SDR IPXA09656497Skin · dentedINSPECTION TYPE:7C SURVEY SEQUENCE 309-F1-02 FX BS 443 TO BS 460 & STR 22R - 25R EXISTING REPAIR DOUBLER CLOSE TO FWD CARGO DOOR CUTOUT. DENT REVEALED AND NO CUTOUT FOUND. SURVEY SEQUENCE 309-F1-02 FUSELAGE BETWEEN BS 443 TO BS 460 AND STR 22R - 25R SKIN REPSDR IPXA09656476Attach Fitting · crackedINSPECTION TYPE:7C MAIN E/E COMPT STA 246 RBL 10 MAIN DECK FLOOR SUPPORT BEAM ATT CLIP AT FRONT SURFACE FOUND CRACK. MAIN E/E COMPT STA 246 RBL 10 MAIN DECK FLOOR SUPPORT BEAM ATT CLIP AT FRONT SURFACE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-SDR IPXA09656474Attach Fitting · crackedINSPECTION TYPE:7C RT WING - L/E LES 675 FIXED FAIRING UPPER SUPPORT WEB AFT FRONT SPAR CLIP FOUND CRACKED. RT WING - L/E LES 675 FIXED FAIRING UPPER SUPPORT WEB AFT FRONT SPAR CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656473Attach Fitting · crackedINSPECTION TYPE:7C RT WING L/E LES 546 FIXED FAIRING UPPER SUPPORT WEB AFT FRONT SPAR CLIP FOUND CRACKED. RT WING L/E LES 546 FIXED FAIRING UPPER SUPPORT WEB AFT FRONT SPAR CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656437Attach Fitting · crackedINSPECTION TYPE:C MAIN E/E COMPT STA 246 LBL 50 MAIN DECK FLOOR SUPPORT BEAM ATT CLIP AT REAR SURFACE FOUND CRACKED (0.75 INCH LENGTH). MAIN E/E COMPT STA 246 LBL 50 MAIN DECK FLOOR SUPPORT BEAM ATT CLIP AT REAR SURFACE REPLACED AS PER SRM 51-10-02 AND INSTALSDR IPXA09656436Attach Angle · crackedINSPECTION TYPE:C MAIN E/E COMPT STA 246 LBL 25 MAIN DECK FLOOR SUPPORT BEAM ATT ANGLE AT FRONT SURFACE FOUND CRACK (CRACK 0.5 INCH LENGTH. MAIN E/E COMPT STA 246 LBL 25 MAIN DECK FLOOR SUPPORT BEAM ATT ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SDR IPXA09656427Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1480 TO STA 1598 LBL 11 TO RBL 11. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09656426Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1197+22 TO STA 1207 LBL 11 TO RBL 11. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09656425Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1207 TO STA 1344 LBL 11 TO RBL 11. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09656424Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 654+22 TO STA 690 LBL 11 TO RBL 11. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09656423Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1344 TO STA 1480, LBL 77 TO LBL 88. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09656422Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGE AT STA 1430 TO STA 1540, LBL 55 TO LBL 77. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09656421Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 412 TO STA 550, LBL 77 TO LBL 88. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09656414Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 412 TO STA 540, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656413Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 412 TO STA 540, LBL 55 TO LBL 77. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656412Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL FOUND DAMAGE AT STA 540 TO STA 654+22 LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-11-01.SDR IPXA09656411Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 412 TO STA 540, RBL 55 TO RBL 77. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656410Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 731 TO STA 833, RBL 33 TO RBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656408Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 1197+132 TO STA 1207 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656407Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 1197+22 TO STA 1207, RBL 55 TO RBL 77. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656406Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 550 TO STA 654+22 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656405Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 654+22 TO STA 690, LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656403Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 731 TO STA 833, LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656402Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 930 TO STA 975, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656401Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 833 TO STA 930 LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656400Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 975 TO STA 1114 LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656377Fitting · crackedINSPECTION TYPE:6C AFT CARGO STA 1087 LBL 25 BELOW FLOOR SUPPORT CLIP FOUND CRACK. AFT CARGO COMPT BS 1087 LBL 25 BELOW FLOOR SUPPORT ATT ANGLE REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02.SDR IPXA09656376Fitting · crackedINSPECTION TYPE:6C AFT CARGO STA 1087 RBL 25 BELOW FLOOR SUPPORT CLIP FOUND CRACK. AFT CARGO COMPT BS 1087 RBL 25 BELOW FLOOR SUPPORT ATT ANGLE REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02.SDR IPXA09656475Attach Fitting · crackedINSPECTION TYPE:7C LT WING L/E LES 675 FIXED FAIRING UPPER SUPPORT WEB AT FRONT SPAR CLIP FOUND CRACKED. LT WING L/E LES 675 FIXED FAIRING UPPER SUPPORT WEB AT FRONT SPAR CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656439Stiffener · crackedINSPECTION TYPE:C CENTER WING TANK FRONT SPAR VERTICAL STIFFENER CRACKED AT BS 786 RBL 10, JUST BELOW CABIN FLOOR (CRACK 3.25 INCH LENGTH). CTR WING TANK FRONT SPAR VERT STIFFENER AT BS 786 RBL 10 AREA REPAIRED AS PER HX RS R57-10-36354 REV A & UPS EO B767-57SDR IPXA09656438Hinge Fitting · crackedINSPECTION TYPE:C RT WING I/B MAIN FLAP I/B AFT FLAP HINGE ARM FTG FOUND CRACKED (CRACK 1.5 INCH LENGTH). RT WING I/B MAIN FLAP I/B AFT FLAP HINGE ARM FTG REPAIRED AS PER SRM 57-53-02-2R1 FIG 201 REV 44. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR WITH MATERSDR IPXA09656404Hinge Fitting · crackedINSPECTION TYPE:C LT WING I/B MAIN FLAP I/B AFT FLAP HINGE ARM FTG FOUND CRACKED (CRACK 1.5 INCH LENGTH). LT WING I/B MAIN FLAP I/B AFT FLAP HINGE ARM FTG REPAIRED AS PER SRM 57-53-02-2R1 FIG 201 REV 44. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR WITH MATERSDR IPXA09656347Floorboard · damagedINSPECTION TYPE:N/A D394848: MAIN CARGO DECK FLOOR BOARD POS 7L HAS 1 INCH DIA HOLE. FABRICATED PER B767-5320-9693-F.SDR IPXA09656348Fan · unknownFWD EQUIP COOLING OVERHEAT MSG. T/S REF FIM 21-58-00 FIG 115 INSP C/O EQUIPMENT COOLING SYS SUPPLY FAN & EXHAUST FAN INLET SCREEN, EQUIPMENT COOLING MANIFOLD INTER- CONNECT VALVE & MIXING MANIFOLD ALL OKAY. FWD RACK LOW FLOW DETECTOR & EXHAUST FAN REPLACED.SDR IPXA09656250Skin · damagedFUSELAGE SKIN DAMAGE AT BS 456 BETWEEN S25R AND S26R. REPAIRED IAW EO B767-5330-25673-F.SDR IPXA09656235Floor Panel · damagedFLOOR PANEL POS 10 DAMAGED. REPAIRED IAW EO B767-5320-33803-A.SDR IPXA09656234Floor Panel · damagedFLOOR PANEL POS 14 DAMAGED. REPAIRED IAW EO B767-5320-33802-A.SDR IPXA09656267Floor Panel · damagedINSPECTION TYPE:6C STA 933 TO 970, RBL 11 TO RBL 33, MC FLOOR PANEL FOUND DELAMINATION AND CRACK. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656302Fairing · delaminatedINSPECTION TYPE:6C LT WING O/B TRAILING EDGE FLAP L/E MID FAIRING DELAMINATION (2 PLACES) AT MID AREA. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-05 PAR 5A (1) FIG 5 REV 44.SDR IPXA09656301Flap · delaminatedINSPECTION TYPE:6C LT WING O/B TRAILING EDGE FLAP L/E MID FAIRING DELAMINATION AT O/B AREA. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-03 PAR 5A (1) FIG 5 REV 44.SDR IPXA09656300Fairing · delaminatedINSPECTION TYPE:6C LT WING O/B TRAILING EDGE FLAP L/E MID FAIRING DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-05 PAR 5C FIG 2 REV 44.SDR IPXA09656285Fairing · delaminatedINSPECTION TYPE:6C LT WING - I/B MAIN FLAP O/B LEADING EDGE FAIRING DELAMINATION. COMPOSITE WET LAY UP REPAIR CARRIED OUT AS PER SRM 51-70-03 PAR 5A (1) FIG 5, REV 44.SDR IPXA09656282Floor Panel · damagedINSPECTION TYPE:6C STN 283 - 412, RBL 78 TO RBL 88, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656281Floor Panel · damagedINSPECTION TYPE:6C STA 283 - 412, RBL 55 TO RBL 77, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656280Floor Panel · damagedINSPECTION TYPE:6C STN 544 - 654+22, LBL 11 TO RBL 11, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656279Floor Panel · damagedINSPECTION TYPE:6C STN 412 - 540, LBL 78 TO LBL 88 MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656278Floor Panel · damagedINSPECTION TYPE:6C STA 412 TO 530, LBL 11 TO RBL 11, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656277Floor Panel · damagedINSPECTION TYPE:6C STA 688 TO 764, RBL 78 TO RBL 88, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656276Floor Panel · damagedINSPECTION TYPE:6C STA 412 TO 540, LBL 55 TO LBL 77, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656275Floor Panel · damagedINSPECTION TYPE:6C STA 540 - 654 + 22, LBL 55 TO LBL 77, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.
Back to Boeing 767-34AF