SDR IPXA09656640Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 975 TO 1114 LBL 11 TO LBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656630Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 975 TO STA 1041, LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER SRM 53-01-01.SDR IPXA09656629Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL DAMAGE AT STA 833 TO 930, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656628Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 933 TO STA 970, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656627Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 833 TO STA 933, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656626Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 1480 TO 1598, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656625Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 970 - 1114 RBL 11 TO RBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656623Floor Panel · damagedINSPECTION TYPE:ETOP MCD FLOOR PANEL FOUND DAMAGE AT STA 540 TO 654+22, LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656622Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 412 TO STA 540, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656621Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 283 TO 412 RBL 55 TO RBL 77. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656620Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 833 TO 933, LBL 11 TO LBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656619Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 654+22 TO 690, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656618Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 975 TO 1114, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656617Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 412 TO STA 550, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656616Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 936 TO STA 985, RBL 77 TO RBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656615Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 368 TO 412, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656614Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 283 TO STA 412, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F.SDR IPXA09656613Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 550 TO STA 654+22, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656612Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 1207 TO 1344, LBL 33 TO L55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F.SDR IPXA09656611Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 975 TO 1114, LBL 55 TO LBL 77. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656610Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 985 TO STA 1087, RBL 77 TO RBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656609Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 764 TO 876, RBL 77 TO RBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F, AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656608Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 1370 - 1480, RBL 77 - R88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656605Floor Panel · puncturedINSPECTION TYPE:7C MCD FLOOR PANEL PUNCTURE AT STA 970, LBL 48. FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R, FIG 201 REV 44.SDR IPXA09656604Floor Panel · puncturedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND PUNCTURE AT STA 1197, RBL 82. FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R FIG 201 REV 44.SDR IPXA09656603Stiffener · crackedINSPECTION TYPE:7C MAIN EQUIPMENT CENTER STA 246 LBL 40 STIFFENER FOUND CRACK. MAIN EQUIPMENT CENTER STA 246 LBL 40 FLOORBEAM ATTACH STIFFENER REPAIRED AS PER SRM 53-10-51-2R-4, FIG 201, REV 44. THIS REPAIR IS CLASSIFIED AS CATEGORY 'B' MAJOR REPAIR AS PER SSDR IPXA09656599Attach Fitting · crackedINSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 LBL 50 CLIP FOUND CRACK (CRACK 1 INCH LENGTH). MAIN EQUIPMENT CENTER STA 246 LBL 50 FLOORBEAM ATTACH CLIP REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656597Attach Angle · crackedINSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 LBL 25 ANGLE FOUND CRACK (CRACK 0.875 INCH LENGTH). MAIN EQUIPMENT CENTER STA 246 LBL 25 FLOORBEAM ATTACH ANGLE REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656677Support · crackedINSPECTION TYPE:7C LEFT WING - L/E LES 675 FIXED SUPPORT WEB AT FRONT SPAR BRACKET FOUND CRACKED. LEFT WING L/E LES 675 FIXED SUPPORT WEB AFT FRONT SPAR BRACKET REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656672Skin · crackedINSPECTION TYPE:C LEFT WING NR 4 SLAT O/B NOSE SUPPORT SKIN FOUND CRACKED (CRACK 0.125 INCH LENGTH). LEFT WING NR 4 SLAT OSS 641.49 AREA NOSE SKIN REPAIRED AS PER SRM 57-43-01-2R2 FIG 201 REV 44. THIS REPAIR IS CLASSIFIED AS MAJOR REPAIR WITH MATERIAL 7075-0SDR IPXA09656658Skin · crackedINSPECTION TYPE:C RIGHT WING NR 9 SLAT I/B NOSE SUPPORT SKIN FOUND CRACKED (CRACK 0.125 INCH LENGTH). RIGHT WING NR 9 SLAT OSS 573.125 AREA NOSE SKIN REPAIRED AS PER SRM 57-43-01-2R2 FIG 201 REV 44. THIS REPAIR IS CLASSIFIED AS MAJOR REPAIR WITH MATERIAL 707SDR IPXA09656657Skin · crackedINSPECTION TYPE:C RIGHT WING NR 9 SLAT O/B NOSE SUPPORT SKIN FOUND CRACKED (CRACK 0.125 INCH LENGTH). RIGHT WING NR 9 SLAT OSS641.51 AREA NOSE SKIN REPAIRED AS PER SRM 57-43-01- 2R2 FIG 201 REV 44. THIS REPAIR IS CLASSIFIED AS MAJOR REPAIR WITH MATERIAL 7075SDR IPXA09656519Symbol Generator · smokeINSPECTION TYPE:ETOP ATB - CREW REPORTED SMOKE IN THE COCKPIT. EMERGENCY DECLARED. CAPTAIN'S EADI AND LEFT SYMBOL GENERATOR REPLACED AND OPN. CHECKED NORMAL P1-1, P1-2, & P1-3 INSTALLED PANEL. ASSOCIATE WIRINGS CONDITION INSPECTED NORMAL. CAPTAIN'S EADI CSDR IPXA09656506Transducer · malfunctionedINSPECTION TYPE:ETOP DIVERSION - ANTISKID MSG M403811 ETOPS REMOVED AND REPLACED NR 4 WHEEL TRANSDUCER IAW MM 32-42-06. OPS CHECK GOOD. THIS CLEARS M403811.SDR IPXA09656472Skin · dentedINSPECTION TYPE:N/A RIGHT TRAILING EDGE I/B AFT FLAP LOWER SKIN DENT. REPAIRED PER EO B767-5750-34041-A.SDR IPXA09656471Cdu · burnedPRIOR TO TAKEOFF HEARD A CRACKLING NOISE AND SMELLED ELECTRICAL BURNING RECEIVED A "L FMC FAIL IN EICAS" AND LOST THE R FMC CDU. CDU BREAKER OPENED AND WOULD NOT RESET. IDENTIFIED RT CDU HAD A BURNED ODOR REPLACED CDU PER MM 34-61-02-2. REPLACED LT FMC PER SDR IPXA09656496Floorbeam · crackedINSPECTION TYPE:7C MAIN DECK BS 246 LBL 27 FLOORBEAM WEB FOUND CRACK. MAIN DECK BS 246 LBL 27 FLOORBEAM WEB REPAIRED AS PER HX RS NO. R53-15-36357 REV A. THIS REPAIR IS CLASSIFIED AS TIME LIMITED UNTIL JUN 25, 2010. PENDING COMPLETION OF THE FATIGUE AND DAMSDR IPXA09656480Skin · misrepairedINSPECTION TYPE:7C SURVEY SEQUENCE 309-W3-06 LT WING NR 4 SLAT OSS 647 NOSE SKIN REPAIR FASTENER SPACING IS DIFFERENT AS PER SRM. SURVEY SEQUENCE 309-W3-06 LT WING NR 4 SLAT NOSE SKIN AT OSS647 REPAIRED AS PER SRM 57-43-01-2R2 FIG 201 REV 44, THIS REPAIR IS CSDR IPXA09656429Fairing · delaminatedINSPECTION TYPE:C LT WING I/B MAIN FLAP O/B LEADING EDGE FAIRING DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-05 PAR 5A (1) FIG 5 REV 44.SDR IPXA09656428Fairing · delaminatedINSPECTION TYPE:C RT WING I/B MAIN FLAP O/B L/E FAIRING DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-05 PAR 5A (1) FIG 5 REV 44.SDR IPXA09656498Skin · misrepairedINSPECTION TYPE:7C SURVEY SEQUENCE 309-F1-01 FUSELAGE BETWEEN BS 385 TO 400 AND STR 30R - 32R EXISTING REPAIR PATCH DOES NOT CORRELATE TO A SRM. FUS SKIN REPAIRED AS PER RS NO. R53-10-36353 REV A & IPXA EO NO. B767-5330-33985-A. THIS REPAIR IS CLASSIFIED AS SDR IPXA09656495Rib · crackedINSPECTION TYPE:7C RT WING I/B AILERON I/B HINGE SUPPORT RIB UPPER AFT FLANGE FOUND CRACKED. RT WING I/B AILERON I/B HINGE SUPPORT FIG RIB REPAIR AS PER HX RS NO. 57-55-36355 REV A. THIS IS A PERMANENT REPAIR WITH MATERIAL AND 10133-2002-7075T6511 AS REPAIR SDR IPXA09656481Skin · crackedINSPECTION TYPE:7C LT WING NR 4 SLAT NOSE SKIN I/B SUPPORT WEB FASTENER HOLE AREA FOUND CRACKED. LT WING NR 4 SLAT NOSE SKIN AT OSS572-875 REPAIR AS PER SRM 57-43-01-2R2, FIG 201, REV 44. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR WITH MATERIAL 7075-0-0071ISDR IPXA09656435Slat · chafedINSPECTION TYPE:C LT WING NR 1 SLAT LOWER AREA AT O/B AUX TRACK FOUND CHAFE. METAL HOT BOND REPAIR PERFORMED AS PER SRM REV 44, 51-70-10 REPAIR 4 FIG 202.SDR IPXA09656432Skin · crackedINSPECTION TYPE:C RT WING NR 9 SLAT NOSE SKIN I/B SUPPORT WEB FASTENER HOLE AREA FOUND CRACKED (0.125 INCH LENGTH). RT WING NR 9 SLAT NOSE SKIN AT OSS 572.875 REPAIRED AS PER SRM 57-43-01-2R2 FIG 201 REV 44. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR WITH MSDR IPXA09656431Skin · crackedINSPECTION TYPE:C RT WING NR 9 SLAT NOSE SKIN O/B SUPPORT WEB FASTENER HOLE AREA FOUND CRACKED (0.125 INCH LENGTH). RT WING NR 9 SLAT NOSE SKIN AT OSS 641.615 REPAIRED AS PER SRM 57-43-01-2R2 FIG 201 REV 44. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR WITH MSDR IPXA09656430Skin Panel · delaminatedINSPECTION TYPE:C EMP - VERTICAL STAB LT EXTERIOR SURFACE FWD MIDDLE AREA FOUND DELAMINATION. METAL HOT BOND REPAIR PERFORMED AS PER SRM 51-70-10 REV 44, REPAIR 4 FIG 201.SDR IPXA09656409Floor Panel · crackedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND CRACK 2 INCH LONG AT STA 975 TO STA 1043 LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656399Floor Panel · puncturedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND PUNCTURED AT STA 650 RBL 6. FLOOR PANEL REPAIR AS PER SRM 53-00-50-2R FIG 201, REV 44.SDR IPXA09656398Floor Panel · puncturedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND PUNCTURED AT STA 1452 RBL 48. FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R FIG 201 REV 44.
Back to Boeing 767-34AF