What was found
INSPECTION TYPE:C, FUSELAGE STA524 STR25L EXISTING REPAIR MUST BE REMOVED AND REACCOMPLISHED IAW SRM. GIVEN IN VALIDATION EO B767-5100-36544 APPENDIX B ITEM 1 FX AT BTN BS511.5 & 532.5 STR25L STR REPAIRED IAW R53-00-36725 & EO B767-5330-37838, ORG MATL 7075T6 BARE.120" TAPER STRINGER. STR CUTOFF LENGTH IS 21", 0.063" AT CUT LINE AREA. REPAIR LENGTH IS 37.25" THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR WITH MATL BAC1498-209-7075T62 AS REPAIR INITIAL SECTION. THIS REPAIR IS TIME LIMITED UNTIL 14MAY2012.