What was found
LEFT ENGINE FIRE LOOP 2 STATUS MESSAGE INTERMITTENTLY IN FLT. FOUND FIRE LOOP WIRES INSULATION AND BROKEN STRANDS DEFECTIVE. WIRE REPAIRED IAW MM 71-51-00. GROUND FUNCTIONAL TESTED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT ENGINE FIRE LOOP 2 STATUS MESSAGE INTERMITTENTLY IN FLT. FOUND FIRE LOOP WIRES INSULATION AND BROKEN STRANDS DEFECTIVE. WIRE REPAIRED IAW MM 71-51-00. GROUND FUNCTIONAL TESTED GOOD.