SDR UIEA2021071901592A/C Pack · faultedRIGHT PACK UNABLE TO COOL FLIGHT DECK EVEN INFLIGHT(<P><SPAN>FOUND R/H PACK TEMP CONTROLLER FAULT. SWAPPED L/H PACK TEMP CONTROLLER (PN: 625946-9 SN: 088C-3294) WITH R/H PACK TEMP CONTROLLER (PN: 625946-9 SN: 041C-3656). R/H PACK OPS NORMAL OK FOR SERVICE.</SPSDR UIEA2021071401544Contactor · faultedAPU WOULD NOT START AT BLOCK IN. EICAS MESSAGE APU FAULT BOTH TIMES.(<P>PERFORMED APU BITE PROCEDURE REF B767 FIM 49-11 FT 987. FOUND MINIFLAG 34 AND "START ABORTED" MESSAGE. PERFORMED B767 FIM 49-11 FT 989 AND FOUND NO FURTHER DEFECTS. RESET ECU AND STARTED ASDR UIEA2021070901502Heat Exchanger · faultedAFTER T/O LEFT PACK OFF & LEFT PACK TEMP EICAS MESSAGES. RAN QRH, CONTINUED FLT IN STANDBY MODE (N). FOUND CONNECTOR D2152 ON /H PACK TO BE FAULTY. REMOVED AND REPLACED LH PACK PRIMARY HEAT EXCHANGER IAW B767 AMM 21-51-02 OPS CHECK GOOD. P/N OFF: 194270-3, SDR UIEA2021070801491Warning Message · false activationL PACK OVHT WITH L PACK OFF(<P>PERFORMED BITE AND OPS CHECK ON L PACK SYSTEM, NO DEFECTS OR FAULTS NOTED, SYSTEM OPS CHECK NORMAL IAW AMM 21-51-00</P>)SDR UIEA2021070901499Apu · faultedAPU RELIABILITY COLD START ACCOMPLISHED ON FLT LEG ONT-CVG SAT -48°C FL 370 START UNSUCCESSFUL ON 3 ATTEMPTS. APU FAULT MESSAGE OCCURRED DURING APU RELIABILITY COLD START(<P>ITEM# 1 - ENG SNAPSHOT INFO NOTED BY MX. SEE NEXT DISC. ITEM FOR APU COLD SOAK FAIL..SDR UIEA2021070201467Warning Message · false indicationL PACK TEMP EICAS AT FL410(<P>ITEM TRANSFERED TO DMI #149571 IAW MEL 21-51-03-01.</P> / <P>LP 1486008: PERFORMED FIM 21-51 FAULT TREE 844, NO FAULTS NOTED. PERFORMED BIT CK PACK #1 IAW AMM 21-51-14. ALL CKS GOOD, THIS CLEARS MDDR 149571.</P>)SDR UIEA2021070601474Controller · unknownLEFT PACK TEMP INOP IN AUTO(<P>PEFORMED PACK TEMP CONTROLLER BITE PER AMM 21-51-00. OPS TEST GOOD AT THIS TIME.</P>)SDR UIEA2021062601423Apu · unknownAPU FAULT(<P>PERFORMED APU BITE PROCEDURE ON APU CONTROL UNIT. NO FAULT MESSAGES NOTED IAW AMM 49-11-00-502-002. VERIFIED APU FAULT LIGHT DID NOT ILLUMINATE, NO DEFECTS NOTED AT THIS TIME. OPS CHECKED GOOD. </P>)SDR UIEA2021062801433Fan · failedFWD EQ SUP FAN 1(<P>FOUND FWD SUPPLY FAN BREAKER TRIPPED, RESET AND REPLACED FWD EQUIP SUPPLY FAN (B10) IAW AMM 21-58-06. OPS NORMAL</P>)SDR UIEA2021061901383A/C Pack · overtempL PACK OFF/ L PACK TEMP EICAS F390, QRH LEAD TO PACK RESET AND STANDBY N POSITION, AFTER PACK RESET EICAS WENT AWAY.(<P>PLACED ON MEL 21-51-01-01 PER MDDR # 148879, CAT C, DUE: 29JUN21, MX ACTION C/W, PLACARD INSTALLED, MCC NOTIFIED. NO FAULTS ON BITE PER FIM SDR UIEA2021061401342Apu · faultedAPU FAULT 3 START ATTEMPTS(<P>PERFORMED APU ECU BITE CK PER AMM 49-61-05, NO FAULTS NOTED. ATTEMPTED APU START, SUCCESSFUL FIRST ATTEMPT. NO PRESENT OR PREVIOUS FAULTS NOTED. TRANSFERRED TO MDDR 148521 IAW DDG 25-AP-01, OPTION C, CAT N, DUE 14JUN22.</P> / <P>1SDR UIEA2021060801293None · noneL WX RADAR TILT SEEMS OFF BY APPROX 2° VERSUS R. RIGHT SIDE SEEMS CORRECT(<P>PERFORMED WEATHER RADAR SYSTEM TEST IAW AMM 34-43-00. NO DEFECTS NOTED AT THIS TIME. SYSTEM TEST GOOD.</P>)SDR UIEA2021052401175Door Sill · gougedMAIN CARGO DOOR SILL GOUGED AT BS 522. DOT 99/035(<P>UPON EVALUATION OF DAMAGE AT MAIN CARGO LWR SILL STA. 522 FOUND OUT OF LIMITS IAW B767 SRM 53-00-15-1A-1. REPAIRED LWR SILL STA 522 IAW FAS EA 21051 REV. IR</P>)SDR UIEA2021052601178Seat Track · corrodedFLIGHT DECK CAPT SEAT R/H FWD SEAT TRACK CORRODED(<P>REMOVED AND REPLACED SEAT TRACK ON FLIGHT DECK CAPT SEAT R/H FWD IAW B767 SRM 51-40-02 AND B767 AMM 25-11-01-822-095-001 PN 1A098-0103 PO# 1499B-00026</P>)SDR UIEA2021052601179Seat Track · corrodedFLIGHT DECK F/O SEAT L/H FWD SEAT TRACK CORRODED FWD R/H SIDE(<P>REMOVED AND REPLACED FO FWD IB SEAT TRACK PN 1A098-104 PO 1499B-00038 IAW B767 AMM 25-11-01-822-095-001.</P>)SDR UIEA2021052601201Bear Strap · corrodedC-1 DOOR CUT-OUT , UPPER FWD CORNER HAS EXFOLIATING CORROSION ON INNER SKIN.(<P>REMOVED CORROSION FROM C-1 DOOR CUT-OUT UPR BEAR STRAP FWD CORNER AND FOUND OUT OF LIMITS IAW B767 SRM 53-00-01-1A-1. REPAIRED UPR BEAR STRAP FWD CORNER IAW FAS EA 21050 REV. IR</SDR UIEA2021052701204Skin · corrodedBUBBLE PAINT EXTERIOR SKIN STA. 1310 STR. 34L SECTION 48. DOT 88-003(<P>UPON EVALUATION FUSELAGE SKIN AT STA. 1310 STR. 34L FOUND TO BE EXFOLIATED 100% MATERIAL LOSS. CUTOUT DAMAGE AND APPLIED A FILLER/DOUBLER REPAIR IAW B767 SRM 53-00-01-2R-1, 53-00-01, 51-10SDR UIEA2021060101213Floorbeam · corrodedAFT CARGO COMPARTMENT FLOOR PANEL ATTACH ANGLE IS CORRODED AT BS 1345 RBL 55. DOT 014(<P>UPON EVAL. FLOOR PNL ATTACH ANGLE AT STA. 1345 RBL 55 HAS 100% MAT. LOSS AND OUT OF LIMITS IAW B767 SRM 53-00-15-1A-1. REMOVED AND REPLACED ANGLE IAW BOEING DWG. 146T5001 SDR UIEA2021060101221Shear Web · corrodedAFT CARGO COMPARTMENT FLOOR SHEAR WEB HAS AREA OF CORROSION AT BONDING JUMPER ATTACH AREA BS 1330 RBL 40. DOT 016(<P>UPON EVAL. OF FLOOR SHEAR WEB STA. 1330 RBL 40. FOUND 100% OUT OF LIMITS IAW B767 SRM 51-70-13-0G-0. REMOVED AND REPLACED SHEAR WB IAW B767 SRSDR UIEA2021060101231Skin · delaminatedRH WING #8 SLAT UPPER SURFACE OF TE WEDGE IS DELAMINATED AT IB UPPER CORNER OF SLAT. DOT 005(<P>REPAIRED UPR SURFACE OF #8 SLAT TE WEDGE IB UPR CORNER IAW B767 SRM 57-43-02-01-01, 51-70-10 REP.4</P>)SDR UIEA2021060201262Splice Angle · crackedAREA AFT OF BULK CARGO COMPT STA. 1577 RH OB SIDE WL 200 MAIN DECK FLOOR SUPT OB SPLICE ANGLE CRACKED 1IN IN LENGTH ON BOTTOM. DOT 127-013(<P>REMOVED CRACKED SPLICE ANGLE AT AFT OF BULK CARGO COMPT STA 1577 RH OB SIDE WL 200 MAIN DECK FLOOR SUPT OB SIDE IAW B7SDR UIEA2021050301053Warning Message · false activationFWD EQPT OVHT UPON LANDING.(<P>TRANSFERRED TO DMI # 146288 MEL 21-58-03-02-01 CAT C DEFERRAL DUE DATE 12MAY21.</P><P>REF MDDR 146288 REF LOG PG # 1465089 ITEM M9 . TS PER FIM TASK 21-58 FT 991, NO FAULTS NOTED, UNABLE TO DUPLICATE FAULT. PERFORMED OPS CHECK OFSDR UIEA2021050201051Warning Message · false indicationFWD EQUIP OVHT UPON LANDING(<P>FWD EQUIP SUPPLY FAN TRANSFERRED TO MDDR 146288 IAW MEL 21-58-03-02-01.</P><P>2MAY2021 - 1465089 ITEM #10 - TS PER FIM TASK 21-58 FT 991 NO FAULTS NOTED UNABLE TO DUPLICATE FAULT. PERF OPS CHECK OF FWD/AFT EQUIPMENT COOLING SYSTESDR 2021F00054Blade · damaged71 02 59 01 (VIBRATION DURING DESCENT ENGINE 1). DURING BOROSCOPE INSPECTION 31 BALDES DAMAGED IN HPC 4TH STAGE; 16 BLADES DAMAGED IN HPC 5TH STAGE, BLADES DAMAGED IN HPC 6TH STAGE, BLADES DEMAGED IN HPC 7TH STAGE, BLADES DAMAGED IN HPC 13TH STAGE, NGV TE OUTESDR UIEA2021040900864Connector · dirtyEICAS STATUS MSG. "FWD EQ SUP FAN 1". CB'S (2) COLLARED SYSTEM SWITCHED TO STBY DISPATCH JT @ 0421Z. LP 1066388: T/S PER FIM 21-58 FT 991 AND 21-58 FT 983. B767 AMM 21-58-10. CHECKED AIR INLET AIR GRILL, CLEANED CONNECTOR D446 AND OPS TESTED FWD EQUIPMENT COOLSDR UIEA2021040600839Warning Message · false activationAT FL 400 L PACK TEMP EICAS MESSAGE FOLLOWED BY L PACK OFF. ACCOMPLISHED QRH AND RESET PACK. PACK LIGHTS EXTINGUISHED AND CONTINUED IN STBY.(<P>PERFORMED BITE TEST ON L PACK TEMP CONTROLLER BOX 1. NO FAULTS NOTED AND OPS CHECK OF L PACK GOOD IAW B767 AMM 21-5SDR UIEA2021040200784Warning Message · false activationAT FL 400 L PACK TEMP EICAS MESSAGE FOLLOWED BY L PACK OFF. ACCOMPLISHED QRH AND RESET PCK. PACK LIGHTS EXTINGUISHED AND CONTINUED IN STBY N.(<P>PERFORMED BITE TEST ON L PACK TEMP CONTROLLER BOX, NO FAULTS NOTED. OPS CHECK OF L PACK GOOD. IAW B767 AMM 21-51-14SDR UIEA2021032700725Warning Message · false activationL PACK INOP AND L PACK TEMP EICAS DISPLAYED ENROUTE AT CRUISE FL390, STANDBY "N" SELECTED PER QRH, PACK RESET SWITCH PUSHED AND EICAS REMAINED CLEARED WITH STANDBY *N* SELECTED.(<P>PERFORMED FIM TASK 21-51 FT 844. OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2021032400705Radar · malfunctionedR WXR RADAR FAIL IN FLIGHT(<P>ACCOMPLISHED WXR OPERATIONAL TEST IAW ATLAS AMM TASK 34-43-00-715-026-002. OPS CHECK GOOD. NO FURTHER MX ACTION REQ.</P>)SDR UIEA2021031600600Liner · crackedENGINE # 2 S/N 702954 COMBUSTION CHAMBER OUTER LINER BETWEEN 7 TO 8 O'CLOCK POSITION HAS A TWO PANEL CRACK BETWEEN PANEL # 1 AND PANEL # 2. REQUIRES RE-INSPECTION EVERY 200 CYCLES PER W/C # A-72-307-C1-2 TABLE 3(<P>TRANSFERRED ITEM TO MCI A-001</P>)SDR UIEA2021030900506Idg · malfunctioned"R GEN DRIVE" EICAS MANUALLY DISCONNECTED RIGHT GENERATOR DRIVE.(<P>PLACED ON MDDR 143574 IAW MEL 24-00-01-01, CAT B.</P><P>CVG MX, 10MAR21 LP 1345596, ITEM M2: REMOVED AND REPLACED R/H ENG IDG. REF B767 AMM 24-11-01. OPS CHECK IS SATISFACTORY. THIS CLEARS DMISDR UIEA2021030900507Filter Element · warning messageON CLIMB OUT RECEIVED "L ENG FUEL FILT" EICAS MSG. COMPLIED W/QRH PROC. ALL ENG. INDICATIONS NORMAL. ASSC. STATUS MSG. RECEIVED.(<P>REMOVED AND REPLACED L ENGINE FUEL FILTER ELEMENTS IAW FIM 73-11 FT 803 AND 73-11-02, NO FAULTS NOTED. LEAK CHECK GOOD.</P>)SDR UIEA2021030800488Filter · warning messageON CLIMB OUT RECEIVED "R ENG FUEL FILT" EICAS MSG. COMPLIED W/ QRH. ALL ENGINE INDICATIONS NORMAL.(<P>REMOVED AND REPLACED RH ENG FUEL FILTER IAW AMM 73-11-02. PERFORMED IDLE RUN OF RH ENG IAW AMM 71-00-00. NO MESSAGES NOTED AT THIS TIME. NO LEAKS NOTED OPS CHSDR UIEA2021030200463Ecu · inoperativeAPU PNUEMATICS INOP(<P>TRANSFER TO MDDR #143232, CAT C, PER DDG 49-11-01-01. DUE 12 MAR21. PLACARDS INSTALLED, MX ACTION COMPLIED WITH.</P><P>LP 1254846: T/S PER FIM 49-11 FT A21 FIG 130. NO MINI FLAG. REMOVED AND REPLACED ECU. OPS CHECK GOOD IAW AMM 49-61-05.SDR UIEA2021030200440Sensor · faultyAPU INOP TRANSFERRED TO MDDR 143164 IAW MEL 49-11-01A, CAT C. PERFORMED APU BITE. IAW FIMM 49-11, FAULT 16, P2 SENSOR. REMOVED AND REPLACED P2 SENSOR. IAW AMM 49-61-04. DURING T/S FOUND APU OIL OVER SERVICED. SERVICED APU OIL TO PROPER LEVEL. IAW AMM 12-13SDR UIEA2021022500419Seal · not reportedPER MCC REQUESTED REPLACE LT DUCT INST BODY CROSSOVER AIR SUPPLY SYS(DUCT ONLY) SEALS PN 460-500 ON ASSY PN 14A640-101(<P>REMOVED AND REPLACED DUCT SEAL ON ASSY PN 14A640-101 ON LT DUCT BODY CROSSOVER AIR SUPPLY SYSTEM. IAW AMM 21-51-02 , SUB TASK 21-51-02-434SDR UIEA2021022400417Heat Exchanger · failedAFTER TAKE OFF, L PACK TEMP FOLLOWED BY L PACK OFF EICAS W/ ASSOCIATED OVHD PANEL LIGHTS IN AUTO (T/S IAW WITH FIM 21-51-848. L PACK TEMP CONTROLLER DID NOT PICK UP FAULT. LP 1480531 ITEM 4 -DURING SYS TEST/INSPECTION IAW 21-51-00 TEMP CONTROL VALVE INDICATISDR UIEA2021022200398Igniter · failedAPU NO LIGHT OFF. REMOVED AND REPLACED APU IGNITER PLUG IAW AMM 49-41-02. OPS CHECK GOOD AT THIS TIME.SDR UIEA2021021200292Packing · leakingNUMBER 2 ENG LEAK AT HPC SIGNAL PRESSURE TUBE LOC N. REMOVED AND REPLACED PACKING PER ENGINEERING ORDER NR 1936A088 AT HPC SIGNAL PRESSURE TUBE LOC N.SDR UIEA2021021200293Packing · leakingNUMBER 2 ENG LEAK AT PRVC ACTUATOR PRESSURE TUBE LOC K. REMOVED AND REPLACED PACKING PER ENGINEERING ORDER NR 1936A088 AT PRVC ACTUATOR PRESSURE TUBE LOCK.SDR UIEA2021021200294Packing · leakingNUMBER 1 ENGINE LEAK AT HPC SIGNAL PRESSURE TUBE LOC N. REMOVED AND REPLACED PACKING AS PER EO NR 1936A088. NO LEAKS NOTED.SDR UIEA2021021200295Packing · leakingNUMBER 1 ENG LEAK AT PRVC ACTUATOR PRESSURE TUBE LOC K. REMOVED AND REPLACED PACKING AT LOCK AS PER EO NR 1936A088. NO LEAKS NOTED.SDR UIEA2021021200296Packing · leakingNUMBER 1 ENG PRVC SENSE LINE LOC C FITTING HAS A LEAK. REMOVED AND REPLACED PACKING AT LOC E AS PER EO NR 1936A088. NO LEAKS NOTED.SDR UIEA2021021200297Depressor · damagedMAIN CARGO DECK SEAL DEPRESSOR DAMAGED AFT MIDDLE. FOUND TO BE WITHIN LIMITS PER SRM 53-06-15-1A-1. REMOVED AND REPLACED DAMAGED SEAL DEPRESSOR AT M/D CARGO DOOR CUT OUT DRILLED DEBURRED; INSTALLED NEW SEAL DEPRESSOR AND PAINTED PER B767-300; SRM 51-40-02-0GSDR UIEA2021021200298Servo · inoperativeLT AUTO PILOT INOPERATIVE. AUTO PILOT SYSTEMS, ONE INOPERATIVE. NOTIFY DISPATCH. A/C CAT III REST. PERFORMED FAULT TREE 22-03 MCDP G/T 08 SERVO ELEV. FAIL L ELEV. AP SERVO M271; SERVO ELEV LT M271 ON ORDER. REMOVED AND REPLACED ELEV & LT AUTO PILOT SERVO SDR UIEA2021021200301Irs · failedLEFT IRS FAIL ON TAKE - OFF. PERFORMED L IRS NNC. REPLACED TROLH M159 AND OPS TEST OK AMM 34-21-01.SDR UIEA2021021200302Autobrake Sys · malfunctionedAUTO BRAKES INOPERATIVE. PERFORMED AUTO BRAKE INOPERATIVE NNC. AFTER ACCOMPLISHED CORRECTIVE ACTION NR-15 "LEFT IRS FAIL ON T/O" PERFORMED AUTO BRAKE & SYSTEM TEST OK PER AMM 32-42-00/705.SDR UIEA2021021200303Seal Depressor · damagedMAIN DECK CARGO DOOR. LOWER LEFT SIDE CORNER DEPRESSOR SEAL DAMAGED. REMOVED DAMAGED LOWER CORNER SEAL DEPRESSOR. DRILLED DEBURRED & INSTALLED NEW SEAL DEPRESSOR AT M/D DOOR CUTOUT PER B767-300 SRM 51-40-02-0G-0 AND AMM 20-11-00-910-802.SDR UIEA2021021200304Seal · brokenCOCKPIT AVSAX CONTAINMENT BAG VACUUM SEAL IS BROKEN PN AS-002-1. REMOVED AND REPLACED AVSAX CONTAINMENT BAG AS REQUIRED PER AMM 25-13-00 CK'D OK.SDR UIEA2021021200305Clamp · brokenONE EA BROKEN CLAMP AT NR 1 ENG I/B SIDE AFT OF HEAT EXCHANGER (PNEUMATIC LINE FOR HPSOV ) (REMOVED AND REPLACED CLAMP AT NR 1 ENG I/B PNEUMATIC LINE FOR HPSOV AS PER B767-300 AMM 70-50-01.)
Back to Boeing 767-328