SDR IPXA10660166Floor Panel · puncturedINSPECTION TYPE:7C, MCD STA 731 TO 833, LBL 11 TO RBL 11 FLR PANEL FND SEVERAL PUNCTURES TOGETHER WITH 6 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10660165Floor Panel · puncturedINSPECTION TYPE:7C, MCD STA 731 TO 833, LBL 55 TO LBL 77 FLOOR PANEL FND PUNCTURE 1.5"X2" AT 2 LOCATIONS TOGETHER WITH 4 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10660164Floor Panel · damagedINSPECTION TYPE:7C, MCD STA 1197+22 TO 1197+110, RBL 77 TO RBL 88 FLR PANEL FOUND DAMAGED WITH 3 PUNCTURES AND 3 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10660169Floor Panel · crackedINSPECTION TYPE:7C, DMI NR D423985 - MCD POS 7R FLOOR PANEL HAS 3.5" BY 2.5" DENT WITH .7500" CRACK. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10660168Floor Panel · dentedINSPECTION TYPE:7C, DMI NR D424945 MCD FLOOR PANEL DENT AT POS 11L. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10660167Floor Panel · damagedINSPECTION TYPE:7C, DMI NR D424915 - R UPR MAIN CARGO DECK FLR PANEL DAMAGED AT POS 7L. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10659995Floor Panel · damagedD418763 MCD FLOOR PANEL DAMAGED AT POSITION 10L MFG AND INSTALLED IAW EO B767-4320-9693-G, POS 10L.SDR IPXA10659951Connector · intermittentINSPECTION TYPE: L3, WINDOW WORKS ONLY INTERMITTENT. T/S C/O FOUND J9 CONNNECTION INTERMITTENT ON L3 WINDOW. CLEANED CONNECTION ON WINDOW AND RETAPED WINDOW THREAD. INSTALLED NEW SCREW AND WASHER. C/O TEST IAW AMM 30-41-00-5. BITE TEST OK AND OPS SATIS. THIS SDR IPXA10659874Floor Panel · puncturedMAIN CARGO POSITION 6L MOST OTBD FLOOR PANEL HAS 2 SMALL PUNCTURES. 2 SMALL PUNCTURES IN ZONE 1 THROUGH FIRST PLY ONLY. FIRST MEASURES .5" BY .1280", SECOND MEASURES .5" BY .2500" AND ARE 4 INCHES APART FROM EACH OTHER. ACCOMPLISHED MAJOR REPAIR IAW EO B76SDR IPXA10659938Stringer · misrepairedINSPECTION TYPE:C, FUSELAGE STA524 STR25L EXISTING REPAIR MUST BE REMOVED AND REACCOMPLISHED IAW SRM. GIVEN IN VALIDATION EO B767-5100-36544 APPENDIX B ITEM 1 FX AT BTN BS511.5 & 532.5 STR25L STR REPAIRED IAW R53-00-36725 & EO B767-5330-37838, ORG MATL 7075T6 SDR IPXA10659893Fairing · delaminatedINSPECTION TYPE:C, LT WING OTBD T/E FLAP MID L/E FAIRING INBD AREA DELAMINATION. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05 PAR 5C, FIG 2.SDR IPXA10659749Floor Panel · damagedMAIN CARGO DECK FLOOR AT POS 6L HAS 1" HOLE IN IT. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA10659748Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL AT POS 6 L HAS .6250 X .2500 HOLE. REPAIRED IAW SRM 53-00-50-22R.SDR IPXA10659746Floor Panel · damagedMAIN DECK FLOORBOARD POSITION 4R HAS 2 AT HOLES. HOLES MEASURE .2500" X .3750" AND .2500" X .5". REPAIRED IAW 53-00-50-2R.SDR IPXA10659739Floor Panel · puncturedMAIN CARGO DECK FLOOR PANEL AT POS 8R HAS 1 " HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA10659738Floor Panel · puncturedMC FLOOR PANEL AT POS 8L HAS 1" HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA10659737Floor Panel · damagedMAIN DECK FLOOR PANEL AT POS 12L HAS 1" HOLE. REPAIRED IAW 767SRM 53-00-50-2R.SDR IPXA10659736Floor Panel · damagedINSPECTION TYPE:N/A MAIN CARGO DECK FLOOR PANEL HAS 2 HOLES. HOLES MEASURES 6.7500 X 3.5 AN D 3.5 DIAMETER. REPAIRED IAW SRM 53-00-50.SDR IPXA10659735Floor Panel · puncturedMAIN CARGO DECK FLOOR PNL AT POS 12L OTBD HAS 1 1/4 X 1 HOLE THUR BOTH SKINS FABRICATED PNL IAW EO B767-5320-9693-G.SDR IPXA10659901Skin · delaminatedINSPECTION TYPE:C, LT WING INBD AFT FLAP UPPER SURFACE INBD AREA FOUND DELAM. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R REPAIR 4, FIG 201 SH.1.SDR IPXA10659846Fairing · delaminatedINSPECTION TYPE:C, LT WING INBD MAIN FLAP OTBD L/E FAIRING DELAMINATION. FIBERGLASS FABRIC PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05 PAR 5A (1) FIG 5.SDR IPXA10659809Tee Fitting · corrodedINSPECTION TYPE:C, FUS STA955 LT TEE FITTING FWD LOWER HOLE FOUND CORROSION AT MATING SURFACE AS MARKED. FUSELAGE STA955 REAR SPAR BULKHEAD SIDE FITTING AERA TEE FITTING REPLACED IAW SRM 51-10-02, REV 46 AND INSTALLED IAW EO B767-5350-17922, APPENDIX C.SDR IPXA10659961Support · crackedINSPECTION TYPE:8C, NR 1 PYLON MID SPAR WEB RT SUPPORT CLIP FOUND CRACKED JUST AT NAC STA 285.45 CRACK LENGTH 1" NR 1 PYLON MID SPAR WEB RT SUPPORT CLIP REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02, REV 46.SDR IPXA10659916Fairing · delaminatedINSPECTION TYPE:C, LT WING OTBD T/E FLAP MID L/E FAIRING OTBD AREA DELAMINAION. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05 PAR 5C, FIG 2.SDR IPXA10659903Support · crackedINSPECTION TYPE:C, LT WING FIXED FAIRING UPPER SUPPORT WEB AFT FRONT SPAR SUPPORT CLIP FOUND CRACKED JUST AT OFSS549. LT WING FIXED FAIRING UPPER SUPORT WEB AFT FRONT SPAR SUPPORT CLIP AT OFSS549 AREA REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02.SDR IPXA10659683Eec · faultyDURING ENGINE START ON NR 2 EGT DID NOT RISE. ON SECOND START WITH ENG 2 START SELECTOR IN BOTH. NORMAL START. T/S C/O IAW FIM 74-00-00 FIG, 107 SH2. R & R ENG NR 2 EEC IAW AMM 73-21-15-4 . REPLACED BOTH IGNITOR PLUGS IAW AMM 74-21-02-4. C/O TEST IAW AMM 74-SDR IPXA10659941Support Fitting · crackedINSPECTION TYPE:C, RT WING NR 9 SLAT OTBD ROTARY ACTUATOR OTBD SUPPORT FITTING FWD FLANGE FOUND CRACKED JUST AT OSS648.595. RT WING NR 9 SLAT OTBD ROTARY ACT OTBD SUPPORT FITTING AT OSS648.595 FWD FLANGE CRACKED AREA REPAIRED IAW RS R57-00-36731 & B767-5740-SDR IPXA10659902Support · crackedINSPECTION TYPE:C, RT WING FIXED FAIRING UPPER SUPPORT WEB AFT FRONT SPAR SUPPORT CLIP FOUND CRACKED JUST AT OFSS549. RT WING FIXED FAIRING UPPER SUPPORT WEB AFT FRONT SPAR SUPPORT CLIP AT OFSS549 AREA REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02.SDR IPXA10659897Seat Track · corrodedINSPECTION TYPE:C, M/DECK STA 742-786 LBL 77.5" SEAT TRACK FLANGE CORROSION M/D AT BTN STA 709.45-789.75 LBL 77.5" SEAT TRACK REPAIRED IAW SRM 53-00-52-2R9 FIG201, ORG MATL IS BAC1520-2772-7150T77511, BLEND OUT DEPTH 0.019" X 0.75" X 1.25" AT STA 742.5 AND 0.0SDR IPXA10659896Seat Track · corrodedINSPECTION TYPE:C, M/DECK STA742 TO 764 RBL11 SEAT TRACK FLANGE CORROSION M/D AT BTN STA 709.45 & 782.5 RBL 11 SEAT TRACK REPAIRED IAW SRM 53-00-52-2R9, FIG 201, ORG MATL IS BAC1520-2772-7150-T77511, CORROSION BLENDED OUT 0.032" X 1" X 3" AT STA 737.5 RBL 11" SDR IPXA10659875Stiffener · crackedINSPECTION TYPE:C, RT WING FRONT SPAR STIFFENER UPPER AREA FOUND CRACKED JUST AT OFSS532. RT WING FRONT SPAR STIFFENER JUST AT OFSS532 AREA FABRICATED WITH MATL AND10133-2403 7075T6511 EXTRUSION, REPLACED AND INSTALLED IAW RS R57-21-36728 & EO B767-5710-37790SDR IPXA10659833Panel · delaminatedINSPECTION TYPE:C, LT WING NR 5 SPOILER UPPER SURFACE INBD AREA EXISTING REPAIR DELAMINATION. GRAPHITE FABRIC PRE PREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-04 PAR 5A (1) FIG 5.SDR IPXA10659767Fitting · crackedINSPECTION TYPE:C, RT WING INBD FLAP INBD HINGE FTG FLANGE AREA FOUND CRACKED. RT WING INBD MAIN FLAP HINGE FTG AT IFS179.75 REPAIRED IAW SRM 57-53-02-2R1, FIG 201, ORG MATL IS 7075T73 FORGING, CRK LENGTH AT INBD FLANGE IS 0.875" AND OTBD FLANGE IS 1" DAMAGEDSDR IPXA10659937Attach Fitting · crackedINSPECTION TYPE:C, FUS MEC COMPT STA 246 FLOORBEAM ATT CLIP FOUND CRACKED AT RBL10". FUS MEC COMPT STA 246 FLOORBEAM ATT CLIP REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02.SDR IPXA10659894Longeron Splice · wornINSPECTION TYPE:C, FUSELAGE SECTION 45 RT STA955 REAR SPAR BULKHEAD FITTING HOLE WORN AT LONGERON SPLICE AREA. FUSELAGE SECTION 45 RT STA955 REAR SPAR BULKHEAD FITTING LONGERON SPLICE HOLE WORN AREA REPAIRED IAW RS R53-50-36729 & EO B767-5310-37821. ORG MATL SDR IPXA10659880Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT BS 985 TO 1087 LBL 77" TO LBL 88". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659878Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT BS 764 TO 873 LBL 77" TO LBL 88". FLOOR PANEL FABRICATE IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659845Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH WITH PUNCTURE HOLE AT BS 873 TO 933 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659844Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH WITH PUNCTURE HOLE AT BS 933 TO 985 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659817Failsafe · crackedINSPECTION TYPE:C, CRACKS WERE FOUND AT BS 955 BULKHEAD RT SIDE LOWER BOLT HOLE AT FAIL SAFE STRAP RUNNING 4 AND 9 O'CLOCK POSITION WITH THROUGH THICKNESS INDICATION. FUSELAGE STA 955 REAR SPAR BULKHEAD SIDE FITTING FAIL SAFE STRAP REPAIRED IAW UPS EO B767-53SDR IPXA10659816Failsafe · crackedINSP TYPE:C, CRACKS WERE FOUND AT BS 955 BULKHEAD LT SIDE AT LOWER BOLT HOLE OF FAIL SAFE STRAP CRACK RUNNING FWD & AFT WITH THROUGH THICKNESS INDICATION. FUSELAGE STA 955 REAR SPAR BULKHEAD SIDE FITTING FAIL SAFE STRAP REPAIRED IAWUPS EO B767-5350-17922 APPESDR IPXA10659814Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT BS 1087 TO 1197+22 LBL77" TO LBL88". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01SDR IPXA10659813Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT STN1197+22 TO 1207 LBL77" TO LBL88". FLOOR PANEL FABRICATED AS IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659811Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT STN 1207 TO 1351 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659810Tee Fitting · crackedINSPECTION TYPE:C, CRACK WAS FOUND AT BS 955 BULKHEAD TEE FITTING LOWER BOLT HOLE OTBD SURFACE RUNNING 7 O'CLOCK WITH .0652" DEPTH APPROX BS 955 REAR SPAR BULKHEAD SIDE FITTING AREA TEE FITTING REPLACED IAW SRM 51-10-02, REV 46. AND INSTALLED IAW UPS EO B767-SDR IPXA10659798Skin · crackedINSPECTION TYPE:C, RT WING NR 10 SLAT OTBD NOSE SKIN RIVET HOLE FOUND CRACKED. RT WING NR 10 SLAT L/E OTBD NOSE SKIN AT OSS792.5 AREA SKIN REPAIRED IAW SRM 57-43-01-2R2 FIG 201, ORG MATL IS CLAD7075T6-0.063IN, CRK LENGTH IS 0.1" DAMAGED CUTOUT IS 8.875" X 7" SDR IPXA10659793Skin · crackedINSPECTION TYPE:C, LT WING NR4 SLAT L/E INBD NOSE SKIN RIVET HOLE FOUND CRACKED. LT WING NR 4 SLAT L/E INBD NOSE SKIN AT OSS572.5 AREA SKIN REPAIRED IAW SRM 57-43-01-2R2 FIG, 201, ORG MATL IS CLAD7075T6-0.063IN, CRK LENGTH IS 0.11" DAMAGED CUTOUT IS 8.875" X SDR IPXA10659940Skin · misrepairedINSPECTION TYPE:C SURVEY SEQUENCE NR 303-F1-04 FUSELAGE SKIN AT BETWEEN STA 1600 TO STA 1623 AND STR34L - 36L AREA EXISTING REPAIR WAS FOUND AND DOES NOT CORRELATED TO A SRM. SURVEY SEQ NR 303-F1-04 FX SKIN AT BTN STA1600-1623 & STR34L-36L AREA REPAIRED IAW RSDR IPXA10659895Skin · misrepairedINSPECTION TYPE:C, SURVEY SEQUENCE NO 303-F1-09 FUSELAGE SKIN AT BETWEEN STA 434-453 AND S25R - 26R AREA EXISTING REPAIR PATCH WAS FOUND AND DOES NOT CORRELATE TO A SRM. SURVEY SEQ NO 303-F1-09 FX SKIN AT BTN STA434-453 & STR25R-26R AREA SKIN REPAIRED IAW RS SDR IPXA10659879Floor Panel · puncturedINSPECTION TYPE:C, DMI D423102 HOLE REPAIR MCD POS 7, RT 25 INCHES FROM AFT EDGE & 4.5" INBD LT SIDE. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.
Back to Boeing 767-34AF