Boeing 767-332
Service difficulty reports · 11,959
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HALA2011051300192Processing Unit · faultedETOPS SIGNIFICANT SYS - EICAS MESSAGE FUEL QTY CHANNEL DISPLAYED. DISPLAY RETURNED WITHIN 60 SECONDS OF FUEL QTY TEST. BITE CHECK FQIS, FOUND 3 PRELEGS FAULTS, R & R FUEL QUANTITY PROCESSOR UNIT, IAW MM 28-41-08, OPS, BITE, QTY CHECKED OK.SDR DALA1135981601Wedge · delaminatedLT WING NR 3 SLAT T/E WEDGE FOUND DELAMINATED AT O/B AREA. METAL HOT BOND REPAIR PERFORMED AT DELAMINATION AREA AS PER SRM 57-43-02 REPAIR 1 FIG 201 AND SRM 51-70-10 REPAIR 4 FIG 202.SDR DALA1133590196Light · inoperativeEMERGENCY LIGHTS AT SEATS 1AB ARE INOPERATIVE. MAINTENANCE SEATS. SYSTEM OPERATION IS NORMAL.SDR DALA1133580196Connector · looseEMERGENCY LIGHTS AT SEAT 23A ARE INOPERATIVE. MAINTENANCE RESECURED THE CONNECTOR. SYSTEM OPERATION IS NORMAL.SDR HALA2011051200190Light · malfunctionedETOPS SIGNIFICANT SYS - OFFSET INDICATOR LIGHT ON F/O'S CDU DOES NOT COME ON WHEN COURSE OFFSET SELECTED. T/S IAW FIM 34-61-00 FIG 111. NO FAULT NOTED. UNABLE TO DUPLICATE ON GROUND. NO 30 DAY HISTORY, OK FOR SERVICE.SDR HALA2011051200189Cabin Pressure · malfunctionedETOPS SIGNIFICANT SYS - BTB -CABIN ALTITUDE INOPERATIVE AUTO EICAS MESSAGE. CABIN DESCENDED AT 2000 FPM. TURNED BOTH PACKS OFF WHEN DIFFERENTIAL REACHED 2 PSI. T/S IAW FIM 21-31-00, DID BITE TEST OF BOTH CABIN PRESSURE CONTOLLERS. NO FAULTS. CHECKED OUTFLSDR DALA1133600183Controller · malfunctionedAT CRUISE ALTITUDE CREW REPORTED LT FWD WINDOW HEAT EICAS LIGHT ON OVERHEAD PANEL. SMALL PUFF OF SMOKE OBSERVED NEAR CONNECTION. FOLLOWED QRH, TURNED OFF WINDOW HEAT, SMOKE QUICWINDOW AND RIGHT SIDE WINDOW CONTROLLER AND L1 WINDSHIELD OPERATION IS NORMAL.SDR DALA1404530191Structure · damagedLOWER WING SKIN TENSION BOLT HOLE. REPAIRED IAW AA 5700-01029.SDR HALA2011051000191Warning Light · false activationETOPS SIGNIFICANT SYS -RT DUCT LEAK LIGHT ON OVERHEAD PANEL WITH EICAS RT BLEED DUCT LEAK FLICKERED ON/OFF NUMEROUS TIMES DURING FLIGHT. FIM 26-18-00 C/W SYS & OPS CK, NO DEFECTS NOTED.SDR DALA1132840180Light · disconnectedEMERGENCY LIGHTS AT 36AB ARE INOPERATIVE. MAINTENANCE RECONNECTED THE LIGHTS ASSEMBLY. SYSTEM OPERATION IS NORMAL.SDR DALA1135811403Frame · crackedM/D STA 903 RBL 92 FRAME INNER CHORD FOUND CRACK. THE FRAME INNER CHORD REPAIRED AS PER ER/A 489746-14AD.SDR DALA1135801403Frame · crackedM/D STA 903 LBL 92 FRAME INNER CHORD FOUND CRACK AND THAT FRAME INNER CHORD REPAIRED PER ER/A 489750-14AD.SDR DALA1133041607Battery · dischargedEMERGENCY ESCAPE SQUIB FOR LEFT AND RIGHT WILL NOT TEST. MAINTENANCE FOUND BATTERY M961 LOW AND REPLACED THE BATTERY AND CHARGER. SYSTEM OPERATION IS NORMAL.SDR DALA1132810174Wire · brokenEMERGENCY PATH LIGHTS AT SEAT 27B ARE INOPERATIVE. MAINTENANCE FOUND WIRE BROKEN AT CONNECTED AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1132830174Socket · defectiveEMERGENCY PATH LIGHTS AT SEAT 25 FG ARE INOPERATIVE. MAINTENANCE REPLACED THE SOCKET. SYSTEM OPERATION IS NORMAL.SDR DALA1131731608Frame · crackedFS 903 RT FRAME INNER CHORD WAS CRACKED BETWEEN STR 20R AND 21R AND WAS REPAIRED PER ERA 488821-14AD REV ORG.SDR DALA1136591403Skin · dentedADF 004 - DUE BIRD STRIKE FOUND DENT ON LEFT AREA OF FX. FORWARD PITOT TUBE INSP AREA PER SRM 51-10-03 AS PER ER/A 491097-14.SDR DALA1131451701Fitting · crackedFS 955 LT REAR SPAR BULKHEAD FITTING FAIL SAFE STRAP AND T FITTING WERE CRACKED AT 03:00 AND 07:00 POS APPROX 1/8 INCH AND THRU THICKNESS. REPAIRED PER ERA 489727-14AD.SDR DALA1131431701Fairing · delaminatedLT INBD MAIN FLAP L/E FAIRING FOUND DELAMINATED AND REPAIRED PER SRM 57-53-01 REPAIR 1 AND SRM 51-70-05 FIG 5.SDR DALA1131421701Wedge · debondedNR 7 SLAT WEDGE DISBONDED AND REPAIRED PER SRM 57-43-02 REPAIR 1 FIG 201 AND SRM 51-70-10 REPAIR 4 FIG 202.SDR DALA1131411701Frame · crackedFS 903 FRAME BETWEEN STR 20L AND 21L INNER CHORD CRACKED AND REPAIRED PER ERA 489732-14AD REV ORG.SDR HALA2011050400181Blades · damagedETOPS SIGNIFICANT SYS - ON OVERNIGHT NR 1 ENG FOUND NR 4, 5, 6, 7, 8, 9 AND 10 BLADES INBEDDED IN ACOUSTIC. REMOVED BLADES NR 4, 5, 6, 7, 8, 9 AND 10 IAW AMM 72-31-02. REPAIRED ACOUSTIC LINER IAW M105 594140. REINSTALLED FAN BLADES NBR 4,5,6,7,8,9 AND 10 IAW SDR HALA2011050400180Shroud · damagedETOPS SIGNIFICANT SYS - FAN CASE SHROUD DAMAGED AT 7 O`CLOCK POSITION NR 1 ENG. REPAIRED FAN CASE SHROUD IAW AMM 72-34-01 AND HAL M105 594140. PERFORMED IDLE VIBRATION RUN M105 594140. OPS CK GOOD.SDR DALA1132871606Power Supply · inoperativeEMERGENCY LIGHTS BETWEEN ROWS 6AB AND 19AB FAILS TO ILLUMINATE. MAINTENANCE REPLACED THE POWER SUPPLY. SYSTEM OPERATION IS NORMAL.SDR DALA1131380188Light · missingON DRC FOUND EMERGENCY LIGHT AT SEAT 26F MISSING. MAINTENANCE REPLACED THE EMERGENCY LIGHT ASSEMBLY. SYSTEM OPERATION IS NORMAL.SDR HALA2011050100177Irs · faultedETOPS SIGNIFICANT SYS - LEFT IRS FAULT ILLUMINATED AFTER LANDING. ACCOMPLISHED FIM 34-21-00/101, TESTS 1-13 SYS CHECKS. OK. LMP DOWNGRADED TO LAND 2.SDR DALA1130071201Skin · debondedRIGHT I/B AFT FLAP LWR SURFACE IS DISBONDED AND REPAIRED PER SRM 51-70-10 REPAIR 2 FIG 203 AND SRM 57-53-01 REPAIR 1 FIG 201.SDR DALA1129711201Skate Angle · crackedNR 1 PYLON I/B AFT SKATE ANGLE AFT END CRACKED & REPAIRED PER ERA 489730-14 REV ORG.SDR DALA1129111201Wedge · deformedNR 9 SLAT WEDGE AREA OTBD END FOUND DEFORMED AND METAL HOT BOND REPAIR PERFORMED IAW SRM 57-43-02, REPAIR 1, FIG 201 AND SRM 51-70-10, REPAIR 4, FIG 202.SDR DALA1129101201Failsafe · crackedRT FS 955 B/H FAIL SAFE STRAP FASTENER HOLE CRACKED AND REPAIRED IAW ERA 489723-14AD, REV ORG.SDR DALA1129121201Wedge · debondedNR 6 SLAT INBD UPPER T/E WEDGE FOUND DISBONDED AND METAL HOT BOND REPAIR PERFORMED IAW SRM 57-43-02, REPAIR 1, FIG 201 AND SRM 51-70-10, REPAIR 4, FIG 201.SDR HALA2011042700171Antenna · bindingETOPS SIGNIFICANT SYS - DUE TO WX RADAR FAIL, ANT FAULT. WX RADAR ANT FOUND JAMMED ON 90. WX RADAR ANT REPLACED & TESTED IAW AMM 34-43-05-714-020-002.SDR DALA1128491708Oven · contaminatedCREW SMELLED BURNING PAPER IN THE AFT GALLEY AND PULLED THE GALLEY CIRCUIT BREAKER AND THE ODOR WENT AWAY. FOUND PAPER IN AFT GALLEY OVENS AND CLEANED. AS A PRECAUTION RAN ALL OVENS IN AFT GALLEY. SYSTEM OPERATION IS NORMAL.SDR DALA1128561606Charger · inoperativeEMERGENCY LIGHTS AT ROWS 6AB THROUGH 20AB ARE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY CHARGER AT SEAT 6AB. SYSTEM OPERATION IS NORMAL.SDR DALA1128550185Light · damagedEMERGENCY PATH LIGHT ON SEAT 34AB FOUND DAMAGED, MAINTENANCE REPLACED THE LIGHT ASSEMBLY. SYSTEM OPERATION IS NORMAL.SDR ANZY20110503Skin · corrodedWING CTR SECTION, UPPER SKIN PANEL, U-17C AND LBL 92 UPPER WING SKIN AND SPLICE: SKIN CORRODED BEYOND SRM LIMITS. DURING FINAL CLOSE UP OF AIR RETURN GRILLS IN THE OVER WING AREA, A FOD INSP WAS CARRIED OUT WITH MIRROR, PRIOR TO INSTALLING THE PANEL. HEAVY CSDR HALA2011041900163A/C Pack · malfunctionedETOPS SIGNIFICANT SYS - RT PACK INOP LIGHT ILLUM, EICAS MESSAGE RT PACK TEMP DISPLAYED NORMAL AFT STBY SELECTED. T/S IAW FIM 21-51-00/101, FIG 103. DID PACK TEMP CONTROLLER BITE CHECK. NO FAULTS. RAN PACKS FOR APPROX 30 MINS. PACK OPEN AND TEMP NORMAL. RSDR DALA1127241603Battery Pack · inoperativeNO SEAT EMERGENCY LIGHTS FROM ROWS 32-41 ON THE RT SIDE ARE INOPERATIVE. MX REPLACED THE POWER SUPPLY AND BATTERY PACK FOR THE ZONE. SYS OPS IS NORMAL.SDR DALA1127231603Wire Harness · inoperativeEMERGENCY ESCAPE PATH MARKERS ARE INOPERATIVE AT SEAT 37F. MX REPLACED THE WIRING HARNESS FOR SEAT 37F. SYS OPS IS NORMAL.SDR DALA1127250193Light · inoperativeWHITE EMERGENCY LIGHT AT 25FG IS INOPERATIVE. MX REPLACED THE BULBS AND SOCKET ASSY BUT NO HELP. FWD IAW MEL 33-51-03A.SDR HALA2011041600157Transmitter · out of adjustETOPS SIGNIFICANT SYS. ON TAXI CHECK SELECTING FLAP 5, NOTICED A SIGNIFICANT DIFFERENCE IN AILERON DROOP FROM LT TO RT. BITE FSEU & PSEU NO FAULTS NOTED. NO EICAS MSGS. VERIFIED INBD AILERON SPLIT. CHECKED INBD AILERON DROOP IAW AMM 27-11-06, CK OK, CK INSDR DALA1127351401Structure · corrodedCHORD IN NOSE WHEEL WELL IN AFT CORNER BEHIND NOSE STEERING CHECK VALVE CORROSION C/W IAW ERA 491891-14 ORG.SDR DALA1126920187Connector · looseEMERGENCY PATH LIGHTS AT SEAT 25F ARE INOPERATIVE. MAINTENANCE FOUND THE CONNECTOR LOOSE AND RE-SECURED.SDR DALA1126031613Light · shortedEMERGENCY LIGHTS SEAT 1GF TO 3GF ARE INOPERATIVE. MAINTENANCE REPLACED THE SHORTED BULB AT 2FG AND THE FUSE ON THE BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA1127081609Skin · delaminatedLT WING INBD MAIN FLAP OTBD L/E NOSE FAIRING FOUND DELAMINATED. COMPOSITE PREPREG LAY UP HOT BOND REPAIR CARRIED OUT IAW SRM 57-53-01, REPAIR 1 AND SRM 51-70-05, FIG 5.SDR DALA1127071609Skin · delaminatedRT WING INBD MAIN FLAP OTBD L/E NOSE FAIRING FOUND DELAMINATED. COMPOSITE PREPREG LAY UP HOT BOND REPAIR CARRIED OUT IAW SRM 57-53-01, REPAIR 1 AND SRM 51-70-05, FIG 5.SDR DALA1140780138Stringer · damagedFUSELAGE STRINGER LBL & RBL 85.9, FS 966. REPAIRED IAW ERA 481423-14.SDR DALA1131401701Frame · crackedM/D STA 903 FRAME BTN STR 20R AND 21R INNER CHORD CRACKED AND REPAIRED AS PER ERA 489733-14AD REV ORIG.SDR DALA1127061609Skin · damagedDURING WALK CHECK FOUND 0.25" HOLE ON LT STABLIZER BOTTOM SURFACE 1' OF AUX SPAR STA 191. METAL HOT BOND REPAIR PERFORMED AT HOLE AREA IAW SRM 55-10-01, REPAIR 1 FIG 201 AND SRM 51-70-10, REPAIR 4, FIG 201.SDR DALA1125330130Light · inoperativeDURING OP 2525 FOUND EMERGENCY LIGHT INOPERATIVE FROM ROWS 1-12 RIGHT SIDE AND 13-21 LEFT SIDE. MAINTENANCE REPLACED M9008 AND M9009 PER AMM. SYSTEM OPERATION IS NORMAL.
Back to Boeing 767-332