SDR FDEA202408151127Floor Panel · gougedMAIN DECK COMP. AT APROX. STA 412 TO STA 490 & RBL 33 TO RBL 54.75 FLOORBOARD 232BFF HAS GOUGE AT SURFACE SKIN (MARKED). FABRICATED NEW FLOORBOARD PANEL #232BFF AT STA 412 TO STA 490 & RBL 33 TO RBL 54.75 IN REF. TO FEDEX DWG # SRZ-25-005. SEE JPF FOR OTHESDR FDEA202408151126Floor Panel · gougedMAIN DECK COMPARTMENT AT APROX. STA 412 TO 490 & LBL 33 TO LBL 11 FLOORBOARD 231BFF HAS GOUGE AT SURFACE SKIN. (MARKED). FABRICATED NEW FLOORBOARD PANEL #231BFF AT STA 412 TO STA 490 & LBL 33 TO LBL 11 IN REF. TO FEDEX DWG # SRZ-25-005. SEE JPF FOR OTHER WSDR FDEA202408151125Floor Panel · gougedMAIN DECK COPT. AT APROX STA 412 TO 490 &LBL77.5 FLOORBOARD 231EFF HAS GOUGE AT SURFAE SKIN (MARKED). FABRICATED NEW FLOORBOARD PANEL # 231EFF AT STA 412 TO STA 490 & LBL 77.5 IN REF. TO FEDEX DWG # SRZ-25-005. SEE JPF FOR OTHER WORK ACCOMPLISHED. THIS IS SDR FDEA202408141124Floorboard · delaminatedMAIN DECK COMP. AT APROX STA 285 TO STA 412 & RBL 33 TO RBL 54.75 FLOORBOARD 222BFF HAS SURFACE AREA INDENTATION (MARKED) FABRICATED NEW FLOORBOARD PNL# 222BFF AT STA. 285-412, RBL 33-RBL 54.75 IN REF TO FEDEX DRW# SRZ-25-005. SEE JPF FOR OTHER WORK ACOMSDR FDEA202408141123Floorboard · delaminatedMAIN DECK COMP. AT APROX STA 285 TO STA 412 & LBL 33 TO LBL 11 FLOORBOARD 221DFF HAS SURFACE AREA INDENTATION (MARKED) FABRICATED NEW FLOORBOARD PNL# 221DFF AT STA. 285-412, LBL 11-RBL33 IN REF TO FEDEX DRW# SRZ-25-005. SEE JPF FOR OTHER WORK ACOMPLISHEDSDR FDEA202408131120Fitting · crackedMAIN CARGO COMPARTMENT BETWEEN STA 977/999 AND RBL 11/33 FLOOR FITTING BROKEN. MAIN CARGO COMPARTMENT BTWN STA 977/999 AND RBL 11/33 FLOOR FITTING WAS REPLACED IAW E.A H-2550-T0380216SDR FDEA202408131115Floor Panel · dentedMAIN DECK COMPT. AT APROX STA 285 TO STA 412 & LBL11 TO RBL 11 FLOORBOARD 221CFF HAS SURFACE AREAA INDENTATION (MARKED). FABRICATED NEW MAINDECK CARGO FLOORBOARD PANEL # 221CFF LBL 11- RBL 11 P/N (141T5856- 105). IN REF. TO FEDEX DWG SRZ-25-005. SEE JPF FORSDR FDEA202408121112Floorboard · dentedMAIN DECK COMP. AT APROX. STA 285 TO STA 412 &RBL 11 TO RBL 33 FLOORBOARD 222AFF HAS SURFACE AREA INDENTAION FABRICATED MAIN DECK CARGO FLOORBOARD 222AFF P/N 141T5856-107 IAW SRZ-25-005.SDR FDEA202408121111Floor Panel · dentedMAIN DECK COMPARTMENT AT APPROXIMATELY STA 285-412 & RBL 54.75- RBL 77.5 FLOORBOARD 222CFF HAS SURFACE AREA INDENTATION (MARKED). FABRICATED NEW MAINDECK CARGO FLOORBOARD PANEL # 222CFF RBL 54.75- RBL 77.5 P/N (141T5856-116). IN REF. TO FEDEX DWG SRZ-25-00SDR FDEA202408101108Skin · burnedRH WING, OUTBOARD AILERON BETWEEN WBL 910 AND WBL 890 WITH TWO LIGHTNING STRIKE. RH WING, OUTBOARD AILERON BTW WBL 910 AND WBL 890 WAS REPAIRED IAW B767 SRM 57-60- 02-2R PAG 1 AND SRM 51-70-14-0G REP 11 PAG 17-18 REV 89 APR 15/2024SDR FDEA202408091107Wedge · gougedSLAT #5 HAS GOUGE ON UNDERSIDE OF TRAILING EDGE REPAIRED LH WING L/E #5 SLAT TRAILING EDGE WEDGE AT WS OSS. 456.98 IN REF. TO 767 SRM: 57-43-02-2R PG 1-2 DETAIL I & III FIG. 201 SHEET 1&2, AND 767 SRM: 51-70-10-2R FIG. 215 SHEET. 3. THIS IS A MAJOR REPAIR.SDR FDEA202408091106Frame · bentFOUND FRAME WEB DAMAGED AT FR390 BETWEEN STR35L AND STR 36L . FRAME WEB AT FR390 BETWEEN STR35L AND STR 36L REPLACED.SDR FDEA202408091105Failsafe · bentFRAME AT STA 456 BENT BETWEEN STR 37L AND STR38L FAIL-SAFE CORD REPLACED.SDR FDEA202408091104Frame · bentFRAME AT STA 434 BENT BETWEEN STR 36L AND STR 38L FRAME AT STA 434 BENT BETWEEN STR 36L AND STR 38L REPLACED.SDR FDEA202408091103Frame · bentFRAME AT STA 412 BENT BETWEEN STR 36L AND 38L FRAME AT STA 412 BENT BETWEEN STR 36L AND 38L REPLACED.SDR FDEA202408091102Failsafe · bentFRAME AT STA 390 LOWER L ANGLE (FAIL-SAFE CORD) BENT BETWEEN STR 34L AND STR 36L.SDR FDEA202408091101Stringer · bentSTRINGER 36L DAMAGED BETWEEN STA 434 TO SAT 456SDR FDEA202408091100Stringer · bentSTRINGER 38L DAMAGED FROM STA 434 TO 456SDR FDEA202408091099Stringer · bentSTRINGER 37L DAMAGED FROM STA 434 TO SAT 456.SDR FDEA202408091098Stringer · bentSTRINGER 37L DAMAGED AT STA 400 TO 434 REPLACED STRINGER 37L FROM STA 368 TO STA 434 IAW B767 SRM 51-40-02 THIS IS A MINOR REPAIR. SEE JPF FOR OTHER WORK STEPS.SDR FDEA202408091097Stringer · bentSTRINGER 36L DAMAGED FROM STA 395 TO STA 398 INSTALLED STRINGER 36L FROM STA 374 TO STA 434 P/N 141T3001-7 AND SPLICE BAC1498-203. REF B767 SRM 53-00-03-2R REPAIR 2 THIS IS A MINOR REPAIR. SEE JPF FOR ALL COMPLETED WORK STEPS.SDR FDEA202408091096Stringer · bentSTRINGER DAMAGED AT STA. 390. REPLACED STRINGER 35L FROM STA 362 TO STA 434 REF 767 SRM 53-00-03-2R-0 REPAIR 2. THIS IS A MINOR REPAIR.SDR FDEA202408061091Warning Light · illuminatedMAIN CARGO DOOR EICAS MESSAGE AND CARGO DOORS LIGHT ILLUMINATED AT CRUISE FL350 TIME 0051Z. ALSO HAD RISING CABIN PRESSURE. RAN QRH AND DESCENDED TO 10,000 FEET PER QRH. AFTER LEVELING AT 10,000 FEET, EICAS MESSAGE AND CARGO DOORS LIGHT EXTINGUISHED AFTERSDR FDEA202408051086Floor Panel · dentedMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 251KFF WITH SEVERAL DENTS. MAIN DECK CARGO, FLOOR PANEL 251KFF WAS REPAIRED I.A.W. B767 SRM 53-00-50-2R PAR. 4.B FIG. 201 SHEET 2 REV. 89 APR 15/2023.SDR FDEA202408051085Floor Panel · crackedMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 241WFF WITH A PUNCTURE. MAIN DECK CARGO, FLOOR PANEL 241WFF WAS REPAIRED I.A.W. B767 SRM 53-00-50-2R PAR 4.B FIG. 201 SHEET 2 REV. 89 APR 15/2024.SDR FDEA202408051084Skin · dentedSLAT 11, EXTERNAL SURFACE, UPPER WEDGE WITH DENT NEXT TO INB FRAME. SLAT 11, EXTERNAL SURFACE, UPPER WEDGE WITH DENT NEXT TO INB FRAME WAS REPAIRED IAW B767 SRM 57-43-02-2R REP 1 PAG 1-2 AND SRM 51-70-10-2R REPAIR 4 PAG 150-151 FIG 201 (SHEET 1) REV 89 APRSDR FDEA202408051083Floorboard · delaminatedNR #7 READ "FLOORBOARD DAMAGED BETWEEN STATIONS 1100-1197". INSPECTED NOT ACCEPTED. MAIN DECK FLOORBOARD REPAIR MISCLASSIFIED AS MINOR REPAIR. RII BUYBACK FOR MAJOR REPAIR MISSED ON SHIFT REF GMM 6-1-800. FABRICATED NEW FLOORBOARD (251AFF) (MPN: 146T5869-8SDR FDEA202408051082Seat Track · damagedSEAT TRACK LOBE DAMAGED AT APPROXIMATELY STA.500 RBL 11. REMOVED AND INSTALLED SEAT TRACK, REPAIR ANGLES (2EACH) AND REPAIR STRAP (1EACH) PER FDX E.A. H-5310-T0380146 AND SRM 53-00-52-2R REPAIR 9.SDR FDEA202407301066Transponder · faultedENROUTE GOT AN ATC FAULT EICAS MESSAGE. CREW REPORT SYSTEM RECOVERED DURING FLIGHT.TESTING IN PROGRESS. FIM: 34-53 FAULT TREE 803, BOTH ATC TRANSPONDERS TESTED PER FIM TASK34-53. FAULT TREE 803. NO FAULTS SHOWN AND BOTH TESTED SATIS. GREEN LED INDICATED ATSDR FDEA202407271065Skin · delaminatedLH, WING, OUTBOARD FLAP TRAILING EDGE WITH DELAMINATION AT 42" OF OUTER END LH, WING, OUTBOARD FLAP TRAILING EDGE AT 42" OF OUTER END WAS REPAIRED IAW B767 SRM 57-53-01-2R FIG. 201 SHEET 5 TABLE I AND SRM 51-70-03-0G PAGRAP. 5.A FIG 5 SHEET 1 REV. 89 APR SDR FDEA202407271064Floor Panel · dentedMAIN DECK CARGO COMPATMENT, STA 764 ,241AFF FLOOR PANEL WITH DENTS MAIN DECK CARGO COMPATMENT, STA 764 ,241AFF FLOOR PANEL WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR. 4.B REV. 89 APR 15/2023SDR FDEA202407271063Former · crackedDURING HMV1, LFC, LSY4 CHECK AT INDY HVMX WE HAVE FASTENERS LOOSE/DAMAGE ON LS/RS FLE SKIN (MISSING AND COMING OUT), AT LS FLE S OSS 441. FORMER CRACKED AT LS OSS 441, PN 114T2170-5 WITH ANGLE 114T2171-4, FORMER IS ATTACHED TO RIB 114T2241-7. REMOVED (PN 1SDR FDEA202407271062Skin · dentedLEFT WING, OUTBOARD FLAP, OTEF STA 43 APPROX, UPPER PANEL, LOWER SURFACE, SKIN WITH DENTS LEFT WING, OUTBOARD FLAP, OTEF STA 43 APPROX, UPPER PANEL, LOWER SURFACE WAS REPAIRED IAW B767 SRM 57-53-01-2R FIG 201 PAG 3 AND SRM 51-70-10-2R REP 4 FIG 201 (SHEET SDR FDEA202407271061Former · crackedDURING HMV1, LFC, LSY4 CHECK AT INDY HVMX WE HAVE FASTENERS LOOSE/DAMAGE ON LS/RS FLE SKIN (MISSING AND COMING OUT), AT RS FLE S OSS 499; ALSO HAVE FORMERS CRACKED. FORMER CRACKED AT RS OSS 499, PN 114T2511-14 WITH ANGLE 114T2511-12, FORMER IS ATTACHED TSDR FDEA202407271060Floor Panel · dentedMAIN DECK CARGO COMPARTMENT, FLOOR WITH DENTS BTW STA 450 AND STA 500 AND LBL 88 AND LBL 33. MAIN DECK CARGO COMPARTMENT, FLOOR 221EFF BTW STA 450 AND STA 500 AND LBL 88 AND LBL 33 WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV:89 APR 15SDR FDEA202407271059Floor Panel · dentedMAIN DECK CARGO COMPARTMENT, FLOOR WITH DENT BTW STA 1115 AND STA 1197 13 AND RBL 88 AND RBL 33. MAIN DECK CARGO COMPARTMENT, FLOOR 252CFF BTW STA 1115 AND STA 1197 13 AND RBL 88 AND RBL 33 WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REVSDR FDEA202407231047Slat System · asymetricLE SLAT ASYM WHEN SELECTING F25 FROM F20. EMERGENCY DECLARED. FIM: 27_51_00_815_809 CHECKED FSEU LAST FLIGHT FAULTED LE DISAGREE, TE FLAPS AND MSG 27-81045 AMM: 27-81-00-2 PER MOCC AHM REPORTED SLATS & FLAP HANDLE WAS NOT COMPLETELY IN 25 DETENT. PERFORSDR FDEA202407161023Aileron · wornLEFT WING, INBOARD AILERON LOWER LEADING EDGE WITH WEAR ON INBOARD SECTION. LEFT WING, INBOARD AILERON LEADING EDGE, INBOARD SECTION WAS REPAIRED IAW B767 SRM 57-60-01-2R FIG 201 (SHEET 9) TABLE VII AND SRM 51-70-17-0G PAGRAP. 4.A REV 89 APR 15/2024SDR FDEA202407161022Flap · crackedLEFT WING, INBOARD AFT FLAP LOWER SURFACE WITH PUNCTURE AT 8" FROM LEADING EDGE AND 36" FROM OUTBOARD FAIRING LEFT WING, INBOARD AFT FLAP LOWER SURFACE AT 8" FROM LEADING EDGE AND 36" FROM OUTBOARD FAIRING WAS REPAIRED IAW B767 SRM 57-53-01-2R DETAIL III NSDR FDEA202407161021Flap · crackedLEFT WING, INBOARD AFT FLAP LOWER SURFACE WITH DENT AT 11" FROM LOWER EDGE AND 38.5" FROM OUTBOARD FAIRING LEFT WING, INBOARD AFT FLAP LOWER SURFACE AT 11" FROM LOWER EDGE AND 38.5" FROM OUTBOARD FAIRING WAS REPAIRED IAW B767 SRM 57-53-01-2R FIG 201 (SHEETSDR FDEA202407151014Circuit Card · failedFIRE WARNING BELL CAME ON AT ROTATION. NO OTHER INDICATIONS. BELL WILL NOT SILENCE EVEN AFTER BLOCK IN AND ENGINES SHUTDOWN. MDIS 31-50 1103. REF. FIM 31-51 TASK 801, DID A WEU BITE & RESET.TEST NORMAL IAW AMM 31-51-00-5, PERFORMED FIRE BELL WARNING SISDR FDEA202407151013Floor Panel · dentedZONE 200, UPPER HALF OF FUSELAGE, MAIN DECK CARGO COMPARTMENT, MAIN DECK FLOOR PANEL 231KFF WITH DENTS. MDC, FLOOR PANEL 231 KFF WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV:88 DEC 15/2023SDR FDEA202407151012Floor Panel · dentedZONE 200, UPPER HALF OF FUSELAGE, MAIN DECK CARGO COMPARTMENT, MAIN DECK FLOOR PANEL 251DFF WITH PUNCTURE AND DENT. MDC, FLOOR PANEL 251DFF WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV:88 DEC 15/2023SDR FDEA202407151011Floor Panel · dentedZONE 200, UPPER HALF OF FUSELAGE, MAIN DECK CARGO COMPARTMENT, MAIN DECK FLOOR PANEL 252CFF WITH DENT. MDC, FLOOR PANEL 252CFF WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV:88 DEC 15/2023SDR FDEA202407151010Floor Panel · dentedZONE 200, UPPER HALF OF FUSELAGE, MAIN DECK CARGO COMPARTMENT, MAIN DECK FLOOR PANEL 222CFF WITH DENTS. MDC, FLOOR PANEL 222CFF WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV: 88 DEC 15/2023SDR FDEA202407151009Floor Panel · dentedZONE 200, UPPER HALF OF FUSELAGE, MAIN DECK CARGO COMPARTMENT, MAIN DECK FLOOR PANEL 251CFA WITH DENTS. MDC, FLOOR PANEL 251CFA WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV:88 DEC 15/2023SDR FDEA202407151008Floor Panel · dentedZONE 200, UPPER HALF OF FUSELAGE, MAIN DECK CARGO COMPARTMENT, MAIN DECK FLOOR PANEL 251EFF WITH DENTS. MDC, FLOOR PANEL 251EFF WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV:88 DEC 15/2023SDR FDEA202407151007Floor Panel · dentedZONE 200, UPPER HALF OF FUSELAGE, MAIN DECK CARGO COMPARTMENT, MAIN DECK FLOOR PANEL 222BFF WITH DENTS. MDC, FLOOR PANEL 222BFF WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV:88 DEC 15/2023SDR FDEA202407151006Floor Panel · dentedZONE 200, UPPER HALF OF FUSELAGE, MAIN DECK CARGO COMPARTMENT, MAIN DECK FLOOR PANEL 221DFF WITH DENTS. MDC, FLOOR PANEL 221DFF WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV:88 DEC 15/2023SDR FDEA202407151005Floor Panel · dentedZONE 200, UPPER HALF OF FUSELAGE, MAIN DECK CARGO COMPARTMENT, MAIN DECK FLOOR PANEL 222AFF WITH DENTS. MDC, FLOOR PANEL 222AFF WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV:88 DEC 15/2023
Back to Boeing 767-3S2F