03085Fire Loop · faultyRIGHT ENGINE FIRE LOOP 2. 08-31-07 FOUND BAD LOOP DETECTOR ELEMENT AT LWR AFT SECTION TS662, REPLACED PER MM 26-11-02, OPS CK NORMALSDR 2007UALA03091Aspirator · leakingASPIRATOR IS LEAKING THROUGH ORANGE SEAL. SLIDE WAS DEPLOYED IN FIELD, ASPIRATOR MAY HAVE BEEN DAMAGED. REPLACED ASPIRATOR. 08-31-07 REPLACED ASPIRATOR. ASPIRATOR DAMAGED DURING IMPROPERLY CONTROLLED DEPLOYMENT.SDR 2007UALA03044Structure · damagedFUSELAGE DAMAGED BELOW BULK CARGO DOOR. 08-31-07 ACP'D MAT'L LOSS INSP USING ULTRASONIC THICKNESS TESTER ON REPAIRED SKIN DAMAGE BELOW BULK CARGO DOOR. BLENDED DAMAGED AREA. REPAIR OK PER EVA 70500 IS FAA APPROVED VIA FAA 8100-9 FORM. AIRCRAFT OK FOR RESDR 2007UALA03045Flap System · noneLE SLAT AND TE FLAP DISAGREE EICAS ON FINAL. 08-31-07 CONFIGURED FLAPS AND CYCLED SEVERAL TIMES 0-30 UNITS, INDICATIONS NORMAL. FESU BIT TESTS DETECT NO FAULTS. GREEN TEST COMPLETE LIGHT SHOWS. UNABLE TO DUPLICATE REPORTED PROBLEM.SDR 2007UALA03032Door Frame · corrodedFWD CARGO PIT, FOUND CORROSION ON ANGLE FRAME INSIDE NEXT TO ROLLOUT STOP 3RD FROM MOST FORWARD POSITION AT STA 575. 08-31-07 REMOVED CORROSION VERIFIED MATERIAL LOSS WITHIN LIMIT. OK FOR SERVICE.SDR 2007UALA03025Light · unsecureSEAT 4HJ EMERGENCY LIGHT STRIP ON SIDE OF SEAT FALLS OFF. 08-31-07 REPLACED EEL STRIP AT 4HJ. OP CHECKD EEL SYSTEM. OK FOR SERVICE.SDR 2007UALA03015Hydraulic System · leakingRTFL UNDER AMBER ALERT DUE TO RIGHT HYDRAULIC SYSTEM QUANTITY LOSS. 08-31-07 NR 2 ENGINE EDP FAILURE AND LOSS OF RIGHT HYDRAULIC SYSTEM FLUID. REPLACED PUMP AND FILTERS. DRAINED REMAINING FLUID & FLUSHED. REPLACED FILTERS & RESERVICED FLUID. LEAK CHSDR 2007UALA02986Light · inoperativeAFT GALLEY'S EMERGENCY X-AISLE EEL LIGHT IS INOP. REPLACED EEL STRIP, OPS CHECKS GOOD.SDR 2007UALA02985Cylinder · inadequateRIGHT OVERWING SLIDE INFLATION CYLINDER IS INADEQUATE. REPLACED SLIDE INFLATION CYLINDER TO ACCOMPLISH COA 616942. ALSO FOUND COLLAPSED INFLATION HOSE DUE TO HYD FLUID CONTAMINATION. CHECKED OK FOR SERVICE.SDR 2007UALA02952Light · missingFIRST CLASS SEAT 6H IS MISSING SEAT MOUNTED EPL LIGHT STRIP. REPLACED LIGHT STRIP AT SEAT 6H PER MM 25-25-10 AND OPS CHECK IS GOOD.SDR 2007UALA02929Pin · shearedLEFT OVERWING SLIDE COMPARTMENT DOOR, FWD SLIDE PACK ALIGNMENT PIN SHEARED. FOUND DURING SLIDE CHANGE. REMOVED AND REPLACED LINE UP PIN. SUSPECT JOLT DURING FLIGHT TURBULENCE CAUSED ENOUGH MOVEMENT TO SHEAR PIN.SDR 2007UALA02928Light · wrong partSEAT 21H HAS WRONG SEAT MOUNTED EPL LIGHT STRIP INSTALLED. REPLACED LIGHT ASSY WITH CORRECT PART. OPS CK GOOD.SDR 2007UALA02927Light · inoperativeIN SEAT EMERGENCY LIGHTS ARE INOPERATIVE AT SEATS 14AB & 33AB. REMOVED AND REPLACED EEL LIGHTS IN BOTH SEAT LOCATIONS. OP CHECKS GOOD.SDR 2007UALA02940Housing · leakingCREW REPORT: FUEL BALANCE EXCEEDED 1400 LBS DURING 4 HOUR FLIGHT. TURNED ON ALL FUEL PUMPS & CHECKED FUEL TANK QTY AFTER 1 HOUR. NO LEAKS OR UNWANTED FUEL TRANSFER NOTED. CHECKED PER MM 28-11-95. LOCATED LEAK NEAR RT CTR AUX FUEL DRIP STICK NR 1 HOUSING. SDR 2007UALA02926Power Supply · faultyRIGHT SIDE BUSINESS CLASS EXIT STRIP LIGHTING ON AND OFF INTERMITTENTLY. PER FLT ATTENDANT, THE RT SIDE IN FIRST CLASS ONLY & AROUND DOOR 1R HAD THE PROBLEM. REPLACED POWER SUPPLY M1552. CHECKS GOOD.SDR 2007UALA02925Wire · exposedSOME EMERGENCY LIGHT STRIP WIRES EXPOSED. REINSTALLED EEL LIGHTS WITH EXPOSED WIRING. OP CHECKED OK FOR SERVICE.SDR 2007UALA02880Oxygen System · reads lowCREW 02 LOW READS 1300 PSI.SDR 2007UALA02879Mask · faultyCREW OXYGEN MASK PROBLEM, POSITION 2. (1=CAPT,2=FO, 3=1ST OBS, 4=2ND OBS). CREW COMMENTS: COPILOTS O2 MASK HAS LEAK IN HEAD BAND AND DOES NOT FULLY EXPAND.SDR 2007UALA02878Brake · fireON ARRIVAL HAD BRAKE FIRE ON NR 1 FWD MLG BRAKE ASSY.SDR 2007UALA02874Floorbeam · mismanufacturedCABIN FLOORBEAM AT BS 368 AND RBL 58 HAS 2 EACH MISDRILLED HOLES, ONE THROUGH UPPER CHORD AND WEB AND THE OTHER IN THE UPPER CHORD RADIUS. CUTOUT DAMAGE IN WEB AND OVERSIZED THE 2 MISDRILLED HOLES. FABRICATED 1 REPAIR ANGLE FOR THE FWD AND AFT SIDE OF THE FLSDR 2007UALA02930Panel · puncturedLEFT LEADING.EDGE SLAT NR 1 CLOSURE PANEL HAS 3 INCHES PUNCTURE, CRACKED, APPROX 20 INCHES FROM INBOARD EDGE. PERFORMED TEMPORARY REPAIR PER ENGINEERING VARIATION AUTHORITY. SLAT TO BE PERMANENTLY REPAIRED WITHIN 300 HOURS. PUNCTURE CAUSED BY GROUND EQUIPMSDR 2007UALA02871Unknown · leakingCREW REPORTED THAT CENTER HYDRAULIC SYSTEM QUANTITY WAS DECREASING EN ROUTE. SYSTEM WAS TURNED OFF AND FLIGHT CONTINUED. AMBER ALERT WAS DECLARED, FLIGHT LANDED UNEVENTFULLY AND PROCEEDED TO THE GATE UNDER IT'S OWN POWER.SDR 2007UALA02859Wire · damagedEEL FLOOR STRIP LIGHT CONNECTION DAMAGED.SDR 2007UALA02843Light · malfunctionedEMERGENCY EXIT PATHWAY LIGHTING DIM ON RIGHT SIDE, ROWS 26 THROUGH 36.SDR 2007UALA02842Light · inoperativeFWD EEL LIGHT AT SEAT 2AB AND LIGHT AT SEATS 38HJ ARE INOPERATIVE.
Back to Boeing 767-322