Boeing 767-3Y0
Service difficulty reports · 1,443
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673Y0' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673Y0' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2020070701490Plug · undersizeDURING BOROSCOPE INSPECTION, DISCOVERED AP-9 BOROSCOPE PLUG AT THE 3.0 CLOCK POS ON DIFFUSER CASE, SHAFT DIAMETER IS METER IS LESS THAN 0.100 IN NR 2 ENGINE. REMOVED AND REPLACED AP-9 BOROSCOPE PLUG IAW 767 AMM 72-00-00-206-364.SDR P5CA2020070730247Valve · malfunctionedFWD EQUIP VAL EICAS MESSAGE AFTER ENGINE START. REPEAT WRITE-UP. SEE LOGBOOK PAGE 1279386. REMOVED AND REPLACED THE MANIFOLD INTERCONNECT VALVE V90 IAW AMM 21-58-01. OPS CHECKS GOOD. PERFORMED ENGINE RUNS IAW AMM 71-00-00. OPS CHECKS GOOD. NO DEFECTS NOTED.SDR P5CA2020070700262Warning Message · false activationFWD EQPT VALVE EICAS DISPLAYED AFTER ENGINE START. PERFORMED FIM 21-58 TREE 805, NO DEFECTS NOTED. PERFORMED FWD EQUIPMENT OPS CHECK IAW AMM 21-58-00, OPS CKS GOOD.SDR UIEA2020070201454Control Valve · malfunctionedAPU PNEUMATIC INOP (AUXILIARY POWER UNIT, PNEUMATIC FUNCTION). PERFORMED BITE CHECK OF SYSTEM PER AMM 49-61-05. NO FAULTS NOTED. APU START 1ST ATTEMPT. CB BREAKER S-23 C VALVE VERIFIED IN OFF POSITIONS PER 36-11-04. REMOVED AND REPLACED SURGE CONTROL VALVSDR P5CA2020062530203Relay · failedAFT EXHAUST FAN 2 STATUS MESSAGE. REMOVED AND REPLACED K886 AFT EXHAUST FAN SHUT OFF RELAY 2 IAW WDM 21-26-16 AND K347 AFT / EQUIP LAV GALLEY VENT FAN 2 RELAY IAW WDM 21-26-11. OPS CHECK GOOD IAW AMM 21-26-01.SDR P5CA2020061900200Apu · shutdownAPU SHUTDOWN. REMOVED AND REPLACED APU IAW AMM 49-11-01. OPS TEST GOOD AT THIS TIME. NO DEFECTS NOTED ON ECU AT THIS TIME, REF AMM 49-61-05. NO DEFECTS DETECTED.SDR UIEA2020061981312Indicator · no testINSTRUMENT COOLING SYSTEM, E1-E2 BALL NOT TESTING. REMOVED AND REPLACED THE E/E MONITOR INDICATOR IAW AMM 21-58-34. OPS TESTED OK.SDR UIEA2020061801311Status Message · false activationSTATUS MESSAGE WEATHER RADAR SYS. PERFORMED FIM 34-43 FT 805 UP TO AND INCLUDING SHEET 1, BLOCK 2. COULD NOT DUPLICATE DISCREPANCY. OPS CHECKED GOOD.SDR P5CA2020061800199Apu · inoperativeAPU INOPERATIVE. SERVICED APU IAW AMM 12-13-04 AND PERFORMED AN OPS CHECK IAW AMM 49-11-00. OPS CHECKED GOOD.SDR P5CA2020061760197Apu · smokeDURING POST FLIGHT NOTICED APU WAS EXHAUSTING SMOKE. APU SHUT DOWN, NO APU FIRE INDICATION. ACCOMPLISHED VISUAL INSPECTION OF APU TAIL PIPE AND EXTERIOR OF APU, NO DISCREPANCIES NOTED. ACCOMPLISHED FIM TASK 49-11-00-815, NO FAULTS. ACCOMPLISHED APU ECU BITE LSDR P5CA2020061500194Circuit Breaker · trippedLEFT WX RADAR FAIL. FOUND LEFT CIRCUIT BREAKER NR 2 OUT, RESET PER MM 20-90-01, ACCOMPLISHED WXR SYSTEM TEST PER MM 34-43-00/001 CONFIG 2. NO DEFECTS NOTED AND NO PREVIOUS C/B DISCREPANCIES.SDR P5CA2020061500193Warning Message · false activationL GEN OFF MSG ON DEPARTURE. RAN QRH TO CLEAR. PERFORMED L IDG OPERATIONAL TEST IAW AMM 24-11-00. OPS CHECK GOOD. NO FAULTS NOTED. SERVICED LEFT IDG IAW AMM 12-13-03.SDR P5CA2020061200190Stowage Box · faultyFO OXY MASK DOES NOT TEST PROPERLY. M2: FIRST OBS SEAT INOP DUE TO OXYGEN MASK INOP. SWAPPED MASK WITH FIRST OBS POSITION IAW AMM 35-11-04, OPS CHECK OK. NOW FIRST OBS SEAT INOP DUE TO OXYGEN MASK INOP. REMOVED AND REPLACED FIRST OBSERVERS OXYGEN MASK STORASDR UIEA2020061091258Radar · failedWEATHER RADAR SYS LEFT AND RIGHT FAIL INDICATIONS. RESET WX RADAR C/B LT & RT. PERFORMED OPS CHECK IAW AMM 34-43-00. ALL CHECKS GOOD.SDR UIEA2020060801235Warning System · false activationSTATUS MESSAGE WXR SYS WENT ON RIGHT RADAR. PERFORMED FIM TASK 34-43 FAULT TREE 805 FIG 103. OPS GOOD.SDR P5CA2020060800173Escape Reel · deployedDURING WALKAROUND FOUND NUMBER 3 EMERGENCY DESCENT DEVICE DEPLOYED. REMOVED AND REPLACED NUMBER THREE EMERGENCY DESCENT DEVICE IAW AMM 25-61-00. OPS CHECKS NORMAL.SDR UIEA2020060501201Adapter · corrodedLEFT WING UPPER SURFACE OVERWING FILL PORT ADAPTER FLANGE HAS CORROSION. REMOVED CORROSION FROM LT WING UPPER FILL PORT ADAPTER FLANGE AND WAS FOUND OUT OF LIMITS IAW SRM 57-20--01-1A-1. REPAIRED OVERWING FILL PORT ADAPTER FLANGE IAW FAS EA 20017 REV IR.SDR UIEA2020060501203Attach Fitting · brokenLT WING OB FLAP OB TRACK, LWR TRAILING EDGE ATTACH FITTING AT WBL 710 BROKEN. REMOVED AND REPLACED THE ATTACH FITTING ON THE LT WING OB FLAP TRACK TRAILING EDGE AT WBL 710 IAW SRM 51-40-02.SDR P5CA2020052900164Escape Reel · deployed1X DESCENT DEVICE DEPLOYED DURING LANDING. REMOVED AND REPLACED DESCENT DEVICE IAW AMM 25-61-05. CHECKED INTEGRITY OF RETAINER DOOR LATCH IAW AMM 25-61-05. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2020051801075Knob · looseWX RADAR TILT KNOB OFF 2 DEGREES FROM ACTUAL POS. 0 DEGREES ON KNOB INDICATES -2 DEGREES(<P>FOUND TILT KNOB LOOSE. SECURED AND PERFORMED WX RADAR OPERATIONAL SYSTEM TEST IAW AMM 34-43-00. OPS AND INDICATION NORMAL.</P>)SDR UIEA2020051801074Control Panel · faultyWX RADAR TILT KNOB 2 DEGREES OFF FROM ACTUAL POSITION, KNOB SHOWS 7 ACTUAL IS 5 ETC.(<P>REMOVED AND REPLACED PANEL EFIS CONTROL IAW AMM 34-43-02, OPS TEST OK IAW AMM 34-22-02.</P>)SDR P5CA2020051300158Connector · dirtyRIGHT ENGINE START VALVE LIGHT INOP(<P>TRANSFER TO MDDR 128306 IAW DDG 80-00-01-01, CAT 'C' DUE DATE MAY 23-20.</P><P>LP 1147450: VERIFIED START VALVE CANNON PLUG, CLEANED AND SECURED. ACCOMPLISHED STARTER MM 71-00-00. ACCOMPLISHED #2 ENG START VALVE LIGHT OPSDR P5CA2020051200156Panel · malfunctionedRT FO'S WX SWX BULB BURNT OUT.(<P>REMOVED AND REPLACED ANNUNCIATION ASSY IAW SPM 20-61-00. OPS CHECK GOOD IAW AMM 34-43-00.</P>)SDR UIEA2020051401021Engine · malfunctionedAFTER TAKEOFF HAD SMOKE/FUMES IN COCKPIT(<P>PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION REF AMM 05-51-56. REMOVED OIL CONTAMINATION FROM THE AIR CONDITIONING AND PNEUMATIC SYSTEM REF AMM 21-00-21-102.</P><P>LP 1130723 - M6: REMOVED AND REPLACED LESDR UIEA2020051101006Warning System · false activationON CLIMB OUT RECEIVED R FWD FUEL PUMP MESSAGE WITH PRESS LIGHT (<P>T/S IAW FIM 28-22 FAULT TREE 819 PUMP OPERATES NORMAL. ALSO T/S IAW FIM 28-41-FAULT TREE 854. NO FAULTS FOUND.</P>)SDR UIEA2020051500993Control Valve · malfunctionedAPU AUTO SHUTDOWN / APU FAULT.(<P>APU DEFERRED IAW MEL 49-11-01A THIS IS A CAT "C" ITEM. APU ECU SHOWS "HIGH OIL TEMP" FAULT MDDR# 128079. TIME 22:49Z INT: JT DUE DATE 17MAY20.</P><P>LP 1140515: REMOVED AND REPLACED OIL TEMP CONTROL VALVE ASSY IAW AMM 49-27-10SDR UIEA2020050800995Unknown · odorSTRONG STINK ODOR FROM PACKS BELOW 10K FEET.(<P>TRANSFERRED TO MDDR 128086 IAW DDG 21-51-01-01, CAT 'C', DUE DATE 18MAY20, MAINT ACTIONS C/W. NOTE: MX VERIFIED SMELL STRONG FROM LEFT PACK, DEFERRAL IS FROM LEFT PACK ONLY. T&I JT0142Z.</P><P>LP 1130707: PERFORMSDR UIEA2020050800990Control Module · faultyAFT EQ EXH FAN 2 EICAS MSG.(<P>TRANSFERRED TO MDDR 128074 PER MEL 21-58-05, CAT 'C', DUE DATE: 17MAY20. DISPATCHER: JT @18:24Z.</P><P>LP 1130713: REPLACED ECS FAN CONTROL MODULE M861 IAW AMM 21-58-24. CHKS GOOD. CLOSED MDDR 128074.</P>)SDR UIEA2020050800993Ecu · faultedAPU AUTO SHUTDOWN / APU FAULT.(<P>APU DEFERRED IAW MEL 49-11-01A THIS IS A CAT "C" ITEM. APU ECU SHOWS "HIGH OIL TEMP" FAULT MDDR# 128079. TIME 22:49Z INT: JT DUE DATE 17MAY20.</P>)SDR UIEA2020050600948Unknown · malfunctionedAPU FAILED AND SHUTDOWN BEFORE ENG START(<P>PLACED ON MDDR 127985 PER MEL 49-11-01A, CAT 'C'.</P><P>08MAY20, BWI LP 1150050, ITEM M5: PERF APU BITE IAW FIM 49-11 FT 958. FOUND NO FAULTS. APU OPERATING NORMAL AND STARTING PARAMETERS SHOW NO SIGNS OF A BAD STARTSDR UIEA2020050700953Air Duct · contaminatedBURNT OIL SMELL FROM AIR CONDITIONING SYSTEM WHEN THROTTLES ADVANCED FOR DEPARTURE AND ON DESCENT DURING 16K.(<P>PER CUSTOMER REQUEST, PERFORMED REMOVAL OF OIL CONTAMINATION PER B767 AMM 21-00-201 FROM THE AIR CONDITIONING AND PNEUMATIC SYSTEMS, VISUALLY INSPESDR UIEA2020050600970Unknown · odorPACKS HAVE A VERY DIRTY SMELL ON TAKEOFF & APPROACH.(<P>ACCOMPLISHED OPS TEST OF COOLING SYSTEM THRU FULL TEMP RANGE IAW AMM 21-51-00. COULD NOT REPRODUCE SMELL ON GROUND.</P>)SDR UIEA2020042870847Terminal · brokenRIGHT ENGINE FIRE LOOP 1 INOPERATIVE. REMOVED AND REPLACED THE CARD ASSY FIRE DETECTOR ENGINE 2 LOOP IAW AMM 26-11-01. FAULT COULD NOT BE DUPLICATED. FOUND LOWER AFT FIRE DETECTOR WITH A BROKEN TERMINAL, REPLACED THE TERMINAL AT TS 682 IAW WDM 26-11-21 AND SDR P5CA2020042400148Warning System · false activationSTATUS RIGHT ENG TAI VALVE.(<P>PERFORMED OPERATIONAL CHECK OF ENGINE # 2 TAI VALVE WITH ENGINE PNEUMATICS REF AMM 30-21-00. COULD NOT DUPLICATE FAULT AT THIS TIME, OPERATIONAL CHECK GOOD.</P>)SDR UIEA2020042300815Shutoff Valve · malfunctionedL ENG BLEED OFF AFTER BOTH ENG STARTED. COMPLETE SHUTDOWN OF L ENG & RE-START BUT DID NOT CLEAR, RTB PARKING.(<P>REMOVED AND REPLACED L PRSOV VALVE I.A.W AMM 36-11-09. OPS CHECK GOOD.</P>)SDR UIEA2020042300809Fire Warning · false activationAPU FIRE LP 1 STATUS MSG AFTER SHUTDOWN(<P>PERFORMED FIRE OVERHEAT TEST IAW AMM 26-11-01. OPS CHECK NORMAL.</P>)SDR UIEA2020042000773Control Valve · faultyRH PACK TEMP EICAS MSG(<P><SPAN>T/S IAW B767 FIM 21-51 FT 844, FOUND TEMP CONTROL VALVE FAULT LIGHT ON PTC BUS. RIGHT TEMP CONTROL VALVE NOT IN STOCK. PLACED ON REQ WITH MCC. SEE LP #1189889 ITEM M8 FOR REPLACEMENT.</SPAN></P><P>LP 1189889 - M8: ITEM TRANSFERRSDR UIEA2020041700760Status Message · false activationCABIN ALT AUTO 1 STATUS MSG.(<P>COMPLIED WITH BITE TEST OF #1 AUTO CABIN PRESS CONTROLLER, TEST PASS, NO FAULTS LATCHED. OK FOR CONTINUED SERVICE I/A/W MM CH 21-31-00.</P>)SDR UIEA2020041400751Pressure Switch · disconnectedR ENG NOSE COWL THERMAL ANTI ICE PRESSURE SWITCH IS DISCONNECTED AND HEAVILY CORRODED INSIDE CONNECTOR P/N 215N41-84.(<P>REMOVED AND REPLACED THERMAL ANTI ICE PRESSURE SWITCH IAW AMM 30-21-01/401 REV 129. OPS CHECK GOOD.</P>)SDR P5CA2020041300142Control Unit · malfunctionedL SIDE WINDOW HEAT INOP(<P>REMOVED AND REPLACED L SIDE/RFWB WINDOW HEAT CONTROL UNIT IAW AMM 30-41-01. OPS CHECKS GOOD.<BR /></P>)SDR UIEA2020040900722Unknown · malfunctionedB LOOP ON CARGO DETECT INOP (<P>TRANSFERRED TO MDDR #126848 I.A.W MEL 26-16-02-01, CAT C.</P><P>LOG PAGE 1189953: PERFORMED BITE PROCEDURE ON MAIN DECK CARGO REF FIM 26-19 FT 803. NO MESSAGE NOTED. TEST PASS, MDDR #126848 CLOSED.</P>)SDR UIEA2020040800715Eec · malfunctionedPRIOR TO ENGINE START, WITH SELECTION OF HYDRAULIC DEMAND PUMPS, APU AUTO SHUT DOWN DUE TO RIGHT EEC CB CHANNEL A.(<P>RESET CB, REF FIM 73-21 FT 885, NO FAULTS NOTED.</P><P>ITEM 2: APU STARTED FIRST ATTEMPT, NO APU WORK DONE, NO FAULTS NOTED. NO COLD SOAK REQUSDR P5CA2020040800140Start Valve · failedLEFT ENG START VALVE FAILED(<P>TRANSFERRED TO MDDR 126765, MEL 80-00-02-01, CAT C, DUE DATE 17APR20.</P><P>LP 1232027 ITEM 2: REMOVED AND REPLACED LEFT ENG START VALVE IAW AMM 80-11-02. OPS CHECK GOOD. THIS CLEARS MDDR 126765. PLACARD REMOVED.</P>)SDR UIEA2020040600693Rotary Switch · defective(THIRD GRIPE) APU SWITCH EXTENDS BEYOND START, THEN RETURNS TO START VICE ON POSITION. NEEDS ADJUSTMENT. APU OPERATES 4.0.(<P>TRANSFERRED TO MDDR 126667 IAW DDG 49-11-01A, CAT C, DUE DATE 14APR2020.</P><P>LOG PAGE 1150016 ITEM 2: REMOVED AND REPLACED APU ROTARSDR P5CA2020040600139A/C Pack · odorSTRONG MUSTY SMELL FROM LEFT PACK.(<P>PERFORMED LEFT/RIGHT PACK CLEAN OUT IAW AMM 21-00-21.<BR /></P>)SDR UIEA2020040600684Exciter · faultyAPU FAULT ON START ATTEMPT. ATTEMPTED TWICE. 20 MAX RPM W/ NO EGT RISE.(<P>TRANSFERRED TO MDDR 126631 PER MEL 49-11-01A, CAT C, DUE DATE 13APR20. DI: JT @ 20:37Z.</P><P>BWI, 04APR, LP 1071367, ITEM M2: REMOVED AND REPLACED APU IGNITION EXCITER IAW AMM 49-41-03SDR UIEA2020040600686Switch · looseAPU SWITCH LOOSE, APU OPERATES NORMALLY, SWITCH JUST NEEDS ADJUSTMENT.(<P>ADJUSTED APU SWITCH IAW AMM 49-61-00. OPS TEST OK.</P>)SDR UIEA2020040600704Switch · malfunctionedAPU SWITCH STICKS IN START POSITION(<P>CHECKED APU SWITCH FOUND TO BE IN NORMAL OPERATION IAW AMM 49-61-00. NO FURTHER DEFECTS NOTED AT THIS TIME.</P>)SDR P5CA2020040200138Starter · failedLEFT STARTER FAILURE DURING ENGINE START AFTER PUSH BACK.(<P>REMOVED AND REPLACED AND SECURED LEFT ENGINE STARTER IAW B767 AMM 80-11-01. OPS CHECK GOOD.</P>)SDR P5CA2020033100137Control Valve · faultyAPU DOES NOT INCREASE PNEUMATIC PRESSURE ON ENGINE START.(<P>TRANSFERRED APU PNEUMATIC FUNCTION TO DMI 126477 PER B767 DDG 49-11-01-01, CAT "C" DUE 10APR2020.</P><P>REF LOG PAGE 1232005 ITEM M4: REMOVED AND REPLACED SURGE CONTROL VALVE IAW AMM 49-53-01. OPS TE
Back to Boeing 767-3Y0