Boeing 767-3S1

Service difficulty reports · 974

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '7673S1'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UIEA2013041400216Warning Light · false activationLEFT PRSOV BITE SWITCH WIRE FAULT. PERFORMED AIR SUPPLY CONTROL SYSTEM TEST WITH NO FAULTS NOTED.Apr 14, 2013 · N640GT · Boeing 7673S1 · Pneumatic SystemSDR UIEA2013041400215Fire Bottle · dischargedENGINE DISCHARGE FAULT LIGHTS ARE ON. R & R ENGINES NR 1 AND NR 2 FIRE BOTTLES. OPS CHECKED NORMAL.Apr 14, 2013 · N640GT · Boeing 7673S1 · Fire Bottle, FixedSDR UIEA2013041400214Knob · malfunctionedEFIS CONTROL PANEL RANGE SELECT KNOB; WHEN YOU SELECT 80 NM, THE DISPLAY SHOWS 40 NM. PERFORMED OPS CHECK OF EFIS CONTROL PANEL RANGE SELECT KNOB-CHECK GOOD IAW AMM 34-22-00.Apr 14, 2013 · N640GT · Boeing 7673S1 · Integrated Flight SystemSDR UIEA2013041400213Warning Light · false activationEICAS MESSAGE "FUEL QUANITY BITE" DISPLAYED. PERFORMED SATISFACTORY FUEL QTY BITE PROCEDURE. RETEST OK.Apr 14, 2013 · N640GT · Boeing 7673S1 · Fuel Quantity IndicatorSDR UIEA2013041400212Bulb · inoperativeLT WING EXTERIOR EMERGENCY EXIT LIGHT (CENTER) INOPERATIVE. R & R LT WING EXTERIOR EMERGENCY LIGHT BULB.Apr 14, 2013 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2013041400211Cable · looseUPPER SAFTEY CABLE ON CONNECTION AT RT PACK COMPRESSOR OUTLET CONNECTION IS NOT ATTACHED. CORRECTLY INSTALLED CABLE/SAFTEY ON RT PACK COMPRESSOR OUTLET.Apr 14, 2013 · N640GT · Boeing 7673S1 · Air Conditioning System WiringSDR UIEA2013041400210Nut · looseRT PACK HAS JAMB NUTS LOOSE ON PRIMARY HEAT EXCHANGER FWD MOUNT RODS. TIGHTENED RT PACK JAMB NUTS ON PRIMARY HEAT EXCHANGER FWD MOUNT RODS.Apr 14, 2013 · N640GT · Boeing 7673S1 · Fuselage Miscellaneous StructureSDR UIEA2013041400209Bonding Wire · brokenRT PACK HAS BROKEN BONDING WIRE AT SECONDARY HEAT EXCHANGER INLET CONNECTOR TO COMPRESSOR OUTLET LINE. REPLACED BONDING WIRE AND ATTACHING HARDWARE AT SECONDARY HEAT EXCHANGER INLET CONNECTOR TO COMPRESSOR OUTLET LINE.Apr 14, 2013 · N640GT · Boeing 7673S1 · Air Conditioning System WiringSDR UIEA2013041400208Pressure Blkhd · gougedGOUGE NOTED ON AFT PRESSURE BULKHEAD AT APPROX STA 1582 LOCATED ON R/T SIDE LOWER SECTION. REMOVED DAMAGE AREA AND ACCOMPLISHED REPAIR ON AFT PRESSURE BULKHEAD.Apr 14, 2013 · N640GT · Boeing 7673S1 · Fuselage Main, BulkheadSDR UIEA2013041400207Bracket · chafedFIRE LOOP BRACKET ON LT APU DOOR 315 HAS CHAFE MARKS AND A HOLE. REMOVED BRACKET FABRICATION NEW AND INSTALLED NEW BRACKET.Apr 14, 2013 · N640GT · Boeing 7673S1 · Fire DetectionSDR UIEA2013041300206Warning Message · false activationEICAS MESSAGE " HI FLOW INHIBIT" DISPLAYED, PEROFRMED FIM 21-51, FAULT TREE 813 AND RESET- NO FAULTS AT THIS TIME.Apr 13, 2013 · N640GT · Boeing 7673S1 · Central WarningSDR UIEA2013041300205Cable · looseUPPER APU STARTER CABLES LOOSE. RETORQUED UPPER STARTER CABLES ON APU.Apr 13, 2013 · N640GT · Boeing 7673S1 · Electrical Power System WiringSDR UIEA2013041300204Indication Sys · malfunctionedNO EPCS INFORMATION DISPLAYED DURING TEST. PERFORMED EPCS MESSAGES READ OUT PROCEDURE, NO FAULT MESSAGES- SYSTEM CHECK OK.Apr 13, 2013 · N640GT · Boeing 7673S1 · Central ComputersSDR UIEA2013041300203Warning Message · false activationEICAS MESSAGE " L PIMU" DISPLAYED. PERFORMED SATISFACTORY PIMU BITE PROCEDURE.Apr 13, 2013 · N640GT · Boeing 7673S1 · Central WarningSDR UIEA2013041300202Panel · brokenNO SMOKING & SEAT BELT PANEL BROKEN AT SEAT 3LJ. R & R BROKEN PANEL.Apr 13, 2013 · N640GT · Boeing 7673S1 · Fuselage Miscellaneous StructureSDR UIEA2013041300201Bracket · wornHARDWARE HAS WEAR ON ENG NR 1, RT SIDE POSITION BRACKET. R & R HARDWARE.Apr 13, 2013 · N640GT · Boeing 7673S1 · Engine Bleed Air SystemSDR UIEA2013041300200Rod · wornENG 1 COOLING DUCT POSITION ROD ON RT SIDE WORN OUT. R & R POSITION ROD FOR COOLING DUCT ON NR 1 ENG RT SIDE.Apr 13, 2013 · N640GT · Boeing 7673S1 · Engine Bleed Air SystemSDR UIEA2013041300199Rod · brokenTCC VENT DUCT SUPPORT ROD & ON NR 2 ENG OTBD SIDE BROKEN. R & R BROKEN SUPPORT ROD ON NR 2 ENG.Apr 13, 2013 · N640GT · Boeing 7673S1 · Engine Bleed Air SystemSDR UIEA2013041300198Screw · missingENG 2 FAN AIR VALVE & OTBD FLANGE MISSING 3 SCREWS. REPLACED SCREW.Apr 13, 2013 · N640GT · Boeing 7673S1 · Pneumatic Distribution SystemSDR UIEA2013041300197Block · unsecureCLAMP BLOCK FOR HYD LINES FOUND IN BOTTOM OF NR 2 PYLON. INSTALLED CLAMP BLOCK OF HYDRAULIC LINES.Apr 13, 2013 · N640GT · Boeing 7673S1 · Nacelle/Pylon Miscellaneous StructureSDR UIEA2013041300196Shield · crackedCRACK ON NR 2 ENG WIRE HARNESS SHIELD ; INBD SIDE OF FAN AREA (R & R BRACKET ASSY ON LT ; INBD ;SIDE OF NR 2 ENG).Apr 13, 2013 · N640GT · Boeing 7673S1 · Engine Fuel System WiringSDR UIEA2013041300195Fire Detector · inoperativeWHEEL WELL FIRE DETECTION, FIRE BELL INOPERATIVE. RESET CIRCUT BREAKERS ON P11- PERFORMED SATISFACTORY INTERUPT TEST OF REMOTE APU FIRE HORN.Apr 13, 2013 · N640GT · Boeing 7673S1 · Fire DetectionSDR UIEA2013041300194Bulb · inoperativeLT AFT FUEL PUMP PRESSURE LIGHT INOPERATIVE. R & R LIGHT BULB.Apr 13, 2013 · N640GT · Boeing 7673S1 · Instrument PanelSDR UIEA2013041300193Cooling Duct · chafedCHAFE ON LT ENGINE, LT SIDE; AFT, TURBINE CASE COOLING DUCT (R & R NR 1 ENGINE LOW PREASURE RECOUP DUCT INTO 9 O'CLOCK POSITION).Apr 13, 2013 · N640GT · Boeing 7673S1 · Engine Bleed Air SystemSDR UIEA2013030600118Light · inoperativeSIDE WALL EMERGENCY LIGHT AT ROW 10 LT & RT INOPERATIVE. OPENMar 6, 2013 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2013030300111Battery · inoperativeF/A EMERGENCY FLASHLIGHT AT MID RT F/A STATION DID NOT HAVE A FLASHING LIGHT. REPLACED F/A FLASHLIGHT BATTERY IAW AMM 25-64-00. OPS CHECKS NORMAL.Mar 3, 2013 · N640GT · Boeing 7673S1 · Emergency EquipmentSDR UIEA2013022600106Waste Tank · inoperativeDUE LAVS INOPERATIVE, DIVERED, FWD LAV TANK SERVICED, MID CTR, MID RT & AFT LT OPS NORMAL IAW AMM 12-17-01 TRANSFERED AFT WASTE TANK TO MDDR 38112 CT FWD , MID LT; AFT RT ARE INOPERATIVE.Feb 26, 2013 · N640GT · Boeing 7673S1 · Waste Disposal SystemSDR UIEA2013021800091Generator · malfunctionedRT GENERATOR DIDN`T COME ON LINE AFTER START RESET & OPS NORMAL. RAN NR 2 ENGINE IAW AMM 71-00--00. GEN CAME ON LINE, OPS GOOD, REF SL767 - SL24-054, ALL CHECKED GOOD.Feb 18, 2013 · N640GT · Boeing 7673S1 · AC Generator-AlternatorSDR UIEA2013020500068Processor · malfunctionedFUEL QTY PROCESSOR SHOWS B7 FAULT. SWITCH FOR .5 SYS BROKEN OFF. REMOVED & REPLACED PROCESSOR FUEL QTY IAW MM 28-41-00.Feb 2, 2013 · N640GT · Boeing 7673S1 · Fuel Quantity IndicatorSDR UIEA2012123100572Connector · failedHMG TEST ON P61 PANEL, INOPERATIVE. REPLACED CONNECTOR IAW SWPM 20-61-11. OPS CHECKED GOOD.Dec 31, 2012 · N640GT · Boeing 7673S1 · Electrical Power System WiringSDR UIEA2012123100573Lamp · inoperativeEMERGENCY EXIT LIGHT AFT OF L2 DOOR INOPERATIVE. LAMPED EXIT LIGHT IAW AMM 33-51-06. OPS CHECKED GOOD.Dec 31, 2012 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2012123100575Cable · misinstalledCABLE IMPROPERLY INSTALLED ON LT OVER WING SLIDE BOTTLE. R & R LT OVER WING CYLINDER BOTTLE IAW AMM 25-65-02.Dec 31, 2012 · N640GT · Boeing 7673S1 · Escape SlideSDR UIEA2012123100574Warning Message · false activationLEFT PIMU MESSAGE DISPLAYED. TROUBLESHOT AND PERFORMED TEST NR 12. GROUND TEST/ EEC ACTUATORS IAW AMM 71-00-00/101. NO FAULTS FOUND. ORIG FAULT 3T3-27B LPTC FEEDBACK CLEARED. DID NOT RETURN ON TESTING.Dec 30, 2012 · N640GT · Boeing 7673S1 · Central WarningSDR UIEA2012122700567Skin · damagedDURING A CHECK INSPECTION OF THE DATUM ACFT, FOUND A SMALL PUNCTURE ON THE RT WING LANDING GEAR - DOOR SKIN. THE DAMAGE AREA FALLS IN THE CRITICAL AREA OF SRM 52-80-02-01-01. ALLOWABLE DAMAGE GENERAL. THE SRM DOESN'T PROVIDE THE ALLOWABLE LIMITS ON THIS AREDec 26, 2012 · N640GT · Boeing 7673S1 · Landing Gear DoorsSDR UIEA2012121800554Seal Depressor · damagedDAMAGE TO THE LOWER LOBE -FORWARD CARGO DOOR - BS 478 SEAL DEPRESSOR WAS FOUND (REF FIG 1), MEASURING 1.5" AND LOCATED AT THE SEAL DEPRESSOR SPLICE AREA. DAMAGE WAS DETERMINED TO BE BEYOND THE REPAIR LIMITS IAW THE SRM 53-00-15, FIG 201, REPAIR 2. DISPOSITIODec 18, 2012 · N640GT · Boeing 7673S1 · Fuselage Miscellaneous StructureSDR UIEA2012121300547Sensor · malfunctionedRT ENGINE EEC C-2, RT PIMU MX MESSAGE DISPLAYED. R & R RT ENGINE T-12 SENSOR, IAW AMM 73-21-06, OPS CHECKED GOOD. GROUND OPS CHECKED GOOD.Dec 13, 2012 · N640GT · Boeing 7673S1 · Fuel Controlling SystemSDR UIEA2012111700531Warning Message · illuminatedPILOT REPORT RT PACK OFF LIGHT AND EICAS MESSAGE NOT ILLUMINATED IN OFF POSITION.Nov 17, 2012 · N640GT · Boeing 7673S1 · Cabin Cooling SystemSDR UIEA2012111600529Switch · failedLEFT FWR FUEL PUMP EICAS MESSAGE IN CRUISE AT FL 410, REPLACED LOW PRESSURE SWITCH IAW AMM 28-42-01 AND CONNECTOR D1530, IAW WDM28-42-11.Nov 16, 2012 · N640GT · Boeing 7673S1 · Aircraft Fuel SystemSDR UIEA2012110300510Pump · failedLT FWD BOOST PUMP LOW PRESSURE LIGHT ILLUMINATED WITH LT FWD FUEL PUMP EICAS MESSAGE. REPLACED LT FWD BOOST PUMP WITH REPAIRED UNIT IAW AMM 28-22-03, LEAK AND OPS CHECKED GOOD.Nov 2, 2012 · N640GT · Boeing 7673S1 · Fuel Boost PumpSDR UIEA2012110100508Warning Light · illuminatedLEFT FWD LOW PRESSURE FUEL LIGHT ILLUMINATED WITH LEFT FWD FUEL PUMP EICAS. OPENNov 1, 2012 · N640GT · Boeing 7673S1 · Fuel Pressure IndicatorSDR UIEA2012102700497Door · damagedHYD SERVICE BAY DOOR CAME OPEN IN FLIGHT. DOOR DAMAGED. REPAIRED IAW EO 6753A096.Oct 26, 2012 · N640GT · Boeing 7673S1 · Service DoorsSDR UIEA2012102400494Connector · looseLEFT ENGINE EEC C1 STATUS MESSAGE, DISPLAYED ON LANDING. PERFORMED FAULT ISOLATION 73-21 FAULT TREE 885 AND FAULT TASK A74-353-29. PMA POWER FOUND CONNECTOR P103 ON PMA LOOSE CLEANED AND REINSTALLED IAW AMM 20-60-00 CHECK OK IAW FAULT TREE.Oct 24, 2012 · N640GT · Boeing 7673S1 · Engine Fuel System WiringSDR UIEA2012101500477Warning Light · false activationLEFT FWD FUEL PUMP PRESSURE LIGHT ON APPROX FL370. FUEL IN TANK 11.2. SWITCHED PUMP OFF IAW QRH. SUMPED ALL TANKS. NO CONTAMINATION FOUND. TRANSFERRED FUEL, PUMP OPERATES NORMAL REF MM 28-22-03 AND MM 12-11-10.Oct 15, 2012 · N640GT · Boeing 7673S1 · Fuel Indicating SystemSDR UIEA2012101500475Sensor · failedLT PACK OFF, LT PACK TEMP (1) FOUND COMPRESSOR SENSOR FAULT ON LT PACK CONTROLLER IAW FIM 21-51, FAULT TREE 803. CLEANED CONNECTOR AT TS41 IAW SWPM 20-60-01. SYS BITE CHECKED GOOD IAW FIM 21-51 FAULT TREE 803. (2) LOG PAGE 587949 - IAW MCC REQUEST R & R LT POct 13, 2012 · N640GT · Boeing 7673S1 · Cabin Cooling SystemSDR UIEA2012101000462Connector · damagedRIGHT BLEED DUCT LEAK EICAS MESSAGE ON INTERMITTENTLY 3 TIMES DURING CLIMBOUT. REMOVED CONNECTOR D10222 AND WIRES W062-786R-22, W062-801R-22, W062-100K-2, IAW WDM 91 HOOKUP LIST D10222 AND WDM 26-18-21 AND SWPM 20-00-00.Oct 9, 2012 · N640GT · Boeing 7673S1 · Fire Protection System WiringSDR UIEA2012101000460Unknown · unknownFMS MESSAGE "FUEL DISAGRE-PROG 2" TOTALIZER 32.4 CALCULATED 36.4 AT T/O +9+14 HOURS. NO FUEL LEAK AND ACCOMPLISHED QRH PROCEDURE (FUEL TEMP -31) (SYS IS OK IAW NOTE 2 OF FIM 28-41 FAULT TREE 838 CONFIG 3 BOX 1 AND BOX 21. NOTE STATES: INITIAL FUEL LOAD GREATEOct 8, 2012 · N640GT · Boeing 7673S1 · Central WarningSDR UIEA2012100800457Overheat Sensor · inoperativeBLEED DUCT OVERHEAT EICAS WARNING DURING TAKEOFF. ABORTED TAKEOFF AT 60 KNOTS. R & R LEAK DETECTOR ELEMENT, WHEEL WELL/WING DUCT LEAK CARD, AND MISCELLANEOUS TEST PANEL IAW AMM 26-18-00, 26-10-01, AND 26-18-01 REPECTIVELY. ALL TEST OK.Oct 8, 2012 · N640GT · Boeing 7673S1 · Overheat DetectionSDR UIEA2012100700454Fuel Filter · failedSTATUS MESSAGE "LT ENG FUEL FILTER" DISPLAYED, EICAS MESSAGE DISPLAYED ALSO DURING INTERMEDIATE CLIMB, BUT WENT OUT AT LEVEL-OFF. R & R LT ENGINE FUEL FILTER. ACFT LEAK CHECK ALL NORMAL, MESSAGE CLEARED, IAW AMM 73-11-02/401. NO CONTAMINATION APPARENT.Oct 7, 2012 · N640GT · Boeing 7673S1 · Engine Fuel DistributionSDR UIEA2012100600452Warning Message · false activationDURING FLIGHT, RT BLEED DUCT EICAS MESSAGE ILLUMINATED ACCOMPLISHED QRH PROCEDURE, LIGHT EXTINGUISHED. NO LIGHT ON GROUND, PERFORMED FIM IAW FIM 26-18 FAULT TREE 804 BITE CHECK, NO FAULT FOUND.Oct 6, 2012 · N640GT · Boeing 7673S1 · Detection SystemSDR UIEA2012092900445Slide · unwanted deployR4 DOOR SLIDE DEPLOYED. R & R DOOR SLIDE, DOOR FUNCTIONAL. IAW MM 25-66-01.Sep 28, 2012 · N640GT · Boeing 7673S1 · Escape Slide
Back to Boeing 767-3S1