What was found
APU WOULD NOT START AT BLOCK IN. EICAS MESSAGE APU FAULT BOTH TIMES.(<P>PERFORMED APU BITE PROCEDURE REF B767 FIM 49-11 FT 987. FOUND MINIFLAG 34 AND "START ABORTED" MESSAGE. PERFORMED B767 FIM 49-11 FT 989 AND FOUND NO FURTHER DEFECTS. RESET ECU AND STARTED APU ON FIRST ATTEMPT SATISFACTORY. ALL APU PARAMETERS NORMAL. OK TO CONTINUE.</P> / <P>LP 1393836, ITEM M5: APU INOP PER ENGINEERING'S REQUEST. TRANSFERRED TO MDDR # 150135 PER MEL 49-11-01A, CAT "C". DUE: 23JUL21. PLACARDS INSTALLED. MCC ADVISED. DISPATCH: JT 21:22Z.</P> / <P>LOGPAGE 1343113 ITEM 5 AND LOGPAGE 1343114 ITEM 8: REMOVED AND REPLACED APU OIL TEMP SWITCH IAW AMM 49-27-14. LEAK CHECK GOOD. SEE LP 1343113 ITEM M7 FOR FURTHER WORK. REMOVED AND REPLACED APU CRANK CONTACTOR IAW AMM 49-41-05. OPS CHECK GOOD.